Application Specification
114-1020
LOC B
1
of 5
E
2008 Tyco Electronics Corporation, Harrisburg, PA
All International Rights Reserved
TE logo and Tyco Electronics are trademarks.
*Trademark. Other products, logos, and company names used are the property of their respective owners.
TOOLING ASSISTANCE CENTER 1-800-722-1111
PRODUCT INFORMATION 1-800-522-6752 This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at
www.tycoelectronics.com
MTA 156 Connector
20 NOV 08 Rev H
All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and
inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2
_
.
Figures and illustrations are for identification only and are not drawn to scale.
1. INTRODUCTION
This specification covers the requirements for application of wire to MTA (Mass Termination Assembly) 156
Connectors. These requirements are applicable to hand or automatic machine application tools.
Specific wire and insulation ranges relative to the products covered in this specification are 26–18 AWG tin
plated solid, concentric fused stranded, and concentric stranded wire with standard PVC thermoplastic
insulation having a maximum insulation outside diameter of 2.41 mm [.095 in.] when terminated one position at
a time, or 1.78 mm [.070 in.] when mass terminating. Stranded wire configurations approved by Tyco
Electronics are 18 AWG 7, 16, and 19 stranded; 20 AWG 7, 10, and 19 stranded; 22–24 AWG 7, 10, and 19
stranded; and 26 AWG 7 stranded. Underwriters Laboratories (UL) Inc. UL1061 is the preferred wire for mass
termination use with UL1007 also being initially approved for single termination with all wire AWG.
Other wires evaluated and approved by Tyco Electronics are provided in the table in Figure 1. Wires approved
are specifically shown by UL wire style and wire AWG tested. Only wire AWGs specifically shown in the table
in Figure 2 for each UL style are approved by Tyco Electronics. Other wires should be submitted for formal
evaluation by Tyco Electronics prior to use to verify proper product function. For specific connector assembly
part numbers and wire sizes, contact the Product Information number at the bottom of this page.
When corresponding with Tyco Electronics Personnel, use the terminology provided in this specification to help
facilitate your inquiry for information. Basic terms and features of components are provided in Figure 1.
Figure 1 (cont’d)
Strain Relief
Contact
Housing
Wire
Section A-A
AA
NOTE
i
114-1020
MTA 156 Connector
Rev
H2
of 5 Tyco Electronics Corporation
MTA 156 CONNECTORS
WALL APPROVED WIRE (AWG)
MTA 156 CONNECTORS
mm [in.] 18 20 22 24 26
UL 1007 PVC Insulation 0.38 [.015]
nnnnn
UL 1061 Semi-Rigid PVC Insulation 0.23 [.009]
nnnnn
UL 1180 TEFLON
D
Insulation - T.F.E. 0.38 [.015]
n
UL 1213 TEFLON Insulation - T.F.E. 0.25 [.010]
n n n
UL 1316 PVC/Nylon Wall 0.38 [.015]
n n
UL 1429 Irradiated PVC - X.L.P.V.C. 0.25 [.010]
n n n n
UL 1430 Irradiated PVC - X.L.P.V.C. 0.38 [.015]
n n n n
UL 1569 PVC 0.38 [.015]
n
UL 3265 Irradiated Polyethylene - X.L.P.E. 0.25 [.010]
n
UL 3266 Irradiated Polyethylene - X.L.P.E. 0.38 [.015]
n n n n
NOTE:
When selecting approved wire styles noted in this list, the MTA Application Specifications guidelines must be followed. Also, due to
wire variations in insulation wall thickness, hardness, and wire stranding, we would recommend evaluating the wire selected before
final application approval.
Figure 1 (end)
2. REFERENCE MATERIAL
2.1. Revision Summary
S
Updated document to corporate requirements and new format
S
Changed text in Section 1, INTRODUCTION
S
Added new table to Figure 1
S
Added new Section 2, REFERENCE MATERIAL and Section 4, QUALIFICATIONS
S
Added new Figure 5
2.2. Customer Assistance
Reference Part Numbers 640426 (Product Code 1524 for Standard); 644329 (Product Code 1521 for Quad);
and 640859 (Product Code 1533 for Card Edge) are representative numbers of MTA 156 Connectors. Use of
these numbers will identify the product line and expedite your inquiries through a service network established
to help you obtain product and tooling information. Such information can be obtained through a local Tyco
Electronics Representative or, after purchase, by calling the Product Information Center at the number at the
bottom of this page.
2.3. Drawings
Customer Drawings for specific products are available from the service network. The information contained in
Customer Drawings takes priority if there is a conflict with this specification or with any technical
documentation supplied by Tyco Electronics.
2.4. Specifications
Product Specifications 108–1051 (Wire–to–Post), 108–1058 (Card Edge), and 108–1065 (Wire–to–Wire)
provides product performance requirements and test information.
2.5. Instructional Material
The following list includes available instruction sheets (408–series) that provide assembly procedures for
operation, maintenance and repair of tooling; and customer manuals (409–series) that provide setup,
operation, and maintenance of machines.
Document Number Document Title
408–4146 Terminating Head 58247–3 for MTA–156 Receptacle Connectors
408–4260 Mass Termination Assembly (MTA) Applicator Assemblies 58575–1 and 58576–1
408–4405 Mass Insertion Terminating Head 58646–1
408–4439 Ribbon Cable Mass Insertion Tooling Head 58646–2
D
T rademark of E.I. DuPont de Nemours and Company
114-1020
MTA 156 Connector
Rev
H 3
of 5
Tyco Electronics Corporation
Document Number Document Title
408–6701 Mass Termination Assemblies (MTA) 156 Tooling Assembly 58040–1
408–6789 Pistol Grip Pneumatic Handle Assembly 58075–1
408–6790 Pistol Grip Manual Handle Assembly 58074–1
408–6794 Terminating Head 58061–1 for MTA–156 Card Edge Connectors Using Discrete Wire
408–6795 MTA Terminating Head 58082–1
408–6923 Manual Arbor Frame Assembly 58024–1
408–6930 Terminating Head 58247–1 for MTA–156 Receptacle Connectors Using Discrete Wire
408–7907 Insertion Tools 59803–1 and 59804–1 for MTA Connectors
408–7995 Mass Termination Assembly (MTA) .156 Connector–Holding Fixture
408–8054 Insulation Displacement Applicator for MTA Connectors (466727–1)
408–8069 Insulation Displacement Applicator for MTA Card Edge Connectors (567020–1)
408–9380 MTA Terminating Head 58247–2 (Extended–Wear Type)
408–9393 Pneumatic Power Bench Assembly 58338–1
408–9466 Feed Track Assembly 933568–1 for MTA–.156 Closed–End Receptacle Connectors
408–9636 Feed Track Assembly 853546–1 and Base Assembly 853542–1
408–9637 Feed Track Assembly 853547–1 and Base Assembly 853542–1
408–9650 Die Set Assembly 854176–1 and Base Assembly 854200–1
408–9667 Die Set Assembly 854175–1 and Base Assembly 854200–1
409–5746 Electric Power Unit 931800–1
409–5590 2700–lb. Pneumatic Power Unit 312522–[ ]
3. REQUIREMENTS
3.1. Wire Termination
After termination, wire shall meet the requirements specified in Figure 2.
Figure 2
Conductor
Centerline of Conductor
2.41 +0.46/-0.13
[.095 +.018/-.005]
1.52 [.060 Min.]
3.2. Contact Damage
There shall be no evidence of physical damage or distortion to any portion of the contact after wire termination.
3.3. Housing Damage
A. There shall be no cracks, breaks, or other visible damage to the housing due to wire termination.
B. Skiving of plastic on the inside wall of the housing cavity is permissible provided that conditions specified in
Paragraph 3.3.A are met.
3.4. Broken Strands
There shall be no broken strands in the conductor after termination.
114-1020
MTA 156 Connector
Rev
H4
of 5 Tyco Electronics Corporation
3.5. Exposed Conductor
Exposed conductors shall not exceed the limits specified in Figure 3 after termination.
Figure 3
Bare Wires Shall Not
be Visible Beyond
Back of Housing
Back of Housing
Bare Wires Shall
Not Extend Above
Top of Contact
Top of Contact
3.6. Conductor Insulation
Conductor insulation shall be contained within the confines of the insulation strain relief as shown in Figure 4.
Figure 4
Insulation Strain Relief
Conductor Insulation
4. QUALIFICATIONS
MTA 156 Connectors are Recognized by Underwriters Laboratories Inc. (UL) in File No. E28476 and are
Certified by CSA International in File No. LR7189.
114-1020
MTA 156 Connector
Rev
H 5
of 5
Tyco Electronics Corporation
5. TOOLING
Figure 5 provides tooling information for termination of MTA 156 Connectors. Related documentation may be
found in Paragraph 2.5, Instructional Material.
ONE-AT-A-TIME TERMINATION TOOLING PART NUMBERS
INTERCHANGEABLE
HEAD
INTERCHANGEABLE
HEAD AND LOOSE
PIECE FEED TRACK
INTERCHANGEABLE
HEAD AND TAPE
FEED TRACK
MTA CONNECTOR
ASSEMBLY
Manual Hand Tool
58074-1
Air Hand Tool 58075-1
Air Bench Mount Tool
58338-1
Electric Bench
Machine 931800-1
Air Bench Mount Tool 58338-1
Electric Bench Machine 931800-1
SPECIAL
APPLICATOR T-HANDLE
TOOL
58247-1 (Standard)
853547 1
Closed End 58247-2 (Ext Wear) 933568-1
853547
-
1
853542
-
1 (Base)
466727-1
MTA-156
Co ecto
58247-3 (Ribbon Cable)
853542 1 (Base)
59804
-
1
C
onnec
t
or Feed-Thru 58443-1
59804 1
Posted
(Closed End) 58082-1 --- --- ---
MTA-156
Card-Edge Closed End 58061-1 --- --- 567020-1 ---
MTA-156
Quad Closed End 58392-1 --- --- --- 59804-1
MTA-156 MASS TERMINATION TOOLING PART NUMBERS
MTA CONNECTOR
ASSEMBLY
INTERCHANGEABLE HEAD HARNESS BOARD
HOLDING FIXTURE INTERCHANGEABLE HEAD
AND TAPE FEED TRACK
ASSEMBLY
PART NO. USED WITH PART NO. APPLICATOR TOOLING PART NO. USED WITH
Closed End
---
---
58244-1 --- 854176-1
854200-1
312522-1
Closed End
--- --- 58244-3 58576-1
854200
-
1
(Base)
312522
-
1
Feed-Thru
58646-1
(Discrete
Wire) 58074-1
(Manual Hand
58245-1 ---
MTA-156
Connector
Feed
-
Thru
)
58646-2
(Notched
Cable)
(Manual Hand
Tool) 58245-3 58576-1
Card Edge
---
---
59848-1 --- Manual Bench
Tool 58024 1
Card Edge
--- --- 59848-3 58576-1
Tool 58024
-
1
and Toolin
g
Closed End
---
---
58009-1 ---
g
Assy 58040-1 --- ---
(Posted) --- --- 58009-2 58576-1
Feed Thru
(Posted) --- --- 58010-2 58576-1
Closed End
---
---
58244-1 ---
MTA-156
Closed End
--- --- 58244-3 58576-1
Quad
Feed Thru
---
---
58245-1 ---
Feed Thru
--- --- 58245-3 58576-1
Figure 5