The Best Relaytion FP2 Relay FP2 Relay 2 pole telecom / signal relay Through Hole Type (THT) Polarized. Relay types: non-latching with1 coil latching with 1 coil latching with 2 coils Features - Telecom / signal relay (dry circuit, test access, ringing) - Slim line 14 x 9 mm, 0.550 x 0.354 inch - Switching current 2 A - 2 changeover contacts (2 form C / DPDT) - Bifurcated contacts - High sensitivity results in low nominal power consumption 80 mW for high sensitive, 140 mW for sensitive version - High mechanical shock resistance up to 300 G functional up to 1500 G survival Typical applications - Communications equipment Linecard application - analog, ISDN, xDSL, PABX Voice over IP - Office and business equipment - Measurement and control equipment - Consumer electronics Set top boxes, HiFi - Medical equipment UL 508 File No. E111441 CECC 61811-53-001 QC 160503-CH0001 2 FP2 Relay Dimensions THT mm L W H T T1 T2 Tw S 14.02 0.08 9.02 0.08 5 0.1 3.2 + 0.3 N/A 7.62 0.1 0.5 0.25+0.05 inch 0.574 0.008 0.035 0.003 0.196 0.004 0.125 + 0.011 N/A 0.3 0.004 0.020 0.009+0.002 THT Version Mounting hole layout View onto the component side of the PCB (top view) Basic grid 2.54 mm Terminal assignment Relay - top view Non-latching type, not energized condition Latching type, reset condition latching, 2 coils reset condition 3 FP2 Relay Coil Data (values at 23C) Nominal voltage Unom Operate/set voltage range Minimum voltage UI Vdc Maximum Release/ reset voltage Minimum Nominal power consumption Resistance Vdc mW W / 10 % Relay Code voltage UII Vdc Vdc non-latching 1 coil 3 4.5 5 6 9 12 24 48 2.1 3.15 3.5 4.2 6.3 8.4 16.8 33.6 6.8 10.3 11.4 13.7 20.4 27.3 45.7 67.5 0.30 0.45 0.50 0.60 0.90 1.20 2.40 4.80 140 140 140 140 140 140 200 300 64 145 178 257 574 1028 2880 7680 D 3006 D 3004 D 3009 D 3005 D 3010 D 3002 D 3012 D 3013 2.25 3.38 3.75 4.5 6.75 9.00 18.00 36.00 9.0 13.5 15.0 18.0 27.1 36.1 54.7 72.5 0.3 0.45 0.5 0.6 0.9 1.2 2.4 4.8 80 80 80 80 80 80 140 260 113 253 313 450 1013 1800 4114 8882 D 3021 D 3022 D 3023 D 3024 D 3025 D 3026 D 3027 D 3028 2.25 3.375 3.75 4.5 6.75 9.00 18.00 8.1 12.1 13.5 16.2 24.2 29.0 47.5 2.25 3.375 3.75 4.50 6.75 9.00 18.00 100 100 100 100 100 100 150 90 203 250 360 810 1440 3840 D 3041 D 3042 D 3043 D 3044 D 3045 D 3046 D 3047 2.1 3.15 3.5 4.2 6.3 8.4 16.8 5.7 8.6 9.5 11.4 17.1 22.6 33.7 2.1 3.15 3.5 4.2 6.3 8.4 16.8 200 200 200 200 200 200 200 45 101 125 180 405 720 1920 D 3061 D 3062 D 3063 D 3064 D 3065 D 3066 D 3067 non-latching 1 coil high sensitive version 3 4.5 5 6 9 12 24 48 latching 1 coil 3 4.5 5 6 9 12 24 latching 2 coils 3 4.5 5 6 9 12 24 Further coil versions are available on request. 4 FP2 Relay UI = Minimum voltage at 23 C after pre-energizing with nominal voltage without contact current UII = Maximum continous voltage at 23 The operating voltage limits UI and UII depend on the temperature according to the formula: UI tamb = KI * UI and UII tamb = KIl * UIl 23 C tamb = Ambient temperature UI tamb = Minimum voltage at ambient temperature, tamb UII tamb = Maximum voltage at ambient temperature, tamb kI, kII 23 C = Factors (dependent on temperature), see diagram Ambient temperature tamb [C] Contact Data Number of contacts and type 2 changeover contacts Contact assembly Contact material Limiting continuous current at max. ambient temperature Maximum switching current Maximum swichting voltage Bifurcated contacts Silver-nickel, gold-covered 2A 2A 220 Vdc 250 Vac 60 W, 62.5 VA < 10 mV 100 mV < 50 mW min. 2.5 x 106 operations min. 2.0 x 106 operations min. 1.0 x 105 operations min. 1.0 x 105 operations min. 3.0 x 105 operations typ. 108 operations 220 Vdc / 0.24 A - 60 W 125 Vdc / 0.24 A - 30 W 250 Vac / 0.25 A - 62.5 VA 125 Vac / 0.5 A - 62.5 VA 30 Vdc / 2 A - 60 W Maximum switching capacity Thermoelectric potential Minimum switching voltage Initial contact resistance / measuring condition: 10 mA / 20 mV Electrical endurance at contact application 0 (30 mV/ 10 mA) at cable load open end at 125 Vdc / 0.24 A - 30 W at 250 Vac / 0.25 A - 62.5 VA at 24 V / 1.25 A - 30 W Mechanical endurance UL contact ratings Insulation Insulation resistance at 500 VDC Dielectric test voltage (1 min) between coil and contacts between adjacent contact sets between open contacts > 109 W 1000 Vrms 1000 Vrms 750 Vrms Surge voltage resistance according IEC (10 / 700 ms) between coil and contacts between adjacent contact sets between open contacts according to FCC 68 (10 / 160 ms) between coil and contacts between adjacent contact sets between open contacts 1500 V 1500 V 1500 V 1500 V 1500 V 1500 V 5 FP2 Relay High Frequency Data Capacitance between coil and contacts between adjacent contact sets between open contacts max. 4 pF max. 1 pF max. 1 pF RF Characteristics Isolation at 100 / 900 MHz Insertion loss at 100 / 900 MHz V.S.W.R. at 100 / 900 MHz -40.2 dB / -22.3 dB -0.03 dB / -0.25 dB 1.01 / 1.07 General data 3 ms / 4 ms 3 ms / 4 ms 1 ms / 3 ms 3 ms / 4 ms 1 ms / 5 ms 50 operations/s -55 C ... +85 C Operate time at Unom typ. / max. Reset time (latching) at Unom , typ. / max. Release time without diode in parallel (non-latching), typ. / max. Release time with diode in parallel (non-latching), typ. / max. Bounce time at closing contact, typ. / max. Maximum switching rate without load Ambient temperature Thermal resistance Maximum permissible coil temperature Vibration resistance (function) < 165 K/W 110 C 20 G 10 to 500 Hz 50 G (function) 1500 G (damage) immersion cleanable, IP 67 / RT III application time 20 s, no burning or glowing any Ultrasonic cleaning is not recommended max. 2 g 260 C / 10 s Shock resistance, half sinus, 11 ms Degree of protection / Environmental protection Needle flame test Mounting position Processing information Weight (mass) Resistance to soldering heat All data refers to 23 C unless otherwise specified. Packing Tube for THT version - 50 relays per stick, 1000 relays per box 6 FP2 Relay Ordering Information Relay Code D3002 D3004 D3005 D3006 D3009 D3010 D3012 D3013 D3021 D3022 D3023 D3024 D3025 D3026 D3027 Tyco Part Number 0-1462033-5 0-1462033-9 1-1462033-1 1-1462033-3 1-1462033-4 2-1462033-1 2-1462033-2 2-1462033-6 3-1462033-2 3-1462033-3 3-1462033-4 3-1462033-5 3-1462033-6 3-1462033-7 3-1462033-8 Relay Code D3028 D3041 D3042 D3043 D3044 D3045 D3046 D3047 D3061 D3062 D3063 D3064 D3065 D3066 D3067 7 Tyco Part Number 3-1462033-9 4-1462033-0 4-1462033-1 4-1462033-2 4-1462033-3 4-1462033-4 4-1462033-5 4-1462033-6 4-1462033-7 4-1462033-8 4-1462033-9 5-1462033-0 5-1462033-1 5-1462033-4 5-1462033-6 FP2 Relay IM Relays D2n Relays 4th generation slim line - low profile polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 1.5... 24 V, coil power consumption of 140... 200 mW, latching relays with 1 coil 100 mW. The IM relay is available as through hole and surface mount type (J-Legs and Gull Wings) and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills the Bellcore requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The IM relay is CECC/IECQ approved and certified in accordance with IEC/EN 60950 and UL1950. Dimensions approx. 10 x 6 mm board space and 5.65 mm height. 2nd generation non polarized 2 c/o relay for telecom and various other applications. Nominal voltage range from 3 ... 48 V, coil power consumption from 150 .... 500 mW. The D2n relay is capable to switch currents up to 3 A. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 20 x10 mm board space and 11,5 mm height. P1 Relays Extremely sensitive, polarized 1 c/o relay with bifurcated contacts for a wide range of applications, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power consumption 65 mW, latching relays with 1 coil 30 mW. The P1 relay is available as through hole or surface mount type and capable to switch currents up to 1 A. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 13 x 7,6 mm board space and 7 mm height for THT or 8 mm height for SMT version. P2 Relays 3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power consumption 140 mW, latching relays with 1 coil 70 mW. The P2 Relay is available as through hole or surface mount type and capable to switch currents up to 5 A. Dielectric strength fulfills the Bellcore requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 15 x 7,5 mm board space and 10 mm height. W11 Relays Low cost, non polarized 1 c/o relay for various applications. Nominal voltage range from 3 ... 24 V, coil power consumption 450 mW, sensitive versions 200 mW. The W11 relay is capable to switch currents up to 3 A. Dielectric strength 1000 Vrms. Dimensions approx. 15,6 x 10,6 mm board space and 11,5 mm height. FX Relays 3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the high sensitive version, 140... 300 mW for the standard version, latching relays with 1 coil 100 mW. The FX2 relay is available as through hole type and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills the Bellcore requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The FX2 is CECC/ IECQ approved and certified in accordance with IEC/EN 60950 and UL1950. Dimensions approx. 15 x 7,5 mm board space and 10,7 mm height. Reed Relays High sensitive, non polarized relay for telecom and various other applications, available with 1 n/o, 2 n/o or 1c/o contacts. Nominal voltage range from 5 ... 24 V, coil power consumption 50...280 mW for 1 n/o and 125 ... 280 mW for 2 n/o or 1 c/o versions. Reedrelays are available in DIP or SIL housing and capable to switch currents up to 0,5 A. Integrated diode and/or electrostatic shield optional. Dielectric strength 1500 Vdc. Dimensions approx. 19,3 x 7 mm board space and 5 ... 7,5 mm height for DIP or 19,8 x 5 mm board space and 7,8 mm height for SIL version. FT2 / FU2 Relays 3rd generation non polarized, non latching 2 c/o telecom relay with bifurcated contacts. Nominal voltage range from 3 ... 48 V, coil power consumption 200 ... 300 mW. Most sensitive 48 V relay. Available as through hole and surface mount type. Dielectric strength fulfills the Bellcore requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The FT2/FU2 is CECC/IECQ approved and certified in accordance with IEC/EN 60950 and UL1950. Dimensions approx. 15 x 7,5 mm board space and 10 mm height. Cradle Relays Extremely reliable and mature relay family of 1st generation for various signal switching applications. Available as non polarized, polarized / latching and relay with AC coil. The benefit is the possibility of combining various contact sets from 1 up to 6 poles, single and bifurcated contacts, different contact materials with a coil voltage range from 1,5 Vdc to 220 Vac. Cradle relays are available as dust protected and hermetically sealed versions, with plug in or solder terminals and are capable to switch currents up to 5 A. Forcibly guided (linked) contact sets optional. Dielectric strength 500 Vrms. Dimensions from approx. 19 x 24 to 19x35 mm board space and 30 mm height. FP1 Relays 3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the high sensitive version, 140... 300 mW for the standard version, latching relays with 1 coil 100 mW.. The FP1 Relay is available as through hole type and capable to switch loads up to 30 W/62,5 VA. Dielectric strength fulfills FCC part 68 (1,5 kV - 10 / 160 s). The FP2 is CECC/IECQ approved. Dimensions approx. 14 x 9 mm board space and 5 mm height. Other Relays We offer a variety of different relay families for maintenance and replacement purposes. These relays are up to 60 years old now, such as Card Relay SN (V23030 / V23031 series), Small General Purpose Relay (V23006 series), Small Polarized Relay (V23063 ... V23067 and V23163 ... V23167 series). Accessories like sockets, hold down springs, etc. optional. MT2 / MT4 2nd generation non polarized, non latching 2 c/o and 4 c/o telecom and signal relay with bifurcated contacts. Nominal voltage range from 4.5 ... 48 V, coil power consumption 150/200/300/400 and 550 mW, and 300 mW (MT4). Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s) for both and the Bellcore requirements according GR 1089 (2,5 kV - 2 / 10 s) the MT4 only. Dimensions MT2 approx. 20 x 10 mm board space and 11 mm height, MT4 approx. 20 x15 mm board space and 11 mm height. HF3 Relay High performance low cost RF relay with excellent RF characteristics. Available with an impedance of 50 and 75 Ohm. Suitable for frequencies up to 3 GHz. Actually smallest RF relay available combining small size, excellent RF performance and SMD solderability. Available as non latching or latching relay with 1 or 2 coils and a nominal coil voltage range from 3 ... 24 V, coil power consumption 140 mW, latching relays with 1 coil 70 mW. Dimensions 14.6 x 7.3 x 10 mm. 8 Tyco Electronics AXICOM Ltd. Seestrasse 295 - P.O. Box 220 CH-8804 Au-Wadenswil / Switzerland Phone +41 1 782 9111 Fax +41 1 782 9080 E-mail: axicom@tycoelectronics.com Tyco Electronics AMP GmbH Paulsternstrasse 26 D-13629 Berlin / Germany Phone +49 30 386 38260 Fax +49 30 386 38569 E-mail: axicom@tycoelectronics.com February 2003 Tyco Electronics Corporation POB 3608, Harrisburg, PA 17105, USA Phone +1 800-522-6752 Rev. 2.06 Tyco Electronics EC Trutnov s.r.o. Komenskeho 821 CZ-541 01 Trutnov / Czech Republic E-mail: axicom@tycoelectronics.com 9