LM SERIES LIQUID LEVEL SENSOR
TE CONNECTIVITY SENSORS /// LM 12/2019
STANDARD RANGES
Note: Intermediate pressure ranges available.
PERFORMANCE SPECIFICATIONS
Supply Voltage: 5.0Vdc
Ambient Temperature: 25°C (unless otherwise specified)
Accuracy (combined linearity, hysteresis, & repeatability)
Total Error Band (includes calibration errors
above & temperature effects over the
compensated range)
Insulation Resistance (50Vdc)
Tightening Torque (recommended)
1~2 Turns from Finger Tight
Zero Offset Effect @ 1psiG from 90° Changes due to
Installation Orientation
Liquids and Gases compatible with PVC, 316/316L ST STL, Buna-N O-Ring
Notes
1. Ratiometric to supply voltage.
2. Measured at vacuum for Absolute (A), ambient for Gage (G) and Sealed Gage (S).
3. Best fit straight line.
4. Minimum from any wire to metal diaphragm.
5. The maximum pressure that can be applied without changing the transducer’s performance or accuracy
6. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer.
7. Over-torquing will damage the PVC fitting and will cause sensor calibration and/or zero offset to shift during installation.
Always check for a zero-offset shift after installing.
8. Zero offset effect is inversely ratiometric to pressure range, for 2psiG: 0.3% Span (typ); for 5psiG: 0.12% Span (typ).
Additional Notes
9. Standard gage units are not recommended for vacuum applications.
10. Direct mechanical contact with diaphragm is prohibited. Diaphragm surface must remain free of defects (scratches,
punctures, dents, fingerprints, etc.) for device to operate properly. Caution is advised when handling parts with exposed
diaphragms. Use protective cap whenever devices are not in use.