Product
Folder
Order
Now
Technical
Documents
Tools &
Software
Support &
Community
Reference
Design
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,
intellectual property matters and other important disclaimers. PRODUCTION DATA.
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
TRF7964A Multiprotocol Fully Integrated 13.56-MHz RFID Reader and Writer IC
1 Device Overview
1
1.1 Features
1
Completely Integrated Protocol Handling for
ISO/IEC 15693, ISO/IEC 18000-3, ISO/IEC 14443
A and B, and FeliCa™
Integrated State Machine for ISO/IEC 14443 A
Anticollision (Broken Bytes) Operation
Input Voltage Range: 2.7 VDC to 5.5 VDC
Programmable Output Power: +20 dBm (100 mW),
+23 dBm (200 mW)
Programmable I/O Voltage Levels From 1.8 VDC
to 5.5 VDC
Programmable System Clock Frequency Output
(RF, RF/2, RF/4) from 13.56-MHz or 27.12-MHz
Crystal or Oscillator
Integrated Voltage Regulator Output for Other
System Components (MCU, Peripherals,
Indicators), 20 mA (Max)
Programmable Modulation Depth
Dual Receiver Architecture With RSSI for
Elimination of "Read Holes" and Adjacent Reader
System or Ambient In-Band Noise Detection
Programmable Power Modes for Ultra Low-Power
System Design (Power Down <1 µA)
Parallel or SPI Interface (With 127-Byte FIFO)
Temperature Range: –40°C to 110°C
32-Pin QFN Package (5 mm × 5 mm)
1.2 Applications
Public Transport or Event Ticketing
Passport or Payment (POS) Reader Systems
Product Identification or Authentication
Medical Equipment or Consumables
Access Control, Digital Door Locks
1.3 Description
The TRF7964A device is an integrated analog front end (AFE) and multiprotocol data-framing device for a
13.56-MHz NFC/RFID reader and writer system supporting ISO/IEC 14443 A and B, Sony FeliCa, and
ISO/IEC 15693. Pin-to-pin and firmware compatible with the superset device TRF7970A. Built-in
programming options make the device suitable for a wide range of applications for proximity and vicinity
identification systems.
The device is configured by selecting the desired protocol in the control registers. Direct access to all
control registers allows fine tuning of various reader parameters as needed.
The TRF7964A device supports data rates up to 848 kbps with all framing and synchronization tasks for
the ISO protocols onboard. Other standards and even custom protocols can be implemented by using one
of the direct modes the device offers. These direct modes let the user fully control the AFE and also gain
access to the raw subcarrier data or the unframed, but already ISO-formatted, data and the associated
(extracted) clock signal.
The receiver system has a dual-input receiver architecture to maximize communication robustness. The
receivers also include various automatic and manual gain control options. The received signal strength
from transponders, ambient sources, or internal levels is available in the RSSI register.
A SPI or parallel interface can be used for the communication between the MCU and the TRF7964A
device. When the built-in hardware encoders and decoders are used, transmit and receive functions use a
127-byte FIFO register. For direct transmit or receive functions, the encoders or decoders can be
bypassed so the MCU can process the data in real time.
The TRF7964A device supports a wide supply voltage range of 2.7 V to 5.5 V and data communication
levels from 1.8 V to 5.5 V for the MCU I/O interface.
The transmitter has selectable output power levels of 100 mW (+20 dBm) or 200 mW (+23 dBm)
equivalent into a 50-Ωload when using a 5-V supply and supports OOK and ASK modulation with
selectable modulation depth.
MUX
RX_IN1
RX_IN2
Phase and
Amplitude
Detector
Gain RSSI
(AUX)
Logic
Level Shifter
State
Control
Logic
(Control
Registers and
Command
Logic)
127-Byte
FIFO
MCU
Interface
VDD_I/O
I/O_0
I/O_1
I/O_2
I/O_3
I/O_4
I/O_5
I/O_6
I/O_7
IRQ
SYS_CLK
DATA_CLK
ISO
Protocol
Handling Decoder
RSSI
(External)
Gain
RSSI
(Main)
Filter
and AGC Digitizer
Bit
Framing
Framing
Serial
Conversion
CRC and Parity
Transmitter
Analog Front End
TX_OUT
VDD_PA
VSS_PA
Digital Control
State Machine
Crystal or Oscillator
Timing System
EN
EN2
ASK/OOK
MOD
OSC_IN
OSC_OUT
Voltage Supply Regulator Systems
(Supply Regulators and Reference Voltages)
VSS_A
VSS_RF
VDD_RF
VDD_X
VSS_D
VSS
VIN
VDD_A
BAND_GAP
RF Level
Detector
Phase and
Amplitude
Detector
Copyright © 2017, Texas Instruments Incorporated
2
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Device Overview Copyright © 2012–2017, Texas Instruments Incorporated
The built-in programmable auxiliary voltage regulator delivers up to 20 mA to supply an MCU and
additional external circuits within the reader system.
Start evaluating the TRF7964A multiprotocol transceiver IC with the TRF7970AEVM,TRF7970ATB, or
DLP-7970ABP of the superset device.
Device Information
PART NUMBER PACKAGE BODY SIZE
TRF7964ARHB VQFN (32) 5 mm × 5 mm
1.4 Functional Block Diagram
Figure 1-1 shows the block diagram.
Figure 1-1. Block Diagram
3
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Table of ContentsCopyright © 2012–2017, Texas Instruments Incorporated
Table of Contents
1 Device Overview ......................................... 1
1.1 Features .............................................. 1
1.2 Applications........................................... 1
1.3 Description............................................ 1
1.4 Functional Block Diagram ............................ 2
2 Revision History ......................................... 4
3 Device Characteristics.................................. 5
3.1 Related Products ..................................... 5
4 Terminal Configuration and Functions.............. 6
4.1 Pin Diagram .......................................... 6
4.2 Signal Descriptions................................... 6
5 Specifications ............................................ 8
5.1 Absolute Maximum Ratings .......................... 8
5.2 ESD Ratings.......................................... 8
5.3 Recommended Operating Conditions................ 8
5.4 Electrical Characteristics ............................. 9
5.5 Thermal Resistance Characteristics ................ 10
5.6 Switching Characteristics ........................... 10
6 Detailed Description ................................... 11
6.1 Overview ............................................ 11
6.2 System Block Diagram.............................. 12
6.3 Power Supplies...................................... 12
6.4 Receiver Analog Section.......................... 18
6.5 Receiver Digital Section........................... 19
6.6 Oscillator Section ................................... 24
6.7 Transmitter Analog Section ....................... 25
6.8 Transmitter Digital Section........................ 26
6.9 Transmitter External Power Amplifier and
Subcarrier Detector ................................. 27
6.10 TRF7964A IC Communication Interface ............ 27
6.11 TRF7964A Initialization ............................. 45
6.12 Special Direct Mode for Improved MIFARE™
Compatibility......................................... 46
6.13 Direct Commands from MCU to Reader ............ 46
6.14 Register Description................................. 49
7 Applications, Implementation, and Layout........ 67
7.1 TRF7964A Reader System Using SPI With SS
Mode ................................................ 67
7.2 Layout Considerations .............................. 68
7.3 Impedance Matching TX_Out (Pin 5) to 50 ...... 68
7.4 Reader Antenna Design Guidelines ................ 69
8 Device and Documentation Support ............... 70
8.1 Getting Started and Next Steps..................... 70
8.2 Device Nomenclature ............................... 70
8.3 Tools and Software ................................. 71
8.4 Documentation Support............................. 71
8.5 Community Resources.............................. 72
8.6 Trademarks.......................................... 72
8.7 Electrostatic Discharge Caution..................... 72
8.8 Glossary............................................. 72
9 Mechanical, Packaging, and Orderable
Information .............................................. 73
4
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Revision History Copyright © 2012–2017, Texas Instruments Incorporated
2 Revision History
NOTE: Page numbers for previous revisions may differ from page numbers in the current version.
Changes from April 18, 2014 to March 27, 2017 Page
Changed the contents of Section 1.3,Description ............................................................................... 1
Added Section 3.1,Related Products ............................................................................................. 5
Moved TSTG from Section 5.2 to Section 5.1,Absolute Maximum Ratings ................................................... 8
Moved Section 5.2 and changed title from Handling Ratings to ESD Ratings ............................................... 8
Added VOL and VOH to Section 5.4,Electrical Characteristics ................................................................. 9
Changed the TYP value of the fD_CLKmax parameter from 8 to 4 MHz in Section 5.4,Electrical Characteristics ........ 9
Throughout document, removed support for application control of Automatic Gain Control (AGC) and Receiver
Gain Adjust, because these features were designed for test functionality and not for production use.................. 11
Added the sentence that starts "For applications in which the TRF7964A may be subjected..." in the second
paragraph of Section 6.3,Power Supplies....................................................................................... 12
Changed VDD_A to VDD_X in the last sentence that reads "The VDD_X output current should not exceed 20 mA." in
the NOTE in Analog Supply Regulator: VDD_A................................................................................... 13
Removed the paragraph that started "The RF power amplifier regulator..." from Digital Supply Regulator: VDD_X .... 13
Changed 250 mV to 400 mV in "...a "Delta Voltage" of 400 mV below VIN..." .............................................. 13
Added the paragraph that starts "As VDD_RF is increased, the system..." in Section 6.3.2,Supply Regulator
Settings .............................................................................................................................. 15
Removed the paragraphs that started "The main receiver also has..." and "By default, the AGC window
comparator..." from Section 6.4.2,Receiver Gain and Filter Stages ........................................................ 18
Changed Table 6-5 to match Table 6-31......................................................................................... 19
Updated Section 6.5,Receiver Digital Section, to clarify and remove duplicate content................................ 19
Updated the description in Section 6.5.1.2,External RSSI.................................................................... 23
Removed "Equivalent Series Resistance" from Table 6-8,Minimum Crystal Recommendations........................ 25
Removed mention of 3-wire SPI and replaced "IRQ" with "Slave Select" in the first paragraph of Section 6.10.1,
General Introduction ................................................................................................................ 27
Updated the description of FIFO level interrupts in Section 6.10.1.4,FIFO Operation.................................... 31
Added "but recommended" to "It is optional but recommended to read the FIFO Status register..." in
Section 6.10.3,Reception of Air Interface Data................................................................................. 33
Changed the title of Section 6.10.4,Data Transmission From MCU to TRF7964A........................................ 34
Removed the sentence that started "The choice of one of these modes over another..." from Section 6.10.5,
Serial Interface Communication (SPI)............................................................................................ 34
Updated the paragraph that starts "TI recommends resetting the FIFO after receiving data..." in
Section 6.10.5.1,Serial Interface Mode With Slave Select (SS).............................................................. 39
Added the NOTE that starts "An additional direct mode..." in Section 6.10.6,Direct Mode............................... 40
Added Section 6.11,TRF7964A Initialization ................................................................................... 45
Changed the application report that is referenced in Section 6.12,Special Direct Mode for Improved MIFARE
Compatibility ......................................................................................................................... 46
Added and updated comments in Table 6-14,Address and Command Word Bit Distribution............................ 46
Added the sentence that starts "This command should be sent after a Software Initialization command..." in
Section 6.13.1.1,Idle (0x00)....................................................................................................... 46
Removed unsupported registers (addresses 0x15 to 0x19) in Table 6-16,Register Values After Sending
Software Initialization (0x03)....................................................................................................... 47
Added "This is used by the ISO/IEC 15693 protocol" to Section 6.13.1.8,Transmit Next Time Slot (0x14)............ 48
Corrected description of B1 Irq_col in Table 6-37,IRQ Status Register (0x0C): changed from "(as defined in
register 0x01)" to "(as defined in register 0x10)" ............................................................................... 60
Changed the description of B5:B3 in Table 6-40 from "...Auxiliary RSSI represents the signal level at RX_IN2" to
"...Auxiliary RSSI represents the signal level at RX_IN1"...................................................................... 62
Removed former Section 7.1, TRF7964A Reader System Using Parallel Microcontroller Interface..................... 67
Updated the description in Section 7.1.2,Schematic .......................................................................... 67
Added Section 8.1,Getting Started and Next Steps ........................................................................... 70
Added Section 8.2,Device Nomenclature ....................................................................................... 70
Added Section 8.3,Tools and Software.......................................................................................... 71
Updated Section 8.4,Documentation Support .................................................................................. 71
5
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Device CharacteristicsCopyright © 2012–2017, Texas Instruments Incorporated
3 Device Characteristics
Table 3-1 lists the supported modes of operation for the TRF7964A device.
Table 3-1. Supported Protocols
SUPPORTED PROTOCOLS
ISO/IEC 14443 A and B ISO/IEC 15693,
ISO/IEC 18000-3
(Mode 1)
FeliCa
106 kbps 212 kbps 424 kbps 848 kbps 212 kbps, 424 kbps
3.1 Related Products
For information about other devices in this family of products or related products, see the following links.
Products for TI Wireless Connectivity Connect more with the industry’s broadest wireless connectivity
portfolio.
Products for NFC / RFID TI provides one of the industry’s most differentiated NFC and RFID product
portfolios and is your solution to meet a broad range of NFC connectivity and RFID
identification needs.
Companion Products for TRF7964A Review products that are frequently purchased or used with this
product.
Reference Designs for TRF7964A The TI Designs Reference Design Library is a robust reference
design library that spans analog, embedded processor, and connectivity. Created by TI
experts to help you jump start your system design, all TI Designs include schematic or block
diagrams, BOMs, and design files to speed your time to market. Search and download
designs at ti.com/tidesigns.
VDD_A
VIN
VDD_RF
VDD_PA
TX_OUT
VSS_PA
VSS_RX
RX_IN1
I/O_7
RX_IN2
VSS
BG
ASK/OOK
IRQ
MOD
VSS_A
VDD_I/O
Pad
VDD_X
OSC_IN
OSC_OUT
VSS_D
EN
SYS_CLK
DATA_CLK
EN2
1
2
3
4
5
6
7
8
24
23
22
21
20
19
18
17
9 10 11 12 13 14 15 16
32 31 30 29 28 27 26 25
I/O_6
I/O_5
I/O_4
I/O_3
I/O_2
I/O_1
I/O_0
6
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Terminal Configuration and Functions Copyright © 2012–2017, Texas Instruments Incorporated
(1) SUP = Supply, INP = Input, BID = Bidirectional, OUT = Output
4 Terminal Configuration and Functions
4.1 Pin Diagram
Figure 4-1 shows the pinout for the 32-pin RHB package.
Figure 4-1. 32-Pin RHB Package (Top View)
4.2 Signal Descriptions
Table 4-1 describes the signals.
Table 4-1. Terminal Functions
TERMINAL TYPE (1) DESCRIPTION
NAME NO.
VDD_A 1 OUT Internal regulated supply (2.7 V to 3.4 V) for analog circuitry
VIN 2 SUP External supply input to chip (2.7 V to 5.5 V)
VDD_RF 3 OUT Internal regulated supply (2.7 V to 5 V), normally connected to VDD_PA (pin 4)
VDD_PA 4 INP Supply for PA; normally connected externally to VDD_RF (pin 3)
TX_OUT 5 OUT RF output (selectable output power, 100 mW or 200 mW, with VDD = 5 V)
VSS_PA 6 SUP Negative supply for PA; normally connected to circuit ground
VSS_RX 7 SUP Negative supply for RX inputs; normally connected to circuit ground
RX_IN1 8 INP Main RX input
RX_IN2 9 INP Auxiliary RX input
VSS 10 SUP Chip substrate ground
BAND_GAP 11 OUT Bandgap voltage (VBG = 1.6 V); internal analog voltage reference
ASK/OOK 12 BID Selection between ASK and OOK modulation (0 = ASK, 1 = OOK) for direct mode 0 or 1.
Can be configured as an output to provide the received analog signal output.
7
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Terminal Configuration and FunctionsCopyright © 2012–2017, Texas Instruments Incorporated
Table 4-1. Terminal Functions (continued)
TERMINAL TYPE (1) DESCRIPTION
NAME NO.
IRQ 13 OUT Interrupt request
MOD 14 INP External data modulation input for direct mode 0 or 1
OUT Subcarrier digital data output (see registers 0x1A and 0x1B)
VSS_A 15 SUP Negative supply for internal analog circuits; connected to GND
VDD_I/O 16 INP Supply for I/O communications (1.8 V to VIN) level shifter. VIN should be never exceeded.
I/O_0 17 BID I/O pin for parallel communication
I/O_1 18 BID I/O pin for parallel communication
I/O_2 19 BID I/O pin for parallel communication
TX enable (in special direct mode)
I/O_3 20 BID I/O pin for parallel communication
TX data (in special direct mode)
I/O_4 21 BID I/O pin for parallel communication
Slave select signal in SPI mode
I/O_5 22 BID I/O pin for parallel communication
Data clock output in direct mode 1 and special direct mode
I/O_6 23 BID I/O pin for parallel communication
MISO for serial communication (SPI)
Serial bit data output in direct mode 1 or subcarrier signal in direct mode 0
I/O_7 24 BID I/O pin for parallel communication.
MOSI for serial communication (SPI)
EN2 25 INP Selection of power down mode. If EN2 is connected to VIN, then VDD_X is active during power
down mode 2 (for example, to supply the MCU).
DATA_CLK 26 INP Data clock input for MCU communication (parallel and serial)
SYS_CLK 27 OUT
If EN = 1 (EN2 = don't care) the system clock for MCU is configured. Depending on the crystal
that is used, options are as follows (see register 0x09):
13.56-MHz crystal: Off, 3.39 MHz, 6.78 MHz, or 13.56 MHz
27.12-MHz crystal: Off, 6.78 MHz, 13.56 MHz, or 27.12 MHz
If EN = 0 and EN2 = 1, then system clock is set to 60 kHz
EN 28 INP Chip enable input (If EN = 0, then chip is in sleep or power-down mode).
VSS_D 29 SUP Negative supply for internal digital circuits
OSC_OUT 30 OUT Crystal or oscillator output
OSC_IN 31 INP Crystal or oscillator input
OUT Crystal oscillator output
VDD_X 32 OUT Internally regulated supply (2.7 V to 3.4 V) for digital circuit and external devices (for example,
an MCU)
Thermal Pad PAD SUP Chip substrate ground
8
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Specifications Copyright © 2012–2017, Texas Instruments Incorporated
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions are not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to substrate ground terminal VSS.
(3) The maximum junction temperature for continuous operation is limited by package constraints. Operation above this temperature may
result in reduced reliability or lifetime of the device.
5 Specifications
5.1 Absolute Maximum Ratings(1) (2)
over operating free-air temperature range (unless otherwise noted) MIN MAX UNIT
VIN Input voltage range –0.3 6 V
IIN Maximum current VIN 150 mA
TJMaximum operating virtual junction temperature Any condition 140 °C
Continuous operation, long-term reliability(3) 125 °C
TSTG Storage temperature –55 150 °C
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process. Pins listed as ±2000
V may actually have higher performance.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process. Pins listed as ±500 V
may actually have higher performance.
5.2 ESD Ratings
VALUE UNIT
V(ESD) Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001, all pins(1) ±2000 V
Charged-device model (CDM), per JEDEC specification JESD22-C101, all
pins(2) ±500 V
Machine model (MM) ±200 V
5.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted) MIN TYP MAX UNIT
VIN Operating input voltage 2.7 5 5.5 V
TAOperating ambient temperature –40 25 110 °C
TJOperating virtual junction temperature –40 25 125 °C
VIL Input voltage, logic low I/O lines, IRQ, SYS_CLK, DATA_CLK,
EN, EN2, ASK/OOK, MOD 0.2 ×
VDD_I/O V
VIH Input voltage threshold, logic high I/O lines, IRQ, SYS_CLK, DATA_CLK,
EN, EN2, ASK/OOK, MOD 0.8 ×
VDD_I/O V
9
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
SpecificationsCopyright © 2012–2017, Texas Instruments Incorporated
(1) Antenna driver output resistance
(2) Measured with subcarrier signal at RX_IN1 or RX_IN2 and measured the digital output at MOD pin with register 0x1A bit 6 = 1.
(3) Depends on the crystal parameters and components
(4) TI recommends a DATA_CLK speed of 2 MHz. Higher data clock depends on the capacitive load. Maximum SPI clock speed should not
exceed 10 MHz. This clock speed is acceptable only when external capacitive load is less than 30 pF. MISO driver has a typical output
resistance of 400 Ω(12-ns time constant when 30-pF load used).
5.4 Electrical Characteristics
TYP operating conditions are TA= 25°C, VIN = 5 V, full-power mode (unless otherwise noted)
MIN and MAX operating conditions are over recommended ranges of supply voltage and operating free-air temperature
(unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
VOL Low-level output voltage 0.2 ×
VDD_I/O V
VOH High-level output voltage 0.8 ×
VDD_I/O V
IPD1 Supply current in power down mode 1 All building blocks disabled, including
supply-voltage regulators; measured after
500-ms settling time (EN = 0, EN2 = 0) 0.5 5 µA
IPD2 Supply current in power down mode 2
(sleep mode)
The SYS_CLK generator and VDD_X
remain active to support external circuitry;
measured after 100-ms settling time
(EN = 0, EN2 = 1) 120 200 µA
ISTBY Supply current in stand-by mode Oscillator running, supply-voltage
regulators in low-consumption mode
(EN = 1, EN2 = x) 1.9 3.5 mA
ION1 Supply current without antenna driver
current Oscillator, regulators, RX and AGC
active, TX is off 10.5 14 mA
ION2 Supply current, TX (half power) Oscillator, regulators, RX and AGC and
TX active, POUT = 100 mW 70 78 mA
ION3 Supply current, TX (full power) Oscillator, regulators, RX and AGC and
TX active, POUT = 200 mW 130 150 mA
VPOR Power-on-reset voltage Input voltage at VIN 1.4 2 2.6 V
VBG Bandgap voltage (pin 11) Internal analog reference voltage 1.5 1.6 1.7 V
VDD_A Regulated output voltage for analog
circuitry (pin 1) VIN = 5 V 3.1 3.4 3.8 V
VDD_X Regulated supply for external circuitry Output voltage pin 32, VIN = 5 V 3.1 3.4 3.8 V
IVDD_Xmax Maximum output current of VDD_X Output current pin 32, VIN = 5 V 20 mA
RRFOUT Antenna driver output resistance (1) Half-power mode, VIN = 2.7 V to 5.5 V 8 12 Ω
Full-power mode, VIN = 2.7 V to 5.5 V 4 6
RRFIN RX_IN1 and RX_IN2 input resistance 4 10 20 kΩ
VRF_INmax Maximum RF input voltage at RX_IN1
and RX_IN2 VRF_INmax should not exceed VIN 3.5 Vpp
VRF_INmin Minimum RF input voltage at RX_IN1
and RX_IN2 (input sensitivity)(2) fSUBCARRIER = 424 kHz 1.4 2.5 mVpp
fSUBCARRIER = 848 kHz 2.1 3
fSYS_CLK SYS_CLK frequency In power mode 2, EN = 0, EN2 = 1 25 60 120 kHz
fCCarrier frequency Defined by external crystal 13.56 MHz
tCRYSTAL Crystal run-in time Time until oscillator stable bit is set
(register 0x0F)(3) 3 ms
fD_CLKmax Maximum DATA_CLK frequency(4) Depends on capacitive load on the I/O
lines, TI recommends 2 MHz(4) 2 4 10 MHz
ROUT Output resistance I/O_0 to I/O_7 500 800 Ω
RSYS_CLK Output resistance RSYS_CLK 200 400 Ω
10
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Specifications Copyright © 2012–2017, Texas Instruments Incorporated
(1) This data was taken using the JEDEC standard high-K test PCB.
(2) Power rating is determined with a junction temperature of 125°C. This is the temperature at which distortion starts to increase
substantially. Thermal management of the final PCB should strive to keep the junction temperature at or below 125°C for best
performance and long-term reliability.
5.5 Thermal Resistance Characteristics
PACKAGE θJC θJA(1) POWER RATING(2)
TA25°C TA85°C
RHB (32 pin) 31°C/W 36.4°C/W 2.7 W 1.1 W
(1) TI recommends a DATA_CLK speed of 2 MHz. Higher data clock depends on the capacitive load. Maximum SPI clock speed should not
exceed 10 MHz. This clock speed is acceptable only when external capacitive load is less than 30 pF. MISO driver has a typical output
resistance of 400 Ω(12-ns time constant when 30-pF load used).
5.6 Switching Characteristics
TYP operating conditions are TA= 25°C, VIN = 5 V, full-power mode (unless otherwise noted)
MIN and MAX operating conditions are over recommended ranges of supply voltage and operating free-air temperature
(unless otherwise noted)PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
tLO/HI DATA_CLK time high or low, one half of DATA_CLK at
50% duty cycle Depends on capacitive load on the
I/O lines(1) 250 62.5 50 ns
tSTE,LEAD Slave select lead time, slave select low to clock 200 ns
tSTE,LAG Slave select lag time, last clock to slave select high 200 ns
tSTE,DIS Slave select disable time, slave select rising edge to
next slave select falling edge 300 ns
tSU,SI MOSI input data setup time 15 ns
tHD,SI MOSI input data hold time 15 ns
tSU,SO MISO input data setup time 15 ns
tHD,SO MISO input data hold time 15 ns
tVALID,SO MISO output data valid time DATA_CLK edge to MISO valid,
CL30 pF 30 50 75 ns
TRF7964A MCU
(MSP430 or ARM)
Matching
VDD_X VDD_I/O
TX_OUT
RX_IN 1
RX_IN2 VSS VIN
Parallel
or SPI
Supply: 2.7 V to 5.5 V
VDD
VDD
Crystal
13.56 MHz
XIN
11
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
6 Detailed Description
6.1 Overview
6.1.1 RFID Reader and Writer
The is a high-performance 13.56-MHz HF RFID transceiver IC composed of an integrated analog front
end (AFE) and a built-in data framing engine for ISO/IEC 15693, ISO/IEC 14443 A and B, and FeliCa.
This includes data rates up to 848 kbps for ISO/IEC 14443 with all framing and synchronization tasks on
board (in default mode). This architecture lets the customer build a complete cost-effective yet high-
performance multiprotocol 13.56-MHz RFID system together with a low-cost microcontroller.
Other standards and even custom protocols can be implemented by using either of the direct modes that
the device offers. These direct modes (0 and 1) allow the user to fully control the analog front end (AFE)
and also gain access to the raw subcarrier data or the unframed but already ISO formatted data and the
associated (extracted) clock signal.
The receiver system has a dual input receiver architecture. The receivers also include various automatic
and manual gain control options. The received input bandwidth can be selected to cover a broad range of
input subcarrier signal options.
The received signal strength from transponders, ambient sources, or internal levels is available through
the RSSI register. The receiver output is selectable among a digitized subcarrier signal and any of the
integrated subcarrier decoders. The selected subcarrier decoder delivers the data bit stream and the data
clock as outputs.
The TRF7964A also includes a receiver framing engine. This receiver framing engine performs the CRC
or parity check, removes the EOF and SOF settings, and organizes the data in bytes for ISO/IEC 14443 A
and B, ISO/IEC 15693, and FeliCa protocols. Framed data is then accessible to the microcontroller (MCU)
through a 127-byte FIFO register.
Figure 6-1. Application Block Diagram
A parallel or serial interface (SPI) can be used for the communication between the MCU and the
TRF7964A reader. When the built-in hardware encoders and decoders are used, transmit and receive
functions use a 127-byte FIFO register. For direct transmit or receive functions, the encoders and
decoders can be bypassed so that the MCU can process the data in real time. The TRF7964A supports
data communication voltage levels from 1.8 V to 5.5 V for the MCU I/O interface. The transmitter has
selectable output-power levels of 100 mW (+20 dBm) or 200 mW (+23 dBm) equivalent into a 50-Ωload
when using a 5-V supply.
MUX
RX_IN1
RX_IN2
Phase and
Amplitude
Detector
Gain RSSI
(AUX)
Logic
Level Shifter
State
Control
Logic
(Control
Registers and
Command
Logic)
127-Byte
FIFO
MCU
Interface
VDD_I/O
I/O_0
I/O_1
I/O_2
I/O_3
I/O_4
I/O_5
I/O_6
I/O_7
IRQ
SYS_CLK
DATA_CLK
ISO
Protocol
Handling Decoder
RSSI
(External)
Gain
RSSI
(Main)
Filter
and AGC Digitizer
Bit
Framing
Framing
Serial
Conversion
CRC and Parity
Transmitter
Analog Front End
TX_OUT
VDD_PA
VSS_PA
Digital Control
State Machine
Crystal or Oscillator
Timing System
EN
EN2
ASK/OOK
MOD
OSC_IN
OSC_OUT
Voltage Supply Regulator Systems
(Supply Regulators and Reference Voltages)
VSS_A
VSS_RF
VDD_RF
VDD_X
VSS_D
VSS
VIN
VDD_A
BAND_GAP
RF Level
Detector
Phase and
Amplitude
Detector
Copyright © 2017, Texas Instruments Incorporated
12
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
The transmitter supports OOK and ASK modulation with selectable modulation depth. The TRF7964A also
includes a data transmission engine that comprises low-level encoding for ISO/IEC 15693, ISO/IEC 14443
A and B, and FeliCa. Included with the transmit data coding is the automatic generation of Start Of Frame
(SOF), End Of Frame (EOF), Cyclic Redundancy Check (CRC), and parity bits.
Several integrated voltage regulators ensure a proper power-supply noise rejection for the complete
reader system. The built-in programmable auxiliary voltage regulator VDD_X (pin 32), is able to deliver up to
20 mA to supply a microcontroller and additional external circuits within the reader system.
6.2 System Block Diagram
Figure 6-2 shows a block diagram of the TRF7964A.
Figure 6-2. System Block Diagram
6.3 Power Supplies
The TRF7964A positive supply input VIN (pin 2) sources three internal regulators with output voltages
VDD_RF, VDD_A and VDD_X. All regulators use external bypass capacitors for supply noise filtering and must
be connected as indicated in reference schematics. These regulators provide a high power supply reject
ratio (PSRR) as required for RFID reader systems. All regulators are supplied by VIN (pin 2).
The regulators are not independent and have common control bits in register 0x0B for output voltage
setting. The regulators can be configured to operate in either automatic or manual mode (register 0x0B,
bit 7). The automatic regulator setting mode ensures an optimal compromise between PSRR and the
highest possible supply voltage for RF output (to ensure maximum RF power output). The manual mode
allows the user to manually configure the regulator settings. For applications in which the TRF7964A may
be subjected to external noise, manually reducing the regulator settings can improve RF performance.
13
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
6.3.1 Supply Arrangements
Regulator Supply Input: VIN
The positive supply at VIN (pin 2) has an input voltage range of 2.7 V to 5.5 V. VIN provides the supply
input sources for three internal regulators with the output voltages VDD_RF, VDD_A, and VDD_X. External
bypass capacitors for supply noise filtering must be used (per reference schematics).
NOTE
VIN must be the highest voltage supplied to the TRF7964A.
RF Power Amplifier Regulator: VDD_RF
The VDD_RF (pin 3) regulator is supplying the RF power amplifier. The voltage regulator can be set for
either 5-V or 3-V operation. External bypass capacitors for supply noise filtering must be used (per
reference schematics). When configured for 5-V manual-operation, the VDD_RF output voltage can be set
from 4.3 V to 5 V in 100-mV steps. In 3-V manual-operation, the output can be programmed from 2.7 V to
3.4 V in 100-mV steps. The maximum output current capability for 5-V operation is 150 mA and for 3-V
operation is 100 mA.
Analog Supply Regulator: VDD_A
Regulator VDD_A (pin 1) supplies the analog circuits of the device. The output voltage setting depends on
the input voltage and can be set for 5-V and 3-V operation. When configured for 5-V manual-operation,
the output voltage is fixed at 3.4 V. External bypass capacitors for supply noise filtering must be used (per
reference schematics). When configured for 3-V manual-operation, the VDD_A output can be set from 2.7 V
to 3.4 V in 100-mV steps (see Table 6-2).
NOTE
The configuration of VDD_A and VDD_X regulators are not independent from each other. The
VDD_X output current should not exceed 20 mA.
Digital Supply Regulator: VDD_X
The digital supply regulator VDD_X (pin 32) provides the power for the internal digital building blocks and
can also be used to supply external electronics within the reader system. When configured for 3-V
operation, the output voltage can be set from 2.7 to 3.4 V in 100-mV steps. External bypass capacitors for
supply noise filtering must be used (per reference schematics).
NOTE
The configuration of the VDD_A and VDD_X regulators are not independent from each other.
The VDD_X output current should not exceed 20 mA.
By default, the regulators are set in automatic regulator setting mode. In this mode, the regulators are
automatically set every time the system is activated by setting EN input High or each time the automatic
regulator setting bit, B7 in register 0x0B is set to a 1. The action is started on the 0 to 1 transition. This
means that, if the user wants to rerun the automatic setting from a state in which the automatic setting bit
is already high, the automatic setting bit (B7 in register 0x0B) should be changed: 1-0-1.
By default, the regulator setting algorithm sets the regulator outputs to a "Delta Voltage" of 400 mV below
VIN, but not higher than 5 V for VDD_RF and 3.4 V for VDD_A and VDD_A.
14
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
Power Amplifier Supply: VDD_PA
The power amplifier of the TRF7964A is supplied through VDD_PA (pin 4). The positive supply pin for the
RF power amplifier is externally connected to the regulator output VDD_RF (pin 3).
I/O Level Shifter Supply: VDD_I/O
The TRF7964A has a separate supply input VDD_I/O (pin 16) for the built-in I/O level shifter. The supported
input voltage ranges from 1.8 V to VIN, not exceeding 5.5 V. Pin 16 is used to supply the I/O interface pins
(I/O_0 to I/O_7), IRQ, SYS_CLK, and DATA_CLK pins of the reader. In typical applications, VDD_I/O is
directly connected to VDD_X, while VDD_X also supplies the MCU. This ensures that the I/O signal levels of
the MCU match the logic levels of the TRF7964A.
Negative Supply Connections: VSS, VSS_TX, VSS_RX, VSS_A, VSS_PA
The negative supply connections VSS_X of each functional block are all externally connected to GND.
The substrate connection is VSS (pin 10), the analog negative supply is VSS_A (pin 15), the logic negative
supply is VSS_D (pin 29), the RF output stage negative supply is VSS_PA (pin 6), and the negative supply for
the RF receiver VSS_RX (pin 7).
15
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
(1) x = Don't care
6.3.2 Supply Regulator Settings
The input supply voltage mode of the reader needs to be selected. This is done in the Chip Status Control
register (0x00). Bit 0 in register 0x00 selects between 5-V or 3-V input supply voltage. The default
configuration is 5 V, which reflects an operating supply voltage range of 4.3 V to 5.5 V. If the supply
voltage is below 4.3 V, the 3-V configuration should be used.
As VDD_RF is increased, the system can become more susceptible to noise coupling on the RX lines. For
minimum noise coupling, TI recommends using the value of 0x00. For improved range, higher VDD_RF
voltages may be set, but complete system testing is required to determine the value which provides
optimal performance.
The various regulators can be configured to operate in automatic or manual mode. This is done in the
Regulator and I/O Control register (0x0B), as shown in Table 6-1 and Table 6-2.
Table 6-1. Supply Regulator Setting: 5-V System
REGISTER
ADDRESS
(hex)
OPTION BITS SETTING IN REGULATOR CONTROL REGISTER (1)
COMMENTS
B7 B6 B5 B4 B3 B2 B1 B0
Automatic Mode (default)
0B 1 x x x x x 0 0 Automatic regulator setting 400-mV difference
Manual Mode
0B 0 x x x x 1 1 1 VDD_RF = 5 V, VDD_A = 3.4 V, VDD_X = 3.4 V
0B 0 x x x x 1 1 0 VDD_RF = 4.9 V, VDD_A = 3.4 V, VDD_X = 3.4 V
0B 0 x x x x 1 0 1 VDD_RF = 4.8 V, VDD_A = 3.4 V, VDD_X = 3.4 V
0B 0 x x x x 1 0 0 VDD_RF = 4.7 V, VDD_A = 3.4 V, VDD_X = 3.4 V
0B 0 x x x x 0 1 1 VDD_RF = 4.6 V, VDD_A = 3.4 V, VDD_X = 3.4 V
0B 0 x x x x 0 1 0 VDD_RF = 4.5 V, VDD_A = 3.4 V, VDD_X = 3.4 V
0B 0 x x x x 0 0 1 VDD_RF = 4.4 V, VDD_A = 3.4 V, VDD_X = 3.4 V
0B 0 x x x x 0 0 0 VDD_RF = 4.3 V, VDD_A = 3.4 V, VDD_X = 3.4 V
(1) x = Don't care
Table 6-2. Supply Regulator Setting: 3-V System
REGISTER
ADDRESS
(hex)
OPTION BITS SETTING IN REGULATOR CONTROL REGISTER (1)
COMMENTS
B7 B6 B5 B4 B3 B2 B1 B0
Automatic Mode (default)
0B 1 x x x x x 0 0 Automatic regulator setting 400-mV difference
Manual Mode
0B 0 x x x x 1 1 1 VDD_RF = 3.4 V, VDD_A = 3.4 V, VDD_X = 3.4 V
0B 0 x x x x 1 1 0 VDD_RF = 3.3 V, VDD_A = 3.3 V, VDD_X = 3.3 V
0B 0 x x x x 1 0 1 VDD_RF = 3.2 V, VDD_A = 3.2 V, VDD_X = 3.2 V
0B 0 x x x x 1 0 0 VDD_RF = 3.1 V, VDD_A = 3.1 V, VDD_X = 3.1 V
0B 0 x x x x 0 1 1 VDD_RF = 3.0 V, VDD_A = 3.0 V, VDD_X = 3.0 V
0B 0 x x x x 0 1 0 VDD_RF = 2.9 V, VDD_A = 2.9 V, VDD_X = 2.9 V
0B 0 x x x x 0 0 1 VDD_RF = 2.8 V, VDD_A = 2.8 V, VDD_X = 2.8 V
0B 0 x x x x 0 0 0 VDD_RF = 2.7 V, VDD_A = 2.7 V, VDD_X = 2.7 V
The regulator configuration function adjusts the regulator outputs by default to 400 mV below VIN level, but
not higher than 5 V for VDD_RF, 3.4 V for VDD_A and VDD_X. This ensures the highest possible supply
voltage for the RF output stage while maintaining an adequate PSRR (power supply rejection ratio).
16
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
(1) X = Don't care
6.3.3 Power Modes
The chip has several power states, which are controlled by two input pins (EN and EN2) and several bits
in the chip status control register (0x00) (see Table 6-3 and Table 6-4).
Table 6-3. 3.3-V Operation Power Modes(1)
MODE EN2 EN
CHIP
STATUS
CONTROL
REGISTER
(0x00)
REGULATOR
CONTROL
REGISTER
(0x0B)
TRANSMITTER RECEIVER SYS_CLK
(13.56 MHz) SYS_CLK
(60 kHz) VDD_X
TYPICAL
CURRENT
(mA)
TYPICAL
POWER
OUT (dBm)
Power down 0 0 XX XX OFF OFF OFF OFF OFF <0.001 -
Sleep mode 1 0 XX XX OFF OFF OFF ON ON 0.120 -
Standby mode at +3.3 VDC X 1 80 00 OFF OFF ON X ON 2 -
Mode 1 at +3.3 VDC X 1 00 00 OFF OFF ON X ON 3 -
Mode 2 at +3.3 VDC X 1 02 00 OFF ON ON X ON 9 -
Mode 3 (half power) at
+3.3 VDC X 1 30 07 ON ON ON X ON 53 14.5
Mode 4 (full power) at
+3.3 VDC X 1 20 07 ON ON ON X ON 67 17
(1) X = Don't care
Table 6-4. 5-V Operation Power Modes(1)
MODE EN2 EN
CHIP
STATUS
CONTROL
REGISTER
(0x00)
REGULATOR
CONTROL
REGISTER
(0x0B)
TRANSMITTER RECEIVER SYS_CLK
(13.56 MHz) SYS_CLK
(60 kHz) VDD_X
TYPICAL
CURRENT
(mA)
TYPICAL
POWER
OUT (dBm)
Power down 0 0 XX XX OFF OFF OFF OFF OFF <0.001 -
Sleep mode 1 0 XX XX OFF OFF OFF ON ON 0.120 -
Standby mode at +5 VDC X 1 81 07 OFF OFF ON X ON 3 -
Mode 1 at +5 VDC X 1 01 07 OFF OFF ON X ON 5 -
Mode 2 at +5 VDC X 1 03 07 OFF ON ON X ON 10.5 -
Mode 3 (half power) at
+5 VDC X 1 31 07 ON ON ON X ON 70 20
Mode 4 (full power) at
+5 VDC X 1 21 07 ON ON ON X ON 130 23
Table 6-3 and Table 6-4 show the configuration for the different power modes when using a 3.3-V or 5-V
system supply, respectively. The main reader enable signal is pin EN. When EN is set high, all of the
reader regulators are enabled, the 13.56-MHz oscillator is running and the SYS_CLK (output clock for
external microcontroller) is also available.
The input pin EN2 has two functions:
A direct connection from EN2 to VIN to ensure the availability of the regulated supply VDD_X and an
auxiliary clock signal (60 kHz, SYS_CLK) for an external MCU. This mode (EN = 0, EN2 = 1) is
intended for systems in which the MCU is also being supplied by the reader supply regulator (VDD_X)
and the MCU clock is supplied by the SYS_CLK output of the reader. This allows the MCU supply and
clock to be available during sleep mode.
EN2 enables the start-up of the reader system from complete power down (EN = 0, EN2 = 0). In this
case the EN input is being controlled by the MCU (or other system device) that is without supply
voltage during complete power down (thus unable to control the EN input). A rising edge applied to the
EN2 input (which has an approximately 1-V threshold level) starts the reader supply system and 13.56-
MHz oscillator (identical to condition EN = 1).
When user MCU is controlling EN and EN2, a delay of 1 ms between EN and EN2 must be used. If the
MCU controls only EN, TI recommends connecting EN2 to either VIN or GND, depending on the
application MCU requirements for VDD_X and SYS_CLK.
17
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
Figure 6-3. Nominal Start-up Sequence Using SPI With SS (MCU Controls EN2)
Figure 6-4. Nominal Start-up Sequence Using Parallel (MCU Controls EN2)
This start-up mode lasts until all of the regulators have settled and the 13.56-MHz oscillator has stabilized.
If the EN input is set high (EN = 1) by the MCU (or other system device), the reader stays active. If the EN
input is not set high (EN = 0) within 100 µs after the SYS_CLK output is switched from auxiliary clock (60
kHz) to high-frequency clock (derived from the crystal oscillator), the reader system returns to complete
Power-Down Mode 1. This option can be used to wake-up the reader system from complete Power Down
(PD Mode 1) by using a pushbutton switch or by sending a single pulse.
After the reader EN line is high, the other power modes are selected by control bits within the chip status
control register (0x00). The power mode options and states are listed in Table 6-3.
When EN is set high (or on rising edge of EN2 and then confirmed by EN = 1) the supply regulators are
activated and the 13.56-MHz oscillator is started. When the supplies are settled and the oscillator
frequency is stable, the SYS_CLK output is switched from the auxiliary frequency of 60 kHz to the 13.56-
MHz frequency derived from the crystal oscillator. At this point, the reader is ready to communicate and
perform the required tasks. When this occurs, osc_ok (B6) of the RSSI Level and Oscillator Status register
is set. The MCU can then program the Chip Status Control register 0x00 and select the operation mode
by programming the additional registers.
Standby Mode (bit 7 = 1 of register 0x00), the reader is capable of recovering to full operation in
100 µs.
Mode 1 (active mode with RF output disabled, bit 5 = 0 and bit 1 = 0 of register 0x00) is a low power
mode which allows the reader to recover to full operation within 25 µs.
Mode 2 (active mode with only the RF receiver active, bit 1 = 1 of register 0x00) can be used to
measure the external RF field (as described in RSSI measurements paragraph) if reader-to-reader
anticollision is implemented.
Modes 3 and 4 (active modes with the entire RF section active, bit 5 = 1 of register 0x00) are the
normal modes used for normal transmit and receive operations.
18
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
6.4 Receiver Analog Section
6.4.1 Main and Auxiliary Receivers
The TRF7964A has two receiver inputs: RX_IN1 (pin 8) and RX_IN2 (pin 9). Each of the input is
connected to an external capacitive voltage divider to ensure that the modulated signal from the tag is
available on at least one of the two inputs. This architecture eliminates any possible communication holes
that may occur from the tag to the reader.
The two RX inputs (RX_IN1 and RX_IN2) are multiplexed into two receivers - the main receiver and the
auxiliary receiver. Only the main receiver is used for reception, the auxiliary receiver is used for signal
quality monitoring. Receiver input multiplexing is controlled by bit B3 in the Chip Status Control register
(address 0x00).
After start-up, RX_IN1 is multiplexed to the main receiver which is composed of an RF envelope detection,
first gain and band-pass filtering stage, second gain and filtering stage with AGC. Only the main receiver
is connected to the digitizing stage which output is connected to the digital processing block. The main
receiver also has an RSSI measuring stage, which measures the strength of the demodulated signal
(subcarrier signal).
The primary function of the auxiliary receiver is to monitor the RX signal quality by measuring the RSSI of
the demodulated subcarrier signal (internal RSSI). After start-up, RX_IN2 is multiplexed to the auxiliary
receiver. The auxiliary receiver has an RF envelope detection stage, first gain and filtering with AGC stage
and finally the auxiliary RSSI block.
The default MUX setting is RX_IN1 connected to the main receiver and RX_IN2 connected to the auxiliary
receiver. To determine the signal quality, the response from the tag is detected by the "main" (pin RX_IN1)
and "auxiliary" (pin RX_IN2) RSSI. Both values measured and stored in the RSSI Levels and Oscillator
Status register (address 0x0F). The MCU can read the RSSI values from the TRF7964A RSSI register
and make the decision if swapping the input- signals is preferable or not. Setting B3 in Chip Status Control
register (address 0x00) to 1 connects RX_IN1 (pin 8) to the auxiliary received and RX_IN2 (pin 9) to the
main receiver.
The main and auxiliary receiver input stages are RF envelope detectors. The RF amplitude at RX_IN1 and
RX_IN2 should be approximately 3 VPP for a VINsupply level greater than 3.3 V. If the VIN level is lower,
the RF input peak-to-peak voltage level should not exceed the VINlevel.
6.4.2 Receiver Gain and Filter Stages
The first gain and filtering stage has a nominal gain of 15 dB with an adjustable band-pass filter. The
band-pass filter has programmable 3-dB corner frequencies between 110 kHz to 450 kHz for the high-
pass filter and 570 kHz to 1500 kHz for the low-pass filter. After the band-pass filter, there is another gain-
and-filtering stage with a nominal gain of 8 dB and with frequency characteristics identical to the first band-
pass stage.
The internal filters are configured automatically depending on the selected ISO communication standard in
the ISO Control register (address 0x01). If required, additional fine tuning can be done by writing directly
to the RX Special Setting registers (address 0x0A).
Table 6-5 shows the various settings for the receiver analog section. Setting B4, B5, B6, and B7 to 0
results in a band-pass characteristic of 240 kHz to 1.4 MHz, which is appropriate for ISO/IEC 14443 B
106 kbps, ISO/IEC 14443 A and B data rates of 212 kbps and 424 kbps, and FeliCa 424 kbps.
19
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
Table 6-5. RX Special Setting Register (0x0A)
Function: Sets the gains and filters directly
Default: 0x40 at POR = H or EN = L, and at each write to the ISO Control register (0x01). When bits B7, B6, B5 and B4 are all zero, the
filters are set for ISO/IEC 14443 B (240 kHz to 1.4 MHz).
Bit Name Function Description
B7 C212 Band-pass 110 kHz to 570 kHz Appropriate for 212-kHz subcarrier system (FeliCa)
B6 C424 Band-pass 200 kHz to 900 kHz Appropriate for 424-kHz subcarrier used in ISO/IEC 15693
B5 M848 Band-pass 450 kHz to 1.5 MHz Appropriate for Manchester-coded 848-kHz subcarrier used in
ISO/IEC 14443 A and B
B4 hbt Band-pass 100 kHz to 1.5 MHz
Gain reduced for 18 dB Appropriate for highest bit rate (848 kbps) used in high-bit-rate
ISO/IEC 14443
B3 gd1 00 = Gain reduction 0 dB
01 = Gain reduction for 5 dB
10 = Gain reduction for 10 dB
11 = Gain reduction for 15 dB Sets the RX gain reduction and reduces sensitivity
B2 gd2
B1 Reserved
B0 Reserved
6.5 Receiver Digital Section
The output of the TRF7964A analog receiver block is a digitized subcarrier signal and is the input to the
digital receiver block, which consists of two sections that partly overlap. The digitized subcarrier signal is a
digital representation of the modulation signal on the RF envelope. The two sections of the digital receiver
block are the protocol bit decoder section and the framing logic section.
The protocol bit decoder section converts the subcarrier coded signal into a serial bit stream and a data
clock. The decoder logic is designed for maximum error tolerance. This tolerance lets the decoder section
successfully decode even partly corrupted subcarrier signals that would otherwise be lost due to noise or
interference.
The framing logic section formats the serial bit stream data from the protocol bit decoder stage into data
bytes. During the formatting process, special signals such as the start of frame (SOF), end of frame
(EOF), start of communication, and end of communication are automatically removed. The parity bits and
CRC bytes are also checked and removed. The end result is "clean or raw" data that is sent to the 127-
byte FIFO register where it can be read by the external microcontroller system. Providing the data this
way, in conjunction with the timing register settings of the TRF7964A, means that the firmware developer
does not need to know the finer details of the ISO protocols to create a very robust application, especially
in low-cost platforms in which code space is at a premium and high performance is still required.
The start of the receive operation (successfully received SOF) sets the IRQ flags in the IRQ Status
register (0x0C). The end of the receive operation is signaled to the external system MCU by setting pin 13
(IRQ) to high. When data is received in the FIFO, an interrupt is sent to the MCU to signal that there is
data to be read from the FIFO. The FIFO Status register (0x1C) should be used to provide the number of
bytes that should be clocked out during the actual FIFO read. Additionally, an interrupt is sent to the MCU
when the received data occupies 75% of the FIFO capacity to signal that the data should be removed
from the FIFO. By default, that interrupt is triggered once the received data packet is longer than 124
bytes. This setting can be modified in the Adjustable FIFO IRQ Levels register (0x14).
Any error in the data format, parity, or CRC is detected and notified to the external system by setting pin
13 (IRQ) to high. The source condition of the interrupt is available in the IRQ Status register (0x0C).
Section 6.14.3.3.1 describes the bit coding description of this register.
The framing section also supports bit-collision detection as specified in ISO/IEC 14443 A and
ISO/IEC 15693. When a bit collision is detected, an interrupt request is sent and a flag is set in the IRQ
Status register (0x0C). For ISO/IEC 14443 A specifically, the position of the bit collision is written in two
registers: partly in the Collision Position register (0x0E) and partly in the Collision Position and Interrupt
Mask register (0x0D) (bits B6 and B7).
20
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
This collision position is presented as sequential bit number, where the count starts immediately after the
start bit. This means a collision in the first bit of a UID would give the value 00 0001 0000 in these
registers when their contents are combined after being read (the count starts with 0 and the first 16 bits
are the command code and the number of valid bits [NVB] byte).
The receive section also contains two timers.
The RX wait time timer is controlled by the value in the RX Wait Time register (0x08). This timer defines
the time interval after the end of the transmit operation during which the receive decoders are not active
(held in reset state). This prevents false detections resulting from transients following the transmit
operation. The value of the RX Wait Time register (0x08) defines the time in increments of 9.44 µs. This
register is preset at every write to the ISO Control register (0x01) according to the minimum tag response
time defined by each standard.
The RX no response timer is controlled by the RX No Response Wait Time register (0x07). This timer
measures the time from the start of the slot in the anticollision sequence until the start of tag response. If
there is no tag response in the defined time, an interrupt request is sent and a flag is set in the IRQ Status
register (0x0C). This enables the external controller to be relieved of the task of detecting empty slots. The
wait time is stored in the register in increments of 37.76 µs. This register is also preset automatically for
every new protocol selection.
The main register controlling the digital part of the receiver is the ISO Control register (0x01). By writing to
this register, the user selects the protocol to be used. With each new write in this register, all related
registers are preset to their defaults for the protocol, so no further adjustments in other registers are
needed for proper operation. Table 6-6 describes the bit fields of the ISO Control register (0x01).
NOTE
If changes to other registers are needed to fine-tune the system, those changes must be
made after setting the ISO Control register (0x01).
21
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
Table 6-6. Coding of the ISO Control Register
BIT SIGNAL NAME FUNCTION COMMENTS
B7 rx_crc_n Receiving without CRC 1 = No RX CRC
0 = RX CRC
B6 dir_mode Direct mode type 0 = Output is subcarrier data
1 = Output is bit stream and clock from decoder selected by ISO bits
B5 rfid RFID mode 0 = RFID reader mode
1 = Reserved (should be set to 0)
B4 iso_4 RFID See Table 6-7 for B0:B4 settings based on ISO protocol used by application.
B3 iso_3 RFID See Table 6-7 for B0:B4 settings based on ISO protocol used by application.
B2 iso_2 RFID See Table 6-7 for B0:B4 settings based on ISO protocol used by application.
B1 iso_1 RFID See Table 6-7 for B0:B4 settings based on ISO protocol used by application.
B0 iso_0 RFID See Table 6-7 for B0:B4 settings based on ISO protocol used by application.
22
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
Table 6-7. Coding of the ISO Control Register For RFID Mode (B5 = 0)
Iso_4 Iso_3 Iso_2 Iso_1 Iso_0 PROTOCOL REMARKS
0 0 0 0 0 ISO/IEC 15693 low bit rate, one subcarrier, 1 out of 4
0 0 0 0 1 ISO/IEC 15693 low bit rate, one subcarrier, 1 out of 256
0 0 0 1 0 ISO/IEC 15693 high bit rate, one subcarrier, 1 out of 4 Default for RFID IC
0 0 0 1 1 ISO/IEC 15693 high bit rate, one subcarrier, 1 out of 256
0 0 1 0 0 ISO/IEC 15693 low bit rate, double subcarrier, 1 out of 4
0 0 1 0 1 ISO/IEC 15693 low bit rate, double subcarrier, 1 out of 256
0 0 1 1 0 ISO/IEC 15693 high bit rate, double subcarrier, 1 out of 4
0 0 1 1 1 ISO/IEC 15693 high bit rate, double subcarrier, 1 out of 256
0 1 0 0 0 ISO/IEC 14443 A, bit rate 106 kbps
0 1 0 0 1 ISO/IEC 14443 A high bit rate 212 kbps RX bit rate when TX rate
different from RX rate (see
register 0x03)
0 1 0 1 0 ISO/IEC 14443 A high bit rate 424 kbps
0 1 0 1 1 ISO/IEC 14443 A high bit rate 848 kbps
0 1 1 0 0 ISO/IEC 14443 B, bit rate 106 kbps
0 1 1 0 1 ISO/IEC 14443 B high bit rate 212 kbps RX bit rate when TX rate
different from RX rate (see
register 0x03)
0 1 1 1 0 ISO/IEC 14443 B high bit rate 424 kbps
0 1 1 1 1 ISO/IEC 14443 B high bit rate 848 kbps
1 0 0 1 1 Reserved
1 0 1 0 0 Reserved
1 1 0 1 0 FeliCa 212 kbps
1 1 0 1 1 FeliCa 424 kbps
0
1
2
3
4
5
6
7
0 0.25 0.5 0.75 1 1.25 1.5 1.75 2 2.25 2.5 2.75 3 3.25 3.5 3.75 4 4.25
Input RF Carrier Level (V )
PP
RSSI Levels and Oscillator Status Register Value (0x0F)
23
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
6.5.1 Received Signal Strength Indicator (RSSI)
The TRF7964A incorporates in total three independent RSSI building blocks: Internal Main RSSI, Internal
Auxiliary RSSI, and External RSSI. The internal RSSI blocks measure the amplitude of the subcarrier
signal, and the external RSSI block measures the amplitude of the RF carrier signal at the receiver input.
6.5.1.1 Internal RSSI Main and Auxiliary Receivers
Each receiver path has its own RSSI block to measure the envelope of the demodulated RF signal
(subcarrier). Internal Main RSSI and Internal Auxiliary RSSI are identical however connected to different
RF input pins. The Internal RSSI is intended for diagnostic purposes to set the correct RX path conditions.
The internal RSSI values can be used to adjust the RX gain settings or determine which RX path (main or
auxiliary) provides the greater amplitude and, hence, to determine if the MUX may need to be
reprogrammed to swap the RX input signal. The measuring system latches the peak value, so the RSSI
level can be read after the end of each receive packet. The RSSI register values are reset with every
transmission (TX) by the reader. This ensures an updated RSSI measurement for each new tag response.
The Internal RSSI has 7 steps (3 bit) with a typical increment of approximately 4 dB. The operating range
is between 600 mVPP and 4.2 VPP with a typical step size of approximately 600 mV. Both Internal Main
and Internal Auxiliary RSSI values are stored in the RSSI Levels and Oscillator Status register (0x0F). The
nominal relationship between the input RF peak level and the RSSI value is shown in Figure 6-5.
Figure 6-5. Digital Internal RSSI (Main and Auxiliary) Value vs RF Input Level in VPP (V)
This RSSI measurement is done during the communication to the Tag; this means the TX must be on. Bit
1 in the Chip Status Control register (0x00) defines if Internal RSSI or the External RSSI value is stored in
the RSSI Levels and Oscillator Status register (0x0F). Direct command 0x18 is used to trigger an Internal
RSSI measurement.
6.5.1.2 External RSSI
The external RSSI is mainly used to check for any external 13.56-MHz signals at the receiver RX_IN1
input. The external RSSI measurement should be used before turning on the transmitter to prevent RF
field collisions. This is especially important for active mode, when both devices emit their own RF field.
The level of the RF signal received at the antenna is measured and stored in the RSSI Levels and
Oscillator Status register (0x0F). Figure 6-6 shows the relationship between the voltage at the RX_IN1
input and the 3-bit code.
0
1
2
3
4
5
6
7
0 25 50 75 100 125 150 175 200 225 250 275 300 325
RF Input Voltage Level at RF_IN1 (mV )
PP
RSSI Levels and Oscillator Status Register Value (0x0F)
24
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
Figure 6-6. Digital External RSSI Value vs RF Input Level in VPP (mV)
The relation between the 3-bit code and the external RF field strength (A/m) sensed by the antenna must
be determined by calculation or by experiments for each antenna design. The antenna Q-factor and
connection to the RF input influence the result. Direct command 0x19 is used to trigger an external RSSI
measurement.
For clarity, to check the internal or external RSSI value independent of any other operation, the user must:
1. Set transmitter to desired state (on or off) using Bit 5 of Chip Status Control register (0x00) and enable
receiver using Bit 1.
2. Check internal or external RSSI using direct commands 0x18 or 0x19, respectively. This action places
the RSSI value in the RSSI register.
3. Delay at least 50 µs.
4. Read the RSSI register using direct command 0x0F; values range from 0x40 to 0x7F.
5. Repeat steps 1 to 4 as needed. The register is reset when it is read.
6.6 Oscillator Section
The 13.56-MHz or 27.12-MHz crystal (or oscillator) is controlled by the Chip Status Control register (0x00)
and the EN and EN2 terminals. The oscillator generates the RF frequency for the RF output stage as well
as the clock source for the digital section. The buffered clock signal is available at pin 27 (SYS_CLK) for
any other external circuits. B4 and B5 inside the Modulation and SYS_CLK register (0x09) can be used to
divide the external SYS_CLK signal at pin 27 by 1, 2, or 4.
Typical start-up time from complete power down is in the range of 3.5 ms.
During Power Down Mode 2 (EN = 0, EN2 = 1) the frequency of SYS_CLK is switched to 60 kHz (typical).
The crystal needs to be connected between pin 30 and pin 31. The external shunt capacitors values for C1
and C2must be calculated based on the specified load capacitance of the crystal being used. The external
shunt capacitors are calculated as two identical capacitors in series plus the stray capacitance of the
TRF7964A and parasitic PCB capacitance in parallel to the crystal.
The parasitic capacitance (CS, stray and parasitic PCB capacitance) can be estimated at 4 to 5 pF
(typical).
As an example, using a crystal with a required load capacitance (CL) of 18 pF, the calculation is shown in
Equation 1.
Crystal
C1C2
CS
Pin 31Pin 30
25
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
C1= C2= 2 × (CL CS) = 2 × (18 pF 4.5 pF) = 27 pF (1)
A 27-pF capacitor must be placed on pins 30 and 31 to ensure proper crystal oscillator operation.
Figure 6-7. Crystal Block Diagram
Any crystal used with TRF7964A should meet the minimum characteristics in Table 6-8.
Table 6-8. Minimum Crystal Recommendations
PARAMETER SPECIFICATION
Frequency 13.56 MHz or 27.12 MHz
Mode of operation Fundamental
Type of resonance Parallel
Frequency tolerance ±20 ppm
Aging < 5 ppm/year
Operation temperature range –40°C to 85°C
As an alternative, an external clock oscillator source can be connected to pin 31 to provide the system
clock; pin 30 can be left open.
6.7 Transmitter Analog Section
The 13.56-MHz oscillator generates the RF signal for the PA stage. The power amplifier consists of a
driver with selectable output resistance of nominal 4 Ωor 8 Ω. The transmit power level is set by bit B4 in
the Chip Status Control register (0x00). The transmit power levels are selectable between 100 mW (half
power) or 200 mW (full power) when configured for 5-V automatic operation. The transmit power levels
are selectable between 33 mW (half power) or 70 mW (full power) when configured for 3-V automatic
operation.
The ASK modulation depth is controlled by bits B0, B1, and B2 in the Modulator and SYS_CLK Control
register (0x09). The ASK modulation depth range can be adjusted between 7% to 30% or 100% (OOK).
External control of the transmit modulation depth is possible by setting the ISO Control register (0x01) to
direct mode. While operating the TRF7964A in direct mode, the transmit modulation is made possible by
selecting the modulation type ASK or OOK at pin 12. External control of the modulation type is made
possible only if enabled by setting B6 in the Modulator and SYS_CLK Control register (0x09) to 1.
In normal operation mode, the length of the modulation pulse is defined by the protocol selected in the
ISO Control register (0x01). With a high-Q antenna, the modulation pulse is typically prolonged, and the
tag detects a longer pulse than intended. For such cases, the modulation pulse length needs to be
corrected by using the TX Pulse Length Control register (0x06).
If the register contains all zeros, then the pulse length is governed by the protocol selection. If the register
contains a value other than 0x00, the pulse length is equal to the value of the register multiplied by
73.7 ns; therefore, the pulse length can be adjusted between 73.7 ns and 18.8 µs in 73.7-ns increments.
26
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
6.8 Transmitter Digital Section
The digital part of the transmitter is a mirror of the receiver. The settings controlled the ISO Control
register (0x01) are applied to the transmitter just like the receiver. In the TRF7964A default mode the
TRF7964A automatically adds these special signals: start of communication, end of communication, SOF,
EOF, parity bits, and CRC bytes.
The data is then coded to modulation pulse levels and sent to the RF output stage modulation control unit.
Similar to working with the receiver, this means that the external system MCU must only load the FIFO
with data, and all the microcoding is done automatically, again saving the firmware developer code space
and time. Additionally, all of the registers used for transmit parameter control are automatically preset to
optimum values when a new selection is entered into the ISO Control register (0x01).
NOTE
The FIFO must be reset before starting any transmission with direct command 0x0F.
There are two ways to start the transmit operation:
Send the transmit command and the number of bytes to be transmitted first, and then start to send the
data to the FIFO. The transmission starts when first data byte is written into the FIFO.
Load the number of bytes to be sent into registers 0x1D and 0x1E and load the data to be sent into the
FIFO (address 0x1F), followed by sending a transmit command (see Direct Commands section). The
transmission then starts when the transmit command is received.
NOTE
If the data length is longer than the FIFO, the TRF7964A notifies the external system MCU
when most of the data from the FIFO has been transmitted by sending an interrupt request
with a flag in the IRQ register to indicate a FIFO low or high status. The external system
should respond by loading the next data packet into the FIFO.
At the end of a transmit operation, the external system MCU is notified by interrupt request (IRQ) with a
flag in IRQ register (0x0C) indicating TX is complete (example value = 0x80).
The TX Length registers also support incomplete byte transmission. The high two nibbles in register 0x1D
and the nibble composed of bits B4 through B7 in register 0x1E store the number of complete bytes to be
transmitted. Bit B0 in register 0x1E is a flag indicating that there are also additional bits to be transmitted
that do not form a complete byte. The number of bits is stored in bits B1 through B3 of the same register
(0x1E).
Some protocols have options, and there are two sublevel configuration registers to select the TX protocol
options.
ISO/IEC 14443 B TX Options register (0x02). This register controls the SOF and EOF selection and
EGT selection for the ISO/IEC 14443 B protocol.
ISO/IEC 14443 A High Bit Rate Options and Parity register (0x03). This register enables the use of
different bit rates for RX and TX operations in the ISO/IEC 14443 high bit rate protocol and also
selects the parity method in the ISO/IEC 14443 A high bit rate protocol.
The digital section also has a timer. The timer can be used to start the transmit operation at a specified
time in accordance with a selected event.
27
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
(1) FIFO is not accessible in SPI without SS mode. See the TRF7970A Silicon Errata for detailed information.
(2) MOSI = master out, slave in
(3) MISO = master in, slave out
(4) I/O_5 pin is used only for information when data is put out of the chip (for example, reading 1 byte from the chip). It is necessary first to
write in the address of the register (8 clocks) and then to generate another 8 clocks for reading out the data. The I/O_5 pin goes high
during the second 8 clocks. But for normal SPI operations, I/O_5 pin is not used.
(5) Slave select pin is active low
6.9 Transmitter External Power Amplifier and Subcarrier Detector
The TRF7964A can be used in conjunction with an external TX power amplifier or external subcarrier
detector for the receiver path. In this case, certain registers must be programmed as shown here:
Bit B6 of the Regulator and I/O Control register (0x0B) must be set to 1. This setting has two functions:
first, to provide a modulated signal for the transmitter if needed, and second, to configure the
TRF7964A receiver inputs for an external demodulated subcarrier input.
Bit B3 of the Modulation and SYS_CLK Control register (0x09) must be set to 1 (see
Section 6.14.3.2.8). This function configures the ASK/OOK pin for either a digital or analog output
(B3 = 0 enables a digital output, B3 = 1 enables an analog output). The design of an external power
amplifier requires detailed RF knowledge. There are also readily designed and certified high-power HF
reader modules on the market.
6.10 TRF7964A IC Communication Interface
6.10.1 General Introduction
The communication interface to the reader can be configured in two ways: with a eight line parallel
interface (D0:D7) plus DATA_CLK, or with a 4-wire Serial Peripheral Interface (SPI). The SPI interface
uses traditional Master Out/Slave In (MOSI), Master In/Slave Out (MISO), Slave Select, and DATA_CLK
lines.
These communication modes are mutually exclusive; that is, only one mode can be used at a time in the
application.
When the SPI interface is selected, the unused I/O_2, I/O_1, and I/O_0 pins must be hard-wired as shown
in Table 6-9. At power up, the TRF7964A samples the status of these three pins and then enters one of
the possible SPI modes.
The TRF7964A always behaves as the slave device, and the microcontroller (MCU) behaves as the
master device. The MCU initiates all communications with the TRF7964A, and the TRF7964A makes use
of the Interrupt Request (IRQ) pin in both parallel and SPI modes to prompt the MCU for servicing
attention.
Table 6-9. Pin Assignment in Parallel and Serial Interface Connection or Direct Mode
PIN PARALLEL PARALLEL (DIRECT MODE) SPI WITH SS SPI WITHOUT SS(1)
DATA_ CLK DATA_CLK DATA_CLK DATA_CLK from master DATA_CLK from master
I/O_7 A/D[7] Not used MOSI(2) = data in (reader in) MOSI(2) = data in (reader in)
I/O_6 A/D[6] Direct mode, data out (subcarrier
or bit stream) MISO(3) = data out (MCU out) MISO(3) = data out (MCU out)
I/O_5(4) A/D[5] Direct mode, strobe bit clock
out See (4). See (4).
I/O_4 A/D[4] Not used SS slave select(5) Not used
I/O_3 A/D[3] Not used Not used Not used
I/O_2 A/D[2] Not used At VDD At VDD
I/O_1 A/D[1] Not used At VDD At VSS
I/O_0 A/D[0] Not used At VSS At VSS
IRQ IRQ interrupt IRQ interrupt IRQ interrupt IRQ interrupt
28
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
Communication is initialized by a start condition, which is expected to be followed by an
Address/Command word (Adr/Cmd). The Adr/Cmd word is 8 bits long, and Table 6-10 shows its format.
Table 6-10. Address and Command Word Bit Distribution
BIT DESCRIPTION BIT FUNCTION ADDRESS COMMAND
B7 Command control bit 0 = Address
1 = Command 0 1
B6 Read/Write 0 = Write
1 = Read R/W 0
B5 Continuous address mode 1 = Continuous mode R/W 0
B4 Address/Command bit 4 Adr 4 Cmd 4
B3 Address/Command bit 3 Adr 3 Cmd 3
B2 Address/Command bit 2 Adr 2 Cmd 2
B1 Address/Command bit 1 Adr 1 Cmd 1
B0 Address/Command bit 0 Adr 0 Cmd 0
The MSB (bit 7) determines if the word is to be used as a command or as an address. The last two
columns of Table 6-10 show the function of the separate bits if either address or command is written. Data
is expected once the address word is sent. In continuous-address mode (Cont. mode = 1), the first data
that follows the address is written (or read) to (from) the given address. For each additional data, the
address is incremented by one. Continuous mode can be used to write to a block of control registers in a
single stream without changing the address; for example, setup of the predefined standard control
registers from the MCU nonvolatile memory to the reader. In noncontinuous address mode (simple
addressed mode), only one data word is expected after the address.
Address Mode is used to write or read the configuration registers or the FIFO. When writing more than 12
bytes to the FIFO, the Continuous Address Mode should be set to 1.
Command Mode is used to enter a command resulting in reader action (for example, initialize
transmission, enable reader, and turn reader on or off).
The following sections give examples of the expected communications between an MCU and the
TRF7964A.
29
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
6.10.1.1 Continuous Address Mode
Figure 6-8 summarizes the continuous address mode communication. Figure 6-8 and Figure 6-9 show the
signals between the MCU and the TRF7964A.
Table 6-11. Continuous Address Mode
Start Adr x Data(x) Data(x+1) Data(x+2) Data(x+3) Data(x+4) ... Data(x+n) StopCont
Figure 6-8. Continuous Address Register Write Example Starting With Register 0x00 Using SPI With SS
Figure 6-9. Continuous Address Register Read Example Starting With Register 0x00 Using SPI With SS
30
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
6.10.1.2 Noncontinuous Address Mode (Single Address Mode)
Table 6-12 summarizes the noncontinuous address (single address) mode communication. Figure 6-10
and Figure 6-11 show the signals between the MCU and the TRF7964A.
Table 6-12. Noncontinuous Address Mode (Single Address Mode)
Start Adr x Data(x) Adr y Data(y) ... Adr z Data(z) StopSgl
Figure 6-10. Single Address Register Write Example of Register 0x00 Using SPI With SS
Figure 6-11. Single Address Register Read Example of Register 0x00 Using SPI With SS
31
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
6.10.1.3 Direct Command Mode
Table 6-13 summarizes the direct command mode communication. Figure 6-12 shows the signals
between the MCU and the TRF7964A.
Table 6-13. Direct Command Mode
Start Cmd x (Optional data or command) Stop
Figure 6-12. Direct Command Example of Sending 0x0F (Reset) Using SPI With SS
Section 6.13 describes the other direct command codes from the MCU to the TRF7964A IC.
6.10.1.4 FIFO Operation
The FIFO is a 127-byte register at address 0x1F with byte storage locations 0 to 126. FIFO data is loaded
in a cyclical manner and can be cleared by a reset command (0x0F) (see Figure 6-12 showing this direct
command).
Associated with the FIFO are two counters and three FIFO status flags. The first counter is a 7-bit FIFO
byte counter (bits B0 to B6 in register 0x1C) that tracks the number of bytes loaded into the FIFO. If the
number of bytes in the FIFO is n, the register value is n (number of bytes in FIFO register). For example, if
8 bytes are in the FIFO, the FIFO counter (Register 0x1C) has the hexadecimal value of 0x08 (binary
value of 00001000).
A second counter (12 bits wide) indicates the number of bytes being transmitted (registers 0x1D and
0x1E) in a data frame. An extension to the transmission-byte counter is a 4-bit broken-byte counter also
provided in register 0x1E (bits B0 to B3). Together these counters make up the TX length value that
determines when the reader generates the EOF byte.
During transmission, the FIFO is checked for an almost-empty condition, and during reception for an
almost-full condition. The maximum number of bytes that can be loaded into the FIFO in a single
sequence is 127 bytes.
NOTE
The number of bytes in a frame, transmitted or received, can be greater than 127 bytes.
CLK
I/O_[7]
I/O_[6:0]
a1 [7] d1 [7] a2 [7] d2 [7] aN [7] dN [7]
a1 [6:0] d1 [6:0] a2 [6:0] d2 [6:0] aN [6:0] dN [6:0]
50 ns
Start
Condition
StopSmpl
Condition
32
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
During transmission, the MCU loads the TRF7964A FIFO (or during reception the MCU removes data
from the FIFO), and the FIFO counter counts the number of bytes being loaded into the FIFO. Meanwhile,
the byte counter keeps track of the number of bytes being transmitted. An interrupt request is generated if
the number of bytes in the FIFO triggers the watermark levels, which are configured in the Adjustable
FIFO IRQ Levels register (0x14). The default setting is for the interrupt to be triggered when receiving
124 bytes during RX or having 4 bytes remaining during TX. These watermark levels are used so that
MCU can send new data or read the data as necessary. The MCU must also validate the number of data
bytes to be sent, so as to not surpass the value defined in the TX Length Byte registers (0x1D and 0x1E).
The MCU also signals the transmit logic when the last byte of data is sent or was removed from the FIFO
during reception.
Figure 6-13 shows an example of checking the FIFO Status register using SPI with SS.
Figure 6-13. Example of Checking the FIFO Status Register Using SPI With SS
6.10.2 Parallel Interface Mode
In parallel mode, the start condition is generated on the rising edge of the I/O_7 pin while the CLK is high.
This is used to reset the interface logic. Figure 6-14,Figure 6-15, and Figure 6-16 show the sequence of
the data, with an 8-bit address word first, followed by data.
Communication is ended by:
The StopSmpl condition, where a falling edge on the I/O_7 pin is expected while CLK is high.
The StopCont condition, where the I/O_7 pin must have a successive rising and falling edge while CLK
is low to reset the parallel interface and be ready for the new communication sequence.
The StopSmpl condition is also used to terminate the direct mode.
Figure 6-14. Parallel Interface Communication With Simple Stop Condition (StopSmpl)
CLK
I/O_[7]
I/O_[6:0]
a0 [7] d0 [7] d1 [7] d2 [7] d3 [7] dN [7]
a0 [6:0] d0 [6:0] d1 [6:0] d2 [6:0] d3 [6:0] dN [6:0]xx xx
50 ns
Start
Condition
StopCont
Continuous Mode
33
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
Figure 6-15. Parallel Interface Communication With Continuous Stop Condition (StopCont)
Figure 6-16. Example of Parallel Interface Communication With Continuous Stop Condition
6.10.3 Reception of Air Interface Data
At the start of a receive operation (when SOF is successfully detected), B6 is set in the IRQ Status
register. An RX complete interrupt request is sent to the MCU at the end of the receive operation if the
receive data string is shorter than or equal to the number of bytes configured in the Adjustable FIFO IRQ
Levels register (0x14). An IRQ_FIFO interrupt request is sent to the MCU during the receive operation if
the data string is greater than the level set in the Adjustable FIFO IRQ Levels register (0x14). After
receiving an IRQ_FIFO or RX complete interrupt, the MCU must read the FIFO Status register (0x1C) to
determine the number of bytes to be read from the FIFO. Next, the MCU must read the data in the FIFO.
It is optional but recommended to read the FIFO Status register (0x1C) after reading FIFO data to
determine if the receive is complete. In the case of an IRQ_FIFO, the MCU should expect either another
IRQ_FIFO or RX complete interrupt. This is repeated until an RX complete interrupt is generated. The
MCU receives the interrupt request, then checks to determine the reason for the interrupt by reading the
IRQ Status register (0x0C), after which the MCU reads the data from the FIFO.
If the reader detects a receive error, the corresponding error flag is set (framing error, CRC error) in the
IRQ Status register, indicating to the MCU that reception was not completed correctly.
34
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
6.10.4 Data Transmission From MCU to TRF7964A
Before beginning data transmission, the FIFO should always be cleared with a reset command (0x0F).
Data transmission is initiated with a selected command (see Section 6.13). The MCU then commands the
reader to do a continuous write command (0x3D) starting from register 0x1D. Data written into register
0x1D is the TX Length Byte 1 (upper and middle nibbles), while the following byte in register 0x1E is the
TX Length Byte 2 (lower nibble and broken byte length) (see Table 6-47 and Table 6-48) . Note that the
TX byte length determines when the reader sends the end of frame (EOF) byte. After the TX length bytes
are written, FIFO data is loaded in register 0x1F with byte storage locations 0 to 127. Data transmission
begins automatically after the first byte is written into the FIFO. The loading of TX length bytes and the
FIFO can be done with a continuous-write command, as the addresses are sequential.
At the start of transmission, the flag B7 (IRQ_TX) is set in the IRQ Status register, and at the end of the
transmit operation, an interrupt is sent to inform the MCU that the task is complete.
6.10.5 Serial Interface Communication (SPI)
When an SPI interface is used, I/O pins I/O_2, I/O_1, and I/O_0 must be hard wired according to Table 6-
9. On power up, the TRF7964A looks for the status of these pins and then enters into the corresponding
mode.
The serial communications work in the same manner as the parallel communications with respect to the
FIFO, except for the following condition. On receiving an IRQ from the reader, the MCU reads the
TRF7964A IRQ Status register to determine how to service the reader. After this, the MCU must to do a
dummy read to clear the reader's IRQ status register. The dummy read is required in SPI mode because
the reader's IRQ status register needs an additional clock cycle to clear the register. This is not required in
parallel mode because the additional clock cycle is included in the Stop condition. When first establishing
communications with the TRF7964A, the SOFT_INIT (0x03) and IDLE (0x00) commands should be sent
first from the MCU (see Table 6-14).
The procedure for a dummy read is as follows (see Figure 6-17 and Figure 6-18):
1. Start the dummy read:
(a) When using slave select (SS): set SS bit low.
(b) When not using SS: start condition is when Data Clock is high (see Table 6-9).
2. Send address word to IRQ status register (0x0C) with read and continuous address mode bits set to 1
(see Table 6-9).
3. Read 1 byte (8 bits) from IRQ status register (0x0C).
4. Dummy-read 1 byte from register 0x0D (collision position and interrupt mask).
5. Stop the dummy read:
(a) When using slave select (SS): set SS bit high.
(b) When not using SS: stop condition when Data Clock is high.
Write Address
Byte (0x6C)
No Data Transitions (All High or Low)
Don’t Care Ignore
B7 B6 B5 B4 B3 B2 B1 B0
Slave
Select
MISO
MOSI
DATA_CLK
No Data Transitions (All High or Low)
B7 B6 B5 B4 B3 B2 B1 B0
Read Data in
IRQ Status Register Dummy Read
35
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
Figure 6-17. Procedure for Dummy Read
Figure 6-18. Example of Dummy Read Using SPI With SS
6.10.5.1 Serial Interface Mode With Slave Select (SS)
The serial interface is in reset while the Slave Select signal is high. Serial data in (MOSI) changes on the
rising edge, and is validated in the reader on the falling edge, as shown in Figure 6-19. Communication is
terminated when the Slave Select signal goes high.
All words must be 8 bits long with the MSB transmitted first.
Slave
Select
MISO
MOSI
DATA_CLK
Write
Address Byte
Read Data
Byte 1
Read Data
Byte n
Don’t Care
No Data Transitions (All High or Low) No Data Transitions (All High or Low)
B7 B6 B5 B4 B3 B2 B1 B0
B7 B6 B5 B4 B3 B2 B1 B0 B7 B6 B5 B4 B3 B2 B1 B0
b0MISO
MOSI
DATA_CLK
Write
MOSI Transitions on Data Clock
Rising Edge
MOSI Valid on Data Clock Falling Edge
tSTE,LEAD
b7
tLO/HI tLO/HI
b6…b1 b0
tSU,SI tHD,SI
1/fUCxCLK tSTE,DIS
b6...b1
tVALID,SO
tSTE,LAG
tHD,SO
Don’t Care
Read
Data Transition is on Data Clock
Rising Edge
MISO Valid on Data Clock Falling Edge
tSU,SO
b7
No Data Transitions
(All High or Low)
Slave Select
36
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
Figure 6-19. SPI With Slave Select Timing Diagram
The read command is sent out on the MOSI pin, MSB first, in the first eight clock cycles. MOSI data
changes on the rising edge, and is validated in the reader on the falling edge, as shown in Figure 6-19.
During the write cycle, the serial data out (MISO) is not valid. After the last read command bit (B0) is
validated at the eighth falling edge of SCLK, valid data can be read on the MISO pin at the falling edge of
SCLK. It takes eight clock edges to read out the full byte (MSB first). See Section 5.4 for electrical
specifications related to Figure 6-19.
Figure 6-20 and Figure 6-21 show the continuous read operation.
Figure 6-20. Continuous Read Operation Using SPI With Slave Select
37
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
Figure 6-21. Continuous Read of Registers 0x00 to 0x05 Using SPI With SS
Figure 6-22 shows an example of performing a single slot inventory command. Reader registers (in this example)
are configured for 5 VDC in and default operation.
Figure 6-22. Inventory Command Sent From MCU to TRF7964A
The TRF7964A takes these bytes from the MCU and then send out Request Flags, Inventory Command,
and Mask over the air to the ISO/IEC 15693 transponder. After these three bytes have been transmitted,
an interrupt occurs to indicate back to the reader that the transmission has been completed. In the
example in Figure 6-23, this IRQ occurs approximately 1.6 ms after the SS line goes high after the
Inventory command is sent out.
38
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
Figure 6-23. IRQ After Inventory Command
The IRQ status register read (0x6C) yields 0x80, which indicates that TX is indeed complete. This is
followed by a dummy clock. Then, if a tag is in the field and no error is detected by the reader, a second
interrupt is expected and occurs (in this example) approximately 4 ms after first IRQ is read and cleared.
In the continuation of the example (see Figure 6-24), the IRQ Status Register is read using method
previously recommended, followed by a single read of the FIFO Status register, which indicates that there
are 10 bytes to be read out.
Figure 6-24. Read IRQ Status Register After Inventory Command
This is then followed by a continuous read of the FIFO (see Figure 6-25). The first byte is (and should be)
0x00 for no error. The next byte is the DSFID (usually shipped by manufacturer as 0x00), then the UID,
shown here up to the next most significant byte, the MFG code [shown as 0x07 (TI silicon)].
39
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
Figure 6-25. Continuous Read of FIFO After Inventory Command
TI recommends resetting the FIFO after receiving data. Additionally, the RSSI value of the tag can be read
out at this point. In the example in Figure 6-26, the transponder is very close to the antenna, so value of
0x7F is recovered.
Figure 6-26. Reset FIFO and Read RSSI
Analog Front End (AFE)
14443A
ISO Encoders and Decoders
14443B 15693 FeliCa
Packetization and Framing
Microcontroller
Direct Mode 0:
Raw RF Subcarrier
Data Stream
Direct Mode 1:
Raw Digital ISO Coded
Data Without
Protocol Frame
ISO Mode:
Full ISO Framing
and Error Checking
(Typical Mode)
40
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
6.10.6 Direct Mode
Direct mode allows the user to configure the reader in one of two ways. Direct mode 0 (bit 6 = 0, as
defined in ISO Control register) allows the user to use only the front-end functions of the reader,
bypassing the protocol implementation in the reader. For transmit functions, the user has direct access to
the transmit modulator through the MOD pin (pin 14). On the receive side, the user has direct access to
the subcarrier signal (digitized RF envelope signal) on I/O_6 (pin 23).
Direct mode 1 (bit 6 = 1, as defined in ISO Control register) uses the subcarrier signal decoder of the
selected protocol (as defined in ISO Control register). This means that the receive output is not the
subcarrier signal but the decoded serial bit stream and bit clock signals. The serial data is available on
I/O_6 (pin 23) and the bit clock is available on I/O_5 (pin 22). The transmit side is identical; the user has
direct control over the RF modulation through the MOD input. This mode is provided so that the user can
implement a protocol that has the same bit coding as one of the protocols implemented in the reader, but
needs a different framing format.
To select direct mode, the user must first choose which direct mode to enter by writing B6 in the ISO
Control register. This bit determines if the receive output is the direct subcarrier signal (B6 = 0) or the
serial data of the selected decoder. If B6 = 1, then the user must also define which protocol should be
used for bit decoding by writing the appropriate setting in the ISO Control register.
The reader actually enters the direct mode when B6 (direct) is set to 1 in the chip status control register.
Direct mode starts immediately. The write command should not be terminated with a stop condition (see
communication protocol), because the stop condition terminates the direct mode and clears B6. This is
necessary as the direct mode uses one or two I/O pins (I/O_6, I/O_5). Normal parallel communication is
not possible in direct mode. Sending a stop condition terminates direct mode.
NOTE
An additional direct mode known as special direct mode can be used to communicate with
certain tags not compliant with ISO standards. For full details on how to use this feature, see
Using Special Direct Mode With the TRF7970A.
Figure 6-27 shows the different configurations available in direct mode.
In mode 0, the reader is used as an AFE only, and protocol handling is bypassed.
In mode 1, framing is not done, but SOF and EOF are present. This allows for a user-selectable
framing level based on an existing ISO standard.
In mode 2, data is ISO-standard formatted. SOF, EOF, and error checking are removed, so the
microprocessor receives only bytes of raw data through a 127-byte FIFO.
Figure 6-27. User-Configurable Modes
41
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
The steps to enter direct mode are listed below, using SPI with SS communication method only as one
example, as direct modes are also possible with parallel and SPI without SS. The must enter direct mode
0 to accommodate card type communications that are not compliant with ISO standards. Direct mode can
be entered at any time, so if a card type started with ISO standard communications, then deviated from
the standard after being identified and selected, the ability to go into direct mode 0 is very useful.
Step 1: Configure Pins I/O_0 to I/O_2 for SPI with SS
Step 2: Set Pin 12 of the TRF7964A (ASK/OOK pin) to 0 for ASK or 1 for OOK
Step 3: Program the TRF7964A registers
The following registers must be explicitly set before going into the direct mode.
1. ISO Control register (0x01) to the appropriate standard
0x02 for ISO/IEC 15693 High Data Rate
0x08 for ISO/IEC 14443 A (106 kbps)
0x1A for FeliCa 212 kbps
0x1B for FeliCa 424 kbps
2. Modulator and SYS_CLK register (0x09) to the appropriate clock speed and modulation
0x21 for 6.78 MHz Clock and OOK (100%) modulation
0x20 for 6.78 MHz Clock and ASK 10% modulation
0x22 for 6.78 MHz Clock and ASK 7% modulation
0x23 for 6.78 MHz Clock and ASK 8.5% modulation
0x24 for 6.78 MHz Clock and ASK 13% modulation
0x25 for 6.78 MHz Clock and ASK 16% modulation
(See register 0x09 definition for all other possible values)
Example register setting for ISO/IEC 14443 A at 106 kbps:
ISO Control register (0x01) to 0x08
RX No Response Wait Time register (0x07) to 0x0E
RX Wait Time register (0x08) to 0x07
Modulator control register (0x09) to 0x21 (or any custom modulation)
RX Special Settings register (0x0A) to 0x20
42
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
Step 4: Entering Direct Mode 0
The following registers must be programmed to enter direct mode 0:
1. Set bit B6 of the Modulator and SYS_CLK Control register (0x09) to 1.
2. Set bit B6 of the ISO Control (Register 01) to 0 for direct mode 0 (default its 0)
3. Set bit B6 of the Chip Status Control register (0x00) to 1 to enter direct mode
4. Send extra eight clock cycles (see Figure 6-28, this step is TRF7964A specific)
NOTE
It is important that the last write is not terminated with a stop condition. For SPI, this
means that Slave Select (I/O_4) stays low.
Sending a Stop condition terminates the direct mode and clears bit B6 in the Chip Status
Control register (0x00).
NOTE
Access to Registers, FIFO, and IRQ is not available during direct mode 0.
The reader enters the direct mode 0 when bit 6 of the Chip Status Control register (0x00) is set to a 1 and
stays in direct mode 0 until a stop condition is sent from the microcontroller.
NOTE
The write command should not be terminated with a stop condition (for example, in SPI
mode this is done by bringing the Slave Select line high after the register write), because the
stop condition terminates the direct mode and clears bit 6 of the Chip Status Control register
(0x00), making it a 0.
Figure 6-28. Entering Direct Mode 0
TRF7964A Microcontroller
Drive the MOD pin
according to the data coding
specified by the standard
Decode the subcarrier
information according
to the standard
MOD
(Pin 14)
I/O_6
(Pin 23)
43
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
Step 5: Transmit Data Using Direct Mode
The application now has direct control over the RF modulation through the MOD input (see Figure 6-29).
Figure 6-29. Direct Control Signals
The microcontroller is responsible for generating data according to the coding specified by the particular
standard. The microcontroller must generate SOF, EOF, Data, and CRC. In direct mode, the FIFO is not
used and no IRQs are generated. See the applicable ISO standard to understand bit and frame
definitions. Figure 6-30 shows an example of what the developer sees when using DM0 in an actual
application. This figure clearly shows the relationship between the MOD pin being controlled by the MCU
and the resulting modulated 13.56-MHz carrier signal.
Figure 6-30. TX Sequence Out in DM0
Step 6: Receive Data Using Direct Mode
After the TX operation is complete, the tag responds to the request and the subcarrier data is available on
pin I/O_6. The microcontroller needs to decode the subcarrier signal according to the standard. This
includes decoding the SOF, data bits, CRC, and EOF. The CRC then needs to be checked to verify data
integrity. The receive data bytes must be buffered locally.
As an example of the receive data bits and framing level according to the ISO/IEC 14443 A standard is
shown in Figure 6-31 (taken from ISO/IEC 14443 specification and TRF7964A air interface).
?
?
?
128/fc = 9.435 µs = t (106-kbps data rate)
64/fc = 4.719 µs = t time
32/fc = 2.359 µs = t time
b
x
1
t = 9.44
bµs t = 4.72
xµs t = 2.48
1µs
Sequence Y = Carrier for 9.44 µs Sequence Z = Pause for 2
Carrier for Remainder of 9.44
to 3 µs,
µs
44
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
Figure 6-31. Receive Data Bits and Framing Level
45
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
Figure 6-32 shows an example of what the developer should expect on the I/O_6 line during the RX
process while in direct mode 0.
Figure 6-32. RX Sequence on I/O_6 in DM0 (Analog Capture)
Step 7: Terminating Direct Mode 0
After the EOF is received, data transmission is over, and direct mode 0 can be terminated by sending a
Stop Condition (in the case of SPI, make the Slave Select go high). The TRF7964A is returned to default
state.
6.11 TRF7964A Initialization
To properly initialize the TRF7964A, perform these steps:
1. Raise the EN, EN2, and SS lines at the correct intervals after power up (for timing diagrams, see
Figure 6-3 and Figure 6-4).
2. Issue a Software Initialization direct command (0x03), followed by an Idle direct command (0x00) to
soft reset the TRF7964A.
NOTE
Table 6-16 lists the initial register settings for the TRF7964A after the Software Initialization
command.
3. Delay 1 ms to allow the TRF7964A to fully process the soft reset.
4. Issue a Reset FIFO direct command (0x0F).
5. Write the Modulator and SYS_CLK Control register (0x09) with the appropriate application-specific
setting for the crystal and system clock settings.
6. (Optional) Write the Regulator and I/O Control register (0x0B) with the appropriate application-specific
setting.
6.12 Special Direct Mode for Improved MIFARE™ Compatibility
46
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
See Using Special Direct Mode With the TRF7970A.
6.13 Direct Commands from MCU to Reader
6.13.1 Command Codes
Table 6-14 summarizes the command codes.
Table 6-14. Address and Command Word Bit Distribution
COMMAND
CODE COMMAND COMMENTS
0x00 Idle
0x03 Software initialization Same as Power on Reset
0x0F Reset FIFO
0x10 Transmission without CRC
0x11 Transmission with CRC
0x12 Delayed transmission without CRC
0x13 Delayed transmission with CRC
0x14 End of frame and transmit next time slot Used for ISO/IEC 15693 only
0x16 Block receiver
0x17 Enable receiver
0x18 Test internal RF (RSSI at RX input with TX off)
0x19 Test external RF (RSSI at RX input with TX on)
The command code values from Table 6-14 are substituted in Table 6-15, bits 0 through 4. Also, the most-
significant bit (MSB) in Table 6-15 must be set to 1. (Table 6-15 is same as Table 6-10, shown here again
for easy reference).
Table 6-15. Address and Command Word Bit Distribution
BIT DESCRIPTION BIT FUNCTION ADDRESS COMMAND
B7 Command control bit 0 = Address
1 = Command 0 1
B6 Read/Write 0 = Write
1 = Read R/W 0
B5 Continuous address mode 1 = Continuous mode R/W 0
B4 Address/Command bit 4 Adr 4 Cmd 4
B3 Address/Command bit 3 Adr 3 Cmd 3
B2 Address/Command bit 2 Adr 2 Cmd 2
B1 Address/Command bit 1 Adr 1 Cmd 1
B0 Address/Command bit 0 Adr 0 Cmd 0
The MSB determines if the word is to be used as a command or address. The last two columns of
Table 6-15 show the function of each bit, depending on whether address or command is written.
Command mode is used to enter a command resulting in reader action (initialize transmission, enable
reader, and turn reader on or off).
6.13.1.1 Idle (0x00)
This command issues dummy clock cycles. In parallel mode, one cycle is issued. In SPI mode, eight
cycles are issued. This command should be sent after a Software Initialization command to allow the
command to finish operation.
47
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
6.13.1.2 Software Initialization (0x03)
This command starts a power-on reset. After sending this command, the register values change as shown
in Table 6-16.
(1) Differs from default at POR
Table 6-16. Register Values After Sending Software
Initialization (0x03)
ADDRESS REGISTER VALUE
0x00 Chip status control 0x01
0x01 ISO control 0x21(1)
0x02 ISO/IEC 14443 B TX options 0x00
0x03 ISO/IEC 14443 A high bit rate options 0x00
0x04 TX timer high byte control 0xC1(1)
0x05 TX timer low byte control 0xC1(1)
0x06 TX pulse length control 0x00
0x07 RX no response wait time 0x0E
0x08 RX wait time 0x07(1)
0x09 Modulator and SYS_CLK control 0x91
0x0A RX special setting 0x10(1)
0x0B Regulator and I/O control 0x87
0x0C IRQ status 0x00
0x0D Collision position and interrupt mask 0x3E
0x0E Collision position 0x00
0x0F RSSI levels and oscillator status 0x40
0x10 Special function 0x00
0x11 Special function 0x00
0x12 RAM 0x00
0x13 RAM 0x00
0x14 Adjustable FIFO IRQ levels 0x00
0x1A Test 0x00
0x1B Test 0x00
0x1C FIFO status 0x00
6.13.1.3 Reset FIFO (0x0F)
The reset command clears the FIFO contents and FIFO Status register (0x1C). It also clears the register
storing the collision error location (0x0E).
6.13.1.4 Transmission With CRC (0x11)
The transmission command must be sent first, followed by transmission length bytes, and FIFO data. The
reader starts transmitting after the first byte is loaded into the FIFO. The CRC byte is included in the
transmitted sequence.
6.13.1.5 Transmission Without CRC (0x10)
Same as Section 6.13.1.4 with CRC excluded.
6.13.1.6 Delayed Transmission With CRC (0x13)
The transmission command must be sent first, followed by the transmission length bytes, and FIFO data.
The reader transmission is triggered by the TX timer.
48
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
6.13.1.7 Delayed Transmission Without CRC (0x12)
Same as Section 6.13.1.6 with CRC excluded.
6.13.1.8 Transmit Next Time Slot (0x14)
When this command is received, the reader transmits the next slot command. The next slot sign is defined
by the protocol selection. This is used by the ISO/IEC 15693 protocol.
6.13.1.9 Block Receiver (0x16)
The block receiver command puts the digital part of receiver (bit decoder and framer) in reset mode. This
is useful in an extremely noisy environment, where the noise level could otherwise cause a constant
switching of the subcarrier input of the digital part of the receiver. The receiver (if not in reset) would try to
catch a SOF signal, and if the noise pattern matched the SOF pattern, an interrupt would be generated,
falsely signaling the start of an RX operation. A constant flow of interrupt requests can be a problem for
the external system (MCU), so the external system can stop this by putting the receive decoders in reset
mode. The reset mode can be terminated in two ways. The external system can send the enable receiver
command. The reset mode is also automatically terminated at the end of a TX operation. The receiver can
stay in reset after end of TX if the RX wait time register (0x08) is set. In this case, the receiver is enabled
at the end of the wait time following the transmit operation.
6.13.1.10 Enable Receiver (0x17)
This command clears the reset mode in the digital part of the receiver if the reset mode was entered by
the block receiver command.
6.13.1.11 Test Internal RF (RSSI at RX Input With TX ON) (0x18)
The level of the RF carrier at RF_IN1 and RF_IN2 inputs is measured. Operating range between 300 mVP
and 2.1 VP(step size is 300 mV). The two values are displayed in the RSSI Levels and Oscillator Status
register (0x0F). The command is intended for diagnostic purposes to set correct RF_IN levels. Optimum
RFIN input level is approximately 1.6 VPor code 5 to 6. The nominal relationship between the RF peak
level and RSSI code is shown in Table 6-17 and in Section 6.5.1.1.
NOTE
If the command is executed immediately after power-up and before any communication with
a tag is performed, the command must be preceded by Enable RX command. The Check RF
commands require full operation, so the receiver must be activated by Enable RX or by a
normal Tag communication for the Check RF command to work properly.
Table 6-17. Test Internal RF Peak Level to RSSI Codes
RF_IN1 [mVPP]300 600 900 1200 1500 1800 2100
Decimal Code 1234567
Binary Code 001 010 011 001 101 011 111
6.13.1.12 Test External RF (RSSI at RX Input with TX OFF) (0x19)
This command can be used in active mode when the RF receiver is switched on but RF output is switched
off. This means bit B1 = 1 in Chip Status Control Register. The level of RF signal received on the antenna
is measured and displayed in the RSSI Levels and Oscillator Status register (0x0F). The relation between
the 3 bit code and the external RF field strength [A/m] must be determinate by calculation or by
experiments for each antenna type as the antenna Q and connection to the RF input influence the result.
The nominal relation between the RF peak to peak voltage in the RF_IN1 input and RSSI code is shown
in Table 6-18 and in Section 6.5.1.2.
49
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
NOTE
If the command is executed immediately after power-up and before any communication with
a tag is performed, the command must be preceded by an Enable RX command. The Check
RF commands require full operation, so the receiver must be activated by Enable RX or by a
normal Tag communication for the Check RF command to work properly.
Table 6-18. Test External RF Peak Level to RSSI Codes
RF_IN1 [mVPP]40 60 80 100 140 180 300
Decimal Code 1234567
Binary Code 001 010 011 001 101 011 111
6.14 Register Description
6.14.1 Register Preset
After power up and the EN pin low-to-high transition, the reader is in the default mode. The default
configuration is ISO/IEC 15693, single subcarrier, high data rate, 1-out-of-4 operation. The low-level option
registers (0x02 to 0x0B) are automatically set to adapt the circuitry optimally to the appropriate protocol
parameters. When entering another protocol (by writing to the ISO Control register 0x01), the low-level
option registers (0x02 to 0x0B) are automatically configured to the new protocol parameters. After
selecting the protocol, it is possible to change some low-level register contents if needed. However,
changing to another protocol and then back, reloads the default settings, and so then the custom settings
must be reloaded.
The Clo0 and Clo1 register (0x09) bits, which define the microcontroller frequency available on the
SYS_CLK pin, are the only 2 bits in the configuration registers that are not cleared during protocol
selection.
50
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
6.14.2 Register Overview
Table 6-19 lists the registers.
Table 6-19. Register Definitions
ADDRESS REGISTER READ/WRITE SECTION
Main Control Registers
0x00 Chip status control R/W Section 6.14.3.1.1
0x01 ISO Control R/W Section 6.14.3.1.2
Protocol Subsetting Registers
0x02 ISO/IEC 14443 B TX options R/W Section 6.14.3.2.1
0x03 ISO/IEC 14443 A high bit rate options R/W Section 6.14.3.2.2
0x04 TX timer high byte control R/W Section 6.14.3.2.3
0x05 TX timer low byte control R/W Section 6.14.3.2.4
0x06 TX pulse length control R/W Section 6.14.3.2.5
0x07 RX no response wait time R/W Section 6.14.3.2.6
0x08 RX wait time R/W Section 6.14.3.2.7
0x09 Modulator and SYS_CLK control R/W Section 6.14.3.2.8
0x0A RX special setting R/W Section 6.14.3.2.9
0x0B Regulator and I/O control R/W Section 6.14.3.2.10
0x10 Special function register (preset 0x00) R/W Section 6.14.3.3.4
0x11 Special function register (preset 0x00) R/W Section 6.14.3.3.5
0x14 Adjustable FIFO IRQ levels R/W Section 6.14.3.3.6
Status Registers
0x0C IRQ status R Section 6.14.3.3.1
0x0D Collision position and interrupt mask register R/W Section 6.14.3.3.2
0x0E Collision position R Section 6.14.3.3.2
0x0F RSSI levels and oscillator status R Section 6.14.3.3.3
Test Registers
0x1A Test (preset 0x00) R/W Section 6.14.3.4.1
0x1B Test (preset 0x00) R/W Section 6.14.3.4.2
FIFO Registers
0x1C FIFO status R Section 6.14.3.5.1
0x1D TX length byte 1 R/W Section 6.14.3.5.2
0x1E TX length byte 2 R/W Section 6.14.3.5.2
0x1F FIFO I/O register R/W N/A
51
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
6.14.3 Detailed Register Description
6.14.3.1 Main Configuration Registers
6.14.3.1.1 Chip Status Control Register (0x00)
Table 6-20 describes the Chip Status Control register.
Table 6-20. Chip Status Control Register (0x00)
Function: Control of Power mode, RF on or off, Active or Passive mode, Direct mode
Default: 0x01, preset at EN = L or POR = H
Bit Name Function Description
B7 stby 1 = Standby mode Standby mode keeps all supply regulators and the 13.56-MHz SYS_CLK
oscillator running. (Typical start-up time to full operation is 100 µs.)
0 = Active mode Active mode (default)
B6 direct 1 = Direct mode 0 or 1 Provides user direct access to AFE (direct mode 0) or allows user to add
custom framing (direct mode 1). Bit 6 of the ISO Control register must be set by
user before entering direct mode 0 or 1.
0 = Direct l 2 (default) Uses SPI or parallel communication with automatic framing and ISO decoders
B5 rf_on 1 = RF output active Transmitter on, receivers on
0 = RF output not active Transmitter off
B4 rf_pwr 1 = Half output power TX_OUT (pin 5) = 8-Ωoutput impedance P = 100 mW (20 dBm) at 5 V,
P = 33 mW (+15 dBm) at 3.3 V
0 = Full output power TX_OUT (pin 5) = 4-Ωoutput impedance P = 200 mW (+23 dBm) at 5 V,
P = 70 mW (+18 dBm) at 3.3 V
B3 pm_on 1 = Selects aux RX input RX_IN2 input is used
0 = Selects main RX input RX_IN1 input is used
B2 Reserved
B1 rec_on 1 = Receiver activated for
external field measurement Forced enabling of receiver and TX oscillator. Used for external field
measurement.
0 = Automatic enable Allows enable of the receiver by bit 5 of this register (0x00)
B0 vrs5_3 1 = 5-V operation
0 = 3-V operation Selects the VIN voltage range
(1) Only applicable to ISO/IEC 14443 A and ISO/IEC 15693
6.14.3.1.2 ISO Control Register (0x01)
Table 6-21 describes the ISO Control register.
Table 6-21. ISO Control Register (0x01)
Function: Controls the selection of ISO standard protocol, direct mode and receive CRC
Default: 0x02 (ISO/IEC 15693 high bit rate, one subcarrier, 1 out of 4); it is preset at EN = L or POR = H
Bit Name Function Description
B7 rx_crc_n CRC Receive selection 0 = RX CRC (CRC is present in the response)
1 = no RX CRC (CRC is not present in the response)(1)
B6 dir_mode Direct mode type selection 0 = Direct Mode 0
1 = Direct mode 1
B5 rfid RFID / Reserved 0 = RFID mode
1 = Reserved (should be set to 0)
B4 iso_4 RFID RFID: See Table 6-22 for B0:B4 settings based on ISO protocol in application
B3 iso_3 RFID RFID: See Table 6-22 for B0:B4 settings based on ISO protocol in application
B2 iso_2 RFID RFID: See Table 6-22 for B0:B4 settings based on ISO protocol in application
B1 iso_1 RFID RFID: See Table 6-22 for B0:B4 settings based on ISO protocol in application
52
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
Table 6-21. ISO Control Register (0x01) (continued)
B0 iso_0 RFID RFID: See Table 6-22 for B0:B4 settings based on ISO protocol in application
(1) For ISO/IEC 14443 A or B, when bit rate of TX is different from RX, settings can be done in register 0x02 or 0x03.
Table 6-22. ISO Control Register ISO_x Settings, RFID Mode
ISO_4 ISO_3 ISO_2 ISO_1 ISO_0 PROTOCOL REMARKS
0 0 0 0 0 ISO/IEC 15693 low bit rate, 6.62 kbps, one subcarrier, 1 out of 4
0 0 0 0 1 ISO/IEC 15693 low bit rate, 6.62 kbps, one subcarrier, 1 out of 256
0 0 0 1 0 ISO/IEC 15693 high bit rate, 26.48 kbps, one subcarrier, 1 out of 4 Default for reader
0 0 0 1 1 ISO/IEC 15693 high bit rate, 26.48 kbps, one subcarrier, 1 out of 256
0 0 1 0 0 ISO/IEC 15693 low bit rate, 6.67 kbps, double subcarrier, 1 out of 4
00101ISO/IEC 15693 low bit rate, 6.67 kbps, double subcarrier, 1 out of
256
0 0 1 1 0 ISO/IEC 15693 high bit rate, 26.69 kbps, double subcarrier, 1 out of 4
00111ISO/IEC 15693 high bit rate, 26.69 kbps, double subcarrier,
1 out of 256
0 1 0 0 0 ISO/IEC 14443 A RX bit rate, 106 kbps RX bit rate (1)
0 1 0 0 1 ISO/IEC 14443 A RX high bit rate, 212 kbps
0 1 0 1 0 ISO/IEC 14443 A RX high bit rate, 424 kbps
0 1 0 1 1 ISO/IEC 14443 A RX high bit rate, 848 kbps
0 1 1 0 0 ISO/IEC 14443 B RX bit rate, 106 kbps RX bit rate (1)
0 1 1 0 1 ISO/IEC 14443 B RX high bit rate, 212 kbps
0 1 1 1 0 ISO/IEC 14443 B RX high bit rate, 424 kbps
0 1 1 1 1 ISO/IEC 14443 B RX high bit rate, 848 kbps
1 0 0 1 1 Reserved
1 0 1 0 0 Reserved
1 1 0 1 0 FeliCa 212 kbps
1 1 0 1 1 FeliCa 424 kbps
53
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
6.14.3.2 Control Registers Sublevel Configuration Registers
6.14.3.2.1 ISO/IEC 14443 TX Options Register (0x02)
Table 6-23 describes the ISO/IEC 14443 TX Options register.
Table 6-23. ISO/IEC 14443 TX Options Register (0x02)
Function: Selects the ISO subsets for ISO/IEC 14443 TX
Default: 0x00 at POR = H or EN = L
Bit Name Function Description
B7 egt2 TX EGT time select MSB Three bit code defines the number of etu (0-7) which separate two characters.
ISO/IEC 14443 B TX only.
B6 egt1 TX EGT time select
B5 egt0 TX EGT time select LSB
B4 eof_l0 1 = EOF0 length 11 etu
0 = EOF0 length 10 etu
ISO/IEC 14443 B TX only
B3 sof_l1 1 = SOF1 length 03 etu
0 = SOF1 length 02 etu
B2 sof _l0 1 = SOF0 length 11 etu
0 = SOF0 length 10 etu
B1 l_egt 1 = EGT after each byte
0 = EGT after last byte is
omitted
B0 Reserved
6.14.3.2.2 ISO/IEC 14443 High-Bit-Rate and Parity Options Register (0x03)
Table 6-24 describes the ISO/IEC 14443 High-Bit-Rate and Parity Options register.
Table 6-24. ISO/IEC 14443 High-Bit-Rate and Parity Options Register (0x03)
Function: Selects the ISO subsets for ISO/IEC 14443 TX
Default: 0x00 at POR = H or EN = L, and at each write to ISO Control register
Bit Name Function Description
B7 dif_tx_br TX bit rate different from RX
bit rate enable Valid for ISO/IEC 14443 A or B high bit rate
B6 tx_br1 TX bit rate tx_br1 = 0, tx_br = 0 106 kbps
tx_br1 = 0, tx_br = 1 212 kbps
tx_br1 = 1, tx_br = 0 424 kbps
tx_br1 = 1, tx_br = 1 848 kbps
B5 tx_br0
B4 parity-2tx 1 = parity odd except last
byte which is even for TX For ISO/IEC 14443 A high bit rate, coding and decoding
B3 parity-2rx 1 = parity odd except last
byte which is even for RX
B2 Unused
B1 Unused
B0 Unused
54
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
6.14.3.2.3 TX Timer High Byte Control Register (0x04)
Table 6-25 describes the TX Timer High Byte Control register.
Table 6-25. TX Timer High Byte Control Register (0x04)
Function: For Timings
Default: 0xC2 at POR = H or EN = L, and at each write to ISO Control register
Bit Name Function Description
B7 tm_st1 Timer Start Condition tm_st1 = 0, tm_st0 = 0 beginning of TX SOF
tm_st1 = 0, tm_st0 = 1 end of TX SOF
tm_st1 = 1, tm_st0 = 0 beginning of RX SOF
tm_st1 = 1, tm_st0 = 1 end of RX SOF
B6 tm_st0 Timer Start Condition
B5 tm_lengthD Timer Length MSB
B4 tm_lengthC Timer Length
B3 tm_lengthB Timer Length
B2 tm_lengthA Timer Length
B1 tm_length9 Timer Length
B0 tm_length8 Timer Length LSB
6.14.3.2.4 TX Timer Low Byte Control Register (0x05)
Table 6-26 describes the TX Timer Low Byte Control register.
Table 6-26. TX Timer Low Byte Control Register (0x05)
Function: For Timings
Default: 0x00 at POR = H or EN = L, and at each write to ISO Control register
Bit Name Function Description
B7 tm_length7 Timer Length MSB
Defines the time when delayed transmission is started.
RX wait range is 590 ns to 9.76 ms (1 to 16383)
Step size is 590 ns
All bits low = timer disabled (0x00)
Preset 0x00 for all other protocols
B6 tm_length6 Timer Length
B5 tm_length5 Timer Length
B4 tm_length4 Timer Length
B3 tm_length3 Timer Length
B2 tm_length2 Timer Length
B1 tm_length1 Timer Length
B0 tm_length0 Timer Length LSB
55
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
6.14.3.2.5 TX Pulse Length Control Register (0x06)
The length of the modulation pulse is defined by the protocol selected in the ISO Control register 0x01.
With a high Q antenna, the modulation pulse is typically prolonged, and the tag detects a longer pulse
than intended. For such cases, the modulation pulse length can be corrected by using the TX Pulse
Length Control register (0x06). If the register contains all zeros, then the pulse length is governed by the
protocol selection. If the register contains a value other than 0x00, the pulse length is equal to the value of
the register in 73.7-ns increments. This means the range of adjustment can be 73.7 ns to 18.8 µs.
Table 6-27 describes the TX Pulse Length Control register.
Table 6-27. TX Pulse Length Control Register (0x06)
Function: Controls the length of TX pulse
Default: 0x00 at POR = H or EN = L and at each write to ISO Control register.
Bit Name Function Description
B7 Pul_p2 Pulse length MSB The pulse range is 73.7 ns to 18.8 µs (1….255), step size 73.7 ns.
All bits low (00): pulse length control is disabled.
The following default timings are preset by the ISO Control register (0x01):
9.44 µs ISO/IEC 15693 (TI Tag-It HF-I)
11 µs Reserved
2.36 µs ISO/IEC 14443 A at 106 kbps
1.4 µs ISO/IEC 14443 A at 212 kbps
737 ns ISO/IEC 14443 A at 424 kbps
442 ns ISO/IEC 14443 A at 848 kbps; pulse length control disabled
B6 Pul_p1
B5 Pul_p0
B4 Pul_c4
B3 Pul_c3
B2 Pul_c2
B1 Pul_c1
B0 Pul_c0 Pulse length LSB
6.14.3.2.6 RX No Response Wait Time Register (0x07)
The RX No Response timer is controlled by the RX NO Response Wait Time Register 0x07. This timer
measures the time from the start of slot in the anticollision sequence until the start of tag response. If there
is no tag response in the defined time, an interrupt request is sent and a flag is set in IRQ status control
register 0x0C. This enables the external controller to be relieved of the task of detecting empty slots. The
wait time is stored in the register in increments of 37.76 µs. This register is also preset, automatically, for
every new protocol selection. Sending a Reset FIFO (0x0F) direct command after a TX Complete interrupt
will disable this feature.
Table 6-28 describes the RX No Response Wait Time register.
Table 6-28. RX No Response Wait Time Register (0x07)
Function: Defines the time when "no response" interrupt is sent; only for ISO/IEC 15693
Default: 0x0E at POR = H or EN = L and at each write to ISO Control register
Bit Name Function Description
B7 NoResp7 No response MSB Defines the time when "no response" interrupt is sent. It starts from the end of
TX EOF. RX no response wait range is 37.76 µs to 9628 µs (1 to 255), step
size is: 37.76 µs.
The following default timings are preset by the ISO Control register (0x01):
390 µs Reserved
529 µs for all protocols supported, but not listed here
604 µs Reserved
755 µs ISO/IEC 15693 high data rate (TI Tag-It HF-I)
1812 µs ISO/IEC 15693 low data rate (TI Tag-It HF-I)
B6 NoResp6
B5 NoResp5
B4 NoResp4
B3 NoResp3
B2 NoResp2
B1 NoResp1
B0 NoResp0 No response LSB
56
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
6.14.3.2.7 RX Wait Time Register (0x08)
The RX-wait-time timer is controlled by the value in the RX wait time register 0x08. This timer defines the
time after the end of the transmit operation in which the receive decoders are not active (held in reset
state). This prevents incorrect detections resulting from transients following the transmit operation. The
value of the RX wait time register defines this time in increments of 9.44 µs. This register is preset at
every write to ISO Control register 0x01 according to the minimum tag response time defined by each
standard.
Table 6-29 describes the RX Wait Time register.
Table 6-29. RX Wait Time Register (0x08)
Function: Defines the time after TX EOF when the RX input is disregarded for example, to block out electromagnetic disturbance
generated by the responding card.
Default: 0x1F at POR = H or EN = L and at each write toISO control register.
Bit Name Function Description
B7 Rxw7
RX wait time
Defines the time after the TX EOF during which the RX input is ignored. Time
starts from the end of TX EOF.
RX wait range is 9.44 µs to 2407 µs (1 to 255), Step size 9.44 µs.
The following default timings are preset by the ISO Control register (0x01):
9.44 µs FeliCa
66 µs ISO/IEC 14443 A and B
180 µs Reserved
293 µs ISO/IEC 15693 (TI Tag-It HF-I)
B6 Rxw6
B5 Rxw5
B4 Rxw4
B3 Rxw3
B2 Rxw2
B1 Rxw1
B1 Rxw0
57
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
6.14.3.2.8 Modulator and SYS_CLK Control Register (0x09)
The frequency of SYS_CLK (pin 27) is programmable by the bits B4 and B5 of this register. The frequency
of the TRF7964A system clock oscillator is divided by 1, 2 or 4 resulting in available SYS_CLK
frequencies of 13.56 MHz or 6.78 MHz or 3.39 MHz.
The ASK modulation depth is controlled by bits B0, B1 and B2. The range of ASK modulation is 7% to
30% or 100% (OOK). The selection between ASK and OOK (100%) modulation can also be done using
direct input OOK (pin 12). The direct control of OOK/ASK using OOK pin is only possible if the function is
enabled by setting B6 = 1 (en_ook_p) in this register (0x09) and the ISO Control Register (0x01, B6 = 1).
When configured this way, the MOD (pin 14) is used as input for the modulation signal.
Table 6-30 describes the Modulator and SYS_CLK Control register.
Table 6-30. Modulator and SYS_CLK Control Register (0x09)
Function: Controls the modulation input and depth, ASK / OOK control and clock output to external system (MCU)
Default: 0x91 at POR = H or EN = L, and at each write to ISO control register, except Clo1 and Clo0.
Bit Name Function Description
B7 27MHz Enables 27.12-MHz crystal Default = 1 (enabled)
B6 en_ook_p
1 = Enables external
selection of ASK or OOK
modulation
0 = Default operation as
defined in B0 to B2 (0x09)
Enable ASK/OOK pin (pin 12) for "on the fly change" between any preselected
ASK modulation as defined by B0 to B2 and OOK modulation:
If B6 is 1, pin 12 is configured as follows:
1 = OOK modulation
0 = Modulation as defined in B0 to B2 (0x09)
B5 Clo1 SYS_CLK output frequency
MSB
Clo1 Clo0 SYS_CLK Output
(if 13.56-MHz
crystal is used)
SYS_CLK Output
(if 27.12-MHz
crystal is used)
0 0 Disabled Disabled
0 1 3.39 MHz 6.78 MHz
B4 Clo0 SYS_CLK output frequency
LSB 1 0 6.78 MHz 13.56 MHz
1 1 13.56 MHz 27.12 MHz
B3 en_ana 1 = Sets pin 12 (ASK/OOK)
as an analog output
0 = Default For test and measurement purpose. ASK/OOK pin 12 can be used to monitor
the analog subcarrier signal before the digitizing with DC level equal to AGND.
B2 Pm2 Modulation depth MSB
Pm2 Pm1 Pm0 Mod Type and %
0 0 0 ASK 10%
0 0 1 OOK (100%)
B1 Pm1 Modulation depth 0 1 0 ASK 7%
0 1 1 ASK 8.5%
1 0 0 ASK 13%
B0 Pm0 Modulation depth LSB 1 0 1 ASK 16%
1 1 0 ASK 22%
1 1 1 ASK 30%
58
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
6.14.3.2.9 RX Special Setting Register (0x0A)
Table 6-31 describes the RX Special Setting register.
Table 6-31. RX Special Setting Register (0x0A)
Function: Sets the gains and filters directly
Default: 0x40 at POR = H or EN = L, and at each write to the ISO Control register 0x01. When bits B7, B6, B5 and B4 are all zero, the
filters are set for ISO/IEC 14443 B (240 kHz to 1.4 MHz).
Bit Name Function Description
B7 C212 Band-pass 110 kHz to 570 kHz Appropriate for 212-kHz subcarrier system (FeliCa)
B6 C424 Band-pass 200 kHz to 900 kHz Appropriate for 424-kHz subcarrier used in ISO/IEC 15693
B5 M848 Band-pass 450 kHz to 1.5 MHz Appropriate for Manchester-coded 848-kHz subcarrier used in
ISO/IEC 14443 A and B
B4 hbt Band-pass 100 kHz to 1.5 MHz
Gain reduced for 18 dB Appropriate for highest bit rate (848 kbps) used in high-bit-rate
ISO/IEC 14443
B3 gd1 00 = Gain reduction 0 dB
01 = Gain reduction for 5 dB
10 = Gain reduction for 10 dB
11 = Gain reduction for 15 dB Sets the RX gain reduction and reduces sensitivity
B2 gd2
B1 Reserved
B0 Reserved
NOTE
The setting of bits B4, B5, B6 and B7 to 0 selects bandpass characteristic of 240 kHz to 1.4
MHz. This is appropriate for ISO/IEC 14443 B, FeliCa protocol, and ISO/IEC 14443 A higher
bit rates of 212 kbps and 424 kbps.
59
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
6.14.3.2.10 Regulator and I/O Control Register (0x0B)
Table 6-32 describes the Regulator and I/O Control register.
Table 6-32. Regulator and I/O Control Register (0x0B)
Function: Control the three voltage regulators
Default: 0x87 at POR = H or EN = L
Bit Name Function Description
B7 auto_reg
0 = Manual settings; see B0
to B2 in Table 6-33 and
Table 6-34
1 = Automatic setting (see
Table 6-35 and Table 6-36)
Auto system sets VDD_RF = VIN 250 mV and VDD_A = VIN 250 mV and
VDD_X= VIN 250 mV, but not higher than 3.4 V.
B6 en_ext_pa Support for external power
amplifier Internal peak detectors are disabled, receiver inputs (RX_IN1 and RX_IN2)
accept externally demodulated subcarrier. At the same time ASK/OOK pin 12
becomes modulation output for external TX amplifier.
B5 io_low 1 = enable low peripheral
communication voltage When B5 = 1, maintains the output driving capabilities of the I/O pins connected
to the level shifter under low voltage operation. Should be set 1 when VDD_I/O
voltage is between 1.8 V to 2.7 V.
B4 Unused No function Default is 0.
B3 Unused No function Default is 0.
B2 vrs2 Voltage set MSB voltage
set LSB Vrs3_5 = L: VDD_RF, VDD_A, VDD_X range 2.7 V to 3.4 V; see Table 6-33 and
Table 6-34
B1 vrs1
B0 vrs0
Table 6-33. Supply-Regulator Setting Manual 5-V System
REGISTER OPTION BITS SETTING IN CONTROL REGISTER ACTION
B7 B6 B5 B4 B3 B2 B1 B0
00 1 5-V system
0B 0 Manual regulator setting
0B 0 1 1 1 VDD_RF = 5 V, VDD_A = 3.4 V, VDD_X = 3.4 V
0B 0 1 1 0 VDD_RF = 4.9 V, VDD_A = 3.4 V, VDD_X = 3.4 V
0B 0 1 0 1 VDD_RF = 4.8 V, VDD_A = 3.4 V, VDD_X = 3.4 V
0B 0 1 0 0 VDD_RF = 4.7 V, VDD_A = 3.4 V, VDD_X = 3.4 V
0B 0 0 1 1 VDD_RF = 4.6 V, VDD_A = 3.4 V, VDD_X = 3.4 V
0B 0 0 1 0 VDD_RF = 4.5 V, VDD_A = 3.4 V, VDD_X = 3.4 V
0B 0 0 0 1 VDD_RF = 4.4 V, VDD_A = 3.4 V, VDD_X = 3.4 V
0B 0 0 0 0 VDD_RF = 4.3 V, VDD_A = 3.4 V, VDD_X = 3.4 V
Table 6-34. Supply-Regulator Setting Manual 3-V System
REGISTER OPTION BITS SETTING IN CONTROL REGISTER ACTION
B7 B6 B5 B4 B3 B2 B1 B0
00 0 3-V system
0B 0 Manual regulator setting
0B 0 1 1 1 VDD_RF = 3.4 V, VDD_A and VDD_X = 3.4 V
0B 0 1 1 0 VDD_RF = 3.3 V, VDD_A and VDD_X = 3.3 V
0B 0 1 0 1 VDD_RF = 3.2 V, VDD_A and VDD_X = 3.2 V
0B 0 1 0 0 VDD_RF = 3.1 V, VDD_A and VDD_X = 3.1 V
0B 0 0 1 1 VDD_RF = 3.0 V, VDD_A and VDD_X = 3.0 V
0B 0 0 1 0 VDD_RF = 2.9 V, VDD_A and VDD_X = 2.9 V
0B 0 0 0 1 VDD_RF = 2.8 V, VDD_A and VDD_X = 2.8 V
0B 0 0 0 0 VDD_RF = 2.7 V, VDD_A and VDD_X = 2.7 V
60
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
(1) x = don't care
Table 6-35. Supply-Regulator Setting Automatic 5-V System
REGISTER OPTION BITS SETTING IN CONTROL REGISTER ACTION
B7 B6 B5 B4 B3 B2 B1 B0
00 1 5-V system
0B 1 x(1) 0 0 Automatic regulator setting 400-mV difference
(1) x = don't care
Table 6-36. Supply-Regulator Setting Automatic 3-V System
REGISTER OPTION BITS SETTING IN CONTROL REGISTER ACTION
B7 B6 B5 B4 B3 B2 B1 B0
00 0 3-V system
0B 1 x(1) 0 0 Automatic regulator setting 400-mV difference
6.14.3.3 Status Registers
6.14.3.3.1 IRQ Status Register (0x0C)
Table 6-37 describes the IRQ Status register.
Table 6-37. IRQ Status Register (0x0C)
Function: Information available about TRF7964A IRQ and TX/RX status
Default: 0x00 at POR = H or EN = L, and at each write to the ISO Control Register 0x01. It is also automatically reset at the end of a read
phase. The reset also removes the IRQ flag.
Bit Name Function Description
B7 Irq_tx IRQ set due to end of TX Signals that TX is in progress. The flag is set at the start of TX but the interrupt
request (IRQ = 1) is sent when TX is finished.
B6 Irg_srx IRQ set due to RX start Signals that RX SOF was received and RX is in progress. The flag is set at the
start of RX but the interrupt request (IRQ = 1) is sent when RX is finished.
B5 Irq_fifo Signals the FIFO level Signals FIFO high or low as set in the Adjustable FIFO IRQ Levels (0x14)
register
B4 Irq_err1 CRC error Indicates receive CRC error only if B7 (no RX CRC) of ISO Control register is
set to 0.
B3 Irq_err2 Parity error Indicates parity error for ISO/IEC 14443 A
B2 Irq_err3 Byte framing or EOF error Indicates framing error
B1 Irq_col Collision error Collision error for ISO/IEC 14443 A and ISO/IEC 15693 single subcarrier. Bit is
set if more then 6 or 7 (as defined in register 0x10) are detected in 1 bit period
of ISO/IEC 14443 A 106 kbps. Collision error bit can also be triggered by
external noise.
B0 Irq_noresp No response time interrupt No response within the "No-response time" defined in RX No Response Wait
Time register (0x07). Signals the MCU that the next slot command can be sent.
Only for ISO/IEC 15693.
To reset (clear) the register 0x0C and the IRQ line, the register must be read. During Transmit the
decoder is disabled, only bits B5 and B7 can be changed. During Receive only bit B6 can be changed, but
does not trigger the IRQ line immediately. The IRQ signal is set at the end of Transmit and Receive
phase.
61
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
6.14.3.3.2 Interrupt Mask Register (0x0D) and Collision Position Register (0x0E)
Table 6-38 describes the Interrupt Mask register. Table 6-39 describes the Collision Position register.
Table 6-38. Interrupt Mask Register (0x0D)
Default: 0x3E at POR = H and EN = L. Collision bits reset automatically after read operation.
Bit Name Function Description
B7 Col9 Bit position of collision MSB Supports ISO/IEC 14443 A
B6 Col8 Bit position of collision
B5 En_irq_fifo Interrupt enable for FIFO Default = 1
B4 En_irq_err1 Interrupt enable for CRC Default = 1
B3 En_irq_err2 Interrupt enable for Parity Default = 1
B2 En_irq_err3 Interrupt enable for Framing
error or EOF Default = 1
B1 En_irq_col Interrupt enable for collision
error Default = 1
B0 En_irq_noresp Enables no-response
interrupt Default = 0
Table 6-39. Collision Position Register (0x0E)
Function: Displays the bit position of collision or error
Default: 0x00 at POR = H and EN = L. Automatically reset after read operation.
Bit Name Function Description
B7 Col7 Bit position of collision MSB
ISO/IEC 14443 A mainly supported, in the other protocols this register shows
the bit position of error. Frame, SOF, EOF, parity, or CRC error.
B6 Col6
B5 Col5
B4 Col4
B3 Col3
B2 Col2
B1 Col1
B0 Col0 Bit position of collision LSB
62
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
6.14.3.3.3 RSSI Levels and Oscillator Status Register (0x0F)
Table 6-40 describes the RSSI Levels and Oscillator Status register.
Table 6-40. RSSI Levels and Oscillator Status Register (0x0F)
Function: Displays the signal strength on both reception channels and RF amplitude during RF-off state. The RSSI values are valid from
reception start till start of next transmission.
Bit Name Function Description
B7 Unused
B6 osc_ok Crystal oscillator stable
indicator 13.56-MHz frequency stable (approximately 200 µs)
B5 rssi_x2 MSB RSSI value of auxiliary
RX (RX_IN2) Auxiliary channel is by default RX_IN2. The input can be swapped by B3 = 1
(Chip Status Control register 0x00). If "swapped", the Auxiliary channel is
connected to RX_IN1 and, hence, the Auxiliary RSSI represents the signal level
at RX_IN1.
B4 rssi_x1 Auxiliary channel RSSI
B3 rssi_x0 MSB RSSI value of auxiliary
RX (RX_IN2)
B2 rssi_2 MSB RSSI value of main
RX (RX_IN1) Active channel is default and can be set with option bit B3 = 0 of Chip Status
Control register 0x00.
B1 rssi_1 Main channel RSSI
B0 rssi_0 LSB RSSI value of main RX
(RX_IN1)
RSSI measurement block is measuring the demodulated envelope signal (except in case of direct
command for RF amplitude measurement described later in direct commands section). The measuring
system is latching the peak value, so the RSSI level can be read after the end of receive packet. The
RSSI value is reset during next transmit action of the reader, so the new tag response level can be
measured. The RSSI levels calculated to the RF_IN1 and RF_IN2 are presented in Section 6.5.1.1 and
Section 6.5.1.2. The RSSI has 7 steps (3 bits) with 4-dB increment. The input level is the peak-to-peak
modulation level of RF signal measured on one side envelope (positive or negative).
6.14.3.3.4 Special Functions Register (0x10)
Table 6-41 describes the Special Functions register at address 0x10.
Table 6-41. Special Functions Register (0x10)
Function: User configurable options for ISO/IEC 14443 A specific operations
Bit Name Function Description
B7 Reserved Reserved
B6 Reserved Reserved
B5 par43 Disables parity checking for
ISO/IEC 14443 A
B4 next_slot_37us 0 = 18.88 µs
1 = 37.77 µs Sets the time grid for next slot command in ISO/IEC 15693
B3 Sp_dir_mode Bit stream transmit for
MIFARE at 106 kbps Enables direct mode for transmitting ISO/IEC 14443 A data, bypassing the
FIFO and feeding the data bit stream directly onto the encoder.
B2 4_bit_RX 0 = normal receive
1 = 4-bit receive Enable 4-bit replay for example, ACK, NACK used by some cards; for example,
MIFARE Ultralight
B1 14_anticoll 0 = anticollision framing
(0x93, 0x95, 0x97)
1 = normal framing (no
broken bytes)
Disable anticollision frames for ISO/IEC 14443 A (this bit should be set to 1
after anticollision is finished)
B0 col_7_6 0 = 7 subcarrier pulses
1 = 6 subcarrier pulses Selects the number of subcarrier pulses that trigger collision error in
ISO/IEC 14443 A at 106 kbps
63
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
6.14.3.3.5 Special Functions Register (0x11)
Table 6-42 describes the Special Functions register at address 0x11.
Table 6-42. Special Functions Register (0x11)
Function: Indicate IRQ status for RX operations.
Bit Name Function Description
B7 Reserved Reserved
B6 Reserved Reserved
B5 Reserved Reserved
B4 Reserved Reserved
B3 Reserved Reserved
B2 Reserved Reserved
B1 Reserved Reserved
B0 irg_srx Copy of the RX start signal
(Bit 6) of the IRQ Status
register (0x0C) Signals the RX SOF was received and the RX is in progress. IRQ when RX is
completed.
6.14.3.3.6 Adjustable FIFO IRQ Levels Register (0x14)
Table 6-43 describes the Adjustable FIFO IRQ Levels register.
Table 6-43. Adjustable FIFO IRQ Levels Register (0x14)
Function: Adjusts level at which FIFO indicates status by IRQ
Default: 0x00 at POR = H and EN = L
Bit Name Function Description
B7 Reserved Reserved
B6 Reserved Reserved
B5 Reserved Reserved
B4 Reserved Reserved
B3 Wlh_1 FIFO high IRQ level (during
RX)
Wlh_1
0
0
1
1
Wlh_0
0
1
0
1
IRQ Level
124
120
112
96
B2 Wlh_0
B1 Wll_1 FIFO low IRQ level (during
TX)
Wll_1
0
0
1
1
Wll_0
0
1
0
1
IRQ Level
4
8
16
32
B0 Wll_0
64
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
6.14.3.4 Test Registers
6.14.3.4.1 Test Register (0x1A)
Table 6-44 describes the Test register at address 0x1A.
Table 6-44. Test Register (0x1A) (for Test or Direct Use)
Default: 0x00 at POR = H and EN = L.
Bit Name Function Description
B7 OOK_Subc_In Subcarrier input OOK pin becomes decoder digital input
B6 MOD_Subc_Out Subcarrier output MOD pin becomes receiver digitized subcarrier output
B5 MOD_Direct Direct TX modulation and
RX reset MOD pin becomes input for TX modulation control by the MCU
B4 o_sel First stage output selection o_sel = L: First stage output used for analog out and digitizing
o_sel = H: Second Stage output used for analog out and digitizing
B3 low2 Second stage gain 6 dB,
HP corner frequency / 2
B2 low1 First stage gain –6 dB, HP
corner frequency / 2
B1 zun Input followers test
B0 Test_AGC AGC test, AGC level is
seen on rssi_210 bits
6.14.3.4.2 Test Register (0x1B)
Table 6-45 describes the Test register at address 0x1B.
Table 6-45. Test Register (0x1B) (for Test or Direct Use)
Default: 0x00 at POR = H and EN = L. When a test_dec or test_io is set IC is switched to test mode. Test Mode persists until a stop
condition arrives. At stop condition the test_dec and test_io bits are cleared.
Bit Name Function Description
B7
test_rf_level RF level test
B6
B5
B4
B3 test_io1 I/O test Not implemented
B2 test_io0
B1 test_dec Decoder test mode
B0 clock_su Coder clock 13.56 MHz For faster test of coders
65
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed DescriptionCopyright © 2012–2017, Texas Instruments Incorporated
6.14.3.5 FIFO Control Registers
Section 6.14.3.5.1 describes the FIFO Status register.
6.14.3.5.1 FIFO Status Register (0x1C)
Table 6-46. FIFO Status Register (0x1C)
Function: Number of bytes available to be read from FIFO (= N number of bytes, in hexadecimal)
Bit Name Function Description
B7 Foverflow FIFO overflow error Bit is set when FIFO has more than 127 bytes presented to it
B6 Fb6 FIFO bytes fb[6]
Bits B0:B6 indicate how many bytes are in the FIFO to be read out (= N
number of bytes, in hex)
B5 Fb5 FIFO bytes fb[5]
B4 Fb4 FIFO bytes fb[4]
B3 Fb3 FIFO bytes fb[3]
B2 Fb2 FIFO bytes fb[2]
B1 Fb1 FIFO bytes fb[1]
B0 Fb0 FIFO bytes fb[0]
66
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Detailed Description Copyright © 2012–2017, Texas Instruments Incorporated
6.14.3.5.2 TX Length Byte1 Register (0x1D), TX Length Byte2 Register (0x1E)
Table 6-47 describes the TX Length Byte1 register. Table 6-48 describes the TX Length Byte2 register.
Table 6-47. TX Length Byte1 Register (0x1D)
Function: High 2 nibbles of complete, intended bytes to be transferred through FIFO
Register default is set to 0x00 at POR and EN = 0. It is also automatically reset at TX EOF
Bit Name Function Description
B7 Txl11 Number of complete byte
bn[11]
High nibble of complete, intended bytes to be transmitted
B6 Txl10 Number of complete byte
bn[10]
B5 Txl9 Number of complete byte
bn[9]
B4 Txl8 Number of complete byte
bn[8]
B3 Txl7 Number of complete byte
bn[7]
Middle nibble of complete, intended bytes to be transmitted
B2 Txl6 Number of complete byte
bn[6]
B1 Txl5 Number of complete byte
bn[5]
B0 Txl4 Number of complete byte
bn[4]
Table 6-48. TX Length Byte2 Register (0x1E)
Function: Low nibbles of complete bytes to be transferred through FIFO; Information about a broken byte and number of bits to be
transferred from it
Default: 0x00 at POR and EN = 0. It is also automatically reset at TX EOF
Bit Name Function Description
B7 Txl3 Number of complete byte
bn[3]
Low nibble of complete, intended bytes to be transmitted
B6 Txl2 Number of complete byte
bn[2]
B5 Txl1 Number of complete byte
bn[1]
B4 Txl0 Number of complete byte
bn[0]
B3 Bb2 Broken byte number of bits
bb[2] Number of bits in the last broken byte to be transmitted.
Valid only when broken byte flag is set.
B2 Bb1 Broken byte number of bits
bb[1]
B1 Bb0 Broken byte number of bits
bb[0]
B0 Bbf Broken byte flag B0 = 1 indicates that last byte is not complete 8 bits wide.
GND
1500pF
1500pF
1200pF
1200pF
10pF
680pF
100pF 220pF
680pF
150nH330nH
GND
GND
27pF
GND
GNDGND
2.2uF
0.01uF
2.2uF
0.01uF
GND
GND
2.2uF0.01uF
GND
2.2uF
0.01uF
GND
27pF
GND
27pF
GND
1.5uH
68pF
GND
12pF
12pF
6.8k
GND
GND
10k
GND
GND
47k
0.1uF
100R
GND
GND
MC-921
GND
0
0
SMA-142-0701-801/806
GND
GND
2.2uF
0.01uF
GND
057-014-2
C2
C3
C4
C5
C6
C7
C10 C8
C9
L1L2
C11
C16
C15
C20
C19
C18
C17
C22
C21
C23 C24
L3
C14
C13
C12
R1
TCK
TMS
P4.0/TB0
P4.1/TB1
P4.2/TB2
P4.3/TB0
P4.4/TB1
P4.5/TB2
P4.6/TBOUTH/ACLK
P4.7/TBCLK
1
2
3
4
5
6
7
8
9
10
11
12
13
14
28
27
26
25
24
23
22
21 20
19
18
17
16
15
29
30
31
32
33
34
35
36
37
38
TP
39
40
R6
R5
C1
R4
X2
R2
R3
GND1
2
IN
1GND2 4
OUT 3
X3
VDD_X 32
OSC_IN 31
OSC_OUT 30
VSS_D 29
EN 28
SYS_CLK 27
DATA_CLK 26
EN2 25
I/O_7 24
I/O_6 23
I/O_5 22
I/O_4 21
I/O_3 20
I/O_2 19
VDD_A
1
VIN
2
VDD_PA
4
TX_OUT
5
VSS_PA
6
VDD_RF
3
I/O_1 18
I/0_0 17
BAND_GAP
11
VDD_I/O
16 VSS_A
15 MOD
14 IRQ
13 ASK/OOK
12
VSS_RX
7
RX_IN1
8
VSS
10 RX_IN2
9
GND(PA D)
33
C25C26
X4-1 X4-2
X4-3 X4-4
X4-5 X4-6
X4-7 X4-8
X4-9 X4-10
X4-11 X4-12
X4-13 X4-14
SYS_CLK
SYS_CLK
DATA_CLK
DATA_CLK
VIN
VIN
IRQ
IRQ
MOD
MOD
VDD_X
VDD_X
VDD_X
RST_NMI
RST_NMI
RST_NMI
TCK
TCK
TMS
TMS
TDI
TDI
TDO/TDI
TDO/TDI
VCC
VCC
VCC
VCC
VCC
RXD
TXD
ASK/OOK
ASK/OOK EN
EN
OSC_OUT
OSC_OUT
OSC_IN
OSC_IN
P3.0
P3.0
P3.2
P3.2
P3.1
P3.1
P3.6
P3.7
P4.2P4.2
JTAG
(+2.7VDC - 5.5VDC)
TRF7964A
67
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Applications, Implementation, and LayoutCopyright © 2012–2017, Texas Instruments Incorporated
7 Applications, Implementation, and Layout
NOTE
Information in the following Applications section is not part of the TI component specification,
and TI does not warrant its accuracy or completeness. TI's customers are responsible for
determining suitability of components for their purposes. Customers should validate and test
their design implementation to confirm system functionality.
7.1 TRF7964A Reader System Using SPI With SS Mode
7.1.1 General Application Considerations
Figure 7-1 shows and application schematic optimized for all TRF7964A modes using the Serial Port
Interface (SPI). Short SPI lines, proper isolation of radio frequency lines, and a proper ground area are
essential to avoid interference. The recommended clock frequency on the DATA_CLK line is 2 MHz. This
figure also shows matching to a 50-Ωport, which allows connecting to a properly matched 50-Ωantenna
circuit or RF measurement equipment (for example, a spectrum analyzer or power meter).
7.1.2 Schematic
Figure 7-1 shows a sample application schematic for SPI with an SS mode MCU interface.
Figure 7-1. Application Schematic SPI With SS Mode MCU Interface
Minimum MCU requirements depend on application requirements and coding style. If only one ISO
protocol or a limited command set of a protocol needs to be supported, MCU Flash and RAM
requirements can be significantly reduced. Recursive inventory and anticollision commands require more
RAM than single slotted operations. For example, an ISO/IEC 15693-only application that supports
anticollision needs approximately 7KB of flash memory and 500 bytes of RAM. In contrast, a full NFC
stack that supports peer-to-peer, card emulation, and reader/writer modes needs 65KB of flash memory
and 4KB of RAM. An MCU that can run its GPIOs at 13.56 MHz is required for direct mode 0 operations.
68
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Applications, Implementation, and Layout Copyright © 2012–2017, Texas Instruments Incorporated
7.2 Layout Considerations
Keep all decoupling capacitors as close to the IC as possible, with the high-frequency decoupling
capacitors (10 nF) closer than the low-frequency decoupling capacitors (2.2 µF).
Place ground vias as close as possible to the ground side of the capacitors and reader IC pins to minimize
possible ground loops.
TI recommends not using any inductor sizes smaller than 0603, as the output power can be compromised.
If smaller inductors are necessary, output performance must be confirmed in the final application.
Pay close attention to the required load capacitance of the crystal, and adjust the two external shunt
capacitors accordingly. Follow the recommendations of the crystal manufacturer for those values.
There should be a common ground plane for the digital and analog sections. The multiple ground sections
or islands should have vias that tie the different sections of the planes together.
Ensure that the exposed thermal pad at the center of the reader IC is properly laid out. It should be tied to
ground to help dissipate any heat from the package.
All trace line lengths should be made as short as possible, particularly the RF output path, crystal
connections, and control lines from the reader to the microprocessor. Proper placement of the TRF7964A,
microprocessor, crystal, and RF connection or connector help facilitate this.
Avoid crossing of digital lines under RF signal lines. Also, avoid crossing of digital lines with other digital
lines when possible. If the crossings are unavoidable, 90° crossings should be used to minimize coupling
of the lines.
Depending on the production test plan, consider possible implementations of test pads or test vias for use
during testing. The necessary pads or vias should be placed in accordance with the proposed test plan to
enable easy access to those test points.
If the system implementation is complex (for example, if the RFID reader module is a subsystem of a
greater system with other modules (microprocessors and clocks), special considerations should be taken
to ensure that there is no noise coupling into the supply lines. If needed, special filtering or regulator
considerations should be used to minimize or eliminate noise in these systems.
For more information/details on layout considerations, see the TRF796x HF-RFID Reader Layout Design
Guide.
7.3 Impedance Matching TX_Out (Pin 5) to 50
The output impedance of the TRF7964A when operated at full power out setting is nominally 4 + j0 (4
real). This impedance must be matched to a resonant circuit and TI recommends matching circuit from
4to 50 , as commercially available test equipment (for example, spectrum analyzers, power meters,
and network analyzers) are 50-systems. Figure 7-2 shows an impedance-matching reference circuit.
Figure 7-3 shows a Smith chart simulation based on this circuit. This section explains how the values were
calculated.
Starting with the 4-source, the process of going from 4 to 50 can be represented on a Smith Chart
simulator (available from http://www.fritz.dellsperger.net/). The elements are combined where appropriate
(see Figure 7-2).
TX_OUT
Pin 5
L1 L2
C2 and C3
Combination
C4, C4, and C7
Combination C8, C9, C10, and C11
Combination
50 W
(4.00 + j0.00) at 13.6 MHzW
ZL
3.0 nF
150.0 nH
1.2 nF
330.0 nH
256.0 pF
ZIN
69
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Applications, Implementation, and LayoutCopyright © 2012–2017, Texas Instruments Incorporated
Figure 7-2. Impedance Matching Circuit
Figure 7-3. Smith Chart Simulation
Resulting power out can be measured with a power meter or spectrum analyzer with power meter function
or other equipment capable of making a "hot" measurement. Observe maximum power input levels on test
equipment and use attenuators whenever available to avoid damage to equipment. Expected output
power levels under various operating conditions are shown in Table 6-20.
7.4 Reader Antenna Design Guidelines
For HF antenna design considerations using the TRF7964A, see these documents:
Antenna Matching for the TRF7960 RFID Reader
TRF7960TB HF RFID Reader Module User's Guide
Device Family TRF79 = NFC/RFID Transceiver
Revision A = Silicon Revision
Package See Packaging Information
or www.ti.com/package
Distribution R = Large Reel
T = Small Reel
Feature Set 64 = Feature Set
TRF79 64 A RHB R
Device Family
Feature Set
Revision
Package
Distribution
70
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Device and Documentation Support Copyright © 2012–2017, Texas Instruments Incorporated
8 Device and Documentation Support
8.1 Getting Started and Next Steps
For more information on the TI NFC/RFID devices and the tools and software that are available to help
with your development, visit Overview for NFC / RFID.
8.2 Device Nomenclature
To designate the stages in the product development cycle, TI assigns prefixes to the part numbers of
devices. Each commercial family member has one of three prefixes: x, p, or no prefix. These prefixes
represent evolutionary stages of product development from engineering prototypes (with prefix x) through
fully qualified production devices (with no prefix).
Device development evolutionary flow:
xTRF... Experimental device that is not necessarily representative of the electrical specifications of the
final device
pTRF... Final device that conforms to the electrical specifications of the final product but has not
completed quality and reliability verification
TRF... Fully qualified production device
Devices with a prefix of xor pare shipped against the following disclaimer:
"Developmental product is intended for internal evaluation purposes."
Production devices have been characterized fully, and the quality and reliability of the device have been
demonstrated fully. TI's standard warranty applies.
Predictions show that prototype devices have a greater failure rate than the standard production devices.
TI recommends that these devices not be used in any production system because their expected end-use
failure rate still is undefined. Only qualified production devices are to be used.
TI device nomenclature also includes a suffix with the device family name. This suffix indicates the
package type and, optionally, the temperature range. Figure 8-1 provides a legend for reading the
complete device name.
Figure 8-1. Device Nomenclature
71
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Device and Documentation SupportCopyright © 2012–2017, Texas Instruments Incorporated
8.3 Tools and Software
Design Kits and Evaluation Modules
NFC Transceiver Add-on Target Board Module The TRF7970ATB Evaluation Module lets the software
application developer get familiar with the functionality of the TRF7970A multiprotocol fully
integrated 13.56-MHz NFC/HF RFID IC on their Texas Instruments embedded
microcontroller platform of choice without having to worry about the RF section.
NFC Transceiver Booster Pack Plug-in Module The third-party provider DLP Design NFC/RFID
BoosterPack plug-in module (DLP-7970ABP) is an add-on board designed to fit all of TI’s
MCU LaunchPad development kits. This BoosterPack plug-in module lets the software
application developer get familiar with the functionality of the TRF7970A multiprotocol fully
integrated 13.56 MHz NFC and HF RFID IC on their TI embedded microcontroller platform of
choice without having to worry about developing the RF section.
NFC Transceiver Evaluation Module The TRF7970AEVM is a self-contained development platform that
can be used to evaluate the performance of NFC Transceiver TRF7970A. TRF7970A is a
multiprotocol fully integrated 13.56-MHz NFC/RFID transceiver IC. Along with the IC, the
evaluation module enables development and evaluation of custom firmware, customer
designed antennas, and potential transponders for a variety of NFC/RFID applications.
8.4 Documentation Support
The following documents describe the TRF7964A device. Copies of these documents are available on the
Internet at www.ti.com.
Receiving Notification of Document Updates
To receive notification of documentation updates—including silicon errata—go to the product folder for
your device on ti.com (for example, TRF7964A). In the upper-right corner, click the "Alert me" button. This
registers you to receive a weekly digest of product information that has changed (if any). For change
details, check the revision history of any revised document.
Application Notes
Minimizing TRF79xx Current Use During PowerDown Mode This application report provides
recommendations on circuit and firmware design to reduce current consumption in power-
down mode for the TRF79xx family of devices (TRF796x, TRF796xA, and TRF7970A).
Various designs are considered, and they are analyzed based on their current consumption.
This application report is particularly targeted for dual-voltage systems that are powered by
battery.
NFC/HF RFID Reader/Writer Using the TRF7970A The near field communication (NFC) market is
emerging into multiple fields including medical, consumer, retail, industrial, automotive, and
smart grid. Reader/writer is one of the three operational modes supported by the TRF7970A.
When using reader/writer mode, the user can configure the TRF7970A to read type 2, type
3, type 4A, type 4B, and type 5 tag platforms, also called transponders. The tags can store
NFC data exchange format (NDEF) messages or proprietary defined data. This application
report describes the fundamental concepts of reader/writer mode and how to properly
configure the TRF7907A transceiver for each supported technology.
TRF7970A NFC Reader Antenna MultiplexingThis application report describes the implementation of
multiple reader antennas with a single TRF7970A NFC transceiver IC. For demonstration
purposes, the MSP430F5529 LaunchPad development kit with TRF7970A BoosterPack
plug-in module are used. The demo supports ISO/IEC 15693, and ISO/IEC 14443 A and B
communication protocols.
72
TRF7964A
SLOS787I MAY 2012REVISED MARCH 2017
www.ti.com
Submit Documentation Feedback
Product Folder Links: TRF7964A
Device and Documentation Support Copyright © 2012–2017, Texas Instruments Incorporated
NFC/RFID Reader Ultra-Low-Power Card Presence Detect With MSP430 and TRF79xxANFC and
RFID reader battery-powered applications must have a defined and limited energy
consumption budget as well as low cost for a product to be realized. Techniques and
strategies have emerged over the years for the card presence detection that attempt to
address both concerns. The intent of this application report is to contribute to these
techniques and strategies by offering an advancement expressed by adding a simple circuit
and small firmware control logic loop to an existing design, which offers dramatic
improvement over previously identified card detection solutions.
8.5 Community Resources
The following links connect to TI community resources. Linked contents are provided "AS IS" by the
respective contributors. They do not constitute TI specifications and do not necessarily reflect TI's views;
see TI's Terms of Use.
TI E2E™ Community
TI's Engineer-to-Engineer (E2E) Community. Created to foster collaboration among engineers. At
e2e.ti.com, you can ask questions, share knowledge, explore ideas, and help solve problems with fellow
engineers.
8.6 Trademarks
E2E is a trademark of Texas Instruments.
MIFARE is a trademark of NXP Semiconductors.
FeliCa is a trademark of Sony Corporation.
8.7 Electrostatic Discharge Caution
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
8.8 Glossary
SLYZ022 TI Glossary.
This glossary lists and explains terms, acronyms and definitions.
73
TRF7964A
www.ti.com
SLOS787I MAY 2012REVISED MARCH 2017
Submit Documentation Feedback
Product Folder Links: TRF7964A
Mechanical, Packaging, and Orderable InformationCopyright © 2012–2017, Texas Instruments Incorporated
9 Mechanical, Packaging, and Orderable Information
The following pages include mechanical, packaging, and orderable information. This information is the
most current data available for the designated devices. This data is subject to change without notice and
revision of this document. For browser-based versions of this data sheet, refer to the left-hand navigation.
PACKAGE OPTION ADDENDUM
www.ti.com 24-Oct-2015
Addendum-Page 1
PACKAGING INFORMATION
Orderable Device Status
(1)
Package Type Package
Drawing Pins Package
Qty Eco Plan
(2)
Lead/Ball Finish
(6)
MSL Peak Temp
(3)
Op Temp (°C) Device Marking
(4/5)
Samples
TRF7964ARHBR ACTIVE VQFN RHB 32 3000 Green (RoHS
& no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR -40 to 110 TRF
7964A
TRF7964ARHBT ACTIVE VQFN RHB 32 250 Green (RoHS
& no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR -40 to 110 TRF
7964A
(1) The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3) MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device.
(5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation
of the previous line and the two combined represent the entire Device Marking for that device.
(6) Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish
value exceeds the maximum column width.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
PACKAGE OPTION ADDENDUM
www.ti.com 24-Oct-2015
Addendum-Page 2
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device Package
Type Package
Drawing Pins SPQ Reel
Diameter
(mm)
Reel
Width
W1 (mm)
A0
(mm) B0
(mm) K0
(mm) P1
(mm) W
(mm) Pin1
Quadrant
TRF7964ARHBR VQFN RHB 32 3000 330.0 12.4 5.3 5.3 1.5 8.0 12.0 Q2
TRF7964ARHBT VQFN RHB 32 250 180.0 12.4 5.3 5.3 1.5 8.0 12.0 Q2
PACKAGE MATERIALS INFORMATION
www.ti.com 6-Apr-2016
Pack Materials-Page 1
*All dimensions are nominal
Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm)
TRF7964ARHBR VQFN RHB 32 3000 367.0 367.0 35.0
TRF7964ARHBT VQFN RHB 32 250 210.0 185.0 35.0
PACKAGE MATERIALS INFORMATION
www.ti.com 6-Apr-2016
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated (TI) reserves the right to make corrections, enhancements, improvements and other changes to its
semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers
should obtain the latest relevant information before placing orders and should verify that such information is current and complete.
TI’s published terms of sale for semiconductor products (http://www.ti.com/sc/docs/stdterms.htm) apply to the sale of packaged integrated
circuit products that TI has qualified and released to market. Additional terms may apply to the use or sale of other types of TI products and
services.
Reproduction of significant portions of TI information in TI data sheets is permissible only if reproduction is without alteration and is
accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such reproduced
documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements
different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the
associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.
Buyers and others who are developing systems that incorporate TI products (collectively, “Designers”) understand and agree that Designers
remain responsible for using their independent analysis, evaluation and judgment in designing their applications and that Designers have
full and exclusive responsibility to assure the safety of Designers' applications and compliance of their applications (and of all TI products
used in or for Designers’ applications) with all applicable regulations, laws and other applicable requirements. Designer represents that, with
respect to their applications, Designer has all the necessary expertise to create and implement safeguards that (1) anticipate dangerous
consequences of failures, (2) monitor failures and their consequences, and (3) lessen the likelihood of failures that might cause harm and
take appropriate actions. Designer agrees that prior to using or distributing any applications that include TI products, Designer will
thoroughly test such applications and the functionality of such TI products as used in such applications.
TI’s provision of technical, application or other design advice, quality characterization, reliability data or other services or information,
including, but not limited to, reference designs and materials relating to evaluation modules, (collectively, “TI Resources”) are intended to
assist designers who are developing applications that incorporate TI products; by downloading, accessing or using TI Resources in any
way, Designer (individually or, if Designer is acting on behalf of a company, Designer’s company) agrees to use any particular TI Resource
solely for this purpose and subject to the terms of this Notice.
TI’s provision of TI Resources does not expand or otherwise alter TI’s applicable published warranties or warranty disclaimers for TI
products, and no additional obligations or liabilities arise from TI providing such TI Resources. TI reserves the right to make corrections,
enhancements, improvements and other changes to its TI Resources. TI has not conducted any testing other than that specifically
described in the published documentation for a particular TI Resource.
Designer is authorized to use, copy and modify any individual TI Resource only in connection with the development of applications that
include the TI product(s) identified in such TI Resource. NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE
TO ANY OTHER TI INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY TECHNOLOGY OR INTELLECTUAL PROPERTY
RIGHT OF TI OR ANY THIRD PARTY IS GRANTED HEREIN, including but not limited to any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
regarding or referencing third-party products or services does not constitute a license to use such products or services, or a warranty or
endorsement thereof. Use of TI Resources may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
TI RESOURCES ARE PROVIDED “AS IS” AND WITH ALL FAULTS. TI DISCLAIMS ALL OTHER WARRANTIES OR
REPRESENTATIONS, EXPRESS OR IMPLIED, REGARDING RESOURCES OR USE THEREOF, INCLUDING BUT NOT LIMITED TO
ACCURACY OR COMPLETENESS, TITLE, ANY EPIDEMIC FAILURE WARRANTY AND ANY IMPLIED WARRANTIES OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL
PROPERTY RIGHTS. TI SHALL NOT BE LIABLE FOR AND SHALL NOT DEFEND OR INDEMNIFY DESIGNER AGAINST ANY CLAIM,
INCLUDING BUT NOT LIMITED TO ANY INFRINGEMENT CLAIM THAT RELATES TO OR IS BASED ON ANY COMBINATION OF
PRODUCTS EVEN IF DESCRIBED IN TI RESOURCES OR OTHERWISE. IN NO EVENT SHALL TI BE LIABLE FOR ANY ACTUAL,
DIRECT, SPECIAL, COLLATERAL, INDIRECT, PUNITIVE, INCIDENTAL, CONSEQUENTIAL OR EXEMPLARY DAMAGES IN
CONNECTION WITH OR ARISING OUT OF TI RESOURCES OR USE THEREOF, AND REGARDLESS OF WHETHER TI HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Unless TI has explicitly designated an individual product as meeting the requirements of a particular industry standard (e.g., ISO/TS 16949
and ISO 26262), TI is not responsible for any failure to meet such industry standard requirements.
Where TI specifically promotes products as facilitating functional safety or as compliant with industry functional safety standards, such
products are intended to help enable customers to design and create their own applications that meet applicable functional safety standards
and requirements. Using products in an application does not by itself establish any safety features in the application. Designers must
ensure compliance with safety-related requirements and standards applicable to their applications. Designer may not use any TI products in
life-critical medical equipment unless authorized officers of the parties have executed a special contract specifically governing such use.
Life-critical medical equipment is medical equipment where failure of such equipment would cause serious bodily injury or death (e.g., life
support, pacemakers, defibrillators, heart pumps, neurostimulators, and implantables). Such equipment includes, without limitation, all
medical devices identified by the U.S. Food and Drug Administration as Class III devices and equivalent classifications outside the U.S.
TI may expressly designate certain products as completing a particular qualification (e.g., Q100, Military Grade, or Enhanced Product).
Designers agree that it has the necessary expertise to select the product with the appropriate qualification designation for their applications
and that proper product selection is at Designers’ own risk. Designers are solely responsible for compliance with all legal and regulatory
requirements in connection with such selection.
Designer will fully indemnify TI and its representatives against any damages, costs, losses, and/or liabilities arising out of Designer’s non-
compliance with the terms and provisions of this Notice.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2017, Texas Instruments Incorporated
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Texas Instruments:
TRF7964ARHBR TRF7964ARHBT