I/O module-AXL F AI4 I 1H-2688491
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
AxiolineF, Analog input module, Analog inputs: 4, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection
method: 2, 3, 4-wire, transmission speed in the local bus: 100 Mbps, integrated sensor supply, degree of
protection: IP20, including bus base module and AxiolineF connectors
Product Description
The module is designed for use within an AxiolineF station.
It is used to acquire analog current signals.
Your advantages
4 analog, bipolar input channels for the connection of current signals
Connection of sensors in 2, 3, and 4-wire technology
Current ranges: 0mA ... 20mA, 4mA ... 20mA, ±20mA
Simultaneous scanning of all channels by means of simultaneous sampling
High crosstalk attenuation between the channels, thanks to separate signal paths
Particularly robust against electromagnetic interference
Device rating plate stored
Key Commercial Data
Packing unit 1 pc
GTIN
GTIN 4046356744225
Weight per Piece (excluding packing) 200.000 g
Custom tariff number 85389091
Country of origin Germany
Technical data
Dimensions
https://www.phoenixcontact.com/us/products/2688491
01/25/2020Page2/14
I/O module-AXL F AI4 I 1H-2688491
Technical data
Dimensions
Width 35 mm
Height 126.1 mm
Depth 54 mm
Note on dimensions The depth is valid when a TH35-7,5 DIN rail is used (according to
EN60715).
Ambient conditions
Ambient temperature (operation) -25 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000m above sea level)
Degree of protection IP20
Connection data
Designation AxiolineF connector
Connection method Push-in connection
Note on the connection method Please observe the information provided on conductor cross sections in
the “AxiolineF: system and installation” user manual.
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 1.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 16
Stripping length 8 mm
General
Mounting type DIN rail
Color traffic grey A RAL 7042
Net weight 195.9 g
Note on weight specifications with connectors and bus base module
Mounting position any (no temperature derating)
Interfaces
Designation AxiolineFlocal bus
No. of channels 2
Connection method Bus base module
Transmission speed 100 Mbps
https://www.phoenixcontact.com/us/products/2688491
01/25/2020Page3/14
I/O module-AXL F AI4 I 1H-2688491
Technical data
Axioline potentials
Designation AxiolineF local bus supply (UBus)
Supply voltage 5 VDC (via bus base module)
Current consumption typ. 120 mA
max. 150 mA
Designation Supply for analog modules (UA)
Supply voltage 24 VDC (I/O supply and sensor supply)
Supply voltage range 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current consumption max. 45 mA (IiS = 0 mA)
typ. 118 mA (IiS = 4 x 20 mA (nominal load))
max. 125 mA (IiS = 4 x 20 mA (nominal load))
typ. 238 mA (IiS = 4 x 50 mA (full load))
max. 245 mA (IiS = 4 x 50 mA (full load))
Power consumption typ. 1.5 W (at UBus and UA)
max. 1.83 W (at UBus and UA)
Protective circuit Surge protection of the supply voltage electronic (35 V, 0.5 s)
Polarity reversal protection of the supply voltage up to HW02: polarity
protection diodeas of HW03: parallel diode; with external 5A fuse (for
startup only)
Transient protection supply voltage Suppressor diode
Analog inputs
Description of the input Differential inputs, current
Input name Analog inputs
Number of inputs 4
Connection method Push-in connection
Connection technology 2, 3, 4-wire
Note regarding the connection technology shielded
A/D conversion time 31.25 µs
A/D converter resolution 16 bit
Limit frequency (3 dB) 30 Hz
12 kHz
Type of protection Transient protection of inputs
Overload protection of the inputs
Data formats IB IL, S7-compatible
Measured value representation 16 bits (15 bits + sign bit)
Current input signal 0 mA ... 20 mA
4 mA ... 20 mA
-20 mA ... 20 mA
https://www.phoenixcontact.com/us/products/2688491
01/25/2020Page4/14
I/O module-AXL F AI4 I 1H-2688491
Technical data
Analog inputs
Input resistance current input 104 Ω (typical)
Input filter 30 Hz, 12 kHz and mean-value generation (can be parameterized)
Electrical isolation
Test section 5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1
min.
5 V supply (logic)/analog inputs 500 V AC 50 Hz 1 min.
5 V supply (logic)/functional earth ground 500 V AC 50 Hz 1 min.
24 V supply (I/O)/analog inputs 500 V AC 50 Hz 1 min.
24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.
Analog inputs/functional earth ground 500 V AC 50 Hz 1 min.
Standards and Regulations
Mechanical tests Vibration resistance in acc. with EN60068-2-6/IEC60068-2-6 5g
Shock in acc. with EN60068-2-27/IEC60068-2-27 30g
Continuous shock according to EN60068-2-27/IEC60068-2-27 10g
Protection class III (IEC61140, EN61140, VDE0140-1)
Environmental Product Compliance
REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings
https://www.phoenixcontact.com/us/products/2688491
01/25/2020Page5/14
I/O module-AXL F AI4 I 1H-2688491
Connection diagram
Differential current input with passive 2-wire transmitter (current loop)
https://www.phoenixcontact.com/us/products/2688491
01/25/2020Page6/14
I/O module-AXL F AI4 I 1H-2688491
Connection diagram
Differential current input with passive 2-wire transmitter (current loop)
https://www.phoenixcontact.com/us/products/2688491
01/25/2020Page7/14
I/O module-AXL F AI4 I 1H-2688491
Connection diagram
Passive pressure sensor at a differential current input
https://www.phoenixcontact.com/us/products/2688491
01/25/2020Page8/14
I/O module-AXL F AI4 I 1H-2688491
Connection diagram
Connection for current measurment
https://www.phoenixcontact.com/us/products/2688491
01/25/2020Page9/14
I/O module-AXL F AI4 I 1H-2688491
Block diagram
Internal wiring of the terminal points
https://www.phoenixcontact.com/us/products/2688491
01/25/2020Page10/14
I/O module-AXL F AI4 I 1H-2688491
Dimensional drawing
Classifications
eCl@ss
eCl@ss 4.0 27240400
eCl@ss 4.1 27240400
eCl@ss 5.0 27242200
eCl@ss 5.1 27242600
eCl@ss 6.0 27242600
eCl@ss 7.0 27242601
eCl@ss 8.0 27242601
eCl@ss 9.0 27242601
https://www.phoenixcontact.com/us/products/2688491
01/25/2020Page11/14
I/O module-AXL F AI4 I 1H-2688491
Classifications
ETIM
ETIM 3.0 EC001599
ETIM 4.0 EC001599
ETIM 5.0 EC001596
ETIM 6.0 EC001596
ETIM 7.0 EC001596
UNSPSC
UNSPSC 6.01 43172015
UNSPSC 7.0901 43201404
UNSPSC 11 39121311
UNSPSC 12.01 39121311
UNSPSC 13.2 32151602
UNSPSC 18.0 32151602
UNSPSC 19.0 32151602
UNSPSC 20.0 32151602
UNSPSC 21.0 32151602
Approvals
Approvals
Approvals
DNV GL / PRS / BV / LR / KR / ABS / BSH / RINA / UL Listed / cUL Listed / EAC / cULus Listed
Ex Approvals
Approval details
DNV GL https://approvalfinder.dnvgl.com/ TAA00000DF
PRS http://www.prs.pl/ TE/2239/880590/19
https://www.phoenixcontact.com/us/products/2688491
01/25/2020Page12/14
I/O module-AXL F AI4 I 1H-2688491
Approvals
BV http://www.veristar.com/portal/veristarinfo/generalinfo/
approved/approvedProducts/equipmentAndMaterials 36433/B0 BV
LR http://www.lr.org/en 14-20019
KR http://www.krs.co.kr/eng/main/main.aspx HMB17372-AC002
ABS http://www.eagle.org/eagleExternalPortalWEB/ 18-HG1767360-PDA
BSH http://www.bsh.de/de/index.jsp 840
RINA http://www.rina.org/en ELE256518XG
UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705
cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705
EAC EAC-Zulassung
cULus Listed
Accessories
Accessories
https://www.phoenixcontact.com/us/products/2688491
01/25/2020Page13/14
I/O module-AXL F AI4 I 1H-2688491
Accessories
Device marking
Insert label-EMT (35X28)R-0801602
Insert label, Roll, white, unlabeled, can be labeled with: THERMOMARK ROLLMASTER 300/600, THERMOMARK X1.2,
THERMOMARK ROLL X1, THERMOMARK ROLL 2.0, THERMOMARK ROLL, mounting type: snapped into marker
carrier, lettering field size: 35 x 28 mm, Number of individual labels: 500
DIN rail connector
Bus connector-AXL F BS H-2700992
AxiolineF bus base module for housing type H
Shield connection
Shield connection-AXL SHIELD SET-2700518
Axioline shield connection set (contains 2 shield bus holders and 2 SK 5 shield connection clamps)
Terminal marking
Zack marker strip-ZB 20,3 AXL UNPRINTED-0829579
Zack marker strip for AxiolineF (device labeling), in 2 x 20.3 mm pitch, unprinted, 25-section, for individual labeling with
B-STIFT 0.8, X-PEN, or CMS-P1-PLOTTER
https://www.phoenixcontact.com/us/products/2688491
01/25/2020Page14/14
I/O module-AXL F AI4 I 1H-2688491
Accessories
Zack Marker strip, flat-ZBF 10/5,8 AXL UNPRINTED-0829580
Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type:
snap into flat marker groove, for terminal block width: 10.15 mm, lettering field size: 4 of 10.15 x 5 mm and 1 of 5.8 x 5
mm, Number of individual labels: 50