Electrical data
Primary nominal Primary current Primary Conductor Type
r.m.s. current measuring range Diameter
IPN (A) IP (A) (mm)
7.5 ± 19 1.1 HAW 07-P
VCSupply voltage (± 5 %) ± 15 V
I CCurrent consumption <± 18 mA
VdR.m.s. voltage for AC isolation test, 50/60Hz, 1 mn 2.0 kV
R IS Isolation resistance @ 500 VDC > 500 MΩ
VOUT Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C ±4 V
ROUT Output internal resistance 100 Ω
R LLoad resistance >10 kΩ
Accuracy-Dynamic performance data
XAccuracy @ IPN, TA = 25°C (without offset) < ± 1 % of IPN
εεLLinearity (0 .. ± IPN)< ± 1 % of IPN
VOE Electrical offset voltage, TA = 25°C < ± 40 mV
VOH Hysteresis offset voltage @ IP = 0;
after an excursion of 1 x IPN < ± 20 mV
VOT Thermal drift of VOE max. ± 1.5 mV/K
TCεεGThermal drift of the gain (% of reading) ± 0.1 %/K
t rResponse time @ 90% of IP< 3 µs
fFrequency bandwidth (- 3 dB)1) DC .. 50 kHz
General data
TAAmbient operating temperature - 10 .. + 75 °C
TSAmbient storage temperature - 15 .. + 85 °C
mMass 12 g
Current Transducer HAW 07-P
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 7 A
Features
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation voltage 2000 V
• Low power consumption
• Extended measuring range(2.5x IPN)
Advantages
• Easy mounting
• Small size and space saving
• Only one design for wide current
ratings range
• High immunity to external
interference.
Applications
• DC motor drives
• Switched Mode Power Supplies
(SMPS)
• AC variable speed drives
• Uninterruptible Power Supplies
(UPS)
• Battery supplied applications
• Inverters
Notes : EN 50178 approval pending
LEM Components www.lem.com
010824/1
Preliminary
1) Derating is needed to avoid excessive core heating at high frequency.