3Dec 08, 2003
SAW Components X 6941 D
44,00 MHzBandpass Filter
Data Sheet
Characteristics
Reference temperature:
T
A= 25 ˚C
Terminating source impedance:
Z
S= 50 Ω
Terminating load impedance:
Z
L= 2 kΩ || 3 pF and matching network
min. typ. max.
Insertion attenuation α
Reference level for the 44,00 MHz 18,5 20,0 21,5 dB
following data
Amplitude ripple (p-p) ∆α
41,60 ... 46,40 MHz — 0,4 — dB
Relative attenuation αrel
40,75 MHz 25,0 32,0 — dB
41,31 MHz 1,1 1,6 2,1 dB
41,43 MHz –0,4 0,3 1,0 dB
41,60 MHz –0,4 0,1 0,6 dB
46,40 MHz –0,4 0,1 0,6 dB
46,57 MHz 0,1 0,6 1,1 dB
46,69 MHz 1,5 2,0 2,5 dB
47,25 MHz 25,0 36,0 — dB
Lower sidelobe 35,00 ... 39,10 MHz 34,0 42,0 — dB
39,10 ... 40,35 MHz 27,0 32,0 — dB
Upper sidelobe 47,65 ... 48,65 MHz 25,0 30,0 — dB
48,65 ... 55,00 MHz 32,0 37,0 — dB
Reflected wave signal suppression
1,5 µs ... 6,0 µs after main pulse 42,0 56,0 — dB
(test pulse 250 ns,
carrier frequency 44,00 MHz)
Group delay ripple (p-p) ∆τ
41,31 ... 46,69 MHz —3080ns
Impedance at 44,00 MHz
Input:
Z
IN =
R
IN ||
C
IN — 1,9 || 22,2 — kΩ || pF
Output:
Z
OUT =
R
OUT ||
C
OUT —6,1 || 5,7 —kΩ || pF
Temperature coefficient of frequency
TC
f— –18 — ppm/K
Matching network:
Lp1 = 1800 nH