Maintain power systems, troubleshoot power
problems, diagnose equipment failures
The Fluke 43B Power Quality Analyzer performs
the measurements you need to maintain power
systems, troubleshoot power problems and
diagnose equipment failures. All in a rugged
handheld package.
New! NiMH Battery provides extended
operating time of 6.5 hours
Combines the most useful capabilities of a
power quality analyzer, multimeter and scope
Calculates 3-phase power on balanced loads,
from a single-phase measurement
Trends voltage, current, frequency, power
harmonics and captures voltage sags,
transients and inrush current
Monitoring functions help track intermittent
problems and power system performance
Records two selectable parameters for up
to 16 days
20 measurement memories to save/recall
screens and data with cursor readings
FlukeView®Software can log harmonics
and all other readings over time and provides
a complete harmonics profile up to the
51st harmonic
Measures resistance, diode voltage drop,
continuity, and capacitance
Users/applications manual and power quality
video to help answer tough questions
Complete package with voltage probes and
400 A current clamp, FlukeView Software and
optically isolated interface cable
3 year warranty on the Fluke 43B, 1 year on
accessories
On screen graphics show you how to set up
3-phase power measurements
Watts, power factor, displacement power
factor (Cos φ), VA and VAR
Voltage and current waveforms
Voltage, current, and power harmonics
Up to 51st harmonic
Total harmonic distortion (THD)
Phase angle of individual harmonics
Voltage and current waveforms
True-rms voltage and current
Frequency
Fluke 43B Power Quality Analyzer
Input Characteristics Ranges Accuracy
Input impedance 1 M, 20 pF
Voltage rating 600 Vrms, CAT III
Volt/Amps/Hertz
True-rms voltage (AC+DC) 5.000 V, 50.00 V, 500.0 V, 1250 V* ± (1 % + 10 counts)
True-rms current (AC+DC) 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA ± (1 % + 10 counts)
Frequency 10.0 Hz to 15.0 kHz ± (0.5 % + 2 counts)
CF Crest Factor 1.0 to 10.0 ± (5 % + 1 count)
Power
W, VA, VAR Reactive Power 250 W 2.50 kW, 25.0 kW, 250kW, 2.50 MW, ± (2 % + 6 counts) Total Power
1-phase and 3-phase, 3 25 MW, 250 MW, 625 MW, 1.56 GW ± (4 % + 4 counts) Fundamental
conductor balanced loads Power
PF Power Factor 0.00 to 1.00 ± 0.04
DPF Displacement Power Factor 0.00 to 0.25 not specified
0.25 to 0.90 ± 0.04
0.90 to 1.00 ± 0.03
Hz Frequency fundamental 40.0 to 70.0 Hz ± (0.5 % + 2 counts)
Harmonics
Volts, Amps, Watts Fundamental V, A ± (3 % + 2 counts),
W ± (5 % + 2 counts)
2 to 31st Harmonic V, A ± (5 % + 3 counts),
W ± (10 % + 10 counts)
32 to 51st Harmonic V, A ± (15 % + 5 counts),
W ± (30 % + 5 counts)
Frequency of fundamental 40 Hz to 70 Hz ± 0.25 Hz
Phase Volt & Amps (between Fund. & Harmonic) 2nd (± 3°) … 51st (± 15°)
Watts (between Volt Fund. & Amps
Harmonic ) Fund (± 5°) … 51st (± 15°)
K-Factor (Amps & Watts) 1.0 to 30.0 ± 10 %
THD 0.00 to 99.99 ± (3% + 8 counts)
Sags & Swells
Recording times (selectable) 4 min to 16 days
Vrms actual, Vrms max, 5.000 V, 50.00 V 500.0 V, 1250 V* Readings ± (2 % +10 counts)
min (AC + DC) Cursor readings ± (2 % + 12 counts)
Cursor Readings Average ± (2 %
+10 counts)
Arms actual, Arms max, 50.00 A, 500.0 A, 5.000 kA, 50,00 kA
min (AC + DC)
Recording
Recording times (selectable) 4 min to 16 days
Parameters Choose one or two parameters from one of the groups below
V/A/Hz Line Voltage, Current, Frequency
Power Watts, VA, VAR, PF, DPF, Frequency
Harmonics THD, Volts (Fund. & Harmonic), Amps(F&H) Watts(F&H) Freq.(H), %(H) of total, Phase(H), KF
Ohms Ohms, Diode, Continuity, Capacitance
Temperature °C or °F
Scope DC Voltage, DC Current, AC Voltage, AC Current, Frequency, Pulse Width + or -,
Phase, Duty cycle + or -, Peak max, Peak min, Peak min-max, Crest Factor
Transients
Minimum pulse width 40 ns
Useful bandwidth input DC to 1 MHz (with test leads TL24)
Number of transients 40
Voltage threshold settings 20 %, 50 %, 100 %, 200 % above or below reference signal
Reference signal After START, the Vrms and frequency of the signal are measured. From these
data a pure sinewave is calculated as reference for threshold setting.
Vpeak min, Vpeak max at cursor 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V ± 5 % of full scale
*Rated 600 V CAT II
Specifications
Accuracies are stated as ± (percentage of
reading + counts) without probes unless
otherwise noted.
Specifications are valid for signals with a
fundamental between 40 and 70 Hz.
• Measurements are always automatically
recorded to instantly show changes over time
• Use cursors to read time and date of sags
and swells
• Catch voltage transients and waveform
distortion down to 40 nS
• Catch and save up to 40 transients
• Correlate the cause of transients with time
and date stamps
Inrush Current Ranges Accuracy
Current ranges (selectable) 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A
Inrush times (selectable) l s, 5 s, 10 s, 50 s, 100 s, 5 min
Cursor readings A peak max at cursor 1 and cursor 2 ± 5 % of full scale
Time between cursors** 4 to 235 pixels ± (0.2 % + 2 pixels)
Scope, dual channel scope with measurement reading
Input impedance
Input 1 1 M/12 pF; with BB120: 20 pF ± 2 pF; with BB120 ± 3 pF
Input 2 1 M/10 pF; with BB120: 18 pF ± 2 pF; with BB120 ± 3 pF
Vertical
Voltage ranges 50 mV/div to 500V/div ± (1% + 2 pixels)
Vertical sensitivity, resolution 5 mV/div to 500V/div, 8 bit (256 levels)
Bandwidth input 1 (voltage) DC to 20 MHz at inputs, or with VPS40 probe (Opt);
1 MHz with TL24 Leads
Bandwidth input 2 (current) DC to 15 kHz at inputs
10 kHz with 80i-500s Current Clamp
Coupling DC, AC (10Hz (-3 dB)
Horizontal
TimeBase modes Normal, roll, single
TimeBase ranges 60 s/div to 20 ns/div ±(0.4 % + 1 pixel)
Sampling rate 25 MS/s
Record length 512 per channel
(min / max samples)
Trigger source Input 1 or Input 2 or Automatic selection
Trigger mode Automatic Connect-and-View™, Free Run,
Single Shot.
Connect-and-View™ Advanced automatic triggering that recognizes signal patterns and automatically
adjusts triggering, timebase and amplitude. Automatically displays stable pictures
of complex and dynamic signals like motor drive and control signals.
Pre-trigger Up to 10 divisions
Measurement readings, Volts & Amps (DC, AC, AC + DCrms, Peak max, Peak min, Peak min / max ),
per channel selectable Frequency, Duty cycle + or - , Phase, Pulse Width + or -, Crest factor
Ohms, Diode, Continuity, Capacitance
Ohms 500.0 5.000 k, 50.00 k, 500.0 k, ± (0.6 % +5 counts)
5.000 M, 30.00 M
Diode voltage 0 to 3.000 V ± (2 % +5 counts)
Continuity, shorts > 1 ms Beeper on at < 30 ±5 ,
Capacitance 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, ±(2 % +10 counts)
500.0 µF
Temperature*** -100.0 °C to 400.0 °C, ±(0.5 % +5 counts)
-200.0 °F to 800.0 °F
Max current, max open circuit volt. 0.5 mA, < 4 V (all functions above)
Memory
Number of screens 20
Optical Isolated Interface
To printer Supports HP LaserJet™, DeskJet, Epson FX/LQ and Postscript printers with
optional PAC91 Printer Adapter Cable
To PC FlukeView®Power Quality Analyzer software with PM9080 Interface
Adapter included
FlukeView®Power Quality Software
Hardware requirements PC or 100 % compatible with Windows®95, 98, Me, 2000, NT4.0.
** 1 pixel = inrush time/250
*** Requires optional temperature accessory
• Inrush current up to 500A with supplied
current probe
• Use cursors to measure inrush current timing
• Connect-and-View™ scope for quick
waveform display
20MHz bandwidth with optional 10:1 voltage
probe. 15kHz on current channel with
optional current clamp
FlukeView®Power Quality Analyzer software
(included)
• Capture measurement screens for
professional-looking reports
• Log readings to your computer disk drive
• Works with Windows word processing,
spreadsheet and analysis software
• Windows 95 / 98 / Me / 2000 / NT 4.0
Ordering Information
Fluke 43B Power Quality Analyzer
Included Accessories
C120 Hard Case
TL24 Test Leads
AC20 Industrial Test Clips
AC85 Large Jaw Alligator Clips
TP1 Flat-tipped Slim-Reach™ Test
Probes
TP4 4 mm Round Slim-Reach™
Test Probes
i400s 400 A AC Current Clamp
OC4USBOptically Isolated USB
Interface Adapter
BP120MH Rechargeable NiMH Battery
Pack (installed)
PM8907 Line Voltage Adapter/Battery
Charger
SW43W FlukeView®Power Quality
Analyzer Software for
Windows
Power Quality CD with:
User’s manual
Power quality video
Application guide
Getting started guide
Shielded Banana-to-BNC adapter
Optional Accessories
C789 Soft Carrying Case
80i-110s 100A AC/DC Current Probe
i200s AC Current Clamp
i1000s 1000A AC Current Clamp
i2000flex Flexible 2000A AC Current
Probe
i3000s Clamp-On AC Current Clamp
VPS40 10:1 Voltage Probe
BB120 Two Shielded Banana-to-
BNC Adapters
80TK Thermocouple Module
80T-150U Universal Temperature Probe
PAC91 Parallel Printer Adapter
TLK225 SureGrip®Master Accessory
Test Lead Kit
TL220 63" Test Lead Set
TL221 Extension Lead Set
TL223 Electrical Test Lead Set
Power
Line voltage adapter/battery charger included
Installed battery Rechargeable NiMH pack (4.8v dc)
Operating time 4 hours
Charging time 7 hours
Environmental
Temperature 0 ºC to 50 ºC (32 ºF to 122 ºF)
Environmental MIL 28800E, Type 3, Class III, Style B
Enclosure IP51 (dust, drip water proof)
Mechanical Data
Size (H x W x D) 232 x 115 x 50 mm (9.1 x 4.5 x 2 inches)
Weight 1.1 kg (2.5 lbs.) incl. battery pack
Safety
For measurements on 600 Vrms Category III installations, Pollution Degree 2 in accordance with
E N 61010-1
ANSI/ISA S82.01-1994
CAN/CSA-C22.2 No. 61010.1-04
Surge protection 6 kV on input 1 and 2
Floating measurements 600 Vrms from any terminal to ground
Warranty 3 years parts and labor on Fluke 43B, 1 year on accessories
General Specifications
43B POWER QUALITY ANALYZER
HOLD
RUN
PRINT
ENTER
F1 F2 F3
RECORD
MENU
SAVE
12
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-51
16
In Europe/M-East/Africa (31 40) 2 675 200 or
Fax (31 40) 2 675 222
In Canada (800) 36-FLUKE or
Fax (905) 890-6866
From other countries (425) 446-5500 or
Fax (425) 446-5116
Web access: http://www.fluke.com/
©2005 Fluke Corporation. All rights reserved.
Trademarks are the property of their respective owners.
Printed in U.S.A. 11/2005 1266142 D-ENG-N Rev H
Printed on recycled paper.
Fluke. Keeping your world