www.vishay.com
41
RLP
Vishay Sfernice
Document Number: 50009
Revision 03-Mar-06
For technical questions, contact sfer@vishay.com
25 min. 25 min.
A
Ø B
Ø E
L max.
44
45° chamfer
max. 0.25 deep
Ø a ±0.02
RLP1 - RLP2 a = 1mm
RLP3 - 6 - 10 a = 1.2mm
Insulated Precision Wirewound Resistors
Axial Leads
TECHNICAL SPECIFICATIONS
VISHAY SFERNICE SERIES AND STYLE
NF C 83-210
CECC 40201-006
VISHAY SFERNICE
Limits
± 5 % E24
± 2 % E48
Power Rating
at + 25 °C
Ohmic Range
in Relation
to Tolerance
Qualified Ohmic Range
NF C 83-210
Limiting Element Voltage
Critical Resistance
RLP1
RP8
A
1 W
0.05 Ω
2.2 kΩ
0.05 Ω
2.2 kΩ
1Ω
470 Ω
50 V
RP7
B
2 W
0.025 Ω
6.8 kΩ
0.025 Ω
6.8 kΩ
0.2 Ω
1.78 kΩ
120 V
out of nominal ohmic range
RP4
C
3 W
0.01 Ω
15 kΩ
0.01 Ω
15 kΩ
0.1 Ω
3.57 kΩ
200 V
RP5
D
6 W
0.02 Ω
59 kΩ
0.02 Ω
59 kΩ
0.1 Ω
12.1 kΩ
300 V
17800Ω
RP6
E
10 W
0.06 Ω
150 kΩ
0.06 Ω
150 kΩ
± 1 % E96 0.05 Ω
2.2 kΩ0.025 Ω
6.8 kΩ
0.01 Ω
15 kΩ
0.02 Ω
59 kΩ
0.06 Ω
150 kΩ
± 0.5 % E96 0.4 Ω
2.2 kΩ
0.4 Ω
6.8 kΩ
0.3 Ω
15 kΩ
0.3 Ω
59 kΩ
0.3 Ω
150 kΩ
± 0.1 % E96 Please consult VISHAY SFERNICE
0.1 Ω
40.2 kΩ
720 V
51100 Ω
RLP2 RLP3 RLP6 RLP10
Undergoes European Quality Insurance System (CECC)
FEATURES
1 Watt to 10 Watt at 25 °C
• CECC 40201-006
Conforms to NF C 83-210
• Excellent stability
• High power
• Low ohmic values
• Low temperature coeffi cient
• Electrical insulation
• Climatic protection
25 min. 25 min.
A
Ø B
Ø E
RLP 1 - RLP 2
INSULATED MOLDED
In wirewound precision resistors, the RLP series holds a
leading position in professional applications whenever an
excellent stability of the ohmic value and a correspondingly
low temperature coeffi cient are required at the same time.
The RLP model resistors comply with the most stringent
requirements of the NF C 83-210 specifi cation.
The series consists
of 5 models covering the power range from 1 W to 10 W.
Non-inductive versions can be supplied on request by
specifying RLP-NI. For higher power dissipations, the use
of RH series resistors is recommended.
DIMENSIONS in millimeters
ØB
max.
R 0.15 Ω
R > 0.15 Ω
DIMENSIONS in millimeters
SERIES
AND STYLE
7 10.2 14 23.82 46.78
RLP 1
RLP 2
RLP 3 RLP 6
RLP 10
4.0 5.54
6
8.71 10.32
11
0.6 0.6 0.8 0.8 0.8
2.5 9
A max.
MOLDED INSULATED
E ± 0.1
0.27 0.48 1.3 3.4 8.6
Weight in g
Document Number: 50009
Revision 03-Mar-06
www.vishay.com
42
RLP
Vishay Sfernice
For technical questions, contact sfer@vishay.com
TESTS
Dielectric W/s Voltage
Short Time Overload
Climatic Sequence
Humidity (Steady State)
500 VRMS for RLP1-2-3
1000 VRMS for RLP6-10 ± (0.1 % + 0.05 Ω)
± 0.25 % + 0.05 Ω
± 0.5 % + 0.05 Ω
Insulation R > 100MΩ
± 0.5 % + 0.05 Ω
Insulation R > 100MΩ
± (0.2 % + 0.05 Ω)
± (0.05 % + 0.05 Ω)
± (0.2 % + 0.05 Ω)
Ins. resistance > 103 MΩ
± (0.25 % + 0.05 Ω)
Ins. resistance > 103 MΩ
5 Pn/5 s for Pn < 5 W
10 Pn/5 s for Pn 5 W
NF C 83-210
fasc. 19A – 55 °C/+ 200 °C
5 cycles
NF C 83-210
fasc. 3A 56 days 95 % R.H.
Vibration
Load Life
Moisture Resistance
High Temperature
Shock
± (0.1 % + 0.05 Ω)± 0.25 % + 0.05 Ω
± 0.5 % + 0.05 Ω
Insulation R 1GΩ
± (0.5 % + 0.05 Ω)
± (0.2 % + 0.05 Ω)
Insulation resistance
>100M
± (0.5 % + 0.05 Ω)
± (0.1% + 0.05Ω)
± 0.5 % + 0.05 Ω
Insulation R 1GΩ
± 0.25% + 0.05Ω
± (0.05 % + 0.05 Ω)
± (0.3 % + 0.05 Ω)
± (1 % + 0.05 Ω)
Ins. resistance > 103 MΩ
± (0.25 % + 0.05 Ω)
± (0.05% + 0.05Ω)
MIL-STD-202
Method 204 - Test D: 20g
10/2000Hz
MIL-STD-202
Method 108 Pn 1000h
MIL-STD-202
Method 106
250 h at + 275 °C
MIL-STD-202
100g Method 205 - Test C
CONDITIONS REQUIREMENTS
MIL-R-26 E NF C 83-210
TYPICAL VALUES
AND DRIFTS
± 50 ppm/°C
± 50 ppm/°C
STABILITY AND POWER RATING
Stability changes slightly according to power rating and ambient temperature. This fact is especially important for users needing
a life drift lower than the initial resistance tolerance. Typical drifts, after 2000h life test made under the 90’/30’ conditions
and at an ambient temperature of 25°C, are:
OHMIC RANGE LIMITS
± 100 ppm/°C
NF C MIL
± 90 ppm/°C
± 30 ppm/°C + 0 to – 20 ppm/°C
TYPICAL VALUE
± 50 ppm/°C
± 25 ppm/°C
< 1 Ω
1 Ω to < 10 Ω
10 Ω
INDUCTANCE (Example)
FREQUENCY IN MHz
INDUCTANCE IN µH
1.4
1.3
1.2
1.1
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0.1 1 10
RLP3 100 Ω
RLP3 NI 100 Ω
PERFORMANCE
RLP1
Pn
0.5Pn
1 W
0.5 W
2 W
1 W
3 W
1.5 W
5 W
2.5 W
10 W
5 W
0.3
0.15
RLP2 RLP3 RLP6 RLP10 ΔR %
R %
Insulated Precision Wirewound Resistors
Axial Leads
TEMPERATURE COEFFICIENT IN THE RANGE - 55° + 200 °C
± (0.1 % + 0.05 Ω)
www.vishay.com
43
RLP
Vishay Sfernice
Document Number: 50009
Revision 03-Mar-06
For technical questions, contact sfer@vishay.com
POWER RATING CHART
TEMPERATURE RISE
RATED POWER IN WATTS
HOT SPOT TEMPERATURE IN C°
250
200
150
100
50
0
0 1.5 3 4.5 6 7.5 10
RLP2
RLP1
RLP3
RLP6
RLP10
MARKING
SFERNICE trademark, series, style, CECC style (if applicable) nominal resistance (in Ω, kΩ), tolerance (in %), manufacturing
date.
3
NON INDUCTIVE
WINDING
STYLE SPECIAL
DESIGN
MODEL
RLP
TOLERANCE
± 1 %
PACKAGING
Optional
Method N°
Optional
Optional
OHMIC VALUE
4.7 kΩ
ORDERING INFORMATION
Custom items are subject to
extra-charge and min. order.
Please see price list.
Insulated Precision Wirewound Resistors
Axial Leads
AMBIENT TEMPERATURE IN DEGREES CELSIUS
% RATED POWER
125
100
75
50
37
25
0
0 50 100 150 200 250 275 300 350
(NI)
Legal Disclaimer Notice
Vishay
Document Number: 91000 www.vishay.com
Revision: 08-Apr-05 1
Notice
Specifications of the products displayed herein are subject to change without notice. Vishay Intertechnology, Inc.,
or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies.
Information contained herein is intended to provide a product description only. No license, express or implied, by
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Vishay's
terms and conditions of sale for such products, Vishay assumes no liability whatsoever, and disclaims any express
or implied warranty, relating to sale and/or use of Vishay products including liability or warranties relating to fitness
for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications.
Customers using or selling these products for use in such applications do so at their own risk and agree to fully
indemnify Vishay for any damages resulting from such improper use or sale.