Datasheet
Valve Position Indicator
VPX Series
DESCRIPTION
Valve Position Indicator, VPX Series switches are built
especially for outdoor use in potentially hazardous
atmospheres. The switch enclosures are constructed to
withstand the pressure of an internal explosion. Flame paths
cool the exploded gases to a point less than the lowest safe
operating temperature of the surrounding gas. The VPX Series
versions equipped with the inductive proximity switches
has the Intrinsically Safe (IS) rating. Regardless of where the
equipment or machinery is designed, built or installed, the VPX
Series products carry global agency coverage.
The VPX Series switches have standard rugged die-cast
aluminum housing. The products housing is weather sealed
for outdoor use and comply with NEMA 4X requirement for
protection against corrosion, in addition to various NEMA
enclosure standards.
The product’s o-ring seals make the enclosure rain tight,
but are outside of required flame paths so explosion proof
requirements are maintained. The VPX Series switches
are available in multiple colors and angles, visible from all
directions. Unless special ordered, all basic switches operate
on clockwise and counterclockwise rotation.
DIFFERENTIATION
With numerous environmental ratings (Ingress Protection
and NEMA), the VPX Series is protected for all kinds of
outdoor conditions
VPX Series is certified flame-proof, explosion-proof and
Intrinsically Safe (optional), thereby making the product safe
for a wide variety of potentially hazardous area applications
The Safety Integrity Level, SIL 3 certification, puts the VPX
Series in the higher safety category as compared to its
competitors
FEATURES
VPX Series switches are certified for ATEX, IEC Ex, CE, cULus,
NEPSI, and KOSHA specifications for global applications
that requires protection from explosive gases, vapors &
combustible dust
Die-cast aluminum housing and various sealing (NEMA 4,
4X, 6, and 13), certifies the VPX Series is rated for rain, wind,
snow, ice and blowing dust environments
Wide operating temperature range from 40 °C to 80 °C (see
Table 1 for detailed specifications)
Versions of the VPX with proximity switches carry an
Intrinsically Safe (IS) rating
Well suited for up to 500,000 actuation cycles
Available in multiple indicator colors that is visible from all
directions
VALUE TO CUSTOMERS
cULus, ATEX, IEC EX, NEPSI, and KOSHA certified for
hazardous (explosive) environments
Designed with the end user in mind, these switches help
to create user-friendly interfaces with broad applications
possibilities to help meet the challenges of many different
environments
Weather sealed to NEMA and IP ratings
Reliable, dependable and accurate
Versions available in both snap-action switches and
intrinsically safe inductive proximity switches
POTENTIAL APPLICATIONS
Seaside grain and duel loading docks
Oil and gas wells
• Refineries
Fuel storage facilities
• Mining
Petrochemical and chemical plants
Waste water treatment facilities
Oil and gas production pipeline networks
Paint batching/blending plants
Pharmaceuticals and drug processing plants
Food and beverage industries
Pesticides manufacturing plants
Textile dyeing and finishing plants
Lead acid battery manufacturing facilities
PORTFOLIO
The VPX Series joins the CX Series of valve position indicator
switches for hazardous areas applications. The standard
offerings of the VPX Series is certified for flammable gases,
vapors and combustible dust. The VPX Series also offers the
Intrinsically Safe versions (optional). To view the entire product
portfolio, click here.
Sensing and Internet of Things
32321149
Issue E
2 sensing.honeywell.com
Valve Position Indicator, VPX Series
Table 1. Specifications
Characteristic Parameter
Series name VPX Series
Product type Valve Position Indicator
Housing material Aluminum with protective paint finish
Housing size 152,3 mm H x 140 mm W x 140 mm D [6.0 in H x 5.5 in W x 5.5 in D] ref.
Operating temperature
Versions with four electromechanical switches: 40 °C to 50 °C [40 °F to 122 °F]
Versions with two electromechanical switches: 40 °C to 60 °C [40 °F to 140 °F]
Versions with proximity switches: 40 °C to 80 °C [40 °F to 176 °F]
Sealing NEMA 4, 4X, 6, and 13 per UL 50E;
IP66 per IEC 600790; IP67 per IEC 60529 (self-certified by Honeywell)
Agency approvals
cULus, ATEX, IEC EX, CE, NEPSI, KOSHA
Explosion proof hazardous
area designations
North America: Division 1, Class I, Groups B, C, and D (Gas Rating)
Division 1, Class II, Groups E, F, and G (Dust Rating)
ATEX/IEC Ex:
II 2 G, II 2 D (ATEX Rating)
Ex db IIC T6 Gb (Gas Rating)
Ex tb IIIC T85°C Db (Dust Rating)
Ta 40 °C to +50 °C (Switch Code 4A or 4B)
Ta 40 °C to +60 °C (Switch Code 2A or 2B)
Intrinsically safe hazardous
area designations
Versions of the VPX with proximity switches carry an intrinsically safe rating:
North America: Not Available
ATEX/IEC Ex:
II 1 G, II 1 D (ATEX Rating)
Ex ia IIC T4 Ga (Gas Rating)
Ex ia IIIC T135°C Da (Dust Rating)
Ta 40 °C to 80 °C
Visual indicator Available in multiple colors and angles. Visible from all directions.
Electrical ratings
Versions with snap-action switches:
UL Rating: 15 A 150 Vac CE Rating: 16 A 250 Vac
10 A 250 Vac 0.5 A 250 Vdc
0.5 A 250 Vdc
Versions with Intrinsically Safe Proximity Switches:
Switch element function: NAMUR, NC
Nominal voltage: 8.2 V
Current consumption (On) ≤ 1 mA
Current consumption (Off) ≥ 3 mA
Mechanical endurance 500,000 cycles min.
Safety Integration Level (SIL)
SIL 3 per IEC 615082. The Mean Cycle to Failure (MCTF) requirements are:
Mechanical endurance MCTF: 500,000 cycles
Electrical endurance MCTF proximity switches: 50,000 cycles
Electrical endurance MCTF electromechanical switches loaded at 16 A 250 Vac: 25,000 cycles
Electrical endurance MCTF electromechanical switches loaded at 0.5 A 250 Vdc: 10,000 cycles
Shock IEC 60068227; half sine, 50 g, 11 mS, 3 axis
Vibration IEC 6006826; 10 Hz to 59 Hz with 1,5 mm peak-to-peak, 60 Hz to 500 Hz @ 5 g, 7.5 min sweeps,
20 sweeps per axis
Product weight 2,4 kg [5.2 lb] (approx.)
Sensing and Internet of Things 3
Valve Position Indicator, VPX Series
VPX
Series
1
Aluminum
Enclosure
Material
1
2A
4A
2X snap action
SPDT
4X snap action
SPDT
Switch
Options
2A
VP
X Series
Valve
Position
Indicator
YB Yellow (open)
Black (closed)
GY
RG Red (open)
Green (closed)
Green (open)
Yellow (closed)
YR
GR
Indicator
Color
China (standard)
IEC Ex, ATEX, CE, NEPSI
Origin and
Certifications
C
Yellow (open)
Red (closed)
2
1Namur
1/4 in flats
1
Shaft
End
Conduit
Entry
2A
2B 2X snap action
SPDT, gold
contacts
4B 4X snap action
SPDT, gold
contacts
GR Green (open)
Red (closed)
BY Black (open)
Yellow (closed)
RY Red (open)
Yellow (closed)
YG Yellow (open)
Green (closed)
2C 2X I.S. inductive
proximity
switch (Namur)
2A
2B
(2) 1/2-14 NPT
(A & D)
(2) 3/4-14 NPT
(A & D)
2C
2D
(2) M20 x 1.5
(A & D)
(2) M25 x 1.5
(A & D)
4C (4) M20 x 1.5
(4) M25 x 1.5
3B (3) 3/4-14 NPT
(A, B, & D)
4F (2) 1/2-14 NPT
(B & D) & (2)
3/4-14 NPT (A & D)
4D
A
China (premium)
IEC Ex, ATEX, cULus, CE, SIL3,
NEPSI, KOSHA
C
USA (premium)
IEC Ex, ATEX, cULus, CE, SIL3,
NEPSI, KOSHA
E
A
45°
Indicator
Angle
A
B
90°
3Ø7.25
knurl for
ex. lever
B
A360°
continuous
±90°
A
Shaft
Rotation
– _ _
Specials
Up to two
letters or number
s
to indicate a
special
feature.
1
Leave blank
for no plugs
1 plug
1
Number of
Conduit Plugs
3
22 plugs
3 plugs
Indicate how many
plugs should be
included. Any
unused conduit entries
must be sealed with a
blanking element
certified to the
hazardous location
environment
(or better). Plugs can
also be purchased
separately.
(see page 7).
Figure 1. Product Nomenclature
Table 2. Operating Characteristics
Characteristic Parameter
Operating torque 1,0 Nm [8.9 in-lb] max.
Operating point Adjustable to any angle in 4° increments
Factory set points for 4-switch
option
Switches 1 & 2: 25° ±25° when the shaft is rotated clockwise
Switches 3 & 4 (45° indicator): 45° ±25° when the shaft is rotated counterclockwise
Switches 3 & 4 (90° indicator): 90° ±25° when the shaft is rotated counterclockwise
Factory set points for 2-switch
option
Switch 1: 25° ±25° when the shaft is rotated clockwise
Switch 2 (45° indicator): 45° ±25° when the shaft is rotated counterclockwise
Switch 2 (90° indicator): 90° ±25° when the shaft is rotated counterclockwise
4 sensing.honeywell.com
Valve Position Indicator, VPX Series
Table 4. Order Guide
Catalog
Listing
Assembly
Location
Temperature
Rating
Temperature
Class
Hazardous
Location
Approvals
Switch
Options
Indicator
Angle
Indicator
Color Shaft
Shaft
Rotation
Conduit
China
USA
40 °C to 50 °C
40 °C to 60 °C
40 °C to 80 °C
T6
T4
IEC Ex
ATEX
cULus
KOSHA
NEPSI
2X snap action
4X snap action
2X I.S. Prox
Gold-plated contacts
45°
90°
Green/Red
Black/Yellow
Red/Yellow
Green/Yellow
NAMUR
1/4 in flats
Knurl
360°
±90°
(2) 1/214 NPT (A&D)
(2) 3/414 NPT (A&D)
(2) M20 x 1.5 (A&D)
(2) M25 x 1.5 (A&D)
(3) 3/414 NPT (A,B&D)
(4) M20 x 1.5
(4) M25 x 1.5
(2) 1/214 & (2) 3/414
VPX1C2ABGR1A2A ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1C2ABGR1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1C4ABYR1A3B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1C2CBGR1A2A ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1C2CBGR1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1C2ABYR1A2A ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1C2ABYR1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1C4ABGR1A3B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1C2CBYR1A2A ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1C2CBYR1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1C2ABGR1A4F ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1C2ABYR1A4F ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1C2CBGR1A4F ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1C2ABYB1A2A ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1C4ABGR1A2A ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E2ABYB1A2A ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E4ABYB1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E2ABBY1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E2ABYB1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E2ABGR1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E2ABRG1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E2ABBY2A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E2ABYB2A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E2ABGR2A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E2ABRG2A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
Sensing and Internet of Things 5
Valve Position Indicator, VPX Series
Catalog
Listing
Assembly
Location
Temperature
Rating
Temperature
Class
Hazardous
Location
Approvals
Switch
Options
Indicator
Angle
Indicator
Color Shaft
Shaft
Rotation
Conduit
China
USA
40 °C to 50 °C
40 °C to 60 °C
40 °C to 80 °C
T6
T4
IEC Ex
ATEX
cULus
KOSHA
NEPSI
2X snap action
4X snap action
2X I.S. Prox
Gold-plated contacts
45°
90°
Green/Red
Black/Yellow
Red/Yellow
Green/Yellow
NAMUR
1/4 in flats
Knurl
360°
±90°
(2) 1/214 NPT (A&D)
(2) 3/414 NPT (A&D)
(2) M20 x 1.5 (A&D)
(2) M25 x 1.5 (A&D)
(3) 3/414 NPT (A,B&D)
(4) M20 x 1.5
(4) M25 x 1.5
(2) 1/214 & (2) 3/414
VPX1E2ABBY3A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E2ABYB3A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E2ABGR3A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E2ABRG3A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E4ABBY1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E4ABGR1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E4ABRG1A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E4ABBY2A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E4ABYB2A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E4ABGR2A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E4ABRG2A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E4ABBY3A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E4ABYB3A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E4ABGR3A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E4ABRG3A2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E2BBYB3B2B ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü
VPX1E2CBYB1A2A ü ü ü ü ü ü ü ü ü ü ü ü ü ü
6 sensing.honeywell.com
Valve Position Indicator, VPX Series
Figure 2. Mounting Dimensions
CLOSED
75 [3.0] min.
to remove cover
95,8
[3.77]
Ø 105,8
[Ø 4.16]
52,0
[2.05]
4,5
[0.18] 2 X 32,5
[1.28]
65,0 [2.56]
29,0
[1.14]
140,0
[5.51]
Conduit Position “C”
Conduit
Position “D”
Conduit
Position “B”
Conduit
Position “A”
35,36
[1.392]
140,0
[5.51]
57,15
[2.25]
57,15
[2.25]
35,36
[1.392]
4 X M6 x 1 8
4 X M8 x 1.25
8
Sensing and Internet of Things 7
Valve Position Indicator, VPX Series
ACCESSORIES
A mounting bracket kit is available as an accessory, Honeywell part number VPZB1.
Figure 3. Accessory Bracket
80,0
[3.15]
30,0
[1.18]
30,0
[1.18]
130,0
[5.12]
47 ±10
[1.8 ±0.3
]47 ±10
[1.8 ±0.3]
Table 5. Conduit Plug Accessories
Size Honeywell
Part
Number
Tightening Specification
1/214 NPT VPZPA Hand tight and then 1 to 2 full turns using a wrench
3/414 NPT VPZPB Hand tight and then 1 to 2 full turns using a wrench
M20 x 1.5 VPZPC Hand tight and then 1/4 to 1 full turn using a wrench
M25 x 1.5 VPZPD Hand tight and then 1/4 to 1 full turn using a wrench
8 sensing.honeywell.com
Valve Position Indicator, VPX Series
Table 6. Lever Actuator Accessories
Lever Listing Description
LSZ51 Fixed, rollerless (1.5 R)
LSZ51A Fixed, 0.75 in x 0.25 in nylon roller, open (1.5 R)
LSZ51C Fixed, 0.75 in x 0.25 in nylon roller, closed (1.5 R)
LSZ52C Adjustable, 0.75 in x 0.25 in nylon roller, closed
LSZ52J Adjustable, 1.0 in x 0.5 in nylon roller, closed
LSZ52K Adjustable, 1.25 in x 0.25 in nylon roller, closed
LSZ53E Yoke, 0.75 in x 0.25 in nylon rollers, closed & open
LSZ53S Yoke, 0.75 in x 0.25 in nylon rollers, same side closed
LSZ54 Hub only
LSZ54M Hub, aluminum rod actuator
LSZ55 Offset lever, rollerless
LSZ55A Offset, 0.75 in x 0.25 in nylon roller, open
LSZ55C Offset, 0.75 in x 0.25 in nylon roller, closed
LSZ59A Fixed, 0.75 in x 0.25 in nylon roller, open (1.33 R)
LSZ59C Fixed, 0.75 in x 0.25 in nylon roller, closed (1.33 R)
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship during the appli-
cable warranty period. Honeywell’s standard product warranty
applies unless agreed to otherwise by Honeywell in writing;
please refer to your order acknowledgment or consult your
local sales office for specific warranty details. If warranted
goods are returned to Honeywell during the period of coverage,
Honeywell will repair or replace, at its option, without charge
those items that Honeywell, in its sole discretion, finds defec-
tive. The foregoing is buyer’s sole remedy and is in lieu of all
other warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While Honeywell may provide application assistance personally,
through our literature and the Honeywell web site, it is buyer’s
sole responsibility to determine the suitability of the product in
the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this writing.
However, Honeywell assumes no responsibility for its use.
32321149EEN IL50 GLO
November 2018
© 2018 Honeywell International Inc. All rights reserved.
m WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
m WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Find out more
Honeywell serves its customers
through a worldwide network
of sales offices, representatives
and distributors. For applica-
tion assistance, current specifi-
cations, pricing or name of the
nearest Authorized Distributor,
contact your local sales office.
To learn more about Honey-
well’s sensing and switching
products,
call +1-815-235-6847 or
1-800-537-6945,
visit sensing.honeywell.com,
or e-mail inquiries to
info.sc@honeywell.com
ADDITIONAL MATERIALS
The following associated literature is available at
sensing.honeywell.com:
Product range guide
Installation instructions
Application note
Honeywell Sensing and Internet of Things
9680 Old Bailes Road
Fort Mill, SC 29707
honeywell.com