MITSUBISHI GATE TURN-OFF THYRISTORS FG6000AU-120D HIGH POWER INVERTER USE PRESS PACK TYPE FG6000AU-120D OUTLINE DRAWING Dimension in mm GATE (WHITE) 300 8 AUXILIARY CATHODE CONNECTOR (RED) 0.4 min 0.4 min ITQRM Repetitive controllable on-state current ...........6000A IT(AV) Average on-state current .....................1500A QRR Repetitive peak off state voltage .........6000V Anode short type 35 0.5 190 max 130 0.2 3.6 0.2 DEPTH 2.2 0.2 CATHODE TYPE NAME 130 0.2 190 max ANODE 3.6 0.2 DEPTH 2.2 0.2 APPLICATION Inverters, Converters, DC choppers, Induction heating, DC to DC converters. MAXIMUM RATINGS Symbol VRRM VRSM VR(DC) VDRM VDSM VD(DC) Voltage class 120D 22 22 22 6000 6000 4800 Parameter Repetitive peak reverse voltage Non-repetitive peak reverse voltage DC reverse voltage Repetitive peak off-state voltage+ Non-repetitive peak off-state voltage+ DC off-state voltage+ Unit V V V V V V + : VGK = -2V Symbol ITQRM IT(RMS) IT(AV) ITSM I2t diT/dt VFGM VRGM IFGM IRGM PFGM PRGM PFG(AV) PRG(AV) Tj Tstg -- -- Parameter Repetitive controllable on-state current RMS on-state current Average on-state current Surge (non-repetitive) on-state current Current-squared, time integration Critical rate of rise of on-state current Peak forward gate voltage Peak reverse gate voltage Peak forward gate current Peak gate reverse current Peak forward gate power dissipation Peak reverse gate power dissipation Average forward gate power dissipation Average reverse gate power dissipation Junction temperature Storage temperature Mounting force required Weight Conditions VD = 3000V, VDM = 5500V, Tj = 125C, CS = 6.0F, LS = 0.2H f = 60Hz, sine wave = 180, Tf = 72C One half cycle at 60Hz One cycle at 60Hz VD = 3000V, IGM = 90A, Tj = 125C Recommended value 108 Standard value Ratings 6000 3100 2000 40 6.7 x 106 500 10 22 200 2400 2000 50 140 630 -40 ~ +125 -40 ~ +150 98 ~ 118 4600 Unit A A A kA A2s A/s V V A A W kW W W C C kN g Aug.1998 http://store.iiic.cc/ MITSUBISHI GATE TURN-OFF THYRISTORS FG6000AU-120D HIGH POWER INVERTER USE PRESS PACK TYPE ELECTRICAL CHARACTERISTICS Symbol Parameter Test conditions VTM IRRM IDRM IRG dv/dt tgt On-state voltage Repetitive peak reverse current Repetitive peak off-state current Reverse gate current Critical rate of rise of off-state voltage Turn-on time Tj = 125C, ITM = 6000A, Instantaneous measurment Tj = 125C, VRRM Applied Tj = 125C, VDRM Applied, VGK = -2V Tj = 125C, VRG = 22V Tj = 125C, VD = 3000V, VDM = 5500V, VGK = -2V Tj = 125C, ITM = 6000A, IGM = 90A, VD = 3000V tgq Turn-off time IGQM VGT IGT Rth(j-f) Peak gate turn-off current Gate trigger voltage Gate trigger current Thermal resistance Tj = 125C, ITM = 6000A, VDM = 5500V, diGQ/dt = -80A/s VRG = 20V, CS = 6.0F, LS = 0.2H DC METHOD : VD = 24V, RL = 0.1, Tj = 25C Junction to fin Min -- -- -- -- 1000 -- Limits Typ -- -- -- -- -- -- -- -- -- -- -- -- 1800 -- -- -- Max 6.0 100 320 100 -- 10 30 -- 1.5 8.4 0.0044 Unit V mA mA mA V/s s s A V A C/W MAXIMUM ON-STATE CHARACTERISTIC 104 Tj = 125C 7 5 3 2 103 7 5 3 2 102 0 2 4 6 8 RATED SURGE ON-STATE CURRENT 50 SURGE ON-STATE CURRENT (kA) ON-STATE CURRENT (A) PERFORMANCE CURVES 40 30 20 10 0 0 10 10 ON-STATE VOLTAGE (V) 102 PFGM = 2000W 101 VGT = 1.5V PFG(AV) = 140W 100 7 5 3 2 Tj = 25C IGT = 8.4A THERMAL IMPEDANCE (C/W) GATE VOLTAGE (V) 7 5 3 2 7 5 3 2 2 3 5 7 102 MAXIMUM THERMAL IMPEDANCE CHARACTERISTIC (JUNCTION TO FIN) 100 2 3 5 7 101 0.008 GATE CHARACTERISTICS VFGM = 10V 5 7 101 CONDUCTION TIME (CYCLES AT 60Hz) 103 7 5 3 2 2 3 IFGM = 200A 10-1 -1 10 2 3 5 7100 2 3 5 7101 2 3 5 7 102 2 3 5 7 103 GATE CURRENT (mA) 0.007 0.006 0.005 0.004 0.003 0.002 0.001 0 10-3 2 3 5 710-2 2 3 5 710-1 2 3 5 7 100 TIME (s) Aug.1998 http://store.iiic.cc/ MITSUBISHI GATE TURN-OFF THYRISTORS FG6000AU-120D MAXIMUM ON-STATE POWER DISSIPATION CHARACTERISTICS (SINGLE-PHASE HALF WAVE) 16000 160 14000 140 12000 360 RESISTIVE, INDUCTIVE 60 LOAD = 30 10000 8000 120 90 180 6000 4000 ALLOWABLE FIN TEMPERATURE VS. AVERAGE ON-STATE CURRENT (SINGLE-PHASE HALF WAVE) FIN TEMPERATURE (C) ON-STATE POWER DISSIPATION (W) HIGH POWER INVERTER USE PRESS PACK TYPE 2000 0 80 60 = 30 60 40 90 120 180 20 0 400 800 1200 1600 0 2000 MAXIMUM ON-STATE POWER DISSIPATION CHARACTERISTICS (RECTANGULAR WAVE) 16000 160 14000 140 10000 = 30 8000 60 FIN TEMPERATURE (C) 12000 180 120 90 6000 4000 360 RESISTIVE, INDUCTIVE LOAD 2000 0 400 800 1200 1600 2000 ALLOWABLE FIN TEMPERATURE VS. AVERAGE ON-STATE CURRENT (RECTANGULAR WAVE) DC 270 0 AVERAGE ON-STATE CURRENT (A) 120 360 RESISTIVE, INDUCTIVE LOAD 100 80 60 = 30 40 0 500 1000 1500 2000 2500 3000 3500 4000 90 180 DC 120 270 60 20 0 500 1000 1500 2000 2500 3000 3500 4000 AVERAGE ON-STATE CURRENT (A) AVERAGE ON-STATE CURRENT (A) GATE TRIGGER CURRENT, GATE TRIGGER VOLTAGE VS. JUNCTION TEMPERATURE (TYPICAL) 25 TURN ON TIME, TURN ON DELAY TIME VS. TURN ON GATE CURRENT (TYPICAL) 8 VD = 24V RL = 0.1 DC METHOD 20 15 10 IGT 5 VGT 0 -40 0 40 80 120 JUNCTION TEMPERATURE (C) 160 TURN ON TIME tgt, TURN ON DELAY TIME td (s) ON-STATE POWER DISSIPATION (W) GATE TRIGGER CURRENT (A), GATE TRIGGER VOLTAGE (V) 360 RESISTIVE, INDUCTIVE LOAD 100 AVERAGE ON-STATE CURRENT (A) 0 120 IT = 6000A VD = 3000V diT/dt = 500A/s diG/dt = 30A/s CS = 6.0F RS = 5.0 Tj = 125C 6 4 tgt 2 0 td 0 40 80 120 160 200 TURN ON GATE CURRENT (A) Aug.1998 http://store.iiic.cc/ MITSUBISHI GATE TURN-OFF THYRISTORS FG6000AU-120D TURN OFF TIME, TURN OFF STORAGE TIME VS. TURN OFF CURRENT (TYPICAL) 50 VD = 3000V VDM = 5500V diGQ/dt = -80A/s VGR = 17V CS = 6.0F LS = 0.2H Tj = 125C 40 30 tgq 20 ts 10 0 2000 4000 6000 8000 TURN OFF CURRENT (A) TURN OFF TIME tgq, TURN OFF STORAGE TIME ts (s) TURN OFF TIME tgq CTURN OFF STORAGE TIME ts (s) HIGH POWER INVERTER USE PRESS PACK TYPE TURN OFF TIME, TURN OFF STORAGE TIME VS. RATE OF RISE OF TURN OFF GATE CURRENT (TYPICAL) 50 VD = 3000V VDM = 5500V IT = 6000A VRG = 17V CS = 6.0F LS = 0.2H Tj = 125C 40 tgq 30 ts 20 10 0 TURN OFF GATE CURRENT (A) TURN OFF GATE CURRENT (A) 1500 1000 4000 6000 VD = 3000V VDM = 5500V IT = 6000A 2000 VRG = 17V CS = 6.0F LS = 0.2H Tj = 125C 1500 1000 500 8000 40 60 80 100 120 140 160 TURN ON SWITCHING ENERGY (TYPICAL) TURN OFF SWITCHING ENERGY (TYPICAL) 20 SWITCHING ENERGY Eoff (J/P) SWITCHING ENERGY Eon (J/P) 20 RATE OF RISE OF TURN OFF GATE CURRENT (A/s) VD = 3000V IGM = 90A diT/dt = 300A /s diG/dt = 30A/s 2.0 CS = 6.0F RS = 5.0 Tj = 125C 1.5 1.0 0 0 TURN OFF CURRENT (A) 2.5 0.5 80 100 120 140 160 2500 VD = 3000V VDM = 5500V diGQ/dt = -80A/s VRG = 17V 2000 CS = 6.0F LS = 0.2H Tj = 125C 2000 60 TURN OFF GATE CURRENT VS. RATE OF RISE OF GATE CURRENT (TYPICAL) 2500 0 40 RATE OF RISE OF TURN OFF GATE CURRENT (A/s) TURN OFF GATE CURRENT VS. TURN OFF CURRENT (TYPICAL) 500 20 2000 4000 6000 8000 TURN ON CURRENT (A) 15 10 VD = 3000V VDM = 5500V diGQ/df = -80A/s VRG = 17V CS = 6.0F LS = 0.2H Tj = 125C 5 0 0 2000 4000 6000 8000 TURN OFF CURRENT (A) Aug.1998 http://store.iiic.cc/