ZXMP6A13FQ 60V P-CHANNEL ENHANCEMENT MODE MOSFET Product Summary Features Description This MOSFET utilizes a unique structure that combines the benefits of low on-resistance with fast switching speed, making it ideal for high-efficiency power management applications. Mechanical Data V(BR)DSS Max RDS(on) -60V 400m @ VGS = -10V 600m @ VGS = -4.5V Max ID TA = +25C -1.1A -0.9A Applications DC - DC converters Power management functions Relay and solenoid driving Motor control Fast switching speed Low input capacitance Low gate charge Totally Lead-Free & Fully RoHS compliant (Notes 1 & 2) Halogen and Antimony Free. "Green" Device (Note 3) Qualified to AEC-Q101 Standards for High Reliability PPAP Available Case: SOT23 Case Material: Molded Plastic, UL Flammability Classification Rating 94V-0 Moisture Sensitivity: Level 1 per J-STD-020 Terminals: Finish - Matte Tin Plated Leads, Solderable per MIL-STD-202, Method 208 Weight: 0.008 grams (approximate) SOT23 D S G D G S Equivalent Circuit Top View Pin Out Top View Ordering Information (Notes 4 & 5) Product ZXMP6A13FQTA Notes: Compliance Automotive Case SOT23 Quantity per reel 3,000 Units 1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant. 2. See http://www.diodes.com/quality/lead_free.html for more information about Diodes Incorporated's definitions of Halogen- and Antimony-free, "Green" and Lead-free. 3. Halogen- and Antimony-free "Green" products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and <1000ppm antimony compounds. 4. Automotive products are AEC-Q101 qualified and are PPAP capable. Automotive, AEC-Q101 and standard products are electrically and thermally the same, except where specified. 5. For packaging details, go to our website at http://www.diodes.com/products/packages.html Marking Information 7P6 ZXMP6A13FQ Document Number DS36684 Rev. 2 - 2 7P6 = Product Type Marking Code 1 of 8 www.diodes.com December 2013 (c) Diodes Incorporated ZXMP6A13FQ Maximum Ratings (@TA = +25C, unless otherwise specified.) Characteristic Symbol VDSS VGS Drain-Source Voltage Gate-Source Voltage Continuous Drain Current VGS = 10V TA = +70C Pulsed Drain Current (Note 8) Continuous Source Current (Body Diode) (Note 7) Pulsed Source Current (Body Diode) (Note 8) (Note 7) (Note 7) (Note 6) ID IDM IS ISM Value -60 20 -1.1 -0.8 -0.9 -4.0 -1.2 -4.0 Units V V Value 625 5 806 6.5 200 155 194 -55 to +150 Unit mW mW/C mW mW/C C/W C/W C/W C A A A A Thermal Characteristics (@TA = +25C, unless otherwise specified.) Characteristic Power Dissipation (Note 6) Linear Derating Factor Power Dissipation (Note 7) Linear Derating Factor Thermal Resistance, Junction to Ambient (Note 6) Thermal Resistance, Junction to Ambient (Note 7) Thermal Resistance, Junction to Leads (Note 9) Operating and Storage Temperature Range Notes: Symbol PD PD RJA RJA RJL TJ, TSTG 6. For a device surface mounted on 25mm x 25mm FR4 PCB with high coverage of single sided 1oz copper, in still air conditions 7. For a device surface mounted on FR4 PCB measured at t 5 secs. 8. Repetitive rating 25mm x 25mm FR4 PCB, D = 0.05 pulse width = 10s - pulse current limited by maximum junction temperature. 9. Thermal resistance from junction to solder-point (at the end of the collector lead). ZXMP6A13FQ Document Number DS36684 Rev. 2 - 2 2 of 8 www.diodes.com December 2013 (c) Diodes Incorporated ZXMP6A13FQ Thermal Characteristics 10 -ID Drain Current (A) Limited 1 DC 1s 100m 100ms 10ms 10m Single Pulse Tamb=25C 1 1ms 100s 10 -VDS Drain-Source Voltage (V) 100 Max Power Dissipation (W) 0.7 RDS(on) 0.6 0.5 0.4 0.3 0.2 0.1 0.0 0 20 200 T amb=25C 150 D=0.5 100 50 Single Pulse D=0.2 D=0.05 D=0.1 0 100 1m 10m 100m 1 Pulse Width (s) 10 Document Number DS36684 Rev. 2 - 2 80 100 120 140 160 100 1k Single Pulse T amb=25C 10 1 100 Transient Thermal Impedance ZXMP6A13FQ 60 Temperature (C) Derating Curve Maximum Power (W) Thermal Resistance (C/W) Safe Operating Area 40 1m 10m 100m 1 10 Pulse Width (s) 100 1k Pulse Power Dissipation 3 of 8 www.diodes.com December 2013 (c) Diodes Incorporated ZXMP6A13FQ Electrical Characteristics (@TA = +25C, unless otherwise specified.) Characteristic OFF CHARACTERISTICS Drain-Source Breakdown Voltage Zero Gate Voltage Drain Current Gate-Source Leakage ON CHARACTERISTICS Gate Threshold Voltage Symbol Min Typ Max Unit BVDSS IDSS IGSS -60 -0.5 100 V A nA ID = -250A, VGS = 0V VDS = -60V, VGS = 0V VGS = 20V, VDS = 0V VGS(th) -1.0 V Static Drain-Source On-Resistance (Note 10) RDS (ON) Forward Transconductance (Notes 10 and 12) Diode Forward Voltage (Note 10) Reverse Recovery Time (Note 12) Reverse Recovery Charge (Note 12) DYNAMIC CHARACTERISTICS (Note 12) Input Capacitance Output Capacitance Reverse Transfer Capacitance Turn-On Delay Time (Note 11) Turn-On Rise Time (Note 11) Turn-Off Delay Time (Note 11) Turn-Off Fall Time (Note 11) gfs VSD trr Qrr 1.8 -0.85 21.1 19.3 -3.0 0.4 0.6 -0.95 ID = -250A, VDS = VGS VGS = -10V, ID = -0.9A VGS = -4.5V, ID = -0.8A VDS = -15V, ID = -0.9A TJ = +25C, IS = -0.8A, VGS = 0V Ciss Coss Crss tD(on) tr tD(off) tf 219 25.7 20.5 1.6 2.2 11.2 5.7 Total Gate Charge (Note 11) Qg 2.9 Total Gate Charge (Note 11) Gate-Source Charge (Note 11) Gate-Drain Charge (Note 11) Qg Qgs Qgd 5.9 0.74 1.5 Notes: S V ns nC Test Condition TJ = +25C, IF = -0.9A, di/dt = 100A/s pF VDS = -30V, VGS = 0V f = 1.0MHz ns VDD = -30V, ID = -1A, RG 6.0 VGS = -10V nC VDS = -30V, VGS = -4.5V, ID = -0.9A nC VDS = -30V, VGS = -10V, ID = -0.9A 10. Measured under pulsed conditions. Pulse width = 300s. Duty cycle 2%. 11. Switching characteristics are independent of operating junction temperature. 12. For design aid only, not subject to production testing ZXMP6A13FQ Document Number DS36684 Rev. 2 - 2 4 of 8 www.diodes.com December 2013 (c) Diodes Incorporated ZXMP6A13FQ Typical Characteristics T = 25C 10V 10 4.5V -ID Drain Current (A) -ID Drain Current (A) 10 3.5V 3V 1 2.5V 2V 0.1 -VGS 10V 5V T = 150C 1 4.5V 3.5V 3V 2.5V 2V 0.1 1.5V -VGS 0.01 0.1 1 10 0.1 -ID Drain Current (A) -VDS = 10V 1 T = 150C T = 25C 1 2 3 4 5 -VGS Gate-Source Voltage (V) 2.5V 2V T = 25C 3V 3.5V 4V 5V 1 7V 10V 0.1 1 -ID Drain Current (A) 10 On-Resistance v Drain Current ZXMP6A13FQ Document Number DS36684 Rev. 2 - 2 -ISD Reverse Drain Current (A) RDS(on) Drain-Source On-Resistance -VGS 1.8 VGS = -10V 1.6 ID = -0.9A RDS(on) 1.4 1.2 VGS = VDS 1.0 ID = -250uA 0.8 VGS(th) 0.6 -50 0 50 100 Tj Junction Temperature (C) 150 Normalised Curves v Temperature Typical Transfer Characteristics 1.5V 10 Output Characteristics Normalised RDS(on) and VGS(th) Output Characteristics 0.1 1 -VDS Drain-Source Voltage (V) -VDS Drain-Source Voltage (V) 10 T = 150C T = 25C 1 0.1 0.01 0.4 0.6 0.8 1.0 1.2 1.4 -VSD Source-Drain Voltage (V) Source-Drain Diode Forward Voltage 5 of 8 www.diodes.com December 2013 (c) Diodes Incorporated ZXMP6A13FQ Typical Characteristics - continued C Capacitance (pF) VGS = 0V f = 1MHz CISS 200 COSS 100 CRSS 0 0.1 1 10 -VDS - Drain - Source Voltage (V) Capacitance v Drain-Source Voltage -VGS Gate-Source Voltage (V) 10 300 8 6 4 2 VDS = -30V ID = -0.9A 0 0 1 2 3 4 5 6 Q - Charge (nC) Gate-Source Voltage v Gate Charge Test Circuits ZXMP6A13FQ Document Number DS36684 Rev. 2 - 2 6 of 8 www.diodes.com December 2013 (c) Diodes Incorporated ZXMP6A13FQ Package Outline Dimensions Please see AP02002 at http://www.diodes.com/datasheets/ap02002.pdf for latest version. 7 l l A H SOT23 Dim Min Max Typ A 0.37 0.51 0.40 B 1.20 1.40 1.30 C 2.30 2.50 2.40 D 0.89 1.03 0.915 F 0.45 0.60 0.535 G 1.78 2.05 1.83 H 2.80 3.00 2.90 J 0.013 0.10 0.05 K 0.890 1.00 0.975 K1 0.903 1.10 1.025 L 0.45 0.61 0.55 L1 0.25 0.55 0.40 M 0.085 0.150 0.110 a 8 All Dimensions in mm J K 1 K a M A 1 L L B C D Suggested Pad Layout Please see AP02001 at http://www.diodes.com/datasheets/ap02001.pdf for the latest version. Y Z C X ZXMP6A13FQ Document Number DS36684 Rev. 2 - 2 Dimensions Value (in mm) Z 2.9 X 0.8 Y 0.9 C 2.0 E 1.35 E 7 of 8 www.diodes.com December 2013 (c) Diodes Incorporated ZXMP6A13FQ IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. This document is written in English but may be translated into multiple languages for reference. Only the English version of this document is the final and determinative format released by Diodes Incorporated. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright (c) 2013, Diodes Incorporated www.diodes.com ZXMP6A13FQ Document Number DS36684 Rev. 2 - 2 8 of 8 www.diodes.com December 2013 (c) Diodes Incorporated Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Diodes Incorporated: ZXMP6A13FQTA