https://www.phoenixcontact.com/us/products/2864273
12/15/2020Page4/8
Resistance thermometer measuring transducer-MINI MCR-SL-PT100-UI-
NC-2864273
Technical data
General
Housing material PBT
Mounting position any
Assembly instructions The T connector can be used to bridge the supply voltage. It can be
snapped onto a 35 mm DIN rail according to EN 60715.
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2
EMC data
Designation Electromagnetic RF field
Standards/regulations EN61000-4-3
Typical deviation from the measuring range final value 10 %
Designation Fast transients (burst)
Standards/regulations EN61000-4-4
Typical deviation from the measuring range final value 10 %
Designation Conducted interferences
Standards/regulations EN61000-4-6
Typical deviation from the measuring range final value 10 %
Standards and Regulations
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Connection in acc. with standard CUL
Standards/regulations EN 61000-4-2
Designation Electromagnetic RF field
Standards/regulations EN61000-4-3
EN61000-4-4
EN61000-4-5
Designation Conducted interferences
Standards/regulations EN61000-4-6
Electrical isolation Basic insulation according to EN 61010
Conformance CE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA/Canada UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5
GL GL EMC 2 D
Conformance/approvals