Instruction Sheet 408-- 2786 Crimping Die Assemblies 220189- [ ] and 58330- 1 03 MAY 11 Rev J PROPER USE GUIDELINES Cumulative Trauma Disorders can result from the prolonged use of manually powered hand tools. Hand tools are intended for occasional use and low volume applications. A wide selection of powered application equipment for extended-- use, production operations is available. Die Retaining Screws Stationary Jaw Indenter Die PRO-- CRIMPER* III Frame Assembly 354940-- 1 (Ref) Crimping Die Assembly (Ref) Moveable Jaw Anvil Die Center Contact Crimping Chamber Ferrule Crimping Chamber DIE ASSEMBLY PART NUMBER CONNECTOR BASE PART NUMBER 220189--1, 220189--2 227000, 227079, 228980, 228979 220189--3 58330--1 225395, 225396, 225397, 225398 227079 Figure 1 1. INTRODUCTION Reasons for reissue are provided in Section 8, REVISION SUMMARY. This instruction sheet covers the use and maintenance of Crimping Die Assemblies listed in Figure 1. The dies are used in PRO--CRIMPER III Frame Assembly 354940--1 to crimp 50-- and 75--Ohm BNC, and 50--Ohm TNC Dual--Crimp Connectors onto various size cable. Refer to Figure 1 for a list of connectors that are compatible with the die assemblies. Refer to Catalog 82074 for additional product part number information. For part numbers not listed, contact TE Connectivity Product Engineering for recommendations. E2011 Tyco Electronics Corporation, a TE Connectivity Ltd. Company All Rights Reserved *Trademark NOTE i All dimensions in this document are in millimeters [with inches in brackets]. Figures and Illustrations are for reference only and are not drawn to scale. 2. DESCRIPTION Each die assembly consists of an indenter die and an anvil die, which when mated form two crimping chambers. The large crimping chamber crimps the connector ferrule and the small crimping chamber crimps the connector center contact. Each die is held in the tool by a single screw. See Figure 1. TOOLING ASSISTANCE CENTER 1--800--722--1111 PRODUCT INFORMATION 1--800--522--6752 This controlled document is subject to change. For latest revision and Regional Customer Service, visit our website at www.te.com TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or Company names may be trademarks of their respective owners. 1 of 5 LOC B 408- 2786 3. DIE INSTALLATION To be sure that the die assembly is properly aligned during installation, proceed as follows: 1. Slide the die assembly into the partially--opened tool jaws. The anvil die must be installed in the movable jaw of the tool and the indenter in the stationary jaw. The center contact crimping chamber must be toward the front of the tool as shown in Figure 1. 2. Insert, but do not completely tighten, the die retaining screws. 3. Close the tool jaws and carefully align the dies so that the anvil die enters the indenter die. Once the anvil has entered the indenter, place a copper bus bar (1.57+0.05 mm [.062+.002 in.] diameter) into the center contact crimping chamber of the die assembly. 4. With bus bar in place, close the tool jaws completely. Hold the tool handles together and tighten the die retaining screws with the appropriate screwdriver. Crimping the Center Contact Center Contact Flange Butt Against Edge of Die Anvil Die Stripped Cable Flange on End of Center Contact Cross--Sectional View Edge of Die 4. CRIMPING PROCEDURE NOTE i For detailed information on cable selection, cable strip lengths, and proper assembly of the connector, refer to the instructions provided with the connector. Select the appropriate die assembly that is compatible with the connector being used. Proceed as follows: Figure 2 4.2. Ferrule (Figure 3) 1. Insert the crimped center contact into the connector body until the cable dielectric butts against the dielectric inside the connector body. The flared braid must fit around the support sleeve of the connector body. 4.1. Center Contact (Figure 2) 1. Slide the ferrule onto the cable, then strip the cable to the proper dimensions. 2. Slide center contact onto center conductor of cable; then insert contact assembly into the center contact crimping chamber of the anvil die. See Figure 2. NOTE i Make sure that the flange on the end of the center contact butts against the edge of the die. Refer to the cross--sectional view in Figure 2. 3. Crimp the center contact by holding the cable in place; then close the tool handles until the ratchet releases. 4. Remove the crimped center contact assembly from the crimping dies. 2 of 5 Shoulder on Connector Body Butts Against Edge of Die Ferrule in Crimping Chamber on Anvil Die Figure 3 Rev J 408- 2786 2. Slide the ferrule forward over the braid until the ferrule butts against the shoulder on the connector body. 3. Place the ferrule in the ferrule crimping chamber of the anvil die so that the shoulder on the connector body butts against the edge of the die. See Figure 3. 4. Holding the assembly in place, close the tool handles until the ratchet releases. 5. Remove crimped assembly from the crimping dies. 5. CRIMP HEIGHT ADJUSTMENT (Figure 4) 4. When the dies are not in use, mate and store them in a clean, dry area. 6.2. Periodic Inspections Regular inspections should be performed by quality control personnel. A record of scheduled inspections should remain with the dies and/or be supplied to supervisory personnel responsible for the dies. Though recommendations call for at least one inspection per month, the inspection frequency should be based on amount of use, working conditions, operator training and skill, and established company standards. These inspections should be performed in the following sequence: Screwdriver The tool frame assembly ratchet mechanism features an adjustment wheel with numbered settings. If the crimp height is not acceptable, adjust the ratchet as follows: 1. Remove the lockscrew from the ratchet adjustment wheel. 2. With a screwdriver, adjust the ratchet wheel from the opposite side of the tool. 3. Observe the ratchet adjustment wheel. If a tighter crimp is required, rotate the adjustment wheel COUNTERCLOCKWISE to a higher--numbered setting. If a looser crimp is required, rotate the adjustment wheel CLOCKWISE to a lower--numbered setting. Ratchet Adjustment Wheel Lockscrew (Typ) Figure 4 4. Replace the lockscrew. 5. Make a sample crimp and measure the crimp height. If the crimp height is acceptable, secure the lockscrew. If the dimension is unacceptable, remove lockscrew and continue to adjust the ratchet, and again measure a sample crimp. 6. MAINTENANCE AND INSPECTION 6.1. Daily Maintenance It is recommended that each operator of the tool with the die assembly be made aware of, and responsible for, the following four steps of daily maintenance: 1. Remove dust, moisture, and other contaminants with a clean, soft brush, or a clean, soft, lint--free cloth. Do NOT use any objects that could damage the dies or tool. 2. Make sure that the proper die retaining screws are in place and secured. 3. Make certain that all surfaces are protected with a THIN coat of any good SAE 20 motor oil. Rev J A. Visual Inspection 1. Remove all lubrication and accumulated film by immersing the dies in a suitable commercial degreaser. 2. Make certain all die retaining screws and die components are in place and secured. If replacements are necessary, refer to Section 7, REPLACEMENT. 3. Inspect the crimp area for flattened, chipped, worn, cracked, or broken areas. If damage is evident, the dies must be replaced (see Section 7, REPLACEMENT). B. Gaging the Crimping Chamber This inspection requires the use of a plug gage conforming to the diameters provided in Figure 5. TE does not manufacture, or market, these gages. Proceed as follows: 1. Mate the dies until it is evident that they have bottomed. Hold the dies in this position by holding the tool handles closed with moderate pressure. 3 of 5 408- 2786 2. Align the GO element of the gage with the crimping chamber. Push the element straight into the chamber without using force. The GO element must pass completely through the crimping chamber as shown in Figure 5. 3. Align the NO--GO element with the crimping chamber and try to insert it straight into the chamber. The NO--GO element may start entry but must not pass completely through. See Figure 5. If the crimping chambers conform to the gage inspection, the dies are considered dimensionally correct and should be lubricated with a thin coat of any good SAE 20 motor oil. If not, the dies must be replaced before returning them to service. 7. REPLACEMENT Parts listed in Figure 6 are customer--replaceable. A complete inventory can be stocked and controlled to prevent lost time when replacement of parts is necessary. Order replacements through your local TE Representative, or call 1--800--526--5142, or send a facsimile of your purchase order to 1--717--986--7605, or write to: CUSTOMER SERVICE (38--35) TYCO ELECTRONICS CORPORATION P.O. BOX 3608 HARRISBURG, PA 17105--3608 8. REVISION SUMMARY S Updated document to corporate requirements. For additional information concerning the use of the plug gage, refer to Instruction Sheet 408--7424. GO Dia Suggested Plug Gage Design for Center Contact Crimping Chamber NO-- GO Dia GO Dia Suggested Plug Gage Design W for Ferrule Crimping Chamber NO-- GO Dia R "GO" element must pass completely through the die closure. Crimping Chamber GO Element NO-- GO Element "NO-- GO" element may enter partially, but must not pass completely through the die closure. GAGE ELEMENT DIAMETER (mm [in.]) DIE ASSEMBLY PART NO. CRIMPING CHAMBER CENTER CONTACT FERRULE GO NO-- GO GO NO-- GO RADIUS ``R" (Max) WIDTH ``W" (Max) 220189--1 1.207--1.214 [.0475--.0478] 1.359--1.367 [.0535--.0538] 5.156--5.164 [.2030--.2033] 5.408--5.410 [.2129--.2130] 2.51 [.099] 5.03 [.198] 220189--2 1.054--1.062 [.0415--.0418] 1.181--1.189 [.0465--.0468] 5.969--5.977 [.2350--.2353 6.220--6.223 [.2449--.2450] 2.92 [.115] 5.84 [.230] 220189--3 1.925--1.928 [.0758--.0759] 1.984--1.986 [.0781--.0782] 5.405--5.408 [.2128--.2129] 5.667--5.669 [.2231--.2232] 2.64 [.104] 5.28 [.208] 58330--1 1.029--1.036 [.0405--.0408] 1.181--1.189 [.0465--.0468] 4.191--4.199 [.1650--.1653] 4.442--4.445 [.1749--.1750] 2.03 [.080] 4.06 [.160] Figure 5 4 of 5 Rev J 408- 2786 30.48 mm [1.20 in.] 11.89 mm [.468 in.] 2 34.80 mm [1.37 in.] 1 WEIGHT: 227 g [8 oz] CUSTOMER-- REPLACEABLE PARTS DIE ASSEMBLY PART NO. ANVIL (Item 1) INDENTER (Item 2) 220189--1 310498--2 310497--2 220189--2 310498--4 310497--4 220189--3 310567--1 310568--1 58330--1 313764--1 313763--1 Figure 6 Rev J 5 of 5 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TE Connectivity: 58330-1 220189-1 220189-2 220189-3