G3M G3M
220
Characteristics
Item G3M-102PL-US
(-4)
G3M-202P(L)-US (-4)
G3M-203P (L) (-4) G3M-205P (L) (-4)
Operate time
1 ms max. (1/2 of load power source cycle + 1 ms max. for G3M-202P
, G3M-203P
, G3M-205P)
Release time
1/2 of load power source cycle + 1 ms max.
Output ON voltage drop
1.6 V (RMS) max.
Leakage current
2 mA max. (at 100
VAC)
2 mA max. (at 100
VAC)
5 mA max. (at 200
VAC)
1.5 mA (at 200 V
AC)
Insulation resistance
1,000 M
Ω
min. (at 500 VDC)
Dielectric strength
2,000 V
AC, 50/60 Hz for 1 min
2,500 V
AC, 50/60 Hz for 1 min
V
ibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Malfunction: 1,000 m/s
2
Ambient temperature
Operating: –30°
C to 80
°
C (with no icing or condensation)
Storage: –30°
C to 100
°
C (with no icing or condensation)
Ambient humidity
Operating: 45% to 85%
Weight
Approx. 15 g Approx. 25 g
Approved Standards
Approved
by UL
(Report No. E64562)
Approved by CSA
(Report No. LR35535)
Approved by TÜV
G3M-202P(L)-US(-4)
G3M-203P(L)(-4) G3M-202P(L)-US(-4)
G3M-203P(L)(-4) G3M-202P(L)-UTU(-4)
G3M-203P(L)-UTU(-4)
Engineering Data
Load current (A)
Ambient
temperature (
°C)
Load Current vs. Ambient Temperature Inrush Current Immunity
Non-repetitive
Reduce
the current to 1/2 or less if the
G3M is in repetitive operation.
Inrush peak current (A)
Energizing time (ms)
G3M-205P(L)(-4)
G3M-102PL-US(-4)
G3M-202P(L)-US(-4)
G3M-102PL–US(-4)
G3M-202P(L)-US(-4)
G3M-203P(L)(-4) G3M-203P(L)(-4)
G3M-205P(L)(-4)