INFINITY(R) METERS (R) (R) 6 Digits NEMA-4 (IP65) Front Bezel Four Isolated Open Collector Outputs Digital Tare 1.5 to 11 or 24 Vdc Sensor Excitation Peak and Valley Detection and Memory On-board excitation is included so you can power virtually any sensor or transmitter, and four standard setpoints give the flexibility to control or alarm your system completely. SPECIFICATIONS Accuracy: 0.005% rdg Span Temperature Coefficient: 20 ppm Step Response: 1 sec to 99.9% Power: 115 or 230 Vac, 49-400 Hz; 10 to 32 Vdc Normal Mode Rejection: 60 dB Common Mode Rejection: 120 dB Common Mode Voltage: 1500 V peak per Hv test Resolution: 17-bit Reading Rate: 3/sec or 13/sec, 60 Hz; 3/sec or 12/sec, 50 Hz Display: red or green 6-digit, 14-segment, 13.7 mm (0.54"); 4 alarm indicators Panel Cutout: 45 H x 92 W mm (1.772 x 3.622"); 1/8 DIN Open Collector Outputs: four, isolated open collector; rated 150 mA at 1 V sink, 30 V open BCD Output: isolated, tri-state, TTL/CMOS compatible; external 5 V supply required for isolated; internal 5 V supply for non-isolated The NEWPORT(R) 6-Digit INFINITY(R) family of digital panel meter/controllers represents the world standard for accuracy and quality in industrial instrumentation. Select from instruments designed for: PROCESS (DC Voltage and Current), STRAIN GAGE measurements, TEMPERATURE (Thermocouple and RTD), or the INFINITY(R) UNIVERSAL for one meter which covers all the input types. The INFINITY(R) WEIGHT meter is a legal for trade NTEP certified strain meter with enhanced features. INFINITY(R) meters can measure a broad spectrum of dc voltage and current ranges, nine thermocouple types, a variety of RTDs, a multitude of inputs from pressure transducers, load cells, strain gages as well as potentiometric inputs. Six full digits make this meter ideal for demanding process control applications. To Order ( * insert number code to complete model number) Basic Power Control Analog Serial Input Model & Display Output Output Output Signal INFP INFS INFW INFT INFU (*) (*) (*) (*) (*) 0 1 4 (*) (*) (*) (*) (*) (*) (*) (*) (*) (*) (*) (*) (*) (*) (*) (*) (*) (*) (*) (*) 0 1 2 3 0 1 0 1 2 ( ) Input Signal Voltage/Current Range Code Range Range Code Range DC1 0-100 mV DC7 50 mVdc DC2 0-1 Vdc DC8 500 mVdc DC3 0-5 Vdc DC9 5 Vdc DC4 1-5 Vdc DC10 50 Vdc DC5 0-10 Vdc C1 0-20 mA DC6 0-100 Vdc C2 4-20 mA Dual Relays: form C, 7 A at 30 Vdc or 230 Vac Four Relay Option: dual 7 A relays and dual 1 A relays Analog Output: 0-5 V/1-5 V/0-10 V/ 0-20 mA/4-20 mA, user selectable; 354 Vp isolation;15-bit resolution; 0.1% accuracy, 50 msec step response Voltage Input Ranges: 0-100 mV, 0-1 V, 0-5 V, 1-5 V, 0-10 V, 0-100 V, 50 mV, 500 mV, 5 V, 50 V Current Input Ranges: 0-20 mA, 4-20 mA Input Configuration: single-ended Polarity: unipolar/bipolar, programmable Thermocouple Input Types: J, K, T, E, R, S, B, N, J DIN RTD Input: any 6 to 6k NIST or DIN platinum and any linear RTD RTD Connection: 2, 3 or 4-wire Sensor Excitation: 10 V at 30 mA; 24 V at 25 mA Description Process (DC voltage and current) Strain input Weight NTEP handbook 44 legal for trade strain input Temperature (thermocouple and RTD) Universal Inputs (process, strain, & temperature) 115 Vac power, red LED display 230 Vac power, red LED display 10-32 Vdc power, red LED display Four NPN open collector transistors Isolated parallel BCD Two 7 A relays Two 7 A relays and two 1 A relays No analog output Isolated analog output No serial output Isolated RS-232 Isolated RS-485 Specify input signal from charts below Input Signal Thermocouple or RTD J (*) T (*) S (*) RTD1 (*) 10 ohm copper, linear K (*) B (*) N (*) RTD2 (*) 100 ohm pt, 0.00385 alpha E (*) R (*) J-DIN (*) RTD3 (*) 100 ohm pt, 0.00392 alpha * Specify "C" (Celsius), "F" (Farenheit), or "K" (Kelvin)