30 MICA
03/20192
*a marking: number of poles
*b connector mated with tab header
*c flat cable
*d locking
*e tab header MICS…
*f printed circuit board
Environmental conditions
Temperature range -40 °C/+120 °C 1
1 upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card
Materials
Insulating body PBT, V-0 according to UL94
Contact spring CuSn, tin-plated – MICA
CuSn, gold-plated in contact area,
tin-plated in insulation
displacement area – MICA SEL 0,8
AU
Mechanical data
Insertion force/contact < 0,8 N
Withdrawal force/contact > 0,4 N
Connectable conductors for IDT area
Construction flat cable 1.27 mm
Section min. AWG 28 (0,080 mm²)
Section max. AWG 26 (0,140 mm²)
Insulation diameter 1,0 mm
Approved cables at www.lumberg.com �at www.lumberg.com �
Electrical data (at Tamb 20 °C)
Contact resistance ≤ 10 mΩ
Rated current 1,2 A
Rated voltage 32 V AC
(250 V AC ohne Berücksichtigung
der Kriech- und Luftstrecken nach
IEC 60664/DIN EN 60664) 1
Material group IIIa (IEC)/3 (UL) (CTI ≥ 175)
Creepage distance 0,54 mm
Clearance 0,54 mm
Insulation resistance > 1 GΩ
1 32 V AC
(250 V AC without considering creepage distance and clearance of IEC 60664/DIN EN 60664)
Associated products
Accessories
� AZ30
Harnessing equipment
� HZ-M30 � HZ30 � KHP30
� PP30 � VARICON 1000
of 4