D10 Expert
™
Dual Discrete Outputs
12 P/N 64154 rev. F
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Self-Diagnostic Error Modes
In the unlikely event that the setup parameters are lost or become corrupt, the display will
continuouslyscroll:“USErPSFError.”Reteachthesensortorecover.Iftheproblempersists,
contact your Banner representative for further information.
Gate Input
The pink wire is configured as a gate input. When this wire is pulled low (i.e., to the sensor
ground; 0-0.5V dc), it inhibits the outputs from switching, while all other sensor functions
continue to be enabled. This feature is useful for controlling when the outputs are allowed to
change states. Gate input function response time is 1 millisecond.
Required Fiber-Optic Cable Banner P-Series plastic fibers
Sensing Beam Visible red, 680 nm, or
Visible green, 525 nm, depending on model
Supply Voltage and Current 12 to 24V dc (10% maximum ripple) at less than 65 mA, exclusive of load
Supply Protection Circuitry Protected against reverse polarity and transient voltage
Output Configuration 2 NPN or 2 PNP, depending on model
Output Rating 150 mA maximum load
OFF-state leakage current: < 10 µA at 24V dc
ON-state saturation voltage: NPN < 1.5V at 150 mA load
PNP < 2.5V at 150 mA load
Output Protection Circuitry Protected against false pulse on power-up and continuous short-circuit
Output Response Time Programmable, 50 microseconds, 200 microseconds, 1 millisecond, 2.5 milliseconds
NOTE: < 1 second delay on power-up; outputs do not conduct during this time.
Adjustments Push-button or remote programming of response time, OFF-delay, light/dark operate, and display
Indicators Four-digitdigitaldisplayplusLEDindicatorsforactivechannel,push-buttonlockout,OFF-delayandlight/dark
operate selection; 2 yellow output indicators
Construction BlackABS/polycarbonatealloy(UL94V-0rated)housing,clearpolycarbonatecover
Environmental Rating NEMA 1, IEC IP50
Connections PVC-jacketed 2 m or 9 m (6.5' or 30') 6-wire integral cable or integral 6-pin Pico-style quick-disconnect
Operating Conditions Temperature: -20° to +55°C (-4° to +131°F)
Storage Temperature: -20° to +80°C (-4° to +175°F)
Max. Rel. Humidity: 90% @ 50°C (non-condensing)
Number of Devices,
Stacked
Ambient Temperature
Rating
Load
Specification
355°C 150 mA
750°C 50 mA
10 45°C 50 mA
Installation 35 mm DIN rail or included mounting bracket
Certifications