A1
REVISIONS
0 PLC
1 PLC
2 PLC
3 PLC
4 PLC
ANGLES
OF
SCALE SHEET REV
NAME
SIZE CAGE CODE DRAWING NO
DIMENSIONS: TOLERANCES UNLESS
OTHERWISE SPECIFIED:
DWN
CHK
APVD
MATERIAL FINISH
PRODUCT SPEC
APPLICATION SPEC
WEIGHT
P LTR DATE APVD
DWNDESCRIPTION
5
67
8 34 2 1
D
B
A
A
B
CC
D
ALL RIGHTS RESERVED.
RELEASED FOR PUBLICATION
CCOPYRIGHT
THIS DRAWING IS UNPUBLISHED.
4805 (3/13)
RESTRICTED TO
THIS DRAWING IS A CONTROLLED DOCUMENT.
TE Connectivity
1
2
3
5
6
8
9
10
11
CUSTOMER DRAWING
555844
L. SMITH
15DEC2006
L. SMITH
15FEB2007
F. LINCOLN
15FEB2007
2:1 1 2 D
-
-
-
- -
MM[INCHES]
-
-
-
-
-
-
J-BOX AND MULTI-PLEX ASSEMBLY,
5 WIRE, STD
-
-
20
- -
20
00779
BY -
DECO-14-007817
29MAY2014
JM SJ
246.9
9.72[ ]
42.7
1.68[ ]
127
5.00[ ]
81.3
3.20[ ]
45.7
1.80[ ]
55.9
2.20[ ]
71.1
2.80[ ]
15.2
.60[ ]
62.9
2.48[ ]
47.1
1.86[ ]
PART NUMBER
555844-1
MATES WITH POWER CONNECTOR HARNESS
ASSEMBLY, PART NUMBER 555888-( ),
555829-1 THROUGH 555830-1.
KEYING FEATURE FOR POSITIVE MATING.
POSITIVE LATCHING TO POWER CONNECTOR.
4. 125/250 V, 20A RATING FOR RU.
125/250 V, 20A RATING FOR CSA.
MATERIAL: HOUSING - POLYCARBONATE,
BLACK, 94V-0 RATED.
END CAP- POLYCARBONATE, SOFT WHITE.
94V-0 RATED.
DUST COVER - NYLON 6/6.
CONTACT - COPPER ALLOY, SELECTIVE
SILVER PLATED 3.81µm [.000150] MINIMUM
THICK.
ALL DIMENSIONS ARE NOMINAL UNLESS
OTHERWISE SPECIFIED.
7. DIMENSIONS IN BRACKETS ARE IN INCHES.
THIS AREA OF THE JUNCTION BOX MATES
WITH AMPINNERGY DUPLEX RECEPTACLES.
SUGGESTED PANEL MOUNTING CUT-OUT FOR
JUNCTION BOX. ALLOW 12.7 [.500]
CLEARANCE TOP AND BOTTOM.
REMOVE DUST COVER, BY GENTLY LIFTING
LATCH TO ALLOW CONNECTION OF POWER
CONNECTORS.
JUNCTION BOX MOUNTING WILL ACCEPT A
12 THRU 16 GAGE THICK SHEET METAL.
12. APPLICATION: IN LINE OR END OF LINE
JUNCTION BOX ASSEMBLY. UP TO FOUR
DUPLEX RECEPTACLES NEMA TYPE 5-15R
125V, 2 POLE, 3 WIRE, 15 AMPERE AND/OR
5-20R 125V, 2 POLE, 3 WIRE, 20 AMPERE
RECEPTACLES CAN BE INSTALLED INTO
JUNCTION BOX ASSEMBLY. RECEPTACLES CAN
BE INDIVDUALLY REPLACED WITH DIFFERENT
LINE RECEPTACLES TO BALANCE LOADS.
ASSEMBLY IS DESIGNED TO PROVIDE IN
LINE OR END OF LINE DISTRIBUTION OF
POWER WHEN USED WITH AMPINNERGY-
MODULAR WIRING SYSTEM, A MANUFACTURED
WIRING SYSTEM.
J2
J1
J4
J3
END CAP
DUST COVER
QUANITY 4
SCALE 1:1
6
5 5
ELECTRICAL POWER STRIP SCHEMATIC FOR
555844-1
12678
1 2 678
G N L1 L2 L3
J2
J4
12678
1 2 678
G N L1 L2 L3
J1
J3
AMPINNERGY STYLE - NEMA
TYPE 15R AND 20R
DUPLEX RECEPTACLE
FRONT PLUG-IN CAPABILITY
2 PLACES
AMPINNERGY STYLE - NEMA
TYPE 15R AND 20R
DUPLEX RECEPTACLE
FRONT PLUG-IN CAPABILITY
2 PLACES
"FRONT' "FRONT'
5 WIRE
3
8
1
10
2