Specifications
Supply Voltage and Current
85 - 264 V ac; 50 or 60 Hz
Indicators: Max. current per LED color:
· at 85 V ac: 35 mA
· at 120 V ac: 30 mA
· at 240 V ac: 20 mA
· at 264 V ac: 18 mA
Standard Audible Alarm: 30 mA max. current
Sealed Audible Alarm: 35 mA max. current
Omni-Directional Sealed Audible Alarm: 45 mA max. current
Indicators
LEDs are independently selected, 1 to 5 colors depending on model
Supply Protection Circuitry:
Protected against reverse polarity and transient voltages
Input Response Time
Indicator On/Off: 500 ms (max.)
Audible Adjustment
Standard Audible Alarm: Unscrew the cover (up to 1.5 turns max.)
to adjust the audible intensity. Do not exceed 1.5 turns or the cover
may detach during operation. For max. intensity, rotate the center plug
180° counterclockwise to remove it.
Sealed Audible Alarm and Omni-Directional Sealed Audible
Alarm with Intensity Adjustment: Rotate the front cover until the
desired intensity is reached.
Omni-Directional Sealed Audible Alarm: No adjustment.
Leakage Current Immunity
500µA
Application Note: The use of relay output PLC is recommended since
there is no leakage current. Solid state output PLCs often have leakage
current above 1mA and, therefore, turn the light on in the off state. To
counteract the leakage current, a shunt resistor must be used. A
resistor must be applied from the neutral wire of the device to the hot
wire of each channel of the device.
Vibration and Mechanical Shock:
All models meet Mil. Std. 202F requirements method 201A (vibration:
10 to 60 Hz max., double amplitude 0.06 in, maximum acceleration
10G). Also meets IEC 947-5-2; 30G 11 ms duration, half sine wave.
Operating Conditions:
Non-Audible:−40 °C to +50 °C (−40 °F to +122 °F)
Standard and Sealed Audible: −20 °C to +50 °C (−4 °F to +122 °F)
Max. Rel. Humidity: 95% at 50 °C (non-condensing)
Audible Alarm
Standard Audible Alarm: 2.7 KHz ± 500 Hz oscillation frequency;
max. intensity 92 db at 1 m (3.3 ft) (typical)
Sealed Audible Alarm: 2.9 KHz ± 250 Hz oscillation frequency; max.
intensity 94 db at 1 m (3.3 ft) (typical)
Omni-Directional Sealed Audible Alarm: 2.1 KHz ± 250 Hz
oscillation frequency; max intensity 99 db at 1m (3.3 ft) (typical)
Omni-Directional Sealed Audible Alarm with Intensity
Adjustment: 2.1 KHz ± 250 Hz oscillation frequency; max intensity 95
dB at 1m (3.3 ft) (typical)
Construction:
Bases and Covers: ABS
Light Segment: Polycarbonate
Connections
4-wire, 5-wire, or 6-wire 2m (6.5 ft) integral cable; 4-pin or 5-pin 150
mm (5.9 in) PVC pigtail with QD, depending on model
Environmental Rating
Non-Audible and Sealed Audible: IEC IP67
Standard Audible: IEC IP50
Certifications
Dimensions
# of
Colors
Tower Height (H)
Non-Audible Standard Audible* Sealed Audible Omni-Directional
Sealed Audible
1 130.2 mm (5.1 in) 161.0 mm (6.3 in) 184.1 mm (7.2 in) 198.1 mm (7.8 in)
2 170.9 mm (6.7 in) 201.7 mm (7.9 in) 224.8 mm (8.9 in) 238.8 mm (9.4 in)
3 211.6 mm (8.3 in) 242.4 mm (9.5 in) 265.5 mm (10.5 in) 279.5 mm (11.0 in)
4 252.3 mm (9.9 in) 283.1 mm (11.1 in) 306.2 mm (12.1 in) 320.2 mm (12.6 in)
5 293.0 mm (11.5 in) - - -
* Tower height (H) with top unscrewed approximately 3.5 mm to allow sound to escape
EZ-LIGHT® TL50 Universal AC Voltage Tower Light
P/N 169421 Rev. C www.bannerengineering.com - tel: 763-544-3164 3