Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notifica tion to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHA LL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: "901/902..." MAY BE REPLACED BY "Axxx".) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-522-67 52
Fax: 1-650-361-6297
DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL B E OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. © 2006-2016 Tyco Electronics Corporation. All rights reserved.
SPECIFICATION CONTROL DRAWING SCD 44AM115+
Title FIVE CONDUCTOR CABLE, SHIELDED, JACKETED,
GENERAL PURPOSE, 600 VOLT Date 8-15-16 Revision G
This specification sheet forms a part of the latest issue of Raychem Specification 44 and NEMA WC 27500, as applicable.
SHIELD - COPPER, COATING SAME AS ON CONDUCTOR,
EXCEPT TIN-COATED SHIELD WITH SILVER-COATED
HIGH-STRENGTH ALLOY CONDUCTOR
COMPONENT WIRES - 44A011+ JACKET - RADIATION-CROSSLINKED,
MODIFIED PVDF
FILAMENT BINDER AS REQUIRED
TABLE I. CABLE CONSTRUCTION DETAILS
PART NUMBER
1/
CONDUCTOR
SIZE
(AWG)
SHIELD
SIZE
(AWG)
JACKET THICKNESS
(inch) OUTSIDE DIAMETER
(inch) MAXIMUM
WEIGHT
(lbs/1000 ft.)
MINIMUM MAXIMUM NOMINAL MAXIMUM
44AM115+-26-* 26 38 .005 .010 .125 .142 15.0
44AM115+-24-* 24 38 .005 .010 .141 .161 19.8
44AM115+-22-* 22 38 .005 .010 .160 .183 26.0
44AM115+-20-* 20 38 .006 .012 .184 .210 35.8
44AM115+-18-* 18 38 .006 .012 .211 .242 50.1
44AM115+-16-* 16 38 .007 .014 .231 .266 61.9
44AM115+-14-* 14 38 .007 .014 .277 .319 91.0
44AM115+-12-* 12 36 .007 .014 .333 .383 139.
TABLE II. CABLE PERFORMANCE DETAILS
PART NUMBER
1/
BEND TESTING
MANDREL DIAMETER
(inch) (± 3%) WEIGHT
(lb) (± 3%)
IMMERSION AND
CROSSLINKED VERIFICATION COLD
BEND IMMERSION AND
CROSSLINKED VERIFICATION COLD
BEND
44AM115+-26-* 3.00 3.00 .625 3.75
44AM115+-24-* 6.00 6.00 .938 3.75
44AM115+-22-* 6.00 6.00 .938 7.50
44AM115+-20-* 6.00 6.00 .938 7.50
44AM115+-18-* 6.00 6.00 1.25 7.50
44AM115+-16-* 6.00 6.00 1.25 7.50
44AM115+-14-* 10.0 10.0 2.50 22.5
44AM115+-12-* 10.0 10.0 2.50 22.5
Nominal values are for information only. Nominal values are not requirements.
Page 1 of 2
SPECIFICATION CONTROL DRAWING Page
2 of 2
Revision
G
SCD
44AM115+
CABLE RATINGS AND ADDITIONAL REQUIREME NTS
TEMPERATURE RATING: 150°C
Maximum continuous conductor tempe rature
VOLTAGE RATING: 600 volts (rms) at sea level
BLOCKING: 150 ± 3°C for 6 hours
CROSSLINKED VERIFICATION: 200 ± 5°C for 6 hours
DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz,
15 seconds (minimum), 30 seconds (maximum)
FLAMMABILITY: 30 seconds (maximum), 3 inches (maximum); no flaming of facial tissu e
IMMERSION: Diameter increase 5% (maximum); no cracking, no dielectric breakdown
JACKET COLOR: White preferred
JACKET CONCENTRICITY: 70% (minimum)
JACKET ELONGATION AND TENSILE STRENGTH:
Elongation, 200% (minimum)
Tensile Strength, 4000 lbf/in2 (minimum)
JACKET FLAWS:
Spark Test, 1.5 kV (rms)
Impulse Dielectric Test, 6.0 kV (peak)
LOW TEMPERATURE-COLD BEND: -55 ± 5°C for 4 hours
SHIELD COVERAGE: 85% (minimum)
VOLTAGE WITHSTAND (Post Environmental): 1000 volts (rms), 60 Hz, 1 minute
1/ PART NUMBER:
The "+" in the part numbers in Tables I and II shall be replaced with a conducto r material
designator as follows:
1 tin-coated copper
2 silver-coated copper
3 nickel-coated copper
4 silver-coated high-strength copper alloy (AWG 26-16 only)
6 nickel-coated high-strength copp er alloy (AWG 26-20 only)
The "*" in the part numbers in Tables I and II shall be replaced by color code designators with a
slash separating the com ponent wire colors and a dash separating the component wire colors
from the jacket color. Colors shown do not necessarily reflect the sequen ce of manufacturing.
Example: AWG 20, tin-coated copper conductors; red, orange, green, blue, and white
component wires; white jacket: 44AM1151-20-2/3/5/6/9-9
1 See footer section on page 1