Test Configurations
TO OSCILLOSCOPE CURRENT PROBE
LTEST
12μH
BATTERY
CS 220μF
E.S.R.<0.1
@ 20°C 100kHz
33μF
Vin+
Vin-
NOTE: Measure input reflected ripple current with a simulated
source inductance (LTEST) of 12μH. Capacitor CS offsets
possible battery impedance. Measure current as shown
above.
Figure 61. Input Reflected Ripple Current Test Setup.
NOTE: All voltage measurements to be taken at the module
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
V
O
(+)
V
O
(
–
)
1uF
.
RESI STI V E
LO A D
SC O PE
COPPER STRIP
GROUND PLANE
10uF
Figure 62. Output Ripple and Noise Test Setup.
Vout+
Vout-
Vin+
Vin-
RLOAD
Rcontact Rdistribution
Rcontact Rdistribution
Rcontact
Rcontact
Rdistribution
Rdistribution
VIN VO
NOTE: All voltage measurements to be taken at the module
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
Figure 63. Output Voltage and Efficiency Test Setup.
=
VO. IO
VIN. IIN
x 100 %
Efficiency
Design Considerations
Input Source Impedance
The power module should be connected to a low
ac-impedance source. A highly inductive source impedance
can affect the stability of the power module. For the test
configuration in Figure 61, a 33μF electrolytic capacitor
(ESR<0.7 at 100kHz), mounted close to the power module
helps ensure the stability of the unit. Consult the factory for
further application guidelines.
Safety Considerations
For safety-agency approval of the system in which the
power module is used, the power module must be installed
in compliance with the spacing and separation
requirements of the end-use safety agency standard, i.e.,
UL 60950-1-3, CSA C22.2 No. 60950-00, and VDE
0805:2001-12 (IEC60950-1).
If the input source is non-SELV (ELV or a hazardous voltage
greater than 60 Vdc and less than or equal to 75Vdc), for
the module’s output to be considered as meeting the
requirements for safety extra-low voltage (SELV), all of the
following must be true:
The input source is to be provided with reinforced insulation
from any other hazardous voltages, including the ac mains.
One VIN pin and one VOUT pin are to be grounded, or both the
input and output pins are to be kept floating.
The input pins of the module are not operator accessible.
Another SELV reliability test is conducted on the whole system
(combination of supply source and subject module), as
required by the safety agencies, to verify that under a single
fault, hazardous voltages do not appear at the module’s
output.
Note: Do not ground either of the input pins of the module
without grounding one of the output pins. This may
allow a non-SELV voltage to appear between the
output pins and ground.
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
For input voltages exceeding –60 Vdc but less than or equal
to –75 Vdc, these converters have been evaluated to the
applicable requirements of BASIC INSULATION between
secondary DC MAINS DISTRIBUTION input (classified as
TNV-2 in Europe) and unearthed SELV outputs.
"All flammable materials used in the manufacturing of
these modules are rated 94V-0 and UL60950 A.2 for
reduced thicknesses.
The input to these units is to be provided with a maximum
3A fast-acting fuse in the unearthed lead."
Feature Description
Remote On/Off
Two remote on/off options are available. Positive logic turns
the module on during a logic high voltage on the ON/OFF