Compact Photoelectric Sensor with Built-in Amplifier E3Z CSM_E3Z_DS_E_14_1 The Standard for Photoelectric Sensors with a Secure Track Record of One Million Sold Yearly. * Long sensing distance of 30 m for Through-beam Models, 4 m for Retro-reflective Models, and 1 m for Diffuse-reflective Models. * Mechanical axis and optical axis offset of less than 2.5 simplifies optical axis adjustment. * High stability with unique algorithm that prevents interference of external light. Be sure to read Safety Precautions on page 15. Features Industry's Top-level Sensing Distance with Built-in Amplifier A separately sold filter is available to prevent mutual interference for Through-beam Models with red lights sources and a sensing distance of 10 m. Reflective Models include functionality to prevent mutual interference. Long-distance, Through-beam Sensors with a detection distance of 30 m (response time: 2 ms) are also available. Through-beam 30 m Retro-reflective with MSR function Distance-settable 20 cm 4m Diffuse-reflective 1m Low-temperature Operation for Applications in Cold-storage Warehouses A wider ambient operating range from -40 to 55C (main models with connectors). We also provide Sensor I/O Connectors with PUR Cables for high resistance to cold environments. Improved Matching of Optical Axis and Mechanical Axis for Through-beam Models and Retro-reflective Models 30 m mechanical 2.5 max. axis The offset between the optical axis and the mechanical axis is kept within 2.5, so the optical axis can be accurately set simply by mounting the Sensor according to the mechanical axis. Sensor Protection against Incorrect Wiring Optical axis The receiver will always be in the range of light diffusion. Through-beam Model receivers and Reflective Models (except the E3Z-LS) The Sensor includes output reverse polarity protection. (A diode to protect against reverse polarity is added to the output line.) Operation indicator (orange) 1 Stability indicator (green) Photoelectric Sensor main circuit 4 ZD 3 Brown Black 12 to 24 VDC 100 mA Load (relay) max. Blue 0V Protection for NPN output models Complete Compliance with the EU's RoHS Directive Lead, mercury, cadmium hexachrome, polybrominated biphenyl (PBB), and polybrominated diphenyl ether (PBDE) have all been eliminated. Also, burnable polyethylene packaging has been used. Pb eco 1 E3Z Ordering Information Sensors [Refer to Dimensions on page 16.] Sensing method Appearance Connection method Red light Sensing distance Standard M8 connector E3Z-T66 Emitter E3Z-T66-L Receiver E3Z-T66-D E3Z-T86 Emitter E3Z-T86-L Receiver E3Z-T86-D Pre-wired (2 m) E3Z-T61A 2M Emitter E3Z-T61-A-L 2M Receiver E3Z-T61-A-D 2M E3Z-T81A 2M Emitter E3Z-T81-A-L 2M Receiver E3Z-T81-A-D 2M Standard M8 connector E3Z-T66A Emitter E3Z-T66-A-L Receiver E3Z-T66-A-D E3Z-T86A Emitter E3Z-T86-A-L Receiver E3Z-T86-A-D Pre-wired (2 m) E3Z-T62 2M Emitter E3Z-T62-L 2M Receiver E3Z-T62-D 2M E3Z-T82 2M Emitter E3Z-T82-L 2M Receiver E3Z-T82-D 2M Standard M8 connector E3Z-T67 Emitter E3Z-T67-L Receiver E3Z-T67-D E3Z-T87 Emitter E3Z-T87-L Receiver E3Z-T87-D 10 m 30m Pre-wired (2 m) E3Z-T62-G0 2M *4 E3Z-T82-G0 2M *4 Emitter E3Z-T62-G0-L 2M Emitter E3Z-T82-G0-L 2M Receiver E3Z-T62-G0-D 2M Receiver E3Z-T82-G0-D 2M Standard M8 connector E3Z-T67-G0 *4 Emitter E3Z-T67-G0-L Receiver E3Z-T67-G0-D Emission stop function Pre-wired (2 m) *1 Standard M8 connector Pre-wired (2 m) Standard M8 connector Standard M8 connector Pre-wired (2 m) Standard M8 connector Pre-wired (2 m) Distance-settable Refer to E3Z-LS. Standard M8 Connector Pre-wired (2 m) Standard M8 connector 1 axis Slit-type Throughbeam Refer to E3Z-G. 2 axes 1 axis 2 axes E3Z-R61 2M E3Z-R81 2M E3Z-R66 E3Z-R86 5 to 100 mm (wide view) 1m 9030 mm (narrow beam) 20 to 40 mm (BGS min setting) 20 to 200 mm (BGS max setting) 40 min. Incident threshold (FGS min setting) 200 min. Incident threshold (FGS max setting) Pre-wired M8 connector Standard M8 connector *1 Pre-wired (2 m) Standard M8 connector E3Z-D81 2M E3Z-D66 E3Z-D86 E3Z-D62 2M E3Z-D82 2M E3Z-D67 E3Z-D87 E3Z-L61 2M E3Z-L81 2M E3Z-L66 E3Z-L86 E3Z-LS61 2M E3Z-LS81 2M E3Z-LS66 E3Z-LS86 E3Z-G61 2M 25 mm Standard M8 connector E3Z-D61 2M 2 to 20 mm (BGS min setting) E3Z-LS63 2M 2 to 80 mm (BGS max setting) E3Z-LS68 Pre-wired (2 m) Pre-wired (2 m) Retro-reflective without MSR function for clear, plastic bottles 4 m *2 Pre-wired (2 m) Limited-reflective for transparent glasses E3Z-T87-G0 *4 Emitter E3Z-T87-G0-L Receiver E3Z-T87-G0-D (100 mm) Pre-wired (2 m) Diffuse-reflective PNP output E3Z-T81 2M Emitter E3Z-T81-L 2M Receiver E3Z-T81-D 2M 15 m Retro-reflective with MSR function NPN output E3Z-T61 2M Emitter E3Z-T61-L 2M Receiver E3Z-T61-D 2M Pre-wired (2 m) Through-beam (Emitter + Receiver) *3 Infrared light Model 3020 mm *2 500 mm (80 mm) *2 2 m (500 mm) E3Z-LS83 2M E3Z-LS88 E3Z-G81 2M E3Z-G62 2M E3Z-G82 2M E3Z-G61-M3J E3Z-G81-M3J E3Z-G62-M3J E3Z-G82-M3J E3Z-L63 2M E3Z-L83 2M E3Z-L68 E3Z-J88 E3Z-B61 2M E3Z-B81 2M E3Z-B66 E3Z-B86 E3Z-B62 2M E3Z-B82 2M E3Z-B67 E3Z-B87 *1. The Reflector is sold separately. Select the Reflector model most suited to the application. *2. The sensing distance specified is possible when the E39-R1S is used. Values in parentheses indicate the minimum required distance between the Sensor and Reflector. *3. Through-beam Sensors are normally sold in sets that include both the Emitter and Receiver. Orders for individual Emitters and Receivers are accepted. (Modifications are required for some models. Ask your OMRON representative for details.) *4. Models with emission stop function. Refer to page 8, Photoelectric Sensors Technical Guide for details. 2 E3Z Variety of Connection Specifications The models with the connection specifications marked with a black circle in the table are available. The model number indication is a combination of the basic model and the connection specification. Example: E3Z-T61-M1TJ 0.3M Basic model number Connection specification NPN Output Model number example Model Sensing method Throughbeam Retroreflective Diffusereflective (narrowbeam reflective) Distancesettable Slit-type Retroreflective for clear, plastic bottles Sensing distance Main features E3Z-T61 -M1TJ 0.3M E3Z-T61 0.5M M12 preConnecPre-wired wired Smarttion click connec- (cable length: specifi0.5 m) tor (cable cation length: 0.3 m) Basic model number E3Z-T61 5M Pre-wired (cable length: 5 m) E3Z-T61 -M1J 0.3M E3Z-T61 -M3J 0.3M E3Z-T61 -ECON 0.3M E3Z-T61 -ECON 0.5M M12 pree-CON preM8, 4-pin prewired stanwired conwired condard connecnector (cable nector (cable tor (cable length: 0.3 m/ length: 0.3 m) length: 0.3 m) 0.5 m) -M1TJ 0.3M 0.5M 5M -M1J 0.3M -M3J 0.3M -ECON 0.3M -ECON 0.5M E3Z-T61 -ECON 2M e-CON prewired connector (cable length: 2 m) -ECON 2M 15 m Infrared E3Z-T61 light 10 m Red light --- --- 30 m 2-ms reE3Z-T62 sponse --- --- --- --- --- --- 4m MSR E3Z-R61 function 100 mm Wide view E3Z-D61 --- 1m Long distance E3Z-D62 90 mm Narrow beam E3Z-L61 --- 200 mm FGS E3Z-LS61 function --- 80 mm Small spot --- --- --- --- --- --- 1 optical E3Z-G61 axis 2 optical E3Z-G62 axes --- E3Z-B61 --- --- --- No MSR function E3Z-B62 --- --- 25 mm 500 mm 2m E3Z-T61A E3Z-LS63 Clamp-type e-CON pre-wired connectors are also available for models shaded in Add "-ECON-C 2M" after the basic model number to specify the connectors. . 3 E3Z PNP Output Model number example Model Sensing method Throughbeam Retroreflective Diffusereflective (narrowbeam reflective) Distancesettable Slit-type Retroreflective for clear, plastic bottles Sensing distance Main features E3Z-T81 -M1TJ 0.3M E3Z-T81 -M3J 0.3M E3Z-T81 5M Pre-wired (cable length: 0.5 m) Pre-wired (cable length: 5 m) -M1TJ 0.3M 0.5M 5M -M1J 0.3M -M3J 0.3M M12 pre-wired ConnecSmartclick tion connector specifi(cable length: cation 0.3 m) Basic model number E3Z-T81 -M1J 0.3M E3Z-T81 0.5M M12 pre-wired M8, 4-pin prestandard con- wired connecnector (cable tor (cable length: 0.3 m) length: 0.3 m) 15 m Infrared E3Z-T81 light 10 m Red light --- --- --- --- 30 m 2-ms reE3Z-T82 sponse --- --- --- --- 4m MSR E3Z-R81 function 100 mm Wide view E3Z-D81 1m Long distance E3Z-D82 90 mm Narrow beam E3Z-L81 --- 200 mm FGS E3Z-LS81 function --- 80 mm Small spot --- --- --- --- 1 optical E3Z-G81 axis --- 2 optical E3Z-G82 axes --- --- E3Z-B81 --- --- --- No MSR function E3Z-B82 --- --- 25 mm 500 mm 2m E3Z-T81A E3Z-LS83 4 E3Z Oil-resistive Sensors [Refer to Dimensions on page 16.] Sensing method Connection method Appearance Red light Sensing distance NPN output Pre-wired (2 m) 15 m Pre-wired M8 connector Pre-wired (2 m) Retro-reflective with MSR function PNP output E3Z-T61K 2M Emitter E3Z-T61K-L 2M Receiver E3Z-T61K-D 2M Through-beam (Emitter + Receiver) *3 *2 3 m (150 mm) *1 Pre-wired M8 connector Pre-wired (2 m) Pre-wired M8 connector Infrared light Model 5 to 100 mm (wide view) E3Z-T81K 2M Emitter E3Z-T81K-L 2M Receiver E3Z-T81K-D 2M E3Z-T61K-M3J 0.3M E3Z-T81K-M3J 0.3M Emitter E3Z-T61K-L-M3J 2M Emitter E3Z-T81K-L-M3J 2M Receiver E3Z-T61K-D-M3J 2M Receiver E3Z-T81K-D-M3J 2M E3Z-R61K 2M E3Z-R81K 2M E3Z-R61K-M3J 0.3M E3Z-R81K-M3J 0.3M E3Z-D61K 2M E3Z-D81K 2M E3Z-D61K-M3J 0.3M E3Z-D81K-M3J 0.3M E3Z-D62K 2M E3Z-D82K 2M E3Z-D62K-M3J 0.3M E3Z-D82K-M3J 0.3M Diffuse-reflective Pre-wired (2 m) Pre-wired M8 connector 1m *1. The Reflector is sold separately. Select the Reflector model most suited to the application. *2. The sensing distance specified is possible when the E39-R1S is used. Values in parentheses indicate the minimum required distance between the Sensor and Reflector. *3. Through-beam Sensors are normally sold in sets that include both the Emitter and Receiver. Orders for individual Emitters and Receivers are accepted. (Modifications are required for some models. Ask your OMRON representative for details.) Accessories (Order Separately) Slit (A Slit is not provided with Through-beam Sensors) Order a Slit separately if required. [Refer to Dimensions on page 18.] Slit width 0.5-mm dia. 1-mm dia. 2-mm dia. 0.5 x 10 mm 1 x 10 mm 2 x 10 mm Sensing distance E3Z-T@@ E3Z-T@@A 50 mm 35 mm 200 mm 150 mm 800 mm 550 mm 1m 700 mm 2.2 m 1.5 m 5m 3.5 m Minimum detectable object (typical) 0.2-mm dia. 0.4-mm dia. 0.7-mm dia. 0.2-mm dia. 0.5-mm dia. 0.8-mm dia. Model Contents E39-S65A E39-S65B E39-S65C E39-S65D E39-S65E E39-S65F One set (contains Slits for both the Emitter and Receiver) Reflectors (Reflector required for Retroreflective Sensors) A Reflector is not provided with the Sensor. Be sure to order a Reflector separately. [Refer to Dimensions on E39-L/F39-L/E39-S/E39-R] Name Reflector Fog Preventive Coating Small Reflector Tape Reflector Sensing distance (typical)* E3Z-R@K E3Z-B@1/-B@6 2 m (100 mm) --(rated value) 3 m (150 mm) 500 mm (80 mm) (rated value) (rated value) E3Z-R 3 m (100 mm) (rated value) 4 m (100 mm) (rated value) 5 m (100 mm) 2.5 m (100 mm) 3.5 m (100 mm) E3Z-B@2/-B@7 Model Quantity --- E39-R1 1 2 m (500 mm) (rated value) E39-R1S 1 E39-R2 E39-R9 E39-R10 1 1 1 E39-R1K 1 E39-R3 E39-RS1 E39-RS2 E39-RS3 1 1 1 1 --- --- --- --- --- --- --- --- --- 3 m (100 mm) --- 500 mm (80 mm) (rated value) 2 m (500 mm) (rated value) 1.5 m (50 mm) 700 mm (150 mm) 1.1 m (150 mm) 1.4 m (150 mm) --- --- --- --- --- --- --- --- --- --- --- --- Remarks * Retro-reflective models are not provided with Reflectors. * The MSR function is enabled. Note: The actual sensing distance may be reduced to approximately 70% of the typical sensing distance when using a Reflector other than E39-R1 or E39-R1S. *1. Refer to Reflectors on E39-L/F39-L/E39-S/E39-R for details. *2. Values in parentheses indicates the minimum required distance between the Sensor and Reflector. Mutual Interference Protection Filter A Filter is not provided with the Sensor (for the through-beam E3Z-T@@A). Order a Filter separately if required. Sensing distance Appearance/Dimensions 10.8 7.4 Model Quantity Remarks Two sets each for the Emitter and Receiver (total of four pieces) Can be used with the E3Z-T@@A Throughbeam models. The arrow indicates the direction of polarized light. Mutual interference can be prevented by altering the direction of polarized light from or to adjacent Emitters and Receivers. 4.9 1 3m E39-E11 31.4 11.2 0.2 5 E3Z Mounting Brackets A Mounting Bracket is not enclosed with the Sensor. Order a Mounting Bracket separately if required. [Refer to Dimensions on E39-L/F39-L/E39-S/E39-R] Appearance Model (material) E39-L153 (SUS304) *1 Quantity Remarks Appearance Model (material) 1 Quantity Remarks E39-L98 (SUS304) *2 1 Metal Protective Cover Bracket E39-L150 (SUS304) 1 Mounting Brackets E39-L104 (SUS304) *1 1 (Sensor adjuster) E39-L43 (SUS304) *2 Easily mounted to the aluminum frame rails of conveyors and easily adjusted. Horizontal Mounting Brackets 1 E39-L142 (SUS304) *2 1 Horizontal Protective Cover Bracket E39-L44 (SUS304) 1 Rear Mounting Bracket E39-L151 (SUS304) 1 E39-L144 (SUS304) *2 1 For left to right adjustment Compact Protective Cover Bracket (For E3Z only) Note: 1. When using Through-beam models, order one bracket for the Receiver and one for the Emitter. 2. Refer to Mounting Brackets on E39-L/F39-L/E39-S/E39-R for details. *1. Cannot be used for Standard Connector models with mounting surface on the bottom. In that case, use Pre-wired Connector models. *2. Cannot be used for Standard Connector models. Sensor I/O Connectors (Models for Connectors and Pre-wired Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.) [Refer to Dimensions for XS3, XS2, XS5. For e-CON, inquire.] Size Cable Appearance Straight *3 M8 *1 Straight *3 L-shaped *3 Standard XS2F-D421-DC0-A 3-wire 432 1 XS2F-D421-GC0-A 2m XS2F-D422-DC0-A 5m XS2F-D422-GC0-A 0.5 to 1 m 12 3 4 432 1 XS3F-M422-405-A 4-wire E39-ECON5M E39-ECONW@M @ indicates cable length (in units of m). Specify with 0.1-increments. 1.6 to 2 m 2m 2m 5m XS5F-D421-G80-A 4-wire 1.1 to 1.5 m 5m XS5F-D421-D80-A E39-ECON2M 5m Double-end connectors XS3F-M422-402-A 2m 2m e-CON L-shaped *3 *4 4-wire 5m 5m Single-end connector M8 XS3F-M421-405-A 2m Straight Straight *3 5m 5m M12 *1 (For -M1J models) PUR (Polyurethane) cable *2 Model XS3F-M421-402-A 2m L-shaped *3 *4 M12 (For -M1TJ models) Cable type 2m XS3F-M421-402-L 4-wire XS3F-M421-405-L XS3F-M422-402-L XS3F-M422-405-L Note: When using Through-beam models, order one connector for the Receiver and one for the Emitter. *1. Refer to Introduction to Sensor I/O Connectors for details. *2. The Sensor can be used in low-temperature environments (-25C to -40C). Do not use the Sensor in locations that are subject to oil. *3. The connector will not rotate after connecting. *4. The cable is fixed at an angle of 180 from the sensor emitter/receiver surface. 6 E3Z Ratings and Specifications Sensing method Model Item Retro-reflective with MSR function Through-beam NPN Pre-wired output Connector (M8) E3Z-T61 E3Z-T62 E3Z-T61A E3Z-R61 E3Z-D61 E3Z-D62 E3Z-L61 E3Z-T66 E3Z-T67 E3Z-T66A E3Z-R66 E3Z-D66 E3Z-D67 E3Z-L66 PNP Pre-wired output Connector (M8) E3Z-T81 E3Z-T82 E3Z-T81A E3Z-R81 E3Z-D81 E3Z-D82 E3Z-L81 E3Z-T86 E3Z-T87 E3Z-T86A E3Z-R86 E3Z-D86 E3Z-D87 E3Z-L86 1m (white paper: 300 x 300 mm) 90 + 30 mm (white paper, 100 x 100 mm) Sensing distance 15 m 30 m 4 m (100 mm) *1 100 mm (when using E39-R1S) (white paper: 3 m (100 mm) *1 100 x 100 mm) (when using E39-R1) 10 m Spot diameter (typical) (2.5 dia. and sensing distance of 90 mm) --- Standard sensing object Opaque: 12-mm dia. min. Opaque: 75-mm dia. min. Minimum detectable object (typical) --- Directional angle Both emitter and receiver: 3 to 15 0.1 mm (copper wire) 2 to 10 Red LED (660 nm) --- Infrared LED (870 nm) Current consumption 35 mA max. (Emitter: 15 mA max., Receiv30 mA max. er: 20 mA max.) Protection circuits Reversed power supply polarity protection, Output short-circuit protection, and Reversed output polarity protection Response time Operate or reset: 1 ms max. Degree of protection IEC, IP67 Connection method Pre-wired cable (standard length: 2 m and 0.5 m), Connector (M8) Operate or reset: 2 ms max. Item Red LED (660 nm) Operate or reset: 1 ms max. Approx. 120 g Approx. 65 g Connector Approx. 30 g Approx. 20 g Case PBT (polybutylene terephthalate) Lens Modified polyarylate Model Red LED (650 nm) Infrared LED (860 nm) Reversed power supply polarity protection, Output short-circuit protection, Mutual interference prevention, and Reversed output polarity protection Pre-wired cable (2 m) Sensing method Refer to Engineering data on page 10. 20% max. of setting distance Light source (wavelength) Material --- --- Differential travel Weight (packedstate) (Narrowbeam Models) Diffuse-reflective Methacrylic resin Modified polyarylate Retro-reflective for clear, plastic bottles (without MSR function) NPN output E3Z-B61 E3Z-B66 E3Z-B62 E3Z-B67 PNP output E3Z-B81 E3Z-B86 E3Z-B82 E3Z-B87 Sensing distance 500 mm (80 mm) *1 (using E39-R1S) Standard sensing object 500-ml (65-mm dia.) transparent round plastic bottles Light source (wavelength) Red LED (660 nm) Current consumption 30 mA max. Protection circuits Reversed power supply polarity protection, Output short-circuit protection, Mutual interference prevention, and Reversed output polarity protection Response time Operate or reset: 1 ms max. Degree of protection IEC, IP67 Connection method Pre-wired cable (standard Connector (M8, 4 pins) length: 2 m and 0.5 m) Weight (packed state) Material Pre-wired cable (2 m) Approx. 65 g Standard Connector Approx. 20 g Case PBT (polybutylene terephthalate) Lens Modified polyarylate 2 m (500 mm) *1 *2 (using E39-R1S) Pre-wired cable (standard Connector (M8, 4 pins) length: 2 m and 0.5 m) *1. Values in parentheses indicate the minimum required distances between the Sensors and Reflectors. *2. Plastic bottles must pass with the minimum clearance of 500 mm. 7 E3Z The E3Z-T@2-G0 is equipped with an emission stop function. Ratings and specifications of this function are given in the following table. Sensing method Through-beam models, NPN output: E3Z-T62/T67-G0, PNP output: E3Z-T82/T87-G0 Output and Modes Item Emission stop function Input Emission OFF: Short-circuit to 0 V or 1.5 V max. (Outflow current 1 mA max.), Emission ON: Disconnected (Leakage current 0.1 mA max.) Emission OFF: Short-circuit to +DC (Power supply plus side) or +DC-1.5 V max. (Inlet current 3 mA max.), Emission ON: Disconnected (Leakage current 0.1 mA max.) Response time Operate or reset: 0.5 ms max. Visible spot models are available for through-beam NPN output models. The different items from E3Z-T62 are listed below. Model E3Z-T62-SOSDW-P2 Light source (wavelength) Orange LED (615 nm) Response time Operate or reset: 1 ms max. Connection method Pre-wired lable (Standard length: 2 m) Sensing method Transparent glass Limited-reflective (for transparent object detection ) Model NPN output E3Z-L63 E3Z-L68 PNP output E3Z-L83 E3Z-L88 Item Sensing distance 3020 mm (transparent glasses 100 x 100 mm) Spot diameter 2-mm dia. min. (at sensing distance of 30 mm) Minimum detectable object (typical) 0.1 mm dia. (copper wire) Light source (wavelength) Red LED (660 nm) Current consumption 30 mA max. Protection circuits Power supply reverse polarity protection, Output short-circuit protection, Mutual interference prevention, Reverse output polarity protection Response time Operate or reset: 1 ms max. Degree of protection IEC, IP67 Connection method Weight (packed state) Material Pre-wired (standard length: 2 m) Pre-wired cable (2 m) Approx. 65 g Standard Connector Approx. 20 g Case PBT (polybutylene terephthalate) Lens Modified polyarylate M8 connector 8 E3Z Oil-resistant Sensing method Model Through-beam Retro-reflective Diffuse-reflective NPN Pre-wired Models E3Z-T61K outM8 Pre-wired connector E3Z-T61K-M3J put E3Z-R61K E3Z-D61K E3Z-D62K E3Z-R61K-M3J E3Z-D61K-M3J E3Z-D62K-M3J PNP Pre-wired Models E3Z-T81K outM8 Pre-wired connector E3Z-T81K-M3J put E3Z-R81K E3Z-D81K E3Z-D82K E3Z-R81K-M3J E3Z-D81K-M3J E3Z-D82K-M3J 3 m (150 mm) * (when using E39-R1S) 2 m (100 mm) * (when using E39-R1) 100 mm (white paper: 100 x 100 mm) 1m (white paper: 300 x 300 mm) Item Sensing distance 15 m Standard sensing object Opaque: 12-mm dia. min. Differential travel Opaque: 75-mm dia. min. --- --20% max. of setting distance Directional angle Both emitter and receiver: 3 to 15 2 to 10 Light source (wavelength) Infrared LED (870 nm) Red LED (660 nm) Current consumption 35 mA max. (Emitter: 15 mA max., Receiver: 20 mA max.) 30 mA max. Protection circuits Reversed power supply polarity protection, Output short-circuit protection, and Reversed output polarity protection Reversed power supply polarity protection, Output short-circuit protection, Mutual interference prevention, and Reversed output polarity protection Response time Operate or reset: 1 ms max. Degree of protection IP67 (IEC), Oil resistant models: IP67 (IEC) (in-house standards: oilproof), excluding cables and connectors --Infrared LED (860 nm) Connection method Pre-wired cable (standard length: 2 m), M8 Pre-wired Connector Weight Pre-wired cable (2 m) (packed Connector (M8, 4 pins) state) Approx. 120 g Approx. 65 g Approx. 50 g Approx. 30 g Material Case PBT (polybutylene terephthalate) Lens Modified polyarylate Methacrylic resin Modified polyarylate * Values in parentheses indicate the minimum required distance between the Sensor and Reflector. Common Power supply voltage 12 to 24 VDC10%, ripple (p-p): 10% max. Control output Load power supply voltage: 26.4 VDC max., Load current: 100 mA max. Residual voltage: Load current of less than 10 mA: 1 V max. Load current of 10 to 100 mA: 2 V max. Open collector output (NPN/PNP depending on model) Light-ON/Dark-ON selectable Sensitivity adjustment One-turn adjuster Ambient illumination (Receiver side) Incandescent lamp: 3,000 lx max. Sunlight: 10,000 lx max. Ambient temperature range Operating: -25 to 55C, Some connector models: -40C to 55C * (with no icing or condensation) Storage: -40 to 70C (with no icing or condensation) Ambient humidity range Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) Insulation resistance 20 M min. at 500 VDC Dielectric strength 1,000 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 500 m/s2 3 times each in X, Y, and Z directions Indicator Operation indicator (orange) Stability indicator (green) Through-beam Emitter has power indicator (orange) only. Accessories Instruction manual (Neither Reflectors nor Mounting Brackets are provided with any of the above models.) * The ambient temperature range during operation for connector models depends on the model. For the E3Z-T66/T86/R66/R86, the range is -40C to 55C. For the E3Z-D66/D86/D67/D87, the range is -30C to 55C. For other connector models, the range is -25C to -55C. The sensing distance for Retro-reflective Models (E3Z-R66/R86) between -40C to -25C, however, will be as follows (not the values in the table): With E39-R1S: 3 m (100 mm), With E39-R1: 2 m (100 mm). Also, use the XS3F-M42@-4@@-L Sensor I/O Connector (PUR cable) for applications between -25C to -40C. (Refer to page 6.) 9 E3Z Engineering Data (Typical) Parallel Operating Range E3Z-T@1(T@6) E3Z-T@A E3Z-T@2(T@7) 1000 800 600 400 Distance Y (mm) Through-beam Models Distance Y (mm) Through-beam Models Distance Y (mm) Through-beam Models 1000 800 Y 600 X 400 200 0 10 20 30 0 40 Distance X (m) 10 20 30 -200 -400 -400 -600 -600 Y -800 0 40 Distance X (m) -1000 10 20 30 -1.0 -1.5 -2.0 -1000 E3Z-T@1(T@6) and Slit (A Slit is mounted to the Emitter and Receiver.) E3Z-T@A and Slit (A Slit is mounted to the Emitter and Receiver.) E3Z-R@1(R@6) and Reflector 200 Y 150 X 100 Distance Y (mm) Retro-reflective Models Distance Y (mm) Through-beam Models Distance Y (mm) Through-beam Models 250 200 Y 150 X 100 200 E39-R1K 150 E39-R10 Y E39-R3 X 100 50 50 50 40 Distance X (m) -0.5 -800 X 1.0 0.5 200 -200 2.0 1.5 Distance X (m) 0 1 2 3 4 0 5 Distance X (m) -50 -100 E39-S65C E39-S65D -200 E39-S65F 30 Y X 0 -10 0.5 1 1.5 2 2.5 3 100 8 -50 E39-S65D -150 E39-S65E E39-S65F E39-R9 E39-R1 E39-R1S E39-R2 -200 Reflector: E39-R1S Y 40 X 0 0.5 1 -20 -40 -60 -80 500-mm type 6 60 -30 -50 4 80 -20 -40 2 -100 20 Distance X (m) 0 E3Z-B@2/B@7 + E39-R1S Reflector (Order Separately) Distance Y (mm) Distance Y (mm) Reflector: E39-R1S 40 5 E39-S65C -200 E3Z-B@1/B@6 + E39-R1S Reflector (Order Separately) 10 4 E39-S65B -150 20 3 Distance X (m) E39-S65E -250 50 2 -50 -100 E39-S65B -150 1 1.5 2 2.5 3 3.5 4 4.5 Distance X (m) 2-m type -100 10 E3Z Operating Range E3Z-D@1(D@6) E3Z-D@2(D@7) E3Z-L@1(L@6) 30 Sensing object: 100 x 100 mm white paper Y 20 X 10 80 Distance Y (mm) Narrow-beam Reflective Models Distance Y (mm) Diffuse-reflective Models Distance Y (mm) Diffuse-reflective Models Sensing object: 300 x 300 mm white paper 60 Y 40 X 10 50 100 150 200 0 250 Distance X (m) -10 Y 6 X 4 20 0 Sensing object: 100 x 100 mm white paper 8 2 0.2 0.4 0.6 0.8 1.4 1.6 0 Distance X (m) -2 1.2 1.0 -20 50 100 150 250 200 Distance X (m) -4 -40 -6 -20 -60 -8 -80 -30 -10 Excess Gain vs. Set Distance E3Z-T@1(T@6)/-T@A/-T@2(T@7) E3Z-R@1(R@6) and Reflector E3Z-D@1(D@6) 100 Excess gain ratio Diffuse-reflective Models Excess gain ratio Retro-reflective Models Excess gain ratio Through-beam Models 100 E3Z-T@2 (T@7) 10 E39-R9 E39-R1K 10 E39-R10 E3Z-T@A E39-R1S 100 70 50 Sensing object: 100 x 100 mm white paper 30 10 7 5 3 E39-R2 1 1 Operating 1 level 0.7 E39-R3 E3Z-T@1 (T@6) 0.5 0.3 E39-R1 0.1 0 10 20 30 40 50 60 70 0.1 0.1 0 80 2 4 6 8 10 0 50 100 150 200 E3Z-L@1(L@6) E3Z-L@3(L@8) 30 10 7 5 Excess gain ratio E3Z-D@2(D@7) Excess gain ratio Limited reflective Models Excess gain ratio Narrow-beam Reflective Models Sensing object: 300 x 300 mm white paper 100 70 50 30 10 7 5 300 350 Distance (m) Diffuse-reflective Models 100 70 50 250 Distance (m) Distance (m) 100 70 50 30 SUS 10 7 5 3 3 3 Operating 1 level Operating 1 level Operating 1 level 0.3 0.3 0.3 White paper 0.7 0.5 0.1 0.7 0.5 0 0.5 1 1.5 2 2.5 3 Distance (m) 0.1 0.7 0.5 0 50 100 150 200 250 300 350 Distance (m) 0.1 Glass 0 20 40 60 80 100 120 Distance (m) 11 E3Z Excess Gain vs. Set Distance E3Z-B@2/B@7 + E39-R1S Reflector (Order Separately) 100 500-mm type Excess gain ratio Excess gain ratio E3Z-B@1/B@6 + E39-R1S Reflector (Order Separately) 100 2-m type 10 10 1 1 0.1 0.1 0.5 1 1.5 2 0.5 2.5 3 Distance (m) 1 1.5 2 2.5 3 3.5 4 4.5 5 Distance (m) Diffuse-reflective Models Narrow-beam Reflective Models E3Z-D@1(D@6) E3Z-D@2(D@7) E3Z-L@1(L@6) Distance (m) Distance (mm) Diffuse-reflective Models Distance (m) Sensing Object Size vs. Sensing Distance 350 d 300 White paper d SUS (glossy surface) 250 4.5 d 4 d SUS (glossy surface) 3.5 2.5 150 2 White paper 1 0 50 100 150 200 250 50 Black paper 0.5 300 350 0 50 100 150 200 250 300 350 Side length (one side) of sensing object: d (mm) Side length (one side) of sensing object: d (mm) Narrow-beam Reflective Models Narrow-beam Reflective Models E3Z-L@1(L@6) E3Z-L@1(L@6) Differential travel (mm) Differential Travel vs. Sensing Distance Spot diameter (mm) Spot Diameter vs. Sensing Distance 4.0 3.5 3.0 2.5 White paper 100 1.5 Black paper d 150 100 50 d 250 200 3 200 300 0 1 2 3 5 7.5 10 20 30 100 Side length (one side) of sensing object: d (mm) 30 25 20 15 2.0 1.5 10 1.0 5 0.5 0 20 40 60 80 100 120 140 160 Distance (mm) 0 50 75 100 125 150 Distance (mm) 12 E3Z I/O Circuit Diagrams NPN Output Model* Operation mode Timing charts Operation selector Output circuit Through-beam Receivers, Retro-reflective Models, Diffuse-reflective Models, Limited reflective Models. Incident light E3Z-T61(K) E3Z-T66 E3Z-T62 E3Z-T67 E3Z-T61A E3Z-T66A E3Z-R61(K) E3Z-R66 E3Z-D61(K) E3Z-D66 E3Z-D62(K) E3Z-D67 E3Z-L61 E3Z-L66 E3Z-B61 E3Z-B66 E3Z-B62 E3Z-B67 E3Z-L63 E3Z-L68 Light-ON No incident light Operation ON indicator OFF (orange) ON Output transistor OFF Operation indicator L side (LIGHT ON) 1 Stability indicator (Green) (Orange) Operate Load (e.g., relay) Reset (Between brown (1) and black (4) leads) Dark-ON Incident light No incident light Operation ON indicator OFF (orange) ON Output transistor OFF Operate Load (e.g., relay) Reset (Between brown (1) and black (4) leads) Photoelectric Sensor main circuit D side (DARK ON) 100 mA max. Load (Relay) Blue 2 1 e-CON Connector Pin Arrangement 3 Brown Photoelectric Sensor main circuit 2 12 to 24 VDC e-CON Connector Pin Arrangement Through-beam Emitter --- 1 2 Clamp type 3 3 4 3 4 Pins 2 and 4 are not used. Blue Press fit 1 2 4 1 Clamp 1 2 3 4 3 4 Connector Pin Arrangement 1 Emission ON stop input OFF Press fit 1 2 4 Pin 2 is not used. Power indicator (orange) (Between blue (3) and pink (2) leads) ON LED for emission OFF Indicator ON (orange) OFF 3 Black 0V Through-beam Emitter --- 4 ZD Connector Pin Arrangement 3 E3Z-T62-G0 E3Z-T67-G0 (Control output) 12 to 24 VDC Brown Brown Power indicator (Orange) 1 Photoelectric Sensor main circuit 2 Connector Pin Arrangement 12 to 24 VDC 2 Pink 0V 3 4 1 (Emission stop input) 3 Pin 4 is not used. Blue PNP Output Model* E3Z-T81(K) E3Z-T86 E3Z-T82 E3Z-T87 E3Z-T81A E3Z-T86A E3Z-R81(K) E3Z-R86 E3Z-D81(K) E3Z-D86 E3Z-D82(K) E3Z-D87 E3Z-L81 E3Z-L86 E3Z-B81 E3Z-B86 E3Z-B82 E3Z-B87 E3Z-L83 E3Z-L88 Operation mode Timing charts Light-ON Incident light No incident light Operation ON indicator OFF (orange) ON Output transistor OFF Operate Load (e.g., relay) Reset (Between blue (3) and black (4) leads) Dark-ON Incident light No incident light Operation ON indicator OFF (orange) ON Output transistor OFF Operate Load (e.g., relay) Reset (Between blue (3) and black (4) leads) Operation selector Output circuit Through-beam Receivers, Retro-reflective Models, Diffuse-reflective Models, Limited reflective Models. L side (LIGHT ON) Operation indicator (Orange) 4 (Control output) 3 Black 100 mA Bluemax. Load (Relay) 0V Connector Pin Arrangement D side (DARK ON) 2 4 1 3 Pin 2 is not used. Brown Through-beam Emitter 1 Power indicator (orange) Connector Pin Arrangement Photoelectric Sensor Main Circuit 12 to 24 VDC Blue Through-beam Emitter Emission ON stop input OFF --- 12 to 24 VDC ZD Photoelectric Sensor main circuit 3 E3Z-T82-G0 E3Z-T87-G0 Brown 1 Stability indicator (Green) (Between brown (1) and pink (2) leads) ON LED for emission OFF Indicator ON (orange) OFF --- 2 1 4 3 Pins 2 and 4 are not used. Brown Power indicator (Orange) 1 Photoelectric Sensor main circuit 2 12 to 24 VDC (Emission stop input) Connector Pin Arrangement 2 1 4 3 Pink 0V 3 Pin 4 is not used. Blue * Models numbers for Through-beam Sensors (E3Z-T@@) are for sets that include both the Emitter and Receiver. The model number of the Emitter is expressed by adding "-L" to the set model number (example: E3Z-T61-L 2M), the model number of the Receiver, by adding "-D" (example: E3Z-T61-D 2M.) Refer to Ordering Information to confirm model numbers for Emitter and Receivers. 13 E3Z Plugs (Sensor I/O Connectors) M8 connector e-CON connector Classification Wire color 4 3 2 1 Brown White Blue Black 1 2 3 4 XS3F-M421-402-A XS3F-M421-405-A XS3F-M422-402-A XS3F-M422-405-A Pin arrangement E39-ECON@M DC E39-ECONW@M Wire color Connector pin No. Brown 1 Power supply (+V) White 2 (Emission stop input) Blue 3 Power supply (0 V) Black 4 Output Application Note: Pin 2 is not used. Nomenclature Through-beam Models E3Z-T@@ (Emitter) E3Z-T@@A (Receiver) Retro-reflective Models E3Z-R@@ E3Z-B@@ Stability indicator (green) Operation indicator (orange) Sensitivity adjuster Operation selector Diffuse-reflective Models E3Z-D@@ Narrow-beam Reflective Models E3Z-L@@ Limited reflective Models E3Z-L@@ 14 E3Z Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Oil-resistant Models Oil Resistance Do not use the product in atmospheres or environments that exceed product ratings. * Although the E3Z-@@@K Sensors have oil-resistant specifications, performance may be affected by certain types of oil. Refer to the following table. * E3Z-@@@K Sensors are tested for resistance to the oils given in the following table. Refer to the information in the table when deciding which type of oil to use. Wiring M8 Metal Connector Test oil classification Precautions for Correct Use * Be sure to connect or disconnect the metal connector after turning OFF the Sensor. * Hold the connector cover to connect or disconnect the metal connector. * Secure the connector cover by hand. Do not use any pliers, otherwise the connector may be damaged. * The proper tightening torque range is between 0.3 and 0.4 N*m. Be sure to tighten the connector securely, otherwise the specified degree of protection may not be maintained or the connector may be disconnected due to vibration. Mounting Sensor Mounting Use M3 screws to mount the sensor and tighten each screw to a maximum torque of 0.53 N*m. E3Z-@@@ Product name Kinematic viscosity (mm2/s) at 40C 2.02 Lubricant Velocity No.3 Water insoluble machining Yushiron Oil No.2 ac Less than 10 oil Yushiroken EC50T-3 Water soluble Yushiron Lubic HWC68 --machining oil Gryton 1700D Yushironken S50N pH --7 to 9.5 7 to 9.9 7 to 9.2 7 to 9.8 Note: 1. The E3Z maintained a minimum insulation resistance of 100 M after it was dipped in all the above oils for 240 hours. 2. When using the Sensors in environments subject to oils other than those listed above, use the figures for kinematic viscosity and pH from the table as general guidelines. Additives and other substances contained in oils may affect the E3Z. Be sure to consider this before use. E39-L104 Mounting Bracket (sold separately) 15 E3Z (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Sensors Through-beam* Pre-wired Models E3Z-T61(K) E3Z-T81(K) E3Z-T61A E3Z-T81A E3Z-T62(-G0) E3Z-T82(-G0) (Excluding -G0) 12 Terminal No. 1 2 3 4 Emitter Power indicator (orange) 10.8 7.2 2.1 20 2.8 3 Lens Pins 2 and 4 are not used. (-G0) 12.7 31 Terminal No. 1 2 3 4 25.4 11 Specifications +V --0V --- Two, M3 4 dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm), Standard length: 2 m 4 dia. vinyl-insulated round cable with 2 or 3 conductors, Standard length: 0.3 m 1 1 Press-fit e-CON Pre-wired Connector 5.9 15 15.6 4 dia. vinyl-insulated round cable with 2 or 3 conductors, Standard length: 0.3 m,0.5m, and 2m Operation selector Sensitivity adjuster 10.8 20 2.8 3 Clamp-type e-CON Pre-wired Connector (E3Z-T61-ECON-C) 6 Lens 1 2 3 4 12.7 25.4 11 Terminal No. Specifications 1 +V Two, M3 4 dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter:1.1 mm), Standard length: 2 m Through-beam* Connector Models E3Z-T66 E3Z-T86 E3Z-T66A E3Z-T86A E3Z-T67(-G0) E3Z-T87(-G0) 3 M8 1 2 3 4 Stability indicator (green) 31 3 4 dia. vinyl-insulated round cable with 2 or 3 conductors, Standard length: 0.3 m 2 4 7.5 7.2 4 M8 Pre-wired Connector (E3Z-T@@K-M3J) Receiver 2.1 2 M12x1 Pin 4 is not used. 4.5 11.2 Operation Indicator (orange) Specifications +V Input 0V --- M12 Pre-wired Connector (E3Z-T@@-M1J) 2 --- 3 0V 4 Output 15.8 18 4 dia. vinyl-insulated round cable with 2 or 3 conductors, Standard length: 2m * The Emitter cable has two conductors and the Receiver cable has three conductors. Pin 2 is not used. (Excluding -G0) 12 Terminal No. Specifications 1 +V Emitter Power indicator (orange) 10.8 7.2 2.1 2.8 20 3 Lens 25.4 11 10.4 --- 3 0V 4 --- Pins 2 and 4 are not used. (-G0) 12.7 31 2 Terminal No. Specifications 1 +V 2 Input Two, M3 3 0V M8 connector 4 --- 9.75 11.2 Operation Indicator (orange) 7.5 Pin 4 is not used. 4.5 Operation selector Receiver Stability indicator (green) Sensitivity adjuster 10.8 7.2 2.1 2.8 20 3 Lens 12.7 31 10.4 11 25.4 Two, M3 M8 connector 9.75 Terminal No. Specifications 1 +V 2 --- 3 0V 4 Output Pin 2 is not used. * Models numbers for Through-beam Sensors (E3Z-T@@) are for sets that include both the Emitter and Receiver. The model number of the Emitter is expressed by adding "-L" to the set model number (example: E3Z-T61-L 2M), the model number of the Receiver, by adding "-D" (example: E3Z-T61-D 2M.) Refer to Ordering Information to confirm model numbers for Emitter and Receivers. 16 E3Z Retro-reflective Models Pre-wired Models E3Z-R61(K) E3Z-B61 E3Z-R81(K) E3Z-B81 E3Z-D61(K) E3Z-B62 E3Z-D81(K) E3Z-B82 E3Z-D62(K) E3Z-L63 E3Z-D82(K) E3Z-L83 E3Z-L61 E3Z-L81 M12 Pre-wired Connector (E3Z-@@@-M1J) 4 dia. vinyl-insulated round cable with 3 conductors, Standard length: 0.3 m 4.5 11.2 Operation Indicator (orange) Operation selector Stability indicator (green) Sensitivity adjuster 10.8 2.8 Receiver Lens 7 dia. 3 2 M12x1 2.1 4 1 7.5 M8 Pre-wired Connector (E3Z-T@@K-M3J) 4 dia. vinyl-insulated round cable with 3 conductors, Standard length: 0.3 m 2 4 20 3 16.7 8 31 1 25.4 Emitter Lens 7 dia. 3 M8 Press-fit e-CON Pre-wired Connector Two, M3 5.9 1 2 3 4 4 dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter:1.1 mm), Standard length: 2 m Terminal No. Specifications 1 +V 2 --- 3 0V 4 Output 15 15.6 4 dia. vinyl-insulated round cable with 3 or 4 conductors, Standard length: 0.3 m, 0.5m, and 2m Clamp-type e-CON pre-wired connectors (E3Z-@6@-ECON-C) 6 1 2 3 4 15.8 18 4 dia. vinyl-insulated round cable with 3 conductors, Standard length: 2 m Retro-reflective Models Connector Models E3Z-R66 E3Z-B66 E3Z-R86 E3Z-B86 E3Z-D66 E3Z-B67 E3Z-D86 E3Z-B87 E3Z-D67 E3Z-L68 E3Z-D87 E3Z-L88 E3Z-L66 E3Z-L86 11.2 4.5 7.5 Operation Indicator (orange) Operation selector Stability indicator (green) 10.8 2.1 Receiver Lens 7 dia. 2.8 Sensitivity adjuster 20 3 16.7 31 8 25.4 Emitter Lens 7 dia. 10.4 Two, M3 M8 connector 9.75 Terminal No. Specifications 1 +V 2 --- 3 0V 4 Output Note: The lens for the E3Z-D@1/D@6/L@@/B@@ is red. The lens for the E3Z-D@2/D@7 is black. 17 E3Z e-CON Connector Configurations Wiring method Sensor connectors Press-fit 37104-3122-000FL (made by Sumitomo 3M) Clamp XN2A-1430 (made by OMRON) Accessories (Order Separately) Slits E39-S65A E39-S65B E39-S65C 10.4 Slits E39-S65D E39-S65E E39-S65F 20.2 10.4 A 20.2 A 12.7 12.7 32.2 10 32.2 0.2-mm-thick 0.2-mm-thick Model E39-S65A E39-S65B E39-S65C Slits E39-L44 Size A 0.5 dia. 1.0 dia. 2.0 dia. Material Model E39-S65D E39-S65E E39-S65F SUS301 stainless steel Slits E39-L104 (Mounting dimensions) Size A 0.5 1.0 2.0 1 7.0 14 6.7 R20 26.2 3 23.2 18 SUS301 stainless steel (Mounting dimensions) 19.5 14.1 8.7 Material 6 17.8 12.4 4.5 29 39 36 20 21.5 1.8 8.8 26.6 16.2 3 10 31.2 27 Mounting Brackets Refer to E39-R for details. Sensor I/O Connectors Refer to XS2@ and XS3@ for details. 18 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2011.8 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2011 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: E3Z-B61 5M E3Z-B62 5M E3Z-D61 0.5M E3Z-D61 5M E3Z-D61K 2M E3Z-D61K-M3J 0.3M E3Z-D61-M1J 0.3M E3Z-D62 0.5M E3Z-D62 5M E3Z-D62K 2M E3Z-D62K-M3J 0.3M E3Z-D62-M1J-1 0.3M E3Z-D62-M3J 0.3M E3ZD81 0.5M E3Z-D81K 2M E3Z-D81K-M3J 0.3M E3Z-D82 0.5M E3Z-D82 5M E3Z-D82K 2M E3Z-D82K-M3J 0.3M E3Z-D82-M1J-1 0.3M E3Z-L61 0.5M E3Z-L61 5M E3Z-L61-M1J 0.3M E3Z-L81 0.5M E3Z-L81 5M E3Z-LS61 5M E3Z-LS61K-M1J-EX 0.3M E3Z-LS61-M1J 0.3M E3Z-R61 0.5M E3Z-R61 5M E3Z-R61K 2M E3Z-R61-M3J 0.3M E3Z-R61-M5J 0.3M E3Z-R81 0.5M E3Z-R81-C1 E3Z-R81K 2M E3Z-R81K-M3J 0.3M E3Z-R81-M1J 0.3M E3Z-T61 0.5M E3Z-T61K 2M E3Z-T61K-M3J 0.3M E3Z-T61-M1J 0.3M E3Z-T61-M1J-1 0.3M E3Z-T61-M3J 0.3M E3Z-T62 2M E3Z-T67 E3Z-T81 0.5M E3Z-T81K 2M E3Z-T81K-M3J 0.3M E3Z-T81-L 2M E3Z-T81-M1J E3Z-T81-M1J-1 0.3M E3Z-T82 2M E3Z-T87 E3Z-B61-S0SBW-03 E3Z-D62-M1J 0.3M E3Z-G62-M1J 0.3M E3Z-G82-M1J 0.3M E3Z-L81M1J-1 0.3M E3Z-LL63 2M E3Z-LL81 2M E3Z-LL81-M1J 0.3M E3Z-LL83 2M E3Z-LR81-M1J 0.3M E3Z-LS81-M1J 0.3M E3Z-LS81-M3J 0.3M E3Z-LT61-L-M1J 0.3M E3Z-R61-M1J 0.3M E3Z-R61-M1J-1 0.3M E3Z-T61A-D 2M E3ZT61A-L 2M E3Z-T61A-M1J 0.3M E3Z-T81A-M1J 0.3M E3Z-T81C-G0SRD-CN E3Z-T81C-G0SRL-CN E3Z-T81-DM1J-1 0.3M E3Z-T81-L-M1J-1 0.3M E3Z-R81 5M