Input Voltage: 85-132/180-264 VAC, 47-63 Hz, 1 phase
Input Current: <3.2A RMS @ 115 VAC @ full load
<1.6A RMS @ 230 VAC @ full load
Inrush Current: <25A, pk @ 132 VAC @ cold start
<50A, pk @ 265 VAC @ cold start
Harmonic Distortion: Meets EN61000-3-2 for Class A
EMI Filtering: Meets CISPR 11 and 22 and FCC Part 15
Class B (conducted)
Input Protection: Internal AC line fuse; 250 VAC, 6.3A
Output Power: 150W with 15CFM air; 80W Convection
Line Regulation: ± 0.3%
Load Regulation: ± 0.5%
PARD: <1% or 50mV;
20MHz bandwidth
Hold-up Time: 20 ms @ full load (120 VAC)
Output Polarity: Output is floating
Minimum Load: 0% of rated load
Transient Response: 3% for 25% load change @ 1A/µs;
50% duty cycle 50/60 Hz
Output Rise Time: <100 ms (10% to 90%)
Current Limit: 105-130% of rated current; Hiccup
Remote Sense: Compensates for up to 250mV of total cable
drop
Remote On/Off: Optional
Thermal Shutdown Standard
DC OK: Standard; Open Collector
Turn-on Delay: <1 second after application of AC Input
Stability: <0.1% for 8 hours
after 1/2-hour warm up
Isolation: >20 MΩ @ 100 VDC between output
terminals and chassis ground
AC Power Fail: TTLLOW logic “0” at least 2 ms before
output drops 5%; Open Collector
Overvoltage Protect: Factory set, 125% ±5%,
cycle AC to reset
Reverse Voltage: Output has reverse voltage protection;
Reverse current limited to 100% of output
rating
Efficiency: Up to 85%
MTBF: MIL-STD-HDBK 217E
>200,000 hours @ 25°C
Highly Accelerated Life Testing
Electrical Specifications
Continuous
Voltage Voltages Current
Codes (Volts) (Amps)
-2 3.3 30
-3 5.0 30
-4 12.0 12.5
-5 15.0 10.5
-6 24.0 6.5
-7 28.0 5.5
-8 36.0 4.5
-9 48.0 3.5
* Consult factory for other voltages and OEM quantities.
Note: Standard models are shown bold
Available Voltage Outputs*
PAS150
Model
150 Wattsmax output power
Power Factor Correction
Single Output
Switch Mode Power Supply
H.A.L.T.
TESTED
Highly
Accelerated
Life
Testing
PART # STRUCTURE:
MODEL - VOLTAGE CODE - OPTION CODES (See back)
- V1 -
PAS150 - X - ABC....
Example: Part Number PAS150-4-CF= 150W Power Factor Corrected, 12V @ 12.5A with a fan assembly and power fail invert.
See 3rd page for PAS150 CODE TABLE AND AVAILABLE OPTIONS.
Physical Specifications
Dimensions: (HxWxL) 1.5" x 4.0" x 6"
Operating Temp: 0 to 70°C; rated power to 50°C
derate linearly to 50% at 70°C.
Relative Humidity: 5% to 90%, non-condensing
Storage: -50 to 85°C/20-90% RH
Altitude: 6561
40,000' storage
Options
12V@0.5A Aux./Fan Drive (A) Droop Current Share ±10% (B)
Fan Assembly (C) DC OK Invert (E)
PF Invert (F) Field-Configurable (G)
Single Wire Current Share ±5% (I) Square Current Limit (J)
Molex Connector (K) Metric Mounting (M)
OR-ing Diode (O) Remote On/Off (R)
Remote On/Off Invert (S)
Model
Safety Compliance
IEC / EN / UL / CSA 60950-1
CE Declaration to Low Voltage Directive 2006/95/EC and
RoHS Directive 2011/65/EU
Surge & ESD Test Levels
EN61000-4-5 Level 3 EN61000-4-2 Level 2
EN61000-3-2 for Class A EN61000-4-2 Level 3 (Air Only)
EN61000-4-4 Level 3 EN61000-4-11
Meets Class B conducted limits per CISPR 11/22 and 47 CFR 15 subpt B
FM 32227
© Copyright 2011 TAMURA CORPORATION OF AMERICA. Specifications subject to change without notice.
TAMURA CORPORATION OF AMERICA
1040 South Andreasen Drive, STE. 100 Escondido, CA 92029-1951
(951) 699-1270 / Fax: (951) 676-9482
(800) 472-6624
www.tamuracorp.com
PAS150
Item 40614 Rev A
PRODUCT CODE TABLE
Page 1 of 1 38698 Rev B
PAS150 Series Power Supply
Standard Models Tailored Models Custom Models
PAS150-X-Y1….Yn PAS150-60ZZZ PAS150-61ZZZ
Voltage and Current Ratings Standard Options
X
Codes Volts Amps “Y” Code Descriptions
A 12Vdc, 0.5A Auxiliary Output**
B Droop Share*
C Fan Assembly**
E DCOK Invert
F PF Invert
G Field configurable options – B, I, and J
I Single Wire Share*
J Square Current Limit
K Molex Connector, 7A max. (#8 studs standard)
M Metric Mounting
O ORing Diode
R Remote On/Off (closed is OFF)
S Remote On/Off Invert (open is OFF)
*Includes Option J
**Options A and C are not available together
Tailored Units (no safety changes)
-------------------------
60ZZZ, where ZZZ = Factory Assigned Number
Harnesses Added, Special test data ,Etc.
1
2
3
4
5
6
7
8
9
Not Available
3.3 30.0
5.0 30.0
12.0 12.5
15.0 10.5
24.0 6.5
28.0 5.5
36.0 4.5
48.0 3.5
Custom Units (safety critical changes)
-------------------------
61ZZZ, where ZZZ = Factory Assigned Number