ECE60 Series AC-DC Power Supplies 60 Watts * Ultra Compact Size * Single Outputs from 3.3 to 48 V * Encapsulated * PCB & Chassis Mount Versions * <0.3 W No Load Input Power * -40 to +70 C Operation * Peak Load Capability * 3 Year Warranty Dimensions: The ECE60 series of compact encapsulated AC-DC power modules are available in both PCB & chassis mount versions offering exceptional power density of >10W/in3. Output voltages are available from 3.3 - 48 VDC and these "green power" modules offer high active mode efficiency and low no load power consumption. They also provide a peak load capability up to 130% of nominal power for up to 30s and a wide operating temperature range from -40 to +70C. ECE60: 3.60 x 1.50 x 1.10" (91.4 x 38.1 x 28.0 mm) ECE60-S: 4.45 x 1.57 x 1.12" (113.0 x 40.0 x 28.5 mm) Models & Ratings Output Power Output Current Output Voltage Nominal Peak (1) Efficiency (4) Model Number 33 W 3.3 V 10.00 A 13.00 A 79% 50 W 5.0 V 10.00 A 13.00 A 83% ECE60US05 60 W 9.0 V 6.67 A 8.67 A 87% ECE60US09 (2,3) ECE60US03 60 W 12.0 V 5.00 A 6.50 A 87% ECE60US12 60 W 15.0 V 4.00 A 5.20 A 88% ECE60US15 60 W 24.0 V 2.50 A 3.25 A 89% ECE60US24 60 W 36.0 V 1.67 A 2.17 A 88% ECE60US36 60 W 48.0 V 1.25 A 1.63 A 86% ECE60US48 Notes 1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal power. 2. Add suffix -S to model number to denote chassis mount with screw terminal type, e.g. ECE60US12-S. 3. A screw terminal version (-S) is available with DIN Clip attached. Add suffix `D', e.g. ECE60US24-SD. DIN Rail mounting clip is available as a separate item, order code ECE60 DIN CLIP. 4. Average of efficiencies measured at 25%, 50%, 75% & 100% load with 230 VAC input. Summary Characteristic Input Range Minimum Maximum Units 85 264 VAC 120 370 VDC No Load Input Power 1 Efficiency 79 Operating Temperature -40 Typical Notes & Conditions Derate load from 100% at 90 VAC to 90% at 85 VAC <0.3 W <0.5 W 3.3-9 V & 48 V versions 89 % See note 4 above +70 C Some specification parameters may not met below -25 C. Derate linearly from 100% load at +50 C to 50% load at 70 C. 87 EMC EN55022 Level B Conducted & Radiated, EN61000-4, EN61000-3 Safety Approvals EN60950-1, UL60950-1, CSA22.2 No. 234 per cUL www.xppower.com 12-36 V versions ECE60 Series AC-DC Power Supplies Input Characteristic Input Voltage - Operating Input Frequency Minimum Maximum Units 85 Typical 264 VAC 120 370 VDC 47 63 Hz Power Factor Derate load from 100% at 90 VAC to 90% at 85 VAC EN61000-3-2 class A compliant Input Current 0.6 No Load Input Power Inrush Current A rms At 230 VAC 0.3 W 12-36 V versions 0.5 W 3.3-9 V & 48 V versions A 115/230 VAC cold start at 25 C 25/50 Earth Leakage Current Input Protection Notes & Conditions Class II construction no earth Internal T2.5 A/250 VAC fuse Output Characteristic Minimum Output Voltage 3.3 Typical Initial Set Accuracy Minimum Load Maximum Units Notes & Conditions 48 VDC See Models and Ratings table 1 % 0 A Start Up Delay 2 s Start Up Rise Time 30 ms Hold Up Time 16 ms Line Regulation Load Regulation Transient Response Ripple & Noise Overvoltage Protection Overload Protection At full load and 115 VAC 0.5 % 2 % 1 % All other models 4 % Recovery within 1% in less than 500 s for a 25% load change 60 mV pk-pk 3.3-5 V versions, 20 MHz bandwidth 75 mV pk-pk 3.3-5 V `-S' versions, 20 MHz bandwidth, 0.1 F capacitor at output terminals 20 MHz bandwidth all other models ECE60US03/05-S 1 % pk-pk 195 216 % Vnom ECE60US03 models 115 140 % Vnom All other models 110 180 % 0.05 %/C Short Circuit Protection Trip & restart (hiccup mode) Temperature Coefficient General Characteristic Minimum Typical Maximum Units Efficiency 79 87 89 % Isolation 3000 VAC 100 Switching Frequency Power Density Weight See Models & Ratings table Input to Output kHz 10.1 Mean Time Between Failure Notes & Conditions W/in3 >300 kHrs MIL-HDBK-217F, +25 C GB 0.42 (191) lb (g) ECE60 0.44 (200) ECE60-S Environmental Characteristic Minimum Typical Maximum Units Operating Temperature -40 +70 C Storage Temperature -40 +85 C 95 %RH 3048 m Cooling Humidity Operating Altitude Vibration Notes & Conditions Some specification parameters may not met below -25 C. Derate linearly from 100% load at +50 C to 50% load at 70 C. Convection-cooled Non-condensing 2 g, 10 Hz to 500 Hz, 10 mins/cycle, 60 mins each cycle www.xppower.com 2 ECE60 Series AC-DC Power Supplies EMC: Emissions Phenomenon Test Level Standard Conducted EN55022 Class B Radiated EN55022 Class B Harmonic Current EN61000-3-2 Voltage Flicker EN61000-3-3 Criteria Notes & Conditions Class A EMC: Immunity Test Level Criteria EN61000-4-2 3 A Radiated EN61000-4-3 10 V/m 80% mod A EFT EN61000-4-4 3 A Surges EN61000-4-5 Installation Class 3 A Conducted EN61000-4-6 3 A Dips and Interruptions EN61000-4-11 DIP: 100% 10 ms DIP: 30% 500 ms INT: 100% 5000 ms A A B Phenomenon Standard ESD Notes & Conditions Safety Approvals Safety Agency Safety Standard UL UL60950-1, CSA 22.2 No.234 per cUL Notes & Conditions TUV EN60950-1 CB IEC60950-1 Mechanical Details ECE60 0.139 (3.54) 3.60 (91.4) ACN 1.50 (38.1) 1.18 (30.0) ECE60 Screw Terminal (-S) 0.50 (12.7) 0.18 (4.5) 4x o0.14 (4x o3.5) 0.44 (11.2) +Vo TOP VIEW 4.09 (104.0) ACN -Vo 1.57 (40.0) 0.159 (4.05) TOP VIEW ACL -Vo 0.84 (21.3) 1.20 +Vo (30.5) ACL 0.14 (3.55) 3.50 (89.7) 3.32 (84.3) 0.54 (13.8) 0.19 (4.8) 1 1.12 (28.5) 1.10 (28.0) 4x o 0.06 (o1.5) 0.24 (6.2) 0.4 (10.2) 0.10 (2.5) 4.45 (113.0) Optional DIN clip Notes 1. All dimensions in inches (mm). 2. Weight: ECE60: 0.42 lbs (191 g) ECE60-S: 0.44 lbs (200 g) 3. Tolerances: x.xx = 0.02 (x.x = 0.5), x.xxx = 0.01 (x.xx = 0.25) 3 www.xppower.com 12 May 17