OSCILLOSCOPES OSCILLOSCOPES 100MHz CURSOR READOUT ANALOG OSCILLOSCOPE The GOS-6100 Series is a 100MHz, two-channel, dual-sweep, portable oscilloscope for general purpose use. A microprocessor-based operating system controls most of the functions of the instrument, in cluding cursor readout and digitized panel setting. On-screen alphanumeric readout and cursor function for voltage, time, frequency and phase measurement provide extraordinary operational convenience. The advance Time Base Auto-rang fun ction conveniently acquires waveforms at the push of button (GOS-6103/ 6103C). Ten different user defined instrument settings (GOS-6103/ 6103C) can be saved and recalled without restriction. GOS-6112/6103/6103C (100 MHz) GOS-6103C Without The vertical deflection system has two input channels. Each channel has 11 basic deflection factors from 2mV to 5V per division. The horizontal deflection system provides single, dual or delayed sweeps from 0.5s to 50ns per division (delayed sweep, 50ms to 50ns per division). The trigger system provides stable triggering over the full bandwidth of the vertical deflection system. GOS-6112 Approval FEATURES * 100MHz Bandwidth, Dual Channel, Delayed Sweep * Built-In 6 digits Universal Counter (GOS-6103C) * 10 Sets Memory for Front Panel Setting Save & Recall (GOS-6103/GOS-6103C) * Time Base Auto-range (GOS-6103/GOS-6103C) * Cursor Readout with 7 Measurements * Panel Setup Lock of Digital-Control Functions * Buzzer Alarm * LED Indicators * TV Synchronization * Trigger Signal Output * Z-Axis Modulation Input * SMD Technology, High Stability and Reliability CURSOR MEASUREMENT FUNCTIONS Accelerating Potential Illumination Z-axis input Sensitivity Sensitivity Accuracy Vernier Vertical Sensitivity Bandwidth(-3dB) Rise Time Signal Delay Max. Input Voltage Input Coupling Input Impedance Vertical Mode Bandwidth Limited Common-Mode Rejection Ratio Dynamic Range readouts make waveform observation and measurement easier, faster and more accurate. TRIGGER The on-screen cursors provide seven Trigger Modes Trigger Source Trigger Coupling Trigger Slope The unique, easy-to-use cursor and numerical measurement functions ( T,T%, V, ) V%, VdB, T, 6-inch rectangular type with internal graticule; 0%, 10%, 90% and 100% markers 8 x 10 div (1 div = 1 cm) 16 kV approx. (GOS-6103/GOS-6103C), 12kV approx. (GOS-6112) Continuously adjustable (GOS-6103/GOS-6103C) Coupling : DC Sensitivity: 5V or more Maximum input voltage : 30V (DC + AC peak) at 1kHz or less Bandwidth : DC ~ 5 MHz VERTICAL SYSTEM HORIZONTAL SYSTEM Horizontal Modes A(main) Sweep Time B(delay) Sweep Time Accuracy Sweep Magnification Hold Off Time Delay Time Delay Jitter Alternate Separation 1/ SPECIFICATIONS SPECIFICATIONS CRT Type Trigger Sensitivity SPECIAL FUNCTION TIME/DIV Auto Range Panel Setting Save & Recall Panel Setups Lock POWER SOURCE NORM TV 10 Hz ~ 20 MHz 20 MHz ~ 100 MHz DC ~ 20 MHz 20 MHz ~ 100 MHz sync signal Max. 6-digits, decimal 50Hz ~ 100MHz _ 0.05% _ 0.01% ; 50Hz ~ 1kHz : + 1kHz ~ 100MHz : + > 2 div (Measuring source selected from CH1 and CH2 as synchronous signal sources) Provided (GOS-6103/GOS-6103C) 10 sets (GOS-6103/GOS-6103C) Provided Voltage Percentage Measurement DIMENSIONS & WEIGHT 310(W) x 150(H) x 455(D) mm ; Approx. 9kg ORDERING INFORMATION GOS-6112 100MHz, 2-channel, Analog Oscilloscope GOS-6103 100MHz, 2-channel, Analog Oscilloscope GOS-6103C 100MHz, 2-channel, Analog Oscilloscope with 100MHz Frequency Counter Frequency Measurement ACCESSORIES : User manual x 1, Power cord x 1 GTP-100A-2 : 100MHz ( 10 : 1/1 :1 ) Switchable Passive Probe (one per channel) OPTIONAL ACCESSORIES GTC-001 Instrument Cart, 450(W) x 430(D) mm (120V Input Socket) GTC-002 Instrument Cart, 330(W) x 430(D) mm (120V Input Socket) GTL-110 Test Lead, BNC-BNC Heads AUTO, NORM,TV CH1,CH2,LINE,EXT AC,DC,HFR,LFR "+" or "-" polarity or TVsync polarity Frequency Voltage Measurement _ WIDTH, + _ DUTY (+ or - polarity selected by trigger slope) FREQ, PERIOD, + _10% , 50/60Hz AC 100V/120V/230V + MAIN(A), ALT, DELAY(B) 50ns~0.5s/div, continuously variable (UNCAL) 50ns~50ms/div + _ 3% ( + _ 5% at x 10 MAG) x 10 (maximum sweep time 5nS/div) Variable 1 s~5s Better than 1:20000 Variable Mode CURSOR READOUT FUNCTION Cursor Measurement Function V, V%, VdB, T, 1/ T, T%, Cursor Resolution 1/100 div _ 4 div _ 3div ; Horizontal: + Effective Cursor Range Vertical: + Panel Setting Display Vertical: V/div(CH1,CH2),UNCAL,ALT/CHOP/ADD,INV, probe factor,AC/DC/GND Horizontal: s/div(MTB, DTB), UNCAL, x 10MAG, delay time , Hold-off Trigger: source, coupling, slope, level, TV-V, TV-H Others: X-Y, lock, save/recall MEM 0-9 (GOS-6103/GOS-6103C) AUTO MEASUREMENT FUNCTION (GOS-6103C) Parameter Function Display Digits Frequency Range Accuracy Measuring Sensitivity 2mV~5V/div, 11 step in 1-2-5 sequence _ 3% (5div at the center of display) < Continuously variable to 1/2.5 or less of panel-indicate value DC~100MHz(2mV/div:DC~20MHz) 3.5ns (2mV/div:17.5ns) Leading edge can be monitored 400V(DC+AC peak) at 1kHz or less AC, DC, GND _2% // approx. 25pF 1M + CH1,CH2,DUAL(CHOP/ALT), ADD, CH2 INV. 20MHz 50:1 or better at 50kHz 8 div at 60MHz; 5div at 100MHz (GOS-6112) 8 div at 100MHz (GOS-6103/GOS-6103C) AUTO Rear Panel GOS-6103/6103C Time Percentage Measurement INT 0.35 div 1.5 div 0.35 div 1.5 div 1 div EXT 50 mV 150 mV 50 mV 150 mV 200 mVpp TV sync Max. External Input Voltage External Input Impedance X-Y OPERATION TV-V, TV-H 400V(DC+AC peak ) at 1kHz _5% // approx.25pF 1M W + Mode Sensitivity Accuracy X-axis Bandwidth Phase Error X-axis: selectable CH1, CH2, EXT ; Y-axis: selectable CH1, CH2, CH1 and CH2 _ 3% ; EXT : 0.1V/div + _ 5% 2mV~5V/div+ DC~500kHz(-3dB) 3 or less from DC~50kHz Time Measurement OUTPUT SIGNAL GOS-6112 Trigger Signal Output Calibrator Output Voltage: approx. 25mV/div into 50 _ 2% 1kHz Square wave, 2Vpp + ; Frequency response : DC ~ 10MHz Phase Measurement A29 Made to Measure. Good Will Instrument Co., Ltd. A30 OSCILLOSCOPES OSCILLOSCOPES 100MHz CURSOR READOUT ANALOG OSCILLOSCOPE The GOS-6100 Series is a 100MHz, two-channel, dual-sweep, portable oscilloscope for general purpose use. A microprocessor-based operating system controls most of the functions of the instrument, in cluding cursor readout and digitized panel setting. On-screen alphanumeric readout and cursor function for voltage, time, frequency and phase measurement provide extraordinary operational convenience. The advance Time Base Auto-rang fun ction conveniently acquires waveforms at the push of button (GOS-6103/ 6103C). Ten different user defined instrument settings (GOS-6103/ 6103C) can be saved and recalled without restriction. GOS-6112/6103/6103C (100 MHz) GOS-6103C Without The vertical deflection system has two input channels. Each channel has 11 basic deflection factors from 2mV to 5V per division. The horizontal deflection system provides single, dual or delayed sweeps from 0.5s to 50ns per division (delayed sweep, 50ms to 50ns per division). The trigger system provides stable triggering over the full bandwidth of the vertical deflection system. GOS-6112 Approval FEATURES * 100MHz Bandwidth, Dual Channel, Delayed Sweep * Built-In 6 digits Universal Counter (GOS-6103C) * 10 Sets Memory for Front Panel Setting Save & Recall (GOS-6103/GOS-6103C) * Time Base Auto-range (GOS-6103/GOS-6103C) * Cursor Readout with 7 Measurements * Panel Setup Lock of Digital-Control Functions * Buzzer Alarm * LED Indicators * TV Synchronization * Trigger Signal Output * Z-Axis Modulation Input * SMD Technology, High Stability and Reliability CURSOR MEASUREMENT FUNCTIONS Accelerating Potential Illumination Z-axis input Sensitivity Sensitivity Accuracy Vernier Vertical Sensitivity Bandwidth(-3dB) Rise Time Signal Delay Max. Input Voltage Input Coupling Input Impedance Vertical Mode Bandwidth Limited Common-Mode Rejection Ratio Dynamic Range readouts make waveform observation and measurement easier, faster and more accurate. TRIGGER The on-screen cursors provide seven Trigger Modes Trigger Source Trigger Coupling Trigger Slope The unique, easy-to-use cursor and numerical measurement functions ( T,T%, V, ) V%, VdB, T, 6-inch rectangular type with internal graticule; 0%, 10%, 90% and 100% markers 8 x 10 div (1 div = 1 cm) 16 kV approx. (GOS-6103/GOS-6103C), 12kV approx. (GOS-6112) Continuously adjustable (GOS-6103/GOS-6103C) Coupling : DC Sensitivity: 5V or more Maximum input voltage : 30V (DC + AC peak) at 1kHz or less Bandwidth : DC ~ 5 MHz VERTICAL SYSTEM HORIZONTAL SYSTEM Horizontal Modes A(main) Sweep Time B(delay) Sweep Time Accuracy Sweep Magnification Hold Off Time Delay Time Delay Jitter Alternate Separation 1/ SPECIFICATIONS SPECIFICATIONS CRT Type Trigger Sensitivity SPECIAL FUNCTION TIME/DIV Auto Range Panel Setting Save & Recall Panel Setups Lock POWER SOURCE NORM TV 10 Hz ~ 20 MHz 20 MHz ~ 100 MHz DC ~ 20 MHz 20 MHz ~ 100 MHz sync signal Max. 6-digits, decimal 50Hz ~ 100MHz _ 0.05% _ 0.01% ; 50Hz ~ 1kHz : + 1kHz ~ 100MHz : + > 2 div (Measuring source selected from CH1 and CH2 as synchronous signal sources) Provided (GOS-6103/GOS-6103C) 10 sets (GOS-6103/GOS-6103C) Provided Voltage Percentage Measurement DIMENSIONS & WEIGHT 310(W) x 150(H) x 455(D) mm ; Approx. 9kg ORDERING INFORMATION GOS-6112 100MHz, 2-channel, Analog Oscilloscope GOS-6103 100MHz, 2-channel, Analog Oscilloscope GOS-6103C 100MHz, 2-channel, Analog Oscilloscope with 100MHz Frequency Counter Frequency Measurement ACCESSORIES : User manual x 1, Power cord x 1 GTP-100A-2 : 100MHz ( 10 : 1/1 :1 ) Switchable Passive Probe (one per channel) OPTIONAL ACCESSORIES GTC-001 Instrument Cart, 450(W) x 430(D) mm (120V Input Socket) GTC-002 Instrument Cart, 330(W) x 430(D) mm (120V Input Socket) GTL-110 Test Lead, BNC-BNC Heads AUTO, NORM,TV CH1,CH2,LINE,EXT AC,DC,HFR,LFR "+" or "-" polarity or TVsync polarity Frequency Voltage Measurement _ WIDTH, + _ DUTY (+ or - polarity selected by trigger slope) FREQ, PERIOD, + _10% , 50/60Hz AC 100V/120V/230V + MAIN(A), ALT, DELAY(B) 50ns~0.5s/div, continuously variable (UNCAL) 50ns~50ms/div + _ 3% ( + _ 5% at x 10 MAG) x 10 (maximum sweep time 5nS/div) Variable 1 s~5s Better than 1:20000 Variable Mode CURSOR READOUT FUNCTION Cursor Measurement Function V, V%, VdB, T, 1/ T, T%, Cursor Resolution 1/100 div _ 4 div _ 3div ; Horizontal: + Effective Cursor Range Vertical: + Panel Setting Display Vertical: V/div(CH1,CH2),UNCAL,ALT/CHOP/ADD,INV, probe factor,AC/DC/GND Horizontal: s/div(MTB, DTB), UNCAL, x 10MAG, delay time , Hold-off Trigger: source, coupling, slope, level, TV-V, TV-H Others: X-Y, lock, save/recall MEM 0-9 (GOS-6103/GOS-6103C) AUTO MEASUREMENT FUNCTION (GOS-6103C) Parameter Function Display Digits Frequency Range Accuracy Measuring Sensitivity 2mV~5V/div, 11 step in 1-2-5 sequence _ 3% (5div at the center of display) < Continuously variable to 1/2.5 or less of panel-indicate value DC~100MHz(2mV/div:DC~20MHz) 3.5ns (2mV/div:17.5ns) Leading edge can be monitored 400V(DC+AC peak) at 1kHz or less AC, DC, GND _2% // approx. 25pF 1M + CH1,CH2,DUAL(CHOP/ALT), ADD, CH2 INV. 20MHz 50:1 or better at 50kHz 8 div at 60MHz; 5div at 100MHz (GOS-6112) 8 div at 100MHz (GOS-6103/GOS-6103C) AUTO Rear Panel GOS-6103/6103C Time Percentage Measurement INT 0.35 div 1.5 div 0.35 div 1.5 div 1 div EXT 50 mV 150 mV 50 mV 150 mV 200 mVpp TV sync Max. External Input Voltage External Input Impedance X-Y OPERATION TV-V, TV-H 400V(DC+AC peak ) at 1kHz _5% // approx.25pF 1M W + Mode Sensitivity Accuracy X-axis Bandwidth Phase Error X-axis: selectable CH1, CH2, EXT ; Y-axis: selectable CH1, CH2, CH1 and CH2 _ 3% ; EXT : 0.1V/div + _ 5% 2mV~5V/div+ DC~500kHz(-3dB) 3 or less from DC~50kHz Time Measurement OUTPUT SIGNAL GOS-6112 Trigger Signal Output Calibrator Output Voltage: approx. 25mV/div into 50 _ 2% 1kHz Square wave, 2Vpp + ; Frequency response : DC ~ 10MHz Phase Measurement A29 Made to Measure. Good Will Instrument Co., Ltd. A30