Digital I/O Module Engineering Information I/O MODULES Our line of pluggable input and output modules provide a low cost, versatile method for interconnecting real world analog and digital signals to data acquisition, monitoring, or control systems. All modules provide an optically isolated barrier between sensitive microprocessor or digital logic circuits and field power devices. In the G5 and OpenLine(R) packages, analog and digital I/O modules are available with the same pin-out. This gives the flexibility of mixing and matching module types on the same mounting rack or base; making them perfect in applications which require interface to a variety of different sensors and loads. The case color of the single point modules identify their function. The industry standard for single point I/O module case colors is: Digital AC Output Module = Black Case Digital DC Output Module = Red Case Digital AC Input Module = Yellow Case Digital DC Input Module = White Case DIGITAL OUTPUT MODULES Digital output modules are used to switch AC and DC loads such as solenoids, motors, or lamps from logic signal levels. Their inputs are directly compatible with TTL or CMOS interface circuitry. AC output modules have zero voltage turn-on of the load to greatly reduce generated EMI and RFI. They are highly immune to electrical transients, and have built-in RC snubber networks for increased capability with inductive loads. DC output modules can operate DC loads over a wide voltage range and have built-in voltage spike protection. DIGITAL INPUT MODULES Digital input modules are used to monitor the status of a load or a sensor (such as a limit switch, pressure switch, or temperature switch). The output of these modules is a logic level signal which corresponds to the status of the device being monitored. A high level output signal indicates the load is off (the switch is open). A low level output signal indicates the load is on (the switch is closed). Input modules are designed to give fast, clean switching by providing filtering and hysteresis. Input and output modules are compatible in that the output of one can drive the input of the other. UL, CSA AND CE APPROVALS As one of the world's leading manufacturers of I/O modules, we strive to assure that our products comply with all of the applicable international standards. In doing so, we believe your products will also be readily accepted and easily certified. All modules shown in this section have been tested to UL Standard 508 and are documented in UL file number E58632. Similarly, they have been tested to CSA Standard 22.2 No. 14-95M and are documented in CSA file LR38763. Additionally, OpenLine(R) modules were tested and passed CSA 22.2 No. 213-M1987 Class I, Div. 2 Groups A, B, C and D. Parts bearing the CE logo indicate conformance with EN50082-2 and EN50081-2 (89/336/EEC EMC directive) as well as EN60950 (61010-1) for the low voltage directive. Contact Grayhill for copies of our Declaration of Conformity or visit out website. Parts bearing the TUV logo indicate that they were the agency which performed the EN60950 evaluation. CONSTRUCTION AND LIFETIME WARRANTY All of our I/O modules are hard potted with thermally conductive epoxy to withstand harsh industrial environments. The modules provide optical isolation, immunity to mechanical shock and vibration, and operate over a wide temperature range. The module cases are a solvent resistant thermoplastic which meets UL94-V-0 rating. The terminal pins are a tinplated copper wire. Component selection and surface mount construction allow low operating junction temperatures for long life. Superior design, rigorous testing, and field data give us the confidence to back our I/O modules with the industry's first lifetime warranty. I/O MODULE WIRING Analog and digital modules can be placed at any I/O location, however, to minimize the possibility of crosstalk and noise pickup it is a good practice to group similar module types together. 14 or 16 gauge wire is typically used to wire the field devices to the I/O rack terminal block. PART NUMBER EXPLANATION: Digital I/O Modules I/O Modules Module Type 70 = Digital Module, Standard Package 70G = Digital Module, G5 Package 70L = Digital Module, OpenLine(R) Package 70M = Digital Module, Mini Package 70M-ODC5A Function OAC = ODC = IAC = IDC = Digital Output AC Digital Output DC Digital Input AC Digital Input DC Suffix AC Inputs: DC Inputs: AC Outputs: DC Outputs: Blank = 120 Vac Blank = 3-32 Vdc G = 35-60 Vac/Vdc L = Inductive loads A = 220 Vac B = Fast Switching D =2.5-28 Vdc S = Dry Contacts Blank = 120 Vac MA = 120 Vac, Manual Override AMA = 240 Vac, Manual Override Blank = 3-60 Vdc Fast MA = 3-60 Vdc, Manual Override NP = 15-32 Vac/10-32 Vdc K = 2.5-16 Vdc A = 220 Vac A-11 = Non-Zero Cross A-5 = Normally Closed A = 4-200 Vdc R = Dry Contact B = 3-60 Vdc, Low Leakage Logic Supply Voltage or Range Digital Modules: Blank = 4.5-28 Vdc (OpenLine(R)) 5 Vdc, 15 Vdc, 24 Vdc = Logic Supply Voltage (Standard, Mini, G5) Analog Modules: 4.75-5.25 Vdc L-3 Grayhill, Inc. * 561 Hillgrove Avenue * LaGrange, Illinois 60525-5997 * USA * Phone: 708-354-1040 * Fax: 708-354-2820 * www.grayhill.com Digital I/O Modules Engineering Information DIMENSIONS: OpenLine(R) Digital Modules Dimensions shown in inches (and millimeters). Tolerances are .010 (0,25) unless indicated otherwise. Module Type I/O Module Pin # 1 2 3 4 5 6 7 8 9 Output Function Output A+ Output AOutput B+ Output BLogic Gnd Vcc Ch. A Input Ch. B Input Module ID Input Function Input A+ Input AInput B+ Input BLogic Gnd Vcc Ch. A Status Ch. B Status Module ID FUSE HOLDERS (OUTPUTS ONLY) GREEN STATUS LEDS DATE CODE .025 (0,635) SQ. .34 (8,64) .51 (12,95) 2.09 (53,09) .19 (4,83) .03 (0,76) .10 (2,54) .22 (5,59) PIN 9 PIN 8 PIN 7 PIN 6 PIN 5 PIN 4 PIN 3 PIN 2 PIN 1 .14 (3,56) 2.49 (63,25) 2.23 (56,64) .38 (9,65) .24 (6,10) 2.70 (68,58) Note: For PC board layout information, request Bulletin #745 DIMENSIONS: G5 Digital Modules Dimensions shown in inches (and millimeters). Tolerances are .010 (0,25) unless indicated otherwise. Input Modules Ouput Modules 1.90 (48,3) 1.90 (48,3) .46 (11,7) .46 (11,7) GREEN STATUS LED I/O Modules GREEN STATUS LED FUSE HOLDER 4-40 X 2-1/2" PHILLIPS HOLDDOWN SCREW INCLUDED WITH EACH MODULE MAXIMUM TORQUE = 5 FT-LB 2.55 (64,8) 2.20 (55,9) 5 4 3 2 1 2.20 (55,9) O .040/.042 (1,02/1,07) .235 (5,97) 4 3 2 .20 (5,1) 1.15 (29,2) 1.35 (34,3) .235 (5,97) .20 (5,1) .40 (10,2) .90 (22,9) 1 O .040/.042 (1,02/1,07) .40 (10,2) .20 (5,1) .15 (3,8) .90 (22,9) 1.15 (29,2) .20 (5,1) .15 (3,8) 1.35 (34,3) 1.55 (39,4) Grayhill, Inc. * 561 Hillgrove Avenue * LaGrange, Illinois 60525-5997 * USA * Phone: 708-354-1040 * Fax: 708-354-2820 * www.grayhill.com L-4 Digital I/O Modules Engineering Information DIMENSIONS: Standard and Miniature Digital Modules Dimensions shown in inches (and millimeters). Tolerances are .010 (0,25) unless indicated otherwise. Standard Module Miniature Module 1.00 (25,4) .60 (15,2) .40 (10,2) 4-40 X 1-1/2" PHILLIPS HOLDDOWN SCREW INCLUDED WITH EACH MODULE MAXIMUM TORQUE = 5 FT-LB 1.70 (43,2) 1.70 (43,2) 1.25 (31,8) 5 4 3 2 O .040/.042 (1,02/1,07) .235 .02 (6,0 0,52) 1 1.00 (25,4) 5 4 3 2 O .040/.042 (1,02/1,07) 1 .20 (5,1) .235 .020 (6,0 0,52) .30 (7,6) .30 (7,6) .30 (7,6) .10 (2,5) .40 (10,2) .90 (22,9) 1.10 (27,9) 1.30 (33,0) .40 (10,2) OUTPUT MODULES HAVE ONLY TERMINALS NUMBER 1-4 .90 (22,9) 1.10 (27,9) 1.30 (33,0) OUTPUT MODULES HAVE ONLY TERMINALS NUMBER 1-4 WIRING DIAGRAM: Digital I/O Modules DIGITAL AC OUTPUT I/O Modules L-5 LOAD 2 1 DIGITAL DC OUTPUT 2 1 DIGITAL AC INPUT 2 1 DIGITAL DC INPUT 2 1 DIGITAL CONTACT CLOSURE 2 LOAD HOT AC SUPPLY NEUTRAL + DC SUPPLY - HOT AC SUPPLY NEUTRAL + DC SUPPLY - 1 Grayhill, Inc. * 561 Hillgrove Avenue * LaGrange, Illinois 60525-5997 * USA * Phone: 708-354-1040 * Fax: 708-354-2820 * www.grayhill.com Digital I/O Module Selection Chart I/O MODULE SIZE Miniature Saves 35% Space Standard Compatible Industry Size G5 Fused Outputs, Integral LED OpenLine (R) Two Channel, Fused Outputs, Integral LED FUNCTION (Check Specifications for Input and Output combinations, Feature or Option availability.) Control Vcc 5 Vdc 15 Vdc 24 Vdc 4.5-28 Vdc Unique Options Random Turn-on Normally Closed Manual Override Inductive Load See pages L-7 to L-8 Load 60 Vdc 200 Vdc Control Vcc 5 Vdc 15 Vdc 24 Vdc 4.5-28 Vdc Unique Options Dry Contacts Manual Override See pages L-9 to L-14 Supply Vcc 5 Vdc 15 Vdc 24 Vdc 4.5-28 Vdc Input Voltage 120 Vac 220 Vac Unique Options High DC Voltage Input See pages L-15 to L-16 Supply Vcc 5 Vdc 15 Vdc 24 Vdc 4.5-28 Vdc Input Voltage 3 to 32 Vdc Unique Options 10 to 32 Vdc/ 15 to 32 Vac 8 KHz Switching 35 to 60 Vac/Vdc Contact Closure See pages L-17 to L-21 Digital DC Output Digital AC Input Digital DC Input Module Calibrator/Programmer Test Digital I/O Modules The field programmer can be used to test, calibrate and transfer data to smart OpenLine(R) modules. On-board switches also allow testing of digital I/O modules. The programmer connects to a PC through an RS-232 serial port. Software is included to communicate with smart I/O modules. ORDERING INFORMATION Part Number Description Programmer/Calibrator 70L-PROG Field programmer/calibrator for OpenLine(R) I/O Grayhill, Inc. * 561 Hillgrove Avenue * LaGrange, Illinois 60525-5997 * USA * Phone: 708-354-1040 * Fax: 708-354-2820 * www.grayhill.com L-6 I/O Modules Load 120 Vac 220 Vac Digital AC Output