OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue B.2 05/08
Page 4 of 7
Photologic® Slotted Optical Switch
OPB960, OPB970, OPB980, OPB990 Series
For parts built after 2004
OPTEK Technology is TS 16949:2002 certified, any changes will be consistent with TS 16949:2002 procedures.
Electrical Characteristics (TA = -40°C to + 70°C, VCC = 4.5V to 16.0V unless otherwise noted)
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
Input Diode (See OP240 for additional information)
VF Forward Voltage - - 1.7 V IF = 20 mA, TA = 25° C
IR Reverse Current - - 100 µA VR = 2.0 V, TA = 25° C
Output Photologic® Sensor (See OPL560 series for additional information)
VCC Operating D.C. Supply Voltage 4.5 - 16.0 V -
VR(P-P)
Peak-to-Peak VCC voltage ripple
necessary to cause false triggering - - 2.0 V f = DC to 50 MHz
ICC Supply Current - 8 12 mA VCC = 4.5V to 16.0V
VOL
Low Level Supply Voltage:
Totem-Pole
Open-Collector
Inverted Totem-Pole
Inverted Open-Collector
- - 0.4 V
IOL = 12.8 mA, IF = 0 mA
IOL = 12.8 mA, IF = 0 mA
IOL = 12.8 mA, IF = 15 mA(5)
IOL = 12.8 mA, IF = 15 mA(5)
VOH
High Level Output Current:
Totem-Pole
Open-Collector
Inverted Totem-Pole
Inverted Open-Collector
VCC-2.1 - - V
IOH = -1 µA, IF = 15 mA
IOH = -1 µA, IF = 15 mA
IOH = -1 µA, IF = 0 mA(5)
IOH = -1 µA, IF = 0 mA(5)
IOH
High Level Output Current:
Totem-Pole
Open-Collector
Inverted Totem-Pole
Inverted Open-Collector
- - 100 µA
VOH = 30 V, IF = 15 mA, TA = 25° C
VOH = 30 V, IF = 15 mA, TA = 25° C
VOH = 30 V, IF = 0 mA(5), TA = 25° C
VOH = 30 V, IF = 0 mA(5), TA = 25° C
IF(+) LED Positive-Going Threshold Current - - 15 mA VCC = 5.0 V, TA = 25° C
IF(+), IF(-) Hysteresis - 2.0 - V VCC = 5.0 V
IOS
Short Circuit Output Current:
Totem-Pole
Inverted Totem-Pole
-15
-
-60
mA
VCC = 5.25 V, IF = 15 mA, VOH = GND
VCC = 5.25 V, IF = 0 mA(5), VOH = GND
trtr Output Rise Time, Output Fall Time - 70 - ns VCC = 5 V, TA = 25° C, IF = 0 or 15 mA
TPLH, TPHL Propagation Delay Low-High,
Propagation High-Low - 5.0 - µs
RL = 8TTL loads (Totem Pole),
RL = 360 Ω (Open-Collector)
Notes:
(1) The OPB880/OPB890 series switches are terminated with 24” (609.600 mm) of 7-strand 26 AWG, UL approved insulated wire on each
terminal. Insulation colors and functions are: Anode (red), cathode (black), VCC (white), output (blue), and ground (green). Custom
wire lengths and/or colors are available. Contact your local representative or OPTEK for details.
(2) Normal application would be with light source blocked, simulated by IF = 0 mA.
(3) All parameters are tested using pulse techniques.