For more Information
please call
1-800-Belden1
General Description:
24 AWG stranded (7x32) TC conductors, Datalene® insulation, twisted pairs, overall Beldfoil® (100%
coverage) + TC braid shield (65% coverage), 24 AWG stranded TC drain wire, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
624 7x32 TC - Tinned Copper
Total Number of Conductors: 12
Insulation
Insulation Material:
Insulation Trade Name Insulation Material Wall Thickness (in.)
Datalene® FPE - Foam Polyethylene 0.013
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1Beldfoil® Tape Aluminum Foil-Polyester Tape w/Shorting Fold 100
2 Braid TC - Tinned Copper 65
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
24 7x32 TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride 0.035
Overall Cable
Overall Nominal Diameter: 0.341 in.
Pair
Pair Color Code Chart:
Number Color
1White/Blue & Blue/White
2White/Orange & Orange/White
3White/Green & Green/White
4White/Brown & Brown/White
5White/Gray & Gray/White
6Red/Blue & Blue/Red
Mechanical Characteristics (Overall)
Operating Temperature Range: -30°C To +80°C
UL Temperature Rating: 80°C (UL AWM Style 2919)
Bulk Cable Weight: 54 lbs/1000 ft.
Max. Recommended Pulling Tension: 71.500 lbs.
Min. Bend Radius/Minor Axis: 3.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CM
CEC/C(UL) Specification: CM
AWM Specification: UL Style 2919 (30 V 80°C)
EU Directive 2011/65/EU (ROHS II): Yes