Oscilloscope Probes and Probe Accessories PROBE SELECTION GUIDE Learn More: teledynelecroy.com/probes Teledyne LeCroy has a wide variety of world class probes and amplifiers to compliment its product line. From the ZS high impedance active probes to the WaveLink differential probing system which offers bandwidths up to 25 GHz, Teledyne LeCroy probes and probe accessories provide optimum mechanical connections for signal measurement. HDO4000A High Definition Oscilloscopes HDO6000A High Definition Oscilloscopes WaveRunner 8000 Oscilloscopes HDO8000A High Definition Oscilloscopes / MDA800A Motor Drive Analyzers HDO9000 High Definition Oscilloscopes WavePro HD Oscilloscopes WaveMaster/SDA/DDA/8 Zi-B Oscilloscopes LabMaster 10 Zi-A Oscilloscopes WaveSurfer 510 Oscilloscopes WaveSurfer 3000z Oscilloscopes WaveJet Oscilloscopes Front Cover: ZS Series High Impedence Active Probes Active Voltage Rail Probes - p. 4 - 7 RP4030 Active Voltage Probes - p. 8 - 11 ZS1000 ZS1500 ZS2500 ZS4000 Current Probes - p. 12 - 15 CP030 CP030A CP031 CP031A CP150 CP500 CA10 Differential Probes - p. 16 - 25 ZD200 ZD500 ZD1000 ZD1500 AP033 D410-A-PB2 D420-A-PB2 D400A-AT-PB2 D610-A-PB2 D610-A-PL D620-A-PB2 D620-A-PL D600A-AT-PB2 D600A-AT-PL D830-PB2 D830-PL D1330-PL D1605-A-PLA D2005-A-PLA D2505-A-2.92MM High Voltage Differential Probes - p. 26 - 31 HVD3102A HVD3206A HVD3206A-6M HVD3605A HVD3106A HVD3106A-6M AP031 2 WaveSurfer 510 Oscilloscopes HDO4000A High Definition Oscilloscopes HDO6000A High Definition Oscilloscopes WaveRunner 8000 Oscilloscopes HDO8000A High Definition Oscilloscopes / MDA800A Motor Drive Analyzers HDO9000 High Definition Oscilloscopes WavePro HD Oscilloscopes WaveMaster/SDA/DDA/8 Zi-B Oscilloscopes LabMaster 10 Zi-A Oscilloscopes WaveSurfer 3000z Oscilloscopes WaveJet Oscilloscopes Learn More: teledynelecroy.com/probes Differential Amplifiers - p. 32 - 35 DXC200 DA101 DA1855A DA1855A-PR2 DA1855A-PR2-RM DA1855A-RM DXC-5100 DXC100A High Voltage Probes - p. 36 - 39 HVP120 PPE4KV PPE5KV PPE6KV High Voltage Fiber Optically-isolated Probes - p. 40 - 43 HVFO103 Optical-To-Electrical Converters - p. 44 - 47 OE6250G-M OE695G OE425 OE455 OE525 OE555 Passive Probes - p. 48 - 51 PP006C PP016 PP019 PP020 PP021 PP022 PP023 PP024 PP025 PP026 Probe Adapters - p. 52 - 53 CA10 TPA10 Transmission Line Probes - p. 54 - 55 PP066 3 ACTIVE VOLTAGE RAIL PROBE 4 ACTIVE VOLTAGE RAIL PROBE The RP4030 is designed specifically to probe a 50 DC power/voltage rail. The probe has large built-in offset, low attenuation (noise), and high DC input impedance. Built-in offset and low attenuation permit the power/voltage rail to be offset in the oscilloscope by its mean DC voltage with high oscilloscope gain (sensitivity) to achieve a noise-free view of small signal variations. The Teledyne LeCroy Active Voltage Rail Probe Model Numbers: RP4030 high DC input impedance eliminates loading of the DC rail. Opposite page: Active Voltage Rail Probes RP4030 working with an HDO8000A High Definition Oscilloscope 5 ACTIVE VOLTAGE RAIL PROBE Teledyne LeCroy Active Voltage Rail Probe Model Number: RP4030 Key Features 4 GHz Bandwidth 30V Offset Capability 800mV Dynamic Range 50 k DC Input Impedance 1.2x Attenuation (Low Additive Noise, ~5%) MCX terminated cable with wide variety of connections: * Solder-in (4 GHz) * Coaxial Cable to U.FL receptacle (3 GHz) * MCX PCB Mount (4 GHz) * Browser (350 MHz) ProBus Interface 6 Large Offset Range Permits the DC signal to be displayed in the vertical center of the oscilloscope grid with a high-sensitivity gain setting. Low Attenuation and Noise The probe attenuation is a nominal 1.2x coupled to the oscilloscope at DC 50 . This keeps additive noise to a minimum, and makes it exceptionally useful with High Definition oscilloscopes for lowest noise at highest sensitivity gain settings. High DC Input Impedance 50 k input impedance at DC effectively eliminates probe loading on the DC power/voltage rail and provides for more accurate measurements and signal fidelity. ACTIVE VOLTAGE RAIL PROBE 4 GHz of Bandwidth Provides maximum bandwidth for probing near the CPU, Wide Assortment of Tips and Leads and the perfect match with the 4 GHz, 10 bit HDO9404 The RP4030 is supplied standard with solder-in and coaxial when making power integrity measurements. cables with MCX and U.FL PCB receptacle mounts. A browser tip is optionally available. Additional receptacles or leads may be purchased as accessories and left connected in circuit for easy connection of different signals during different test or validation stages. Specifications Electrical Characteristics Bandwidth Rise Time (10-90%) Input Capacitance DC Input Resistance Offset Range Attenuation Input Dynamic Range Non-destruct Voltage Noise Oscilloscope Termination Ordering Information 4 GHz (guaranteed, MCX receptacle) 4 GHz (typical, solder-in lead) 3 GHz (typical, U.FL cable + receptacle) 350 MHz (typical, browser) 110 ps (typical, MCX receptacle or solder-in lead) 0.1 uF (in series with 50) 50 k 30V 1.2x 800 mV 50V ~5% additive to oscilloscope noise DC 50 Product Description Product Code Power/Voltage Rail Probe 4 GHz, 1.2x, 30V offset, 800mV dynamic range RP4030 Includes Qty. 1 ProBus compatible probe offset amplifier with 50 k DC input impedance and SMA input connection for provided 0.9m SMA to MCX extension cable. Also supplied are Qty. 3 MCX solder-in leads, Qty. 3 MCX PCB Mounts, Qty. 3 MCX to U.FL coaxial cables, Qty. 5 U.FL PCB Mounts, Qty. 1 MCX to SMA adapter, and soft carrying case. Browser tip sold separately. 350 MHz Browser Tip Accessory RP4000-BROWSER Includes 0 (1x), 450 (10x) and 950 (20x) tips. Environmental Operating Temperature Range 0 to 50 C Non-operating Temperature Range -40 to +70 C Humidity 5% to 80% RH (non-condensing) up to 30 C, decreasing linearly to to 45% RH at 50 C Operating Altitude 3000 meters maximum Physical RP4030 RP4000-BROWSER Other Oscilloscope Interface Software Requirements Weight Probe: 38.1 mm W x 15.9mm H x 73mm L (1-1/2" x 5/8" x 2-7/8") SMA to MCX Cable: 914mm L (36") MCX to Solder-in Lead: 191mm (71/2") usable length MCX to U.FL Plug Coaxial Cable: 102mm (4") usable length 11.9mm W x 9.5mm H x 38mm L (15/32" x 3/8" x 1-1/2") SMA to SMA Cable: 1m (39-3/8") usable length Teledyne LeCroy ProBus Teledyne LeCroy MAUI 8.2.1.1 or higher 119 g (0.26 lb) Accessories and Consumables Qty. 3 MCX 4 GHz solder-in leads Qty. 10 MCX PCB mount receptacle Qty. 3 MCX to U.FL 3 GHz ultra-mini coax cable Qty. 10 U.FL PCB mount receptacles RP4000-MCX-LEAD-SI RP4000-MCX-PCBMOUNT RP4000-MCX-CABLE-UFL RP4000-UFL-PCBMOUNT 7 ACTIVE VOLTAGE PROBES 88 ACTIVE VOLTAGE PROBES Engineers must commonly probe high-frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit and distort signals at higher frequencies. Active voltage probes feature both high input R and low input C to reduce circuit loading across the entire probe/oscilloscope bandwidth. With low circuit loading and a form factor that allows probing in confined areas, the active voltage probe becomes Teledyne LeCroy Active Voltage Probe Model Numbers: ZS1000 ZS1500 ZS2500 ZS4000 the everyday probe for all different types of signals and connection points. Opposite page: ZS Series High Impedance Active Probe 9 ZS SERIES ACTIVE PROBES The ZS Series probes are high impedance, low capacitance active probes that maintain high signal fidelity through 4 GHz. A small form factor and a wide variety of accessories ensures the ZS probe meets every difficult probing challenge. Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies but inappropriately load the circuit and distort signals at higher frequencies. The ZS Series features both high input R (1 M) and low input C (0.6 pF and 0.9 pF) to reduce circuit loading across the entire probe/oscilloscope Teledyne LeCroy Active Voltage Probe Model Numbers: bandwidth. The ZS1000 is ideal for 200-600 MHz oscilloscopes. The ZS1500 is ideal for 1 GHz oscilloscopes, the ZS2500 is ideal for 2 GHz oscilloscopes, and the ZS4000 is ideal for 2.5 GHz and 4 GHz oscilloscopes. ZS1000 ZS1500 ZS2500 ZS4000 ZS4000 PK-ZS-010 Channel ID Colored Clips PK-ZS-019 Freehand Probe Holder PK-ZS-006 Right Angle Socket PACC-PT005 Bent Tip PACC-PT003 IC Tip PK-ZS-001 Probe Tip - Standard PK-ZS-017 Pogo Tip PK-ZS-014 Y-Lead Adapter PK-ZS-023 Straight Pin Lead - 13cm PK-ZS-022 Straight Pin Lead - 7cm PACC-LD003 Right Angle Pin Lead - 5cm PACC-LD004 Right Angle Pin Lead - 10cm PK-ZS-018 2.54 mm Square Pin Adapter PK-ZS-021 Ground Blade Narrow PK-ZS-016 Offset Ground (Z Lead) PK-ZS-020 Pogo Ground Lead PK-ZS-015 Ground Blade - Wide PK-ZS-009 Copper Tape PK-ZS-024 2.54 mm PCB Adapter PK-ZS-007R Microclip Sprung Hook, Red 10 PK-ZF-025 QFPIC Clip Yellow Short PK-ZF-025 QFPIC Clip Green Short PK-ZS-007B Microclip Sprung Hook, Black ZS SERIES ACTIVE PROBES ZS1000 ZS1500 ZS2500 PK-ZS-010 Channel ID Colored Clips PACC-MS005 Freehand Probe Holderk PK-ZS-012 2.54 mm Square Pin Adapter PK-ZS-006 Right Angle Socket PACC-PT005 Bent Tip PACC-PT003 IC Tip PK-ZS-001 Probe Tip - Standard Qty: 3 PK-ZS-013 Pogo Tip PK-ZS-005 Y-Lead Adapter PK-ZS-004 Single Lead Long PK-ZS-003 Single Lead Short PACC-LD003 Right Angle Pin Lead - 5cm PACC-LD004 Right Angle Lead - Long PK-ZS-002 Offset Ground PACC-CD008 Pogo Ground Lead PK-ZS-008 Ground Blade - Narrow PK-ZS-011 Ground Blade - Wide PK-ZS-007R Microclip Sprung Hook, Red Ordering Information Standard Accessory/Quantity 2.54 mm PCB Adaptor 2.54mm Square Pin Adapter 2.54mm Square Pin Adaptor IC Tip Bent Tip Channel ID Clips (Set of 4 colors) Copper Tape Pad Freehand Probe Holder Freehand Probe Holder Ground Blade - Narrow Ground Blade - Wide Ground Blade, Narrow Ground Blade, Wide Micro-Grabber Pair Offset Ground PK-ZS-007B Microclip Sprung Hook, Black Specifications Product Description 4 GHz, 0.6 pF, 1 M High Impedance Active Probe 2.5 GHz, 0.9 pF, 1 M High Impedance Active Probe 1.5 GHz, 0.9 pF, 1 M High Impedance Active Probe 1 GHz, 0.9 pF, 1 M High Impedance Active Probe Set of 4 ZS2500, 2.5 GHz, 0.9 pF, 1 M High Impedance Active Probes Set of 4 ZS1500, 1.5 GHz, 0.9 pF, 1 M High Impedance Active Probes Set of 4 ZS1000, 1 GHz, 0.9 pF, 1 M High Impedance Active Probes Accessory Description PK-ZS-009 Copper Tape Replacement Part Number PK-ZS-024 PK-ZS-012 PK-ZS-018 PACC-PT003 PACC-PT005 Product Code ZS4000 ZS2500 ZS1500 ZS1000 ZS2500-QUADPAK ZS1500-QUADPAK ZS1000 ZS1500 ZS2500 ZS4000 Electrical Characteristics Probe Bandwidth Input Capacitance DC Input Resistance Probe Offset Range Attenuation Input Dynamic Range Non-destruct Voltage 1 GHz N/A General Characteristics Cable Length 1.5 GHz 0.9 pF 2.5 GHz 1 M 12 V /10 8 V 20 V 4 GHz 0.6 pF 1.3 m ZS1000-QUADPAK ZS1000 ZS1500 ZS2500 ZS4000 1 5 1 1 1 1 1 PK-ZS-010 4 1 PK-ZS-009 PK-ZS-019 PACC-MS005 PK-ZS-008 PK-ZS-011 PK-ZS-021 PK-ZS-015 PK-ZS-007R and PK-ZS-007B PK-ZS-016 2 2 1 1 1 1 1 1 2 2 2 Accessory Description Offset Ground - Z Lead Pogo Ground Lead Pogo Ground Lead Pogo Tip Pogo Tip Probe Tip - Standard QFPIC Clips (set of 2) Right Angle Lead - Long Right Angle Lead - Short Right Angle Socket Straight Pin Lead - Long Straight Pin Lead - Long Straight Pin Lead - Short Straight Pin Lead - Short Y Lead Adapter Y Lead Adaptor Replacement Part Number PK-ZS-002 PK-ZS-020 PACC-CD008 PK-ZS-017 PK-ZS-013 PK-ZS-001 PK-ZS-025 PACC-LD004 PACC-LD003 PK-ZS-006 PK-ZS-023 PK-ZS-004 PK-ZS-022 PK-ZS-003 PK-ZS-005 PK-ZS-014 ZS1000 ZS1500 ZS2500 ZS4000 1 1 1 3 1 1 1 1 1 1 1 3 3 1 1 1 1 1 1 1 11 CURRENT PROBES 12 CURRENT PROBES Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements. Wide Range of Applications Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies. High Sensitivity The CP030A and CP031A provide a high sensitivity of 1 mA/div. This Teledyne LeCroy Current Probe and Adapter Model Numbers: CP030 CP030A CP031 CP031A CP150 CP500 DCS025 CA10 allows for more precise low current measurements on Teledyne LeCroy oscilloscopes. When used with HDO high definition oscilloscopes with HD4096 technology, users will obtain highly accurate, low current waveforms with unmatched 12-bit resolution for improved debug and analysis. Fully Integrated All Teledyne LeCroy current probes are powered through the Teledyne LeCroy ProBus connection and require no additional hardware. Along with providing power, the ProBus connection allows the current probe and oscilloscope to communicate, resulting in current waveforms automatically displayed on screen in Amps, and calculated power traces scaled correctly in Watts. This (R) full integration also allows for Degauss and Autozero functions to be done directly from the oscilloscope's user interface. Deskew Calibration Source The DCS015 deskew calibration source has both voltage and current timealigned signals, which enables the precise deskew of voltage and current probes. Most voltage probes along with the CP030, CP030A, CP031, and CP031A are compatible with the DSC025. Opposite page: CP031, 30A, 100 MHz Current Probe. 13 CURRENT PROBES Key Features * ProBus active probe interface withautomatic scaling in A/div * Autozero and degauss capabilities built into instrument's user interface * Wide range of input currents and bandwidth capabilities Teledyne LeCroy Current Probe and Adapter Model Numbers: CP030 CP030A CP031 CP031A CP150 CP500 DCS025 CA10 CP030 30 Arms continuous current 50 Apeak current 50 MHz bandwidth - - - CP031 30 Arms continuous current 50 Apeak current 100 MHz bandwidth - - - CP150 150 Arms continuous current 500 Apeak current 10 MHz bandwidth - - - CP030A A continuous current - 30 50 - 50 AMHzcurrent - 1 mA/divbandwidth sensitivity - rms peak CP031A 30 Arms continuous current 50 Apeak current 100 MHz bandwidth 1 mA/div sensitivity - - - - CP500 500 Arms continuous current 700 Apeak current 2 MHz bandwidth - - - DCS025 deskew of voltage and - Precise current probes. ompatible with the CP030, CP030A, - CCP031, CP031A, AP015, CP150, and CP500 14 CURRENT PROBES CA10 Current Sensor Adapter The CA10 enables a third-party current measurement device to operate like a Teledyne LeCroy probe. The CA10 is programmable and customizable to work with third-party current measurement devices that output voltage or current signals proportional to measured current. (See page 52 for more information and specifications). Specifications Electrical Characteristics* Max. Continuous Input Current Bandwidth CP030 (CP030-3M) 50 MHz (10 MHz) 7 ns ( 35 ns) Max. Peak Current General Characteristics Cable Length Weight Max. Conductor Size (Diameter) Interface Usage Environment Operating Temperature Max. Relative Humidity Max. Altitude Maximum Insulated Wire Voltage CP031 CP031A 30 Arms Rise Time (typical) Output Voltage Max Continuous Input Current at 1 V/A (100mA/div or less) Offset Range at 1V/A (100mA/div or less) Minimum Sensitivity Low-Frequency Accuracy AC Noise at 20 MHz BWL Coupling CP030A 0.1 V/A CP150 (CP150-6M) CP500 150 Arms 500 Arms 10 MHz 2 MHz (5 MHz) 35 ns 3.5 ns 175 ns ( 70 ns) 300 Apeak (non-continuous); 700 Apeak 50 Apeak (non-continuous) 500 Apeak 30 s (non-continuous) 0.1 V/A & 1 V/A 0.1 V/A 0.1 V/A & 1 V/A 0.01 V/A 100 MHz - 5A - 5A - - 5 A - 5 A - 10 mA/div 1 mA/div 10 mA/div 100 mA/div 2.5 mA 150 A 2.5 mA 1 mA/div 1% 150 A AC, DC, GND 1.5 m (3 m) 240 g (290 g) 1.5 m 260 g 240 g 260 g 5 mm 6.0 mA 8.0 mA 2m (6 m) 500 g (600 g) 6m 630 g 20 mm ProBus, 1 M only Indoor 0 C to 40 C 80% 2000 m 300 V CAT I 600 V CAT II, 300 V CAT III * Electrical Characteristics Guaranteed at 23 C 3 C CP03x, CP150, and CP500 probes (and long cable versions of these) are compatible with any Teledyne LeCroy oscilloscope with a ProBus interface running firmware version 4.3.1.1 or greater. CP03xA probes are compatible with most Teledyne LeCroy oscilloscopes with a ProBus interface running X-StreamTM firmware version 7.8.x.x or later. Ordering Information Product Description ProBus Current Sensor Adapter Set of 4 CA10, ProBus Current Sensor Adapters 30 A; 50 MHz Current Probe - AC/DC; 30 Arms; 50 A Peak Pulse, 1.5 meter cable 30A; 10 MHz Current Probe - AC/DC, 30 Arms; 50 A Peak Pulse, 3 meter cable (not EMC compliant) 30 A; 50 MHz High Sensitivity Current Probe - AC/DC; 30 Arms; 50 A Peak Pulse, 1.5 meter cable 30 A; 100 MHz Current Probe - AC/DC; 30 Arms; 50 A Peak Pulse, 1.5 meter cable 30 A; 100 MHz High Sensitivity Current Probe - AC/DC; 30 Arms; 50 A Peak Pulse, 1.5 meter cable 150 A; 10 MHz Current Probe - AC/DC; 150 Arms; 500 A Peak Pulse, 2 meter cable 150 A; 5 MHz Current Probe - AC/DC; 150 Arms; 500 A Peak Pulse, 6 meter cable (not EMC compliant) 500 A; 2 MHz Current Probe - AC/DC; 500 Arms; 700 A Peak Pulse, 6 meter cable Deskew Calibration Source for CP030, CP030A, CP031, CP031A, AP015, CP150, CP500 Product Code CA10 CA10-QUADPAK CP030 CP030-3M CP030A CP031 CP031A CP150 CP150-6M CP500 DCS025 15 DIFFERENTIAL PROBES 16 DIFFERENTIAL PROBES Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point. Teledyne LeCroy Differential Probe Model Numbers: 1.5 GHz ZD200 ZD500 ZD1000 ZD1500 AP033 4 GHz - 6 GHz D410-A-PB2 D420-A-PB2 D400A-AT-PB2 D610-A-PB2 D610-A-PL D620-A-PB2 D620-A-PL D600A-AT-PB2 D600A-AT-PL 8 GHz - 13 GHz D830-PB2 D830-PL D1330-PL 13 GHz - 25 GHz D1605-A-PLA D2005-A-PLA D2505-A-2.92MM Opposite page: WaveLink(R) High Bandwidth Differential Probing System (13 GHz - 25 GHz) 17 1.5 GHz DIFFERENTIAL PROBES The ZD Series probes provide wide dynamic range, excellent noise and loading performance and an extensive set of probe tips, leads, and ground accessories to handle a wide range of probing scenarios. The low 1 pF capacitance means this probe is ideal for all frequencies. The ZD Series differential probes provide full system bandwidth for all Teledyne LeCroy Oscilloscopes 1.5 GHz and lower. Fully Integrated Teledyne LeCroy 1.5 GHz Differential Probe Model Numbers: ZD200 ZD500 ZD1000 ZD1500 AP033 With the ProBus interface, the ZD500, 1000, and 1500 become an integral part of the oscilloscope. All probe gain and offset controls are transparent to the user, making it easier to probe the circuit without concern for which gain setting to choose. When used with a Teledyne LeCroy digital oscilloscope, no external power supply is required. Wide Dynamic Range The ZD500, 1000, 1500 probes provide transparent probe attenuation so signals are always optimized for the display. The differential range is 18 Vp-p with a differential offset of 8V and common mode range of 10 V, making these probes versatile for every probing application. Wide Applications The wide dynamic range of 16 Vp-p and offset range of 8V suit this probe to a wide range of applications and signal types. The ZD differential probes are ideally suited for Automotive, Serial Data, power, and general purpose use. Specifications ZD200 ZD500 ZD1000 ZD1500 Bandwidth (Warranted) Bandwidth (Typical) Risetime 10-90% (Typical) Risetime 20-80% (Typical) LF Attenuation Accuracy (Warranted) Zero Offset (Typical) (within 15 minutes after autozero) System Noise (Typical) Probe Noise Density (Typical) Input Differential Range (Nominal) Differential Offset Range (Nominal) Offset Gain Accuracy (Typical) Common Mode Range (Nominal) Maximum Non-destruct Voltage (Nominal) CMRR (Typical) 200 MHz 500 MHz 650 MHz 650 ps 500 ps 1000 MHz 1200 MHz 375 ps 280 ps 2% 5 mV 1500 MHz 1700 MHz 270 ps 200 ps Electrical Characteristics DC Input Resistance (Nominal) Differential Input Capacitance (Typical) 18 - 1.75 ns - 1% - 3 mVrms 20 V 1.3 mVrms - 60 V - 80 dB @ 60 Hz 50 dB@10 MHz 250 k (Common Mode) 1 M (Differential Mode) 3.5 pF 60 dB 50/60 Hz 30 dB 20 MHz 25 dB 500 MHz 38 nV/rt (Hz) 8 V (16 Vp-p) 18 V 2% 10 V 30 V 1.75 mVrms 60 dB 50/60 Hz 30 dB 20 MHz 25 dB @ 1000 MHz 50 k (Common Mode) 120 k (Differential Mode) < 1.0 pF 60 dB 50/60 Hz 30 dB 20 MHz 25 dB @ 1500 MHz 1.5 GHz DIFFERENTIAL PROBES Ordering Information Product Description 200 MHz, 3.5 pF, 1 M Active Differential Probe 500 MHz, 1.0 pF Active Differential Probe, 8 V 1 GHz, 1.0 pF Active Differential Probe, 8 V 1.5 GHz, 1.0 pF Active Differential Probe, 8 V PCF200 Probe Calibration Fixture PACC-MS001 Hands Free Probe Holder Product Code ZD200 ZD500 ZD1000 ZD1500 PACC-MS001 Hands Free Probe Holder ZD1500 / ZD1000 / ZD500 Probe PCF200 Probe Calibration Fixture ZD1500 / ZD1000 / ZD500 Probe PCF200 Probe Calibration Fixture PACC-PT001 Straight Tip Qty: 4 PACC-ZD004 Tip Saver Qty: 2 PACC-ZD005 Swivel Tip Adapter PACC-ZD003 Spring-loaded Ground (Long) Qty: 2 PACC-ZD001 Y Lead Adapter PACC-ZD006 Small IC Adapter Qty: 2 PACC-CD008 Spring-loaded Ground (Short) Qty: 2 PACC-LD003 Right Angle Connector (Short) Qty: 2 PACC-ZD002 Solder-In-Lead Qty: 2 PK006-4 Micro-Grabber Qty: 2 PACC-CL001 Mini-Grabber Qty: 2 PACC-LD004 Right Angle Connector (long) Qty: 2 PACC-ZD004 Tip Saver Qty: 2 AP033 PACC-PT001 Straight Tip Qty: 4 PACC-ZD005 Swivel Tip Adapter PACC-ZD003 Spring-loaded Ground (Long) Qty: 2 PACC-ZD006 Small IC Adapter Qty: 2 High bandwidth, excellent common-mode rejection ratio PK006-4 Micro-Grabber Qty: 2 PACC-CL001 Mini-Grabber Qty: 2 (CMRR) and low noise make these active differential PACC-ZD001 Y Lead Adapter PACC-ZD002 Solder-In-Lead Qty: 2 probes ideal for applications such as disk drive design and failure analysis, as well as wireless and data PACC-LD004 Right Angle Connector (long) Qty: 2 communication design. PACC-CD008 Spring-loaded Ground (Short) Qty: 2 Specifications Bandwidth Gain PK006-4 Micro-Grabber Qty: 2 PACC-LD003 Right Angle Connector (Short) Qty: 2 DC Accuracy Input Resistance PACC-LD004 Right Angle Connector (long) Qty: 2 Differential Mode Range Offset Range Common-Mode Range CMRR Ordering Information Product Description 500 MHz Differential Probe PACC-CL001 Mini-Grabber Qty: 2 500 MHz x10, x1, /10 (/100 with plug-on /10 attenuator) 1% in x1 without external attenuator 1 M each input to ground 2 M differential between inputs 400 mV (x1) 40 mV (x10) 4 V (/10) 40 V (/100) 400 mV (x1, x10) 4 V (10) 40 V (100) 42 V peak (10) +4.2 V peak (100) 70 Hz 10,000:1 (80 dB) 100 kHz 10,000:1 (80 dB) 1 MHz 1000:1 (60 dB) 10 MHz 100:1 (40 dB) 250 MHz 5:1 (14 dB) Product Code AP033 19 4 GHz - 6 GHz DIFFERENTIAL PROBES Teledyne LeCroy's WaveLink 4-6 GHz Differential Probes are a general purpose probing solution with high-input dynamic range and offset range capability. The range of capabilities is ideal for a variety of high-speed DDR signals where high dynamic range and large offset requirements are common. Key Features Teledyne LeCroy 4 GHz - 6 GHz Differential Probe Model Numbers: D410-A-PB2 D420-A-PB2 D400A-AT-PB2 D610-A-PB2 D610-A-PL D620-A-PB2 D620-A-PL D600A-AT-PB2 D600A-AT-PL 20 * 4 GHz or 6 GHz models * Up to 5 Vpk-pk dynamic range with low noise * 3 V offset range * Ideal for DDR2, LPDDR2, DDR3 * Innovative QuickLink architecture * Wide variety of tips and leads - Solder-In Lead - QuickLink Solder-In Lead - Positioner (Browser) Tip - Adjustable (Browser) Tip - Quick Connect Lead - Square Pin Lead - Hi-Temp Solder-In Lead * Low loading and high impedance for minimal signal disturbance * Deluxe soft carrying case 4 GHz - 6 GHz DIFFERENTIAL PROBES Bandwidth* (Probe only, guaranteed) (System bandwidth, typical) Rise Time* (10-90%) Rise Time* (20-80%) Noise (System) Input Input Dynamic Range (Nominal) Input Common Mode Voltage Range (Nominal) Input Offset Voltage Range Non-destructive Input Range (Nominal) Attenuation DC Input Resistance (Nominal) D610-A-PB2, D610-A-PL D620-A-PB2, D620-A-PL D410-A-PB2 D420-A-PB2 Dx10-SI, Dx10-QL-SI, Dx10-HiTemp, Dx10-QC and Dx10-PT Tips 4 GHz Dx20-SI, Dx20-QL-SI, Dx20-HiTemp, Dx20-QC and Dx20-PT Tips 4 GHz Dx10-SP Tip 3 GHz Dx20-SP Tip 3 GHz Dx10-SI, Dx10-QL-SI, Dx10-HiTemp, Dx10-QC and Dx10-PT Tips 112 ps (typical) Dx20-SI, Dx20-QL-SI, Dx20-HiTemp, Dx20-QC and Dx20-PT Tips 112 ps (typical) Dx10-QC Tip 122.5 ps (typical) Dx20-QC Tip 122.5 ps (typical) Dx10-SP Tip 150 ps (typical) Dx20-SP Tip 150 ps (typical) Dx10-SI, Dx10-QL-SI, Dx10-HiTemp, Dx10-QC and Dx10-PT Tips 84 ps (typical) Dx20-SI, Dx20-QL-SI, Dx20-HiTemp, Dx20-QC and Dx20-PT Tips 84 ps (typical) Dx10-QC Tip 92 ps (typical) Dx20-QC Tip 92 ps (typical) Dx10-SP Tip 113 ps (typical) Dx20-SP Tip 113 ps (typical) Dx10-SI, Dx10-QL-SI and Dx10-PT Tips 6 GHz Dx20-SI, Dx20-QL-SI and Dx20-PT Tips 6 GHz Dx10-HiTemp 5 GHz Dx20-HiTemp 5 GHz Dx10-QC Tip 4 GHz Dx20-QC Tip 4 GHz Dx10-SP Tip 3 GHz Dx10-SI, Dx10-QL-SI and Dx10-PT Tips 75 ps (typical) Dx20-SP Tip 3 GHz Dx20-SI, Dx20-QL-SI and Dx20-PT Tips 75 ps (typical) Dx10-HiTemp 90 ps (typical) Dx20-HiTemp 90 ps (typical) Dx10-QC Tip 122.5 ps (typical) Dx20-QC Tip 122.5 ps (typical) Dx10-SP Tip 150 ps (typical) Dx10-SI, Dx10-QL-SI and Dx10-PT Tips 56 ps (typical) Dx20-SP Tip 150 ps (typical) Dx20-SI, Dx20-QL-SI and Dx20-PT Tips 56 ps (typical) Dx10-HiTemp 67.5 ps (typical) Dx20-HiTemp 67.5 ps (typical) Dx10-QC Tip 92 ps (typical) Dx20-QC Tip 92 ps (typical) Dx10-SP Tip 113 ps (typical) <36 nV/Hz (2.8 mVrms) (typical) Referred to input, 6 GHz bandwidth Dx20-SP Tip 113 ps (typical) <61 nV/Hz (4.8 mVrms) (typical) Referred to input, 6 GHz bandwidth <36 nV/Hz (2.3 mVrms) (typical) Referred to input, 4 GHz bandwidth <67 nV/Hz (4.3 mVrms) (typical) Referred to input, 4 GHz bandwidth 2.5Vpk-pk, 1.25V 5Vpk-pk, 2.5V 2.5Vpk-pk, 1.25V 5Vpk-pk, 2.5V D600A-AT-PB2, D600A-AT-PL D400A-AT-PB2 6 GHz 4 GHz <75 ps (typical) <112 ps (typical) 56 ps (typical) 84 ps (typical) <74 nV/Hz (5.8 mVrms) (typical) Referred to input, 6 GHz bandwidth <74 nV/Hz (4.7 mVrms) (typical) Referred to input, 4 GHz bandwidth 4 V 1.7X / 1.0X (nominal) 4.8Vpk-pk, 2.4V 2.4 Vmax 3 V Differential (nominal) n/a 20 V 18 V 3.2X / 1.9X (nominal) 1.7X / 1.0X (nominal) 200 k Differential 50 k Common Mode 3.2X / 1.9X (nominal) 2.5X 4 k Differential 1 k Common Mode * All Bandwidth and Rise Time measurements are made with an oscilloscope bandwidth greater or equal to the probe bandwidth Through entire frequency range Product Description Complete Differential Probes 4 GHz ProBus2 Differential Probe with Dx10-SI Solder-In Tip (Qty. 1), Dx10-SP Square Pin (Qty. 1), and Dx10-QC Quick Connect (Qty. 1) 4 GHz ProLink Differential Probe with Dx10-SI Solder-In Tip (Qty. 1), Dx10-SP Square Pin (Qty. 1), and Dx10-QC Quick Connect (Qty. 1) 4 GHz ProBus2 Differential Probe with Dx20-SI Solder-In Tip (Qty. 1), Dx20-SP Square Pin (Qty. 1), and Dx20-QC Quick Connect (Qty. 1) 4 GHz ProLink Differential Probe with Dx20-SI Solder-In Tip (Qty. 1), Dx20-SP Square Pin (Qty. 1), and Dx20-QC Quick Connect (Qty. 1) 6 GHz ProBus2 Differential Probe with Dx10-SI Solder-In Tip (Qty. 1), Dx10-SP Square Pin (Qty. 1), and Dx10-QC Quick Connect (Qty. 1) 6 GHz ProLink Differential Probe with Dx10-SI Solder-In Tip (Qty. 1), Dx10-SP Square Pin (Qty. 1), and Dx10-QC Quick Connect (Qty. 1) 6 GHz ProBus2 Differential Probe with Dx20-SI Solder-In Tip (Qty. 1), Dx20-SP Square Pin (Qty. 1), and Dx20-QC Quick Connect (Qty. 1) 6 GHz ProLink Differential Probe with Dx20-SI Solder-In Tip (Qty. 1), Dx20-SP Square Pin (Qty. 1), and Dx20-QC Quick Connect (Qty. 1) 4 GHz ProBus2 Differential Probe with Adjustable Tip 6 GHz ProBus2 Differential Probe with Adjustable Tip 6 GHz ProLink Differential Probe with Adjustable Tip Positioner Tip (Browser) Kits WaveLink Dx10-PT Adjustable Positioner Tip Kit. For use with Dx10 amplifiers. WaveLink Dx20-PT Adjustable Positioner Tip Kit. For use with Dx20 amplifiers. QuickLink Solder-In Tip Set QuickLink Solder-In starter pack for use with Dx10 amplifier. Includes one QuickLink adapter and three QL-SI tips. QuickLink Solder-In starter pack for use with Dx20 amplifier. Includes one QuickLink adapter and three QL-SI tips. Product Code D410-A-PB2 D410-A-PL D420-A-PB2 D420-A-PL D610-A-PB2 D610-A-PL D620-A-PB2 D620-A-PL D400A-AT-PB2 D600A-AT-PB2 D600A-AT-PL Dx10-PT-KIT Dx20-PT-KIT Dx10-QL-3SI Dx20-QL-3SI Product Description Accessories Probe Deskew and Calibration Test Fixture Calibration Options NIST Calibration for D410-A. Includes test data. NIST Calibration for D420-A. Includes test data. NIST Calibration for D610-A. Includes test data. NIST Calibration for D620-A. Includes test data. NIST Calibration for D400A-AT. Includes test data. NIST Calibration for D600A-AT. Includes test data. Replacement Parts Single replacement QuickLink Solder-In Tip 9-pack of replacement QuickLink Solder-In Tip Replacement Dx10-SI 4 & 6 GHz Solder-In Lead with Qty. 5 Spare Resistors. Replacement Dx20-SI 4 & 6 GHz Solder-In Lead with Qty. 5 Spare Resistors. Replacement Dx10-QC 4 & 6 GHz Quick Connect Lead Replacement Dx20-QC 4 & 6 GHz Quick Connect Lead Replacement Dx10-SP 4 & 6 GHz Square Pin Lead Replacement Dx20-SP 4 & 6 GHz Square Pin Lead Replacement SI Resistor Kit for Dx10/Dx20 - Kit of 20 Replacement QC Resistor Kit for Dx10/Dx20 - 2 kits of 20 Qty. 4 Replacement Pogo Pin Tips and Qty. 2 Replacement Sockets for Dx10-PT and Dx20-PT Adjustable Positioner Tips. Replacement Probe Tip Holder Kit Replacement Platform/Cable Assembly Mounting Kit Quantity 1 Package of Black Adhesive Pads (10/pkg) and Quantity 1 Package of White Adhesive Pads (10/pkg) Quantity 1 Package of Adhesive Probe Connection Guides (200 individual guides/package) Product Code TF-DSQ D410-A-CCNIST D420-A-CCNIST D610-A-CCNIST D620-A-CCNIST D400A-AT-CCNIST D600A-AT-CCNIST QL-SI-1Pack QL-SI-9Pack Dx10-SI Dx20-SI Dx10-QC Dx20-QC Dx10-SP Dx20-SP PKxx0-SI PKxx0-QC Dxx0-PT-TIPS PK600ST-3 PK600ST-4 Dxx0-PT-TAPE Dxx0-PT-GUIDES 21 8 GHz - 13 GHz DIFFERENTIAL PROBES The WaveLink Differential Probe Series is a 8-13 GHz bandwidth active differential probe series with high input dynamic range, a large offset capability, and a wide variety of tips and leads available for different applications. Key Features Teledyne LeCroy 8 GHz - 13 GHz Differential Probe Model Numbers: D830-PB2 D830-PL D1330-PL * Choice of 8 or 13 GHz bandwidth models * 3.5 Vpk-pk dynamic range * 4 V offset range * Ideal for DDR3, DDR4, LPDDR3 * Innovative QuickLink architecture * Wide variety of tips and leads - Solder-In Lead - QuickLink Solder-In Lead - Positioner (Browser) Tip - SMA/SMP Lead - Square Pin Lead - Hi-Temp Solder-In Lead * Low loading and high impedance for minimal signal disturbance * Deluxe soft carrying case * SMA/SMP lead set accessory does not require purchase of a different amplifier 22 8 GHz - 13 GHz DIFFERENTIAL PROBES Bandwidth* (Probe only, guaranteed) (System bandwidth, typical) D830-PB2, D830-PL Dxx30-SI, Dxx30-QL-SI, Dxx30-SMA-SMP, Dxx30-HiTemp, and Dxx30-PT Tips 8 GHz Dxx30-SP Tip 3 GHz Rise Time* (10-90%) Dxx30-SI, Dxx30-QL-SI, Dxx30-SMA-SMP, Dxx30-HiTemp, and Dxx30-PT Tips 50 ps (typical) Dxx30-SP Tip 100 ps (typical) Noise (System) Input Impedance (Zmin, typical) Impedance (mid-band, typical) Dxx30-PT and Dxx30-HiTemp Tips 40 ps (typical) Dxx30-SP Tip 132 ps (typical) Dxx30-SI and Dxx30-SMA-SMP Tips 26 ps (typical) Dxx30-PT and Dxx30-HiTemp Tips 30 ps (typical) Dxx30-QL-SI Tip 37.5 ps (typical) Dxx30-SP Tip 100 ps (typical) <48 nV/Hz (5.5 mVrms) (typical) Referred to input, 13 GHz bandwidth. <52nV/Hz (5.9 mVrms) (typical) Referred to input, 13 GHz bandwidth. <48 nV/Hz (4.3 mVrms) (typical) Referred to input, 8 GHz bandwidth. <52 nV/Hz (4.6 mVrms) (typical) Referred to input, 8 GHz bandwidth. Input Dynamic Range Input Common Mode Voltage Range Input Offset Voltage Range Non-destructive Input Range Attenuation DC Input Resistance (nominal) Dxx30-SP Tip 3 GHz Dxx30-SI and Dxx30-SMA-SMP Tips 35 ps (typical) Dxx30-QL-SI Tip 50 ps (typical) Dxx30-SI, Dxx30-QL-SI, Dxx30-SMA-SMP, Dxx30-HiTemp, and Dxx30-PT Tips 37.5 ps (typical) Noise (Probe) Dxx30-PT and Dxx30-HiTemp Tips 10 GHz Dxx30-QL-SI Tip 8 GHz Dxx30-SP Tip 132 ps (typical) Rise Time* (20-80%) D1330-PL Dxx30-SI and Dxx30-SMA-SMP Tips 13 GHz 3.5Vpk-pk, 1.75V (nominal) 5 V (nominal) 4 V Differential (nominal) 15 V (nominal) 3.75x (nominal) 200 k Differential 50 k Common mode >250 Differential through entire frequency range using SI tip Dxx30-SI, Dxx30-QL-SI, and Dxx30-HiTemp Tips 470 at 4 GHz, 320 at 6 GHz, 260 at 8 GHz, 250 at 9 GHz, 260 at 10 GHz, 350 at 13 GHz Dxx30-PT Tip 155 at 4 GHz, 210 at 6 GHz, 140 at 8 GHz, 80 at 9 GHz, 40 at 10 GHz 58 dB DC / 100 Hz 38 dB to 10 MHz 30 dB to 3 GHz 20 dB to 8 GHz (typical) CMRR * All Bandwidth and Rise Time measurements are made with an oscilloscope bandwidth greater or equal to the probe bandwidth Product Description Complete Differential Probes Product Code 8 GHz ProBus2 Differential Probe with Dxx30-SI Solder-In Tip (Qty. 2) and Dxx30-SP Square Pin (Qty. 1) 8 GHz ProLink Differential Probe with Dxx30-SI Solder-In Tip (Qty. 2) and Dxx30-SP Square Pin (Qty. 1) 13 GHz ProLink Differential Probe with Dxx30-SI Solder-In Tip (Qty. 2) and Dxx30-SP Square Pin (Qty. 1) Positioner Tip (Browser) Kits WaveLink Dxx30-PT (up to 10 GHz rating) Adjustable Positioner Tip Kit. For use with Dxx30 amplifiers. QuickLink Solder-In starter pack for use with Dxx30 amplifier. Includes one QuickLink adapter and three QL-SI tips. WaveLink Temperature Extension Cables for Dxx30. Includes set of Matched 30" High Temperature Cables (Qty. 1) and solder-in lead set (Qty. 1). SMA/SMP Lead Set SMA/SMP lead set for use with Dxx30 amplifiers. Includes a set of SMA leads, SMP leads, pair of DC blocks and SMA finger wrenches. D830-PL D1330-PL Dxx30-PT-KIT QuickLink Solder-In Tip Set Hi-Temp Lead Set D830-PB2 Dxx30-QL-3SI Dxx30-HiTemp Dxx30-SMA-SMP-LEADS Product Description Accessories Probe Deskew and Calibration Test Fixture Calibration Options NIST Calibration for D830. Includes test data. NIST Calibration for D1330. Includes test data. Replacement Parts Single replacement QuickLink Solder-In Tip 9-pack of replacement QuickLink Solder-In Tip Replacement Dxx30-SP 8-13 GHz Square Pin Lead Replacement Dxx30-SI 8-13 GHz Solder-In Lead with Qty. 5 Spare Resistors. Replacement SI Resistor Kit for Dxx05-SI, Dxx30-QL-SI and Dxx30-SI Solder-In Tip - Kit of 5 Qty. 4 Replacement Pogo Pin Tips and Qty. 2 Replacement Sockets for Dx10-PT, Dx20-PT, and Dxx30-PT Adjustable Positioner Tips. Replacement Probe Tip Holder Kit Replacement Platform/Cable Assembly Mounting Kit Quantity 1 Package of Black Adhesive Pads (10/pkg) and Quantity 1 Package of White Adhesive Pads (10/pkg) Quantity 1 Package of Adhesive Probe Connection Guides (200 individual guides/package) Product Code TF-DSQ D830-CCNIST D1330-CCNIST QL-SI-1Pack QL-SI-9Pack Dxx30-SP Dxx30-SI Dxx05-SI-RESISTORS Dxx0-PT-TIPS PK600ST-3 PK600ST-4 Dxx0-PT-TAPE Dxx05-PT-GUIDES 23 13 GHz - 25 GHz DIFFERENTIAL PROBES Ultra-wideband Architecture for Superior Signal Fidelity Teledyne LeCroy's WaveLink(R) high bandwidth differential probes utilize advanced differential traveling wave (distributed) amplifier architecture to achieve superior high frequency true analog broadband performance. Traveling wave (distributed) amplifiers are commonly used in ultra high frequency broadband amplifiers. This multi-stage amplifier architecture maximizes gain per stage and minimizes probe attenuation, which provides very low probe noise and fast rise times. Key Features Teledyne LeCroy 13 GHz - 25 GHz Differential Probe Model Numbers: D1605-A-PLA D2005-A-PLA D2505-A-2.92MM * * * * * * * * * Up to 25 GHz bandwidth (probe + oscilloscope) System rise time as fast as 13 ps (20-80%) 25 GHz Solder-in solution 22 GHz ultra-compact browser tip Superior probe impedance minimizes AC loading on device under test (DUT) Carbon-composite browser tips optimize signal fidelity and minimize loading Probe noise as low as 14 nV/Hz (1.6 mVrms) Low probe attenuation Large operating voltage range 4 V common mode range 2.5 V offset range * 24 2.0 Vpk-pk dynamic range Long length Solder-In tip with field replaceable resistors 13 GHz - 25 GHz DIFFERENTIAL PROBES Bandwidth D1605-A-PLA Dxx05-SI and Dxx05-PT Tips 16 GHz (probe only, guaranteed) 16 GHz (system bandwidth, when used with 816Zi, typical) D2005-A-PLA Rise Time (10-90%) Dxx05-SI and Dxx05-PT Tips 28 ps (typical) System rise time, measured with 16 GHz oscilloscope Dxx05-SI and Dxx05-PT Tips 20 ps (typical) System rise time measured with 20 GHz oscilloscope Rise Time (20-80%) Dxx05-SI and Dxx05-PT Tips 21 ps (typical) System rise time measured with 16 GHz oscilloscope Dxx05-SI and Dxx05-PT Tips 15 ps (typical) System rise time measured with 20 GHz oscilloscope < 14 nV/Hz (1.8 mVrms) (typical) Referred to input, 16 GHz bandwidth < 23 nV/Hz (2.9 mVrms) (typical) Referred to input, 16 GHz bandwidth < 18 nV/Hz (2.5 mVrms) (typical) Referred to input, 20 GHz bandwidth < 28 nV/Hz (4.0 mVrms) (typical) Referred to input, 20 GHz bandwidth Noise (Probe) Noise (System) Input Input Dynamic Range Input Common Mode Voltage Range Input Offset Voltage Range Non-destructive Input Range Attenuation DC Input Resistance (nominal) Impedance (Zmin, typical) Impedance (mid-band, typical) 2.0 Vpk-pk, (1.0 V) (nominal) 4 V (nominal) 2.5 V Differential (nominal) 10 V (nominal) 3.5x (nominal) D2505-A-2.92MM Dxx05-SI and Dxx05-PT Tips 20 GHz (probe only, guaranteed) 20 GHz (system bandwidth, when used with 820Zi, typical) Dxx05-SI Lead 25 GHz (probe only, guaranteed) 25 GHz (system bandwidth, when used with 825Zi, typical) Dxx05-PT Tip 22 GHz (system bandwidth, when used with 825Zi, typical) 20 GHz (probe only, guaranteed) Dxx05-SI Lead 17.5 ps (typical) System rise time measured with 25 GHz oscilloscope Dxx05-PT Tip 19 ps (typical) System rise time measured with 25 GHz oscilloscope Dxx05-SI Lead 13 ps (typical) System rise time measured with 25 GHz oscilloscope Dxx05-PT Tip 14 ps (typical) System rise time measured with 25 GHz oscilloscope < 18 nV/Hz (2.8 mVrms) (typical) Referred to input, 25 GHz bandwidth < 28 nV/Hz (4.5 mVrms) (typical) Referred to input, 25 GHz bandwidth 4.5x (nominal) Dxx05-SI Lead > 300 Differential through entire frequency range 1.1 k Differential 100 k Common mode Dxx05-SI Lead > 230 Differential through entire frequency range Dxx05-SI Lead > 120 Differential through entire frequency range Dxx05-PT Tip >160 Differential through entire frequency range Dxx05-PT Tip >160 Differential through entire frequency range Dxx05-PT Tip >160 Differential through entire frequency range CMRR Environmental Dxx05-SI Lead: 300 at 6 GHz, 525 at 13 GHz, 600 at 16 GHz, 300 at 20 GHz, 120 at 25 GHz Dxx05-PT Tip: 160 at 6 GHz, 450 at 13 GHz, 240 at 16 GHz, 210 at 20 GHz Dxx05-SI Lead (typical): 40 dB DC to 50 MHz; 32 dB to 1 GHz; 20 dB to 16 GHz; 15 dB to 25 GHz Dxx05-PT Tip (typical): 36 dB DC to 50 MHz; 30 dB to 1 GHz; 16 dB to 16 GHz; 14 dB to 20 GHz Temperature Humidity ESD Tolerance Product Description Complete Differential Probes 16 GHz ProLink-A Differential Probe with Dxx05-SI Solder-In Tip (Qty. 2) 20 GHz ProLink-A Differential Probe with Dxx05-SI Solder-In Tip (Qty. 2) 25 GHz 2.92MM Differential Probe with Dxx05-SI Solder-In Tip (Qty. 2) Operating: 0 C to 40 C; Non-operating: -40 C to 70 C Operating: 5% to 80% RH (non-condensing): 50% RH above 30 C Non-operating: 5% to 95% RH (non-condensing) 75% RH above 30 C and 45% RH above 40 C 2 kV (typical) 100 pF, 300 HBM Product Code D1605-A-PL Probe Deskew and Calibration Test Fixture D2005-A-PL NIST Calibration for D1605. Includes Test Data NIST Calibration for D2005. Includes Test Data NIST Calibration for D2505. Includes Test Data D2505-A-2.92MM Positioner Tip (Browser) Kits WaveLink Dxx05-PT (Up to 22 GHz Rating) Adjustable Positioner Tip Kit. For use with Dxx05 Amplifiers Dxx05-PT-KIT Probe Adapters ProLink to 2.92 mm Adapter with Probe Power and Communication Pass Through Product Description Accessories LPA-2.92 Calibration Options Replacement Parts Replacement Dxx05-SI 16-25 GHz Solder-In Lead with Qty. 5 Spare Resistors Replacement SI Resistor Kit for Dxx05-SI, Dxx30-QL-SI and Dxx30-SI Solder-In Tip - Kit of 5 Replacement Dxx05-PT Positioner Tip Qty. 4 Replacement Carbon Composite Pogo-pin Tips Replacement Probe Tip Holder Kit Replacement Platform/Cable Assembly Mounting Kit Qty. 1 Package of Black Adhesive Pads (10/pkg.) and Qty. 1 Package of White Adhesive Pads (10/pkg.) Qty. 1 Package of Adhesive Probe Connection Guides (200 individual guides/package) Product Code TF-DSQ D1605-A-CCNIST D2005-A-CCNIST D2505-A-CCNIST Dxx05-SI Dxx05-SI-RESISTORS Dxx05-PT Dxx05-PT-TIPS PK600ST-3 PK600ST-4 Dxx0-PT-TAPE Dxx05-PT-GUIDES 25 HIGH VOLTAGE DIFFERENTIAL PROBES 26 HIGH VOLTAGE DIFFERENTIAL PROBES Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point. Teledyne LeCroy High Voltage Differential Probe Model Numbers: HVD3102A HVD3106A HVD3106A-6M HVD3206A HVD3206A-6M HVD3605A AP031 Opposite page: HVD3000A Series High Voltage Differential Probes working with an MDA800A Motor Drive Analyzer 27 HIGH VOLTAGE DIFFERENTIAL PROBES Teledyne LeCroy High Voltage Differential Probe Model Numbers: HVD3102A HVD3106A HVD3106A-6M HVD3206A HVD3206A-6M HVD3605A The HVD3000A series high voltage differential probes provide high CMRR over a broad frequency range to simplify the measurement challenges found in noisy, high common-mode power electronics environments. The probe's design is easy-to-use and enables safe, precise high voltage floating measurements. Key Features * * * * * * * * * 28 1 kV, 2 kV, 6 kV CAT safety rated models Widest differential voltage ranges available Exceptional common-mode rejection ratio (CMRR) across a broad frequency range 1% gain accuracy High offset capability at both high and low attenuation AC and DC coupling ProBus active probe interface with automatic scaling AutoZero with auto disconnect switch Wide oscilloscope compatibility HIGH VOLTAGE DIFFERENTIAL PROBES Bandwidth Differential Voltage Range Max Safe Input Voltage HVD3102A HVD3106A 25 MHz 1500 V (DC + peak AC) (1750V maximum typical measurable before saturation) 120 MHz Gain Accuracy Cable Length Included Tip Accessories HVD3106A-6M 80 MHz 1500 V (DC + peak AC) (2000V maximum typical measurable before saturation) HVD3206A HVD3206A-6M HVD3605A 120 MHz 80 MHz 100 MHz 7000 V (DC + peak AC) (7600 V maximum typical measurable before saturation) 8485 V (DC + peak AC) CAT I 6000 Vrms CAT I 1000 Vrms CAT III 1000 Vdc CAT III 2000 V (DC + peak AC) 1000 Vrms CAT III 2000 V (DC + peak AC) CAT I 1500 Vdc CAT III 1000 Vrms CAT III 1% 2.25 meters Yes 6.8 meters Yes Yes 2.25 meters Yes 6.8 meters Yes Yes HVD310xA-NOACC HVD-A Probe Accessories HVD310X-NOACC High Voltage Differential Probe PK-HVA-01 PK-HVA-02 PK-HVA-03 PK-HVA-04 PK-HVA-05 PK-HVA-06 PK-HVA-07 PK-HVA-02 Plunger Pincer Clips (Red/Black) 1000 V CAT II HVD310xA / 310xA-6M HVD310X/310X-6M High Voltage Differential Probe PK-HVA-01 PK-HVA-02 PK-HVA-03 PK-HVA-04 PK-HVA-05 PK-HVA-06 PK-HVA-07 HVD3206/3206-6M High Voltage Differential Probe PK-HVA-02 PK-HVA-03 PK-HVA-04 PK-HVA-05 PK-HVA-06 HVD3605 High Voltage Differential Probe PK-HVA-02 PK-HVA-03 PK-HVA-04 PK-HVA-05 PK-HVA-06 PK-HVA-05 Spade Terminals (Red/Black) 1000 V CAT III PK-HVA-06 6 KV Safety Alligator Clips (Red/Black) 6000 V CAT I PK-HVA-07 HVD3605A PK-HVA-01 PK-HVA-03 Plunger Hook Clips (Red/Black) 1000 V CAT II PK-HVA-04 Plunger Alligator Clips (Red/Black) 1000 V CAT III HVD3206A / 3206A-6M PK-HVA-01 PK-HVA-01 Safety Alligator Clips (Red/Black) 1000 V CAT III PK-HVA-07 2 kV Plunger Alligator Clips (Red/Black) 2000 V CAT I PK-HVA-07 29 HIGH VOLTAGE DIFFERENTIAL PROBES Teledyne LeCroy High Voltage Differential Probe Model Numbers: HVD3102A HVD3106A HVD3106A-6M HVD3206A HVD3206A-6M HVD3605A AP031 Ordering Information 30 Product Description Product Code 1 kV, 25 MHz High Voltage Differential Probe with 2 m cable 1 kV, 120 MHz High Voltage Differential Probe with 2 m cable 1 kV, 80 MHz High Voltage Differential Probe with 6 m cable 1 kV, 25 MHz High Voltage Differential Probe with 2 m cable without tip Accessories 1 kV, 120 MHz High Voltage Differential Probe with 2 m cable without tip Accessories 2 kV, 120 MHz High Voltage Differential Probe with 2 m cable 2 kV, 80 MHz High Voltage Differential Probe with 6 m cable 6 kV, 100 MHz High Voltage Differential Probe with 6 m cable High Voltage Replacement Accessories Kit (Includes 2 each, 1 Black, 1 Red): Safety Alligator Clips, Plunger Pincer Clips, Plunger Hook Clips, Plunger Alligator Clips, Spade Terminals HVD3102A HVD3106A HVD3106A-6M HVD3102A-NOACC HVD3106A-NOACC HVD3206A HVD3206A-6M HVD3605A PK-HV-001 HIGH VOLTAGE DIFFERENTIAL PROBES AP031 The AP031 is a low cost, battery operated active differential probe intended for measuring higher voltages. The differential techniques employed permit measurements to be taken at two points in a circuit without reference to the ground, allowing the oscilloscope to be safely grounded without the use of opto-isolators or isolating transformers. Key Features * * * * Safe floating measurements 15 MHz bandwidth 700 V maximum input voltage Works with any 1 M input oscilloscope Specifications Attenuation Bandwidth Input R Differential Mode Range Common Mode Range CMRR /10 / /100 15 MHz 4 M 70 V / 700 V DC + Peak AC 700 V DC + Peak AC 86 dB @ 50 Hz Ordering Information Product Description 700 V, 15 MHz Differential Probe (/10, /100) Product Code AP031 31 DIFFERENTIAL AMPLIFIERS Differential amplifiers are intended to act as signal conditioning preamplifiers for oscilloscopes and network and spectrum analyzers, providing differential measurement capability to instruments having only a single-ended input. The "-PR2" version of each amplifier is a dual channel unit. The DXC series differential input cables are matched to the characteristics of the amplifier. 32 Teledyne LeCroy Differential Amplifier and Accessory Model Numbers: DA1855A DA1855-PR2 DA1855A-RM DA1855A-PR2-RM DXC5100 DXC100A DXC200 DA101 Opposite page: DA1855A Differential Amplifier working with the HDO6000A oscilloscope for power measurement. 33 DIFFERENTIAL AMPLIFIERS Teledyne LeCroy Differential Amplifier and Accessory Model Numbers: DA1855A DA1855-PR2 DA1855A-RM DA1855A-PR2-RM DXC5100 DXC100A DXC200 DA101 DA1855A The DA1855A is a stand-alone, high- in proportion to their attenuation ratio performance 100 MHz differential but do not exceed their maximum input amplifier. It is intended to act as a voltage rating. Effective gain of the signal conditioning preamplifier for DA1855A, including probe attenuation, oscilloscopes, digitizers and spectrum amplifier gain and attenuator settings, is analyzers, providing differential automatically displayed. measurement capability to instruments having only a single-ended input. When used with a DA1855A, oscilloscopes can obtain Common Mode Rejection Ratio (CMRR) and overdrive recovery performance levels previously unobtainable. 34 The DA1855A features a built-in Precision Voltage Generator (PVG) that can be set to any voltage between 15.5 V (10 V in Differential Offset) with up to 100 V resolution. The PVG's output can be selected as an input to the inverting (-) input of the amplifier for Amplifier gain can be set to 1 or operation as a differential comparator, 10 A built-in input attenuator can be or applied internally as a true separately set to attenuate signals by differential offset voltage independent a factor of 10, providing gains of 10, of oscilloscope offset. The differential 1, or 0.1 and common mode dynamic amplifier is also available in a 2 channel range of 15.5 V (/1) or 155 V (/10). model. In addition, a rackmount is Optional probes increase the maximum available for each model for easy input signal and common mode ranges installation with other instruments. DIFFERENTIAL AMPLIFIERS DXC100A /100 or /10 Selectable, 250 MHz Passive Differential Probe Pair *DC to 100 MHz Bandwidth with DA1855A DC to 10 MHz Bandwidth with DA1822 * Max Input Voltage 500 V *Selectable 10 or 100 Attenuation Factor * 1.2 m Cable Length DXC200 /1, 50 MHz, Passive Differential Probe Pair *DC to 50 MHz with DA1855A DC to 10 MHz with DA1822A *Max Input Voltage 500 V (Limited to Amplifier Max Input Voltage) * x1 Differential Probe Pair * 0.7 m Cable Length DXC5100 /100, 2.5KV Passive High Voltage Probe Pair. Requires DA101 for full performance DA101 /10, 1M Passive Attenuator for DXC series probes Ordering Information Product Description Product Code 1 Ch, 100 MHz Differential Amplifier with Precision Voltage Source 2 Ch,100 MHz Differential Amplifier with Precision Voltage Source DA1855A with Rackmount DA1855A with Rackmount (must be ordered at time of purchase, no retrofit) /100 or /10 Selectable, 250 MHz Passive Differential Probe Pair /1, 50 MHz Passive Differential Probe Pair /100, 250 MHz 2.5 kV, High Voltage Probe Pair (requires DA101 for full performance) /10 1 M Passive Attenuator for DXC Series Probes DA1855A DA1855A-PR2 DA1855A-RM DA1855A-PR2-RM DXC100A* DXC200* DXC-5100* DA101* *Must be used with DA Series Differential Amplifiers 35 HIGH VOLTAGE PROBES 36 36 HIGH VOLTAGE PROBES High voltage probes are suitable for a wide range of applications where high-voltage measurements must be made safely and accurately. There are several fixed attenuation probes covering a range from 1 kV to 6 kV and varying transient overvoltage ratings. All of these high voltage probes feature a spring loaded probe tip and a variety of standard accessories to make probing high voltages safe and easy. Additionally, all of the high voltage probe have a probe sense pin to automatically configure the Teledyne LeCroy High Voltage Probe Model Numbers: HVP120 PPE4KV PPE5KV PPE6KV oscilloscope for use with the probe. Opposite page: PPE Series High Voltage Probe 37 HIGH VOLTAGE PROBES The HVP120 is a high voltage passive probe designed for probing up to 1,000 Vrms and capable of handling up to 6,000 V peak transients. Its fast rise time and excellent frequency response make it suitable for a wide variety of high voltage measurement applications. The HVP120 features a spring loaded probe tip and a variety of standard accessories to make probing high voltages safe and easy. Electrical Characteristics Teledyne LeCroy High Voltage Probe Model Number: HVP120 Bandwidth Risetime (10% - 90%) Maximum Input Voltage* Measurement Category II Measurement Category I Pollution Degree* Input Capacitance Compensation Range Attenuation Ratio Environmental Temperature (Operating) Temperature (Non-Operating) Humidity (Operating) Altitude (Operating) Altitude (Non-Operating) General Characteristics Weight (probe) Cable Length Probe Tip Diameter * As defined in IEC 61010-031 400 MHz 900 ps (typical) 1000 Vrms 4000V Transient Overvoltage at 1000 Vrms 6000V Transient Overvoltage at 0 Vrms 2 7.5 pF (typical) 10 pF - 50 pF (typical) 100:1 2% 0C to 50C -40C to 71C 80% RH (Non-Condensing) up to 31C, decreasing linearly to 40% RH at 50C up to 2,000 m up to 15,000 m 67 g (0.15 lbs) 2 m (6.56 ft) 5 mm (0.20 inches) Ordering Information Product Description 400 MHz, High Voltage Passive Probe High Voltage Replacement Accessories Kit Product Code HVP120 PK-HV-002 Replacement Accessories One of each of the following accessories are included with the HVP120. Replacement quantities are listed below. Coding Rings (set) 4 Colors (Qty 3 also included standard) Ground Lead 22 cm to 4 mm Banana plug (Qty 1) Solid Tip 0.8 mm (Qty 5) Spring Tip 0.8 mm (Qty 5) BNC Adapter 5.0-L (Qty 1) Insulating Cap 5.0-L (Qty 1) Protection Cap 5.0-L (Qty 1) Sprung Hook 5.0-L (Qty 1) Adjustment Tool T (Qty 1) Flexible Adapter 5.0-L (Qty 1) Safety Alligator Clip red (Qty 1) Ground Lead 22 cm (Qty 1) 38 PK1-5MM-106 PK1-5MM-122 PK1-5MM-125 PK1-5MM-126 PK1-5MM-127 PK1-5MM-128 PK1-5MM-129 PK1-5MM-130 PK1-5MM-131 PK1-5MM-132 PK1-5MM-133 PK1-5MM-134 HIGH VOLTAGE PROBES The PPE series includes four fixed-attenuation probes covering a range from 2 kV to 6 kV, and one switchable probe providing /10//100 attenuation for voltage inputs up to 1.2 kV. All fixed-attenuation, standard probes automatically rescale compatible Teledyne LeCroy oscilloscopes for the appropriate attenuation of the probe. PPE High-Voltage Probes Selection Guide Specifications Types PPE4kV* PPE5kV* PPE6kV* Bandwidth Input R Input C Attenuation (MHz) () (pF) 400 50 M <6 /100 400 50 M <6 /100 400 50 M <6 /1000 Maximum Voltage 4 kV 5 kV 6 kV Probe Cable Encoding Yes 2m Yes 2m Yes 2m Teledyne LeCroy High Voltage Probe Model Numbers: PPE4KV PPE5KV PPE6KV Trimming Tool Security Ground Lead Ground Lead (22 cm) Flexible 4 mm Security Adapter BNC Adapter Insulating Tip IC Insulating Tip Straight Tip (0.8 mm) Spring Contact Tip (0.8 mm) Sprung Hook Crocodile Clip (Black) Crocodile Clip (Red) Ordering Information Product Description /100; 400 MHz; 50 M High-Voltage Probe, 4 kV max. Voltage DC and Peak AC /100; 400 MHz; 50 M High-Voltage Probe, 5 kV max. Voltage DC and Peak AC /1000; 400 MHz; 50 M High-Voltage Probe, 6 kV max. Voltage DC and Peak AC Accessory Kit for PPE1.2kV, 2kV, 4kV, 5kV, and 6kV Sprung Hook (red) Ground Lead (22 cm) Crocodile Clip Probe Tip to BNC Adapter Spring Tip (0.8 mm) Rigid Tip V2A Product Code PPE4KV PPE5KV PPE6KV PK103 PK103-1 PP005-GL22 PK30x-2 PP005-BNC PP005-ST8 PP005-RT Supplied with probe: * Probe Kit: Trimming tool, ground lead, rigid tip, IC insulator, BNC adapter, tip insulator, spring hook, red crocodile clip. 4 mm safety ground lead, and green/yellow crocodile clip. 39 HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES 40 HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES The HVFO is an affordable, optimally designed probe for measurement of small signals floating on an HV bus in power electronics designs or for EMC, EFT, ESD, and RF immunity testing sensor monitoring. It far surpasses the measurement capabilities and signal fidelity of both conventional Teledyne LeCroy Probe Adapter Model Numbers: HVFO103 HV differential probes and acquisition systems that rely on galvanic high voltage isolation. Furthermore, it mitigates the need to rely on dangerous test setups that require floating the oscilloscope and probe. Opposite page: High Voltage Fiber Optically-isolated Probe HVFO103 working with an HDO8000A High Definition Oscilloscope. 41 HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES The HVFO is an affordable, optimally designed probe for measurement of small signals floating on an HV bus in power electronics designs or for EMC, EFT, ESD, and RF immunity testing sensor monitoring. It far surpasses the measurement capabilities and signal fidelity of both conventional HV differential probes and acquisition systems that rely on galvanic high voltage isolation. Furthermore, it mitigates the need to rely on dangerous test setups that require floating the oscilloscope and probe. Key Features Teledyne LeCroy High Voltage Fiber Optically-isolated Probe Model Number: HVFO103 Applications Upper-side gate drive signal measurements Floating control signal or sensor voltage measurements EMC, EFT, ESD, and RF immunity testing and system optimization Any small signal measurements with high common-mode voltage * * * * 60 MHz bandwidth 35 kV common-mode voltage rating (fiber optic isolation) Superior Noise and Rejection 140 dB CMRR Low loop inductance Low attenuation * * * Reduced DUT loading, better pulse response compared to conventional HV differential probes Selectable tips from 1V to 40V Eliminates need to "float" the oscilloscope ProBus-compatible with many Teledyne LeCroy oscilloscopes 42 HIGH VOLTAGE FIBER OPTICALLY-ISOLATED PROBES Bandwidth Rise Time (10-90%) Input Dynamic Range Electrical 60 MHz (typical, with tip attached) 7.5 ns (typical) 1V, 5V, 20V, 40V (DC+peak AC) respectively with 1X, 5X, 10X or 20X attenuating tips. All tips are purchased as accessories (none are included with HVFO103 probe). Maximum Non-destruct Voltage 5 times the operating voltage rating (tip dependent) Common Mode Voltage Range 35 kV (DC+Peak AC) (not for hand-held use, user must maintain adequate spacing between floating probe components and earth ground.) Maximum Input Voltage to Earth 35 kV (DC+Peak AC) (not for hand-held use, user must maintain adequate spacing between floating probe components and earth ground.) Maximum Safe Input Voltage For hand-held use, 30 Vrms / 60 Vdc per IEC/EN 61010-031 Ed. 2.0 b:2015 Offset Offset capability determined by oscilloscope offset available in a given gain (V/div) setting after accounting for total probe attenuation (total probe attenuation is twice the tip attenuation). Sensitivity 50 mV/div to 1 V/div (1X tip), 250 mV/div to 5 V/div (5X tip), 1 V/div to 20 V/div (20X tip), 2 V/div to 40 V/div (40X tip) Gain Accuracy 2% (LF, guaranteed) Input Impedance 1 M || 34 pF (1X tip); 5 M || 26 pF (5X tip); 10 M || 22 pF (20X tip); 10 M || 22 pF (40X tip) Input/Output Coupling DC only Interface Cable Length Battery CMRR (typical) Noise (Probe only) Temperature Humidity Altitude Pollution Degree ProBus 1.25 m (4.1 feet) from input lead to oscilloscope connection (using included 1 meter fiber optic cable) 6 hour battery life (typical). 1.5 hour re-charge time (typical, with user-supplied dedicated USB charger). 3 hour re-charge time (typical) using supplied USB charging cable connected to oscilloscope USB port Noise and Rejection 140 dB (100 Hz), 120 dB (to 1 MHz), 85 dB (to 10 MHz), 60 dB (to 60 MHz) 7 mVrms (1X tip), 35 mVrms (5X tip), 140 mVrms (20X tip), 280 mVrms (40X tip) Environmental 0C to 50C (operating), -20C to 70C (non-operating) 5% to 80% RH (non-condensing) up to 30C, decreasing linearly to 45% RH at 50C (operating) 5% to 95% RH (Non-Condensing), 75% RH above 30C, 45% RH above 40C (non-operating) 3000 m (operating), 10,000 m (non-operating) 2, Indoor Use Only Certifications CE (LVD Directive 2006/95/EC) IEC/EN 61010-031/A1:2008, Pending IEC/EN 61010-031:2015 CE (EMC Directive 2004/108/EC) IEC/EN 61326-1:2013 uL Listed UL 61010-031 (First Edition), Pending UL 61010-031 (Second Edition) cUL Listed CAN/CSA - C22.2 No. 61010-031-07, Pending CAN/CSA-C22.2 No. 61010-031-15 Compatible With... Compatibility Fully compatible with HDO4000 Series, HDO6000 Series, HDO8000 Series, MDA800 Series, HDO9000 Series, WaveRunner 8000 Series, WaveRunner 6 Zi Series, WavePro 7 Zi Series, and WaveMaster 8 Zi Series. Ordering Information Product Description High Voltage Fiber Optically-isolated Probe Models and Accessories High Voltage Fiber Optic Probe, 60 MHz Bandwidth. Includes soft-carrying case, Qty. 1 Amplifier/Modulating Transmitter, Qty. 1 Demodulating Receiver, Qty. 1 1m Fiber Optic Cable, Qty. 1 USB Charging Cable, Qty. 1 Micro-gripper set. Attenuating Tips must be ordered separately. 1V (1x) Attenuating Tip Accessory 5V (5x) Attenuating Tip Accessory 20V (20x) Attenuating Tip Accessory 40V (40x) Attenuating Tip Accessory Spare Amplifier/Modulating Transmitter (permits constant operation - charge one while another is being used) 1m Spare Fiber Optic Cable Accessory 2m Fiber Optic Cable Accessory 6m Fiber Optic Cable Accessory NIST Traceable Calibration Certificate Product Code HVFO103 HVFO100-1X-TIP HVFO100-5X-TIP HVFO100-20XTIP HVFO100-40X-TIP HVFO103-XMITTER HVFO-1M-FIBER HVFO-2M-FIBER HVFO-6M-FIBER HVFO103-CCNIST 43 OPTICAL-TO-ELECTRICAL CONVERTERS 44 OPTICAL-TO-ELECTRICAL CONVERTERS Teledyne LeCroy's wide-band multi-mode optical-to-electrical converters are designed for measuring optical communications signals. Their broad wavelength range and multi-mode input optics make these devices ideal for applications including Ethernet, Fibre Channel, and ITU telecom standards. Available to support optical data rates up to 11.3 Gb/s with reference receivers, or slightly higher without reference receivers. These wide- band multi-mode optical-to-electrical converters are designed for measuring optical communications signals. They connect to Teledyne Teledyne LeCroy Optical Probe Model Numbers: OE6250G-M OE695G OE425 OE455 OE525 OE555 LeCroy real-time oscilloscopes and provide capability for physical layer signal assessment using a variety of oscilloscope tools, such as SDAIII-CompleteLinQ Serial Data Eye, Jitter, Noise and Crosstalk Analysis, mask testing, serial triggering and decoding, and other compliance and debug tools. Maximum data rate test capability is >11.317 Gb/s with reference receiver, or 12.5 Gb/s without. Opposite page: OE6250G-M Optical Probe working with the LabMaster 10 Zi-A oscilloscope. 45 OPTICAL-TO-ELECTRICAL CONVERTERS Teledyne LeCroy Optical Probe Model Numbers: OE6250G-M OE695G OE425 OE455 OE525 OE555 OE6250G-M The OE6250G optical-to-electrical converter enables optical signal measurement of intensity-modulated signals up to 28 Gbaud and beyond on LabMaster or WaveMaster series real-time oscilloscopes. As a fully calibrated module, the OE6250G-M integrates seamlessly into the oscilloscope software to give optical intensity measurement straight out of the box. Teledyne LeCroy's extensive toolset includes powerful analysis tools for NRZ, PAM4, and other signal types, and Key Features * Optical-to-electrical converter for intensity-modulated signals to 28 Gbaud and higher - Up to 25 GHz bandwidth with a 4th-order Bessel-Thomson frequency response - Up to 36 GHz bandwidth with a flat frequency response * DC-coupled detector for accurate signal reproduction with a real-time oscilloscope * Fully calibrated and integrated * 50/125 m multi-mode fiber input * Ideal for Eye Mask, Extinction Ratio, and Optical Modulation Amplitude (OMA) testing 46 enables custom signal processing and reference receiver implementation. OE6250G-M Specifications Analog Bandwidth Wavelength Range Calibration Wavelengths Conversion gain at 850nm Conversion gain at 1310nm Conversion gain at 1550nm Electrical output coupling 5% compression point at 1550nm Noise measured up to 50GHz Optical Return Loss Polarization dependent loss at 1550 nm RF impedance Fiber (core/cladding) RF connector Optical Connector Typical 25 GHz (Bessel-Thomson response mode), 36 GHz (Flatness response mode) 830nm - 1600nm 850nm, 1310nm, 1550nm -80 V/W -125 V/W -125 V/W DC coupled 4 mW (minimum) 500 uV RMS 19 dB 0.1 dB 50 50/125 m 2.92 mm FC/PC or SC/PC Note: All specifications subject to change without notice. OPTICAL-TO-ELECTRICAL CONVERTERS OE695G OE425/OE455/OE525/OE555 The OE695G wide-band optical-to-electrical converter is The O/E converters contain calibration data that can be ideal for measuring optical datacom and telecom signals used to create optical reference receivers for SONET/ with data rates from 622 Mb/s to 12.5+ Gb/s. Connection SDH (up to OC48/STM16), Fibre Channel, Gigabit Ether- to a real-time Teledyne LeCroy oscilloscope is through the net, and other optical standards. This feature is available 2.92 mm interface, with a provided adapter to connect to when the O/E is used on a supported oscilloscope. The ProLink interfaces. universal reference receiver supports any data rate up to 3 GHz and remains calibrated on any channel of the Key Features * Compatible with LabMaster 10 Zi oscilloscopes * Frequency range DC to 9.5 GHz (electrical, -3 dB) * Reference receiver support from 8GFC to 10GFC FEC, or Custom (<12.5Gb/s) * Full bandwidth mode (no reference receiver applied) * 62.5/125 m multi-mode or single-mode fiber input * Broad wavelength range (750 to 1650 nm) * +7 dBm (5 mW) max peak optical power * Low noise (as low as 25 pW/Hz) * Ideal for Eye Mask, Extinction Ratio, and Optical oscilloscope. Key Features * Frequency range to 5 GHz (6 GHz optical) *62.5 m or narrower multi-mode or single-mode * fiber input Broad wavelength range: - 500-870 nm (OE425, OE525) - 950-1630 nm (OE455, OE555) * High responsivity * Low noise *Included Accessories: Multi-mode optical fiber jumper FC-FC FC to ST adapter FC to SC adapter Modulation Amplitude (OMA) testing Ordering Information Product Description Optical-to-Electrical Converter, DC to 36 GHz, 830 to 1600nm Optical-to-Electrical Converter, 785 to 1550 nm, 2.92 mm connector with ProLink adapter Optical-to-Electrical Converter, 500-870 nm ProBus BNC Connector Optical-to-Electrical Converter, 950-1630 nm ProBus BNC Connector Optical-to-Electrical Converter, 500-870 nm ProLink BMA Connector Optical-to-Electrical Converter, 950-1630 nm ProLink BMA Connector Product Code OE6250G-M OE695G OE425 OE455 OE525 OE555 47 PASSIVE PROBES 48 PASSIVE PROBES Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a /10 attenuation and feature a high input resistance of 10 M. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400 V, some as high as 600 V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input. Teledyne LeCroy Passive Probe Model Numbers: PP006C PP016 PP019 PP020 PP021 PP022 PP023 PP024 PP025 PP026 49 6C PASSIVE PROBES Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe can be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies. Specifications Teledyne LeCroy PassiveAccessories Probe Std. Model Numbers: PP006C PP016 PP019 PP020 PP021 PP022 PP023 PP024 PP026 Types Bandwidth Input R Input C Attenuation Maximum Voltage PP006C 500 MHz 10 M 12 pF /10 500 V PP016 10 M/ 300 MHz/ 12 pF/ /10/ 600 V 10 MHz 1 M 46 pF /1 PP019 200 MHz 10 M 12 pF /10 500 V 10 M 11 pF /10 500 V PP020 500 MHz PP021 500 MHz 10 M 11 pF /10 500 V PP022 500 MHz 10 M 10 pF /10 500 V PP023 500 MHz 10 M 10 pF /10 500 V PP024 500 MHz 10 M 10 pF /10 500 V PP025 500 MHz 10 M 10 pF /10 500 V PP026 500 MHz 10 M 10 pF /10 500 V Passive Probe Accessories for PP006C Replacement Part Kit: PK116 Diameter 5 mm 5 mm 5 mm 5 mm 2.5 mm 2.5 mm 2.5 mm 5 mm 5 mm 5 mm Passive Probe Accessories for PP016 Replacement Part Kit: PKIT3-5MM-101 Trimmer Tool Set Coding Rings 2x4 colors Color Coding Rings (set) Ground Lead PK116-2 Ground Lead Trimmer Tool PK116-1 Sprung Hook Sprung Hook Rigid Tip PK116-3 Ground Spring BNC Adapter IC Insulating Tip Ground Spring Tip Insulator 50 IC Tip Insulator PASSIVE PROBES Passive Probe Accessories for PP019 and PP020 - Part numbers in blue Replacement Part Kit: PKIT4-5MM-101 PP024, PP025, and PP026 - Part numbers in gray Replacement Part Kit: PKIT6-5MM-101 Passive Probe Accessories for PP021, PP022, and PP023 Replacement Part Kit: PKIT5-2.5MM-101 PK5-PK6-001 Trimmer Tool PK4-5MM-5 PK5-PK6-001 Trimmer Tool PK5-PK6-002 Color Coding Rings (set) PK4-5MM-8 PK5-PK6-002 Color Coding Rings (set) PK5-2.5MM-111 PK4-5MM-2 PK6-5MM-103 Ground Lead with Alligator Clip Swivel Ground Lead Adapter PK5-2.5MM-105 Long Collar PK6-5MM-107 Spring Tip PK5-2.5MM-103 Short Collar PK4-5MM-4 PK6-5MM-101 Rigid Probe Tip PK6-5MM-108 Probe Tip Cover PK6-5MM-105 PCB Adapter PK5-2.5MM-101 Ground Lead with Alligator Clip PK4-5MM-1 PK6-5MM-102 Sprung Hook PK5-2.5MM-109 BNC Adapter 2.5mm PK5-2.5MM-104 Sprung Hook PK4-5MM-3 PK6-5MM-106 BNC Adapter 5mm PK5-2.5MM-113 PCB Adapter PK4-5MM-6 PK6-5MM-109 IC Tip Insulator PK5-2.5MM-110 Swivel Ground Lead PK5-2.5MM-112 Ground Spring PK4-5MM-7 PK6-5MM-110 Tip Insulator PK5-2.5MM-106 IC Tip Insulators (Black, Brown, Blue, Green, Gray) PK4-5MM-9 PK6-5MM-104 Ground Spring PK5-2.5MM-107 Tip Insulator 2.5mm Cap PK6-5MM-108 Probe Tip Cover PK5-2.5MM-102 Rigid Probe Tip Ordering Information Product Description Product Code 500 MHz Passive Probe for WaveJet Touch, 10:1, 10 M 10:1, 10 M, 300 MHz Passive Probe 250 MHz Passive Probe for WaveSurfer 3000, 10:1, 10 M 500 MHz Passive Probe for WaveSurfer 3000, 10:1, 10 M 500 MHz Passive Probe, 2.5mm, 10:1, 10 M 500 MHz Passive Probe, 2.5mm, 10:1, 10 M 500 MHz Passive Probe, 2.5mm, 10:1, 10 M 500 MHz Passive Probe, 5mm, 10:1, 10 M 500 MHz Passive Probe, 5mm, 10:1, 10 M 500 MHz Passive Probe, 5mm, 10:1, 10 M PP006C PP016 PP019 PP020 PP021 PP022 PP023 PP024 PP025 PP026 PK5-2.5MM-114 Spring Tip PK5-2.5MM-108 Probe Tip Cover 51 PROBE ADAPTERS Probe adapters provide simple and easy interface of third-party probes as well as change between the different Teledyne LeCroy Oscilloscope input and cable types (ProBus, ProLink, K/2.92 mm, BNC and SMA). Depending on the adapters, changing between the Teledyne LeCroy Oscilloscope's input type may have an effect on the overall performance of the channel. Teledyne LeCroy Probe Adapter Model Numbers: CA10 TPA10 CA10 Key Features * * * * * Provides ability for third party current sensor to operate like a Teledyne LeCroy probe P rogrammable EEPROM for saving third party current sensor parameters A llows for addition of shunt resistor and RLC filter components ProBus Active interface with automatic scaling in A/div Easy to use, saves time and possible errors The CA10 is a programmable and customizable interface device that seamlessly incorporates third party current transducers/transformers with Teledyne LeCroy oscilloscopes or motor drive analyzers. The easy to use interface provides the ability for the CA10 to be programmed to contain the specifications of the current sensor allowing it to automatically correct for the gain or attenuation and display results in Ampere units. This allows the third party device to be recognized and operate as if it were a Teledyne LeCroy probe. Specifications Input Coupling Input Termination Programmable Bandwidth Filters Transformer/Transducer Interface Scaling Factors Resistive Termination (if required) Oscilloscope Interface DC, AC, Both 1M or 50 Full, 200 MHz, 20 MHz BNC Programmable Customizable (See Operator's Manual for details) Teledyne LeCroy ProBus Note: Some third party devices will require a separate power supply or batteries. The CA10 does not have the ability to supply the power to these devices. Ordering Information Product Description ProBus Current Sensor Adapter Set of 4 CA10, ProBus Current Sensor Adapter Product Code CA10 CA10-QUADPAK Included with Standard Configuration CA10 Description CA10 ProBus Current Adapter Heat-Shrink tubing (6" length) Removable Labels (sheet of 20) 52 Qty 1 1 1 PROBE ADAPTERS Key Features * Allows TekProbeTM interface level II probes to work with any ProBus-equipped Teledyne LeCroy * * * * * TPA10 The TPA10 ProBusTM Probe Adapter enables you to connect select TekProbe interface level II probes to any ProBus-equipped Teledyne LeCroy instrument. The TPA10 supplies all necessary power and offset control to the probe and automatically detects which probe is attached. Specifications Electrical Characteristics Bandwidth Power Supplies Offset Voltage Max. Input Voltage A utomatic probe detection P rovides all necessary power and offset control to the attached probe S upports probes up to 4 GHz E asy firmware updates W ide variety of probes supported including: Preamplifiers Current Probes Single-Ended Active Probes Differential Active Probes - - - - Ordering Information 4 GHz (adapter only) +15V, -15V, +5V, -5V (each 2%) 1V (1%) 47 Vpk, 33 Vrms Environmental Operating Temperature Range 0 to 50 C Non-operating Temperature Range -40 to +70 C Humidity 5% to 95% RH (10 to 40 C); 5% to 75% (above 40 C); RH not controlled below 10 C Operating Altitude 3000 meters maximum Physical oscilloscope Product Description TPA10 ProBus Adapter Set of 4 TPA10, TPA10 ProBus Adapters 39 mm x 31.1 mm x 88.6 mm (1.54" x 1.22" x 3.49") Weight 119 g (0.26 lb) The TPA10 requires the Teledyne LeCroy oscilloscope to be running firmware version 7.8.0.0 or greater. TPA10 TPA10-QUADPAK Supported Probes The following TekProbe devices are supported for use with TPA10: Preamplifiers 1 MHz Differential Preamplifier Current Probes 50 MHz AC/DC Current Probe Dimensions (WxHxD) Product Code Single-ended Active Probes 750 MHz Single-ended Active Probe 1 GHz Single-ended Active Probe 1.5 GHz Single-ended Active Probe 4 GHz Single-ended Active Probe 4 GHz Single-ended Active Probe Differential Active Probes 100 MHz Differential Probe 50 MHz Differential Probe 400 MHz Differential Probe 1 GHz Differential Probe 1.5 GHz Differential Probe 500 MHz Differential Probe 1 GHz Differential Probe ADA400A TCP202/TCP202A P6205 P6243 P6245 P6241 P6249 P5205/P5205A P5210/P5210A P6246 P6247 P6248 P6250 P6251 53 TRANSMISSION LINE PROBES Transmission line probes are a special type of passive probe designed for use at very high frequencies. They replace the high impedance probe cable found in a traditional passive probe with a precision transmission line, with a characteristic impedance that matches the oscilloscope input (50 ). This greatly reduces the input capacitance to a fraction of a picofarad, minimizing the loading of high frequency signals. A matching network at the tip increases the DC input resistance. While they have lower DC input resistance than a traditional passive probe (usually 500 to 5 k), the input impedance of these probes remains nearly constant over their entire frequency range. A traditional /10 passive probe will have a 10 M input impedance at DC, however this impedance drops rapidly Teledyne LeCroy Transmission Line Probe Model Number: PP066 with frequency, passing below the input impedance of a transmission line probe at less than 100 MHz. In some applications, transmission line probes offer advantages over active probes. In addition to being less expensive, their passive design is more robust to over voltage and ESD exposure. They are useful in applications producing fast rising, narrow pulses with amplitudes which exceed the dynamic range of active probes. They also tend to have less parasitic effects on frequency response. 54 TRANSMISSION LINE PROBES PP066 The PP066 is a high-bandwidth passive probe designed for use with the WaveMaster and other high-bandwidth oscilloscopes with 50 input termination. This very low capacitance probe provides an excellent solution for higher frequency applications, especially the probing of transmission lines with 20-100 impedance. The PP066 accommodates a wide range of applications, including probing of analog and digital ICs commonly found in computer, communications, data storage, and other high-speed designs. Key Features: * * * * Interchangeable attenuator tips Signal integrity at high bandwidth Standard SMA cable connection Ultra low capacitance PP066 Specifications Electrical Characteristics Bandwidth DC to 7.5 GHz Risetime < 47 ps Input Capacitance < 0.20 pF Input Resistance500 (/10 cartridge) 1000 (/20 cartridge) Maximum Voltage 15 V rms Cable Length 1m Ordering Information Product Description 7.5 GHz Low Capacitance Passive Probe (/10, 1 k; /20, 500 ) Product Code PP066 Included with PP0066 PACC-AD001, SMA to BNC Adapter 55 1-800-5-LeCroy teledynelecroy.com Local sales offices are located throughout the world. Visit our website to find the most convenient location. (c) 2018 Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice. Product or brand names are trademarks or requested trademarks of their respective holders. tlec_probecatalog-14may18