tyca / Electronics Instruction Sheet OPTIMATE* Active Device Mounts A089082 and Coupling Bushings for (was IS 9082) ANP FSMA Fiber-Optic Connectors 19DEC O01 RevA PGB Mount FSMA ADM Connector Coupling Bushing Alignment Ring Screws Panel Mount ADM KIT HARDWARE INCLUDED PART KIT MOUNTING MATING NUMBER TYPE PACKAGE | DUST O-RING JAM NUT AND NO, 2-56 | ALIGNMENT CAP LOCKWASHER SCREWS RING 501049-1 Coupling Panel 2 1 Each 501050-1 | Bushing Panel 2 1 1 Each 501052-1 Panel 1 1 Each 1 501055-1 PGB/Panel 10-18, 1 1 Each 2 1 ADM TO-46, 502136-1 PCB/Panel TO-5? 1 1 Each 2 1 502136-2 PCB/Panel 1 1 Each 2 1 Figure Tf 1. INTRODUCTION 2. DESCRIPTION Coupling bushings are used to make fibertofiber This instruction sheet covers the AMP OPTIMATE connections between two FSMA connectors. Two activa device mounts (ADM) and coupling bushings, versions are available; one version has an O-ring for listed in Figure 1, which are used with FSMA 905 sealing, the other version does not. All bushings are (Type |) and FSMA 906 (Type II) fiberoptic supplied with a nut and a lockwasher for panel connectors. mounting. ADMs house active devices, such as sources and NOTE Dimensions on this sheet are in millimeters detectors, and mate them with optical fibers that are [followed by inch equivalents in brackets]. terminated with FSMA connectors. ADMs are Figures and illustrations are for identification only available in three mounting styles: and are not drawn to scale. Panel mount Printed-circuit (pc) board mount Reasons for reissue are provided in Section 5, Printed-circuit board mount with panel flange for REVISION SUMMARY. either pc board or panel mounting 2001 Tyco Electronics Corporation, Harrisburg, PA. This controlled document is subject to change. TOOLING ASSISTANCE CENTER 1-800-722-1111 10f3 All Intemational Rights Reserved. For latest revision call the AMP FAX* number. AMP FAX/PRODUCT INFO 1-800-822-6752 AMP and Tyco are trademarks. For Regional Customer Service, visit our website at LOC B *Trademark www.tycoelectronics.comtyco / Electronics AMP Active Device Mounts and Coupling Bushings 408-9082 All ADMs are supplied with an alignment ring that fits around the active device to center it in the mount. The maximum recommended panel thickness is 1.575 mm [-062in.]. Figure 1 lists the hardware supplied with the various ADMs. The ADMs accommodate active devices packaged in TO-18/TO-46/TO-52 cans and have a slot that matches the tab on the can to provide consistent orientation of the device in the ADM. Figure 2 provides the dimensional information for the bushings and ADMs that is required for planning pe board layouts or panel cutouts. 3. ASSEMBLY AND INSTALLATION 3.1. Coupling Bushings 1. Ifan O-ring is needed, seat the O-ring in the grooved flange of the bushing. 2. Install the bushing in the cutout and secure it with the lockwasher and nut. 3. Connect the FSMA connectors to the bushing. The FSMA 906 (Type Il) connector requires the installation of the long alignment sleeve that is supplied with the connector. 3.2. ADMs The active device can be installed on, and soldered to, the pe board either before or after it is placed in the ADM. Make sure that your choice fs compatible with other assembly considerations. 1. Place the alignment ring around the active device and insert it into the rear of the ADM. Make sure that the tab on the device is in the slot of the ADM. 2. Secure the ADM to its mounting as follows: Panel Mounting: Install the ADM into the cutout and secure it with the lockwasher and nut. PC-Board Mounting: Secure the ADM to the board with the mounting screws. 3. Connect the FSMA connector to the ADM. The FSMA 906 (Type II} connector requires the short alignment sleeve that is supplied with the connector. 4. REPLACEMENT Order additional FSMA coupling bushings and ADMs through your Tyco Electronics representative, or call 1-800-526-5142, or send a facsimile of your purchase order to 717-986-7605, or write to: CUSTOMER SERVICE (38-35) TYCO ELECTRONICS CORPORATION P.O. BOX 2608 HARRISBURG, PA 17105-3608 5. REVISION SUMMARY Since the previous release of this document, the following changes were made: Per EC o990-1641-01 Updated document to corporate requirements * Removed cbsolate part numbers in Figure 1 and updated artwork * Added 905 to FSMA 905 (Type |) and 906 to FSMA 906 (Type II) * Updated dimensions, added part numbers, and added Coupling Bushing 5010501 artwork in Figure 2 * Removed all references to ADM panel mount with O-ring seal 20f3 Rev Atyca / Electronics Active Device Mounts and Coupling Bushings 408-9082 AMP ping evening Coupling Bushing 501049-1 Coupling Bushing 601050-1 1/4-36 UNS-2A 1/4-36 UNS-2A 11.73 13.66 a 9.53 J [462] . 11.09 A 1538) [375] 19.63 [437] 23.49 [.773] - [.925] ADM Panel Mount 501052-1 ADM PCB Mount and PCB Panel Mount 01055-1, 502136-1, and 502136-2 1/4-36 UNS-2A 7.16 4/4-36 UNS-2A f [282] N TE if wilt | 9.27 9.53 _| L 9.27 11.68 [:365] [375] [:365] [460] e 15.11 __, 12.70 15.11 Dia. [595] [500] 7 m= [595] Suggested Footprint for PCB ADM Suggested Clearance Hole for PCB 501055-1, 502136-1, and 502136-2 and Panel Mount ADM 502136-1 and 502136-2 2.39 [.094] Dia. 6.53 G) + [.257] 9.52 [375] 2.79 [.110] Suggested Clearance Hole for PCB Suggested Clearance Hole for and Panel Mount ADM BulkheadMount Coupling Bushing 501055-1 and Panel Mount ADM 01049-1, 501050-1, and 501052- 6.53 6.88 [257] [271] 7.29 [.287] Figure 2 RevA 3o0f3