TOP242-250 TOPSwitch-GX Family (R) Extended Power, Design Flexible, (R) EcoSmart, Integrated Off-line Switcher Product Highlights Lower System Cost, High Design Flexibility * Extended power range for higher power applications * No heatsink required up to 34 W using P/G packages * Features eliminate or reduce cost of external components * Fully integrated soft-start for minimum stress/overshoot * Externally programmable accurate current limit * Wider duty cycle for more power, smaller input capacitor * Separate line sense and current limit pins on Y/R/F packages * Line under-voltage (UV) detection: no turn off glitches * Line overvoltage (OV) shutdown extends line surge limit * Line feed-forward with maximum duty cycle (DCMAX) reduction rejects line ripple and limits DCMAX at high line * Frequency jittering reduces EMI and EMI filtering costs * Regulates to zero load without dummy loading * 132 kHz frequency reduces transformer/power supply size * Half frequency option in Y/R/F packages for video applications * Hysteretic thermal shutdown for automatic fault recovery * Large thermal hysteresis prevents PC board overheating EcoSmart - Energy Efficient * Extremely low consumption in remote off mode (80 mW at 110 VAC, 160 mW at 230 VAC) * Frequency lowered with load for high standby efficiency * Allows shutdown/wake-up via LAN/input port Description TOPSwitch-GX uses the same proven topology as TOPSwitch, cost effectively integrating the high voltage power MOSFET, PWM control, fault protection and other control circuitry onto a single CMOS chip. Many new functions are integrated to reduce system cost and improve design flexibility, performance and energy efficiency. Depending on package type, either 1 or 3 additional pins over the TOPSwitch standard DRAIN, SOURCE and CONTROL terminals allow the following functions: line sensing (OV/UV, line feed-forward/DCMAX reduction), accurate externally set current limit, remote ON/OFF, synchronization to an external lower frequency, and frequency selection (132 kHz/66 kHz). All package types provide the following transparent features: Soft-start, 132 kHz switching frequency (automatically reduced at light load), frequency jittering for lower EMI, wider DCMAX, hysteretic thermal shutdown, and larger creepage packages. In addition, all critical parameters (i.e. current limit, frequency, PWM gain) have tighter temperature and absolute tolerances to simplify design and optimize system cost. + DC OUT - AC IN L D CONTROL TOPSwitch-GX S X C F PI-2632-060200 Figure 1. Typical Flyback Application. OUTPUT POWER TABLE PRODUCT3 230 VAC 15%4 Adapter1 TOP242 P or G 9 W TOP242 R 15 W TOP242 Y or F 10 W TOP243 P or G 13 W TOP243 R 29 W TOP243 Y or F 20 W TOP244 P or G 16 W TOP244 R 34 W TOP244 Y or F 30 W TOP245 P or G 19 W TOP245 R 37 W TOP245 Y or F 40 W TOP246 P or G 21 W TOP246 R 40 W TOP246 Y or F 60 W 42 W TOP247 R TOP247 Y or F 85 W 43 W TOP248 R TOP248 Y or F 105 W 44 W TOP249 R TOP249 Y or F 120 W 45 W TOP250 R TOP250 Y or F 135 W 85-265 VAC Open Open Adapter1 Frame2 Frame2 15 W 6.5 W 10 W 22 W 11 W 14 W 22 W 7W 14 W 25 W 9W 15 W 45 W 17 W 23 W 45 W 15 W 30 W 28 W 20 W 11 W 50 W 20 W 28 W 65 W 20 W 45 W 30 W 13 W 22 W 57 W 23 W 33 W 85 W 26 W 60 W 34 W 15 W 26 W 64 W 26 W 38 W 125 W 40 W 90 W 70 W 28 W 43 W 165 W 55 W 125 W 75 W 30 W 48 W 205 W 70 W 155 W 79 W 31 W 53 W 250 W 80 W 180 W 82 W 32 W 55 W 290 W 90 W 210 W Table 1. Notes: 1. Typical continuous power in a non-ventilated enclosed adapter measured at 50 C ambient. 2. Maximum practical continuous power in an open frame design at 50 C ambient. See Key Applications for detailed conditions. 3. For lead-free package options, see Part Ordering Information. 4. 230 VAC or 100/115 VAC with doubler. November 2005 TOP242-250 Section List Functional Block Diagram ....................................................................................................................................... 3 Pin Functional Description ...................................................................................................................................... 4 TOPSwitch-GX Family Functional Description ....................................................................................................... 5 CONTROL (C) Pin Operation.................................................................................................................................. 6 Oscillator and Switching Frequency ........................................................................................................................ 6 Pulse Width Modulator and Maximum Duty Cycle .................................................................................................. 7 Light Load Frequency Reduction ............................................................................................................................ 7 Error Amplifier ......................................................................................................................................................... 7 On-Chip Current Limit with External Programmability ............................................................................................ 7 Line Under-Voltage Detection (UV)......................................................................................................................... 8 Line Overvoltage Shutdown (OV) ........................................................................................................................... 8 Line Feed-Forward with DCMAX Reduction .............................................................................................................. 8 Remote ON/OFF and Synchronization ................................................................................................................... 9 Soft-Start ................................................................................................................................................................. 9 Shutdown/Auto-Restart ........................................................................................................................................... 9 Hysteretic Over-Temperature Protection ................................................................................................................. 9 Bandgap Reference .............................................................................................................................................. 10 High-Voltage Bias Current Source ........................................................................................................................ 10 Using Feature Pins ................................................................................................................................................... 10 FREQUENCY (F) Pin Operation ........................................................................................................................... 10 LINE-SENSE (L) Pin Operation ............................................................................................................................ 10 EXTERNAL CURRENT LIMIT (X) Pin Operation .................................................................................................. 11 MULTI-FUNCTION (M) Pin Operation .................................................................................................................. 11 Typical Uses of FREQUENCY (F) Pin ...................................................................................................................... 14 Typical Uses of LINE-SENSE (L) and EXTERNAL CURRENT LIMIT (X) Pins ...................................................... 15 Typical Uses of MULTI-FUNCTION (M) Pin ........................................................................................................... 17 Application Examples .............................................................................................................................................. 20 A High Efficiency, 30 W, Universal Input Power Supply ........................................................................................ 20 A High Efficiency, Enclosed, 70 W, Universal Adapter Supply .............................................................................. 20 A High Efficiency, 250 W, 250-380 VDC Input Power Supply ............................................................................... 22 Multiple Output, 60 W, 185-265 VAC Input Power Supply .................................................................................... 23 Processor Controlled Supply Turn On/Off ............................................................................................................. 24 Key Application Considerations ............................................................................................................................. 26 TOPSwitch-II vs. TOPSwitch-GX .......................................................................................................................... 26 TOPSwitch-FX vs. TOPSwitch-GX ....................................................................................................................... 28 TOPSwitch-GX Design Considerations ............................................................................................................... 28 TOPSwitch-GX Layout Considerations ................................................................................................................. 30 Quick Design Checklist ......................................................................................................................................... 32 Design Tools ......................................................................................................................................................... 32 Product Specifications and Test Conditions ......................................................................................................... 33 Typical Performance Characteristics .................................................................................................................... 40 Part Ordering Information ....................................................................................................................................... 46 Package Outlines ..................................................................................................................................................... 47 2 O 11/05 TOP242-250 VC CONTROL (C) 0 ZC 1 SHUNT REGULATOR/ ERROR AMPLIFIER - 5.8 V + IFB + 5.8 V 4.8 V SOFT START - INTERNAL UV COMPARATOR VI (LIMIT) CURRENT LIMIT ADJUST SOFT START VBG + VT 1V VBG CURRENT LIMIT COMPARATOR HYSTERETIC THERMAL SHUTDOWN STOP LOGIC CONTROLLED TURN-ON GATE DRIVER STOP SOFTSTART DMAX DCMAX CLOCK OV/UV DCMAX HALF FREQ. FREQUENCY (F) + SHUTDOWN/ AUTO-RESTART EXTERNAL CURRENT LIMIT (X) LINE SENSE - /8 ON/OFF LINE-SENSE (L) DRAIN (D) INTERNAL SUPPLY SAW S + OSCILLATOR WITH JITTER Q R LEADING EDGE BLANKING PWM COMPARATOR LIGHT LOAD FREQUENCY REDUCTION RE SOURCE (S) PI-2639-060600 Figure 2a. Functional Block Diagram (Y, R or F Package). VC CONTROL (C) 0 ZC 1 SHUNT REGULATOR/ ERROR AMPLIFIER - 5.8 V + IFB + 5.8 V 4.8 V DRAIN (D) INTERNAL SUPPLY SOFT START - INTERNAL UV COMPARATOR VI (LIMIT) CURRENT LIMIT ADJUST SOFT START + SHUTDOWN/ AUTO-RESTART VBG + VT STOP LOGIC MULTIFUNCTION (M) - /8 ON/OFF CURRENT LIMIT COMPARATOR HYSTERETIC THERMAL SHUTDOWN VBG OV/UV LINE SENSE DCMAX CONTROLLED TURN-ON GATE DRIVER STOP SOFTSTART DMAX DCMAX CLOCK SAW OSCILLATOR WITH JITTER + S R Q LEADING EDGE BLANKING PWM COMPARATOR RE LIGHT LOAD FREQUENCY REDUCTION SOURCE (S) PI-2641-061200 Figure 2b. Functional Block Diagram (P or G Package). O 11/05 3 TOP242-250 DRAIN (D) Pin: High voltage power MOSFET drain output. The internal start-up bias current is drawn from this pin through a switched high-voltage current source. Internal current limit sense point for drain current. CONTROL (C) Pin: Error amplifier and feedback current input pin for duty cycle control. Internal shunt regulator connection to provide internal bias current during normal operation. It is also used as the connection point for the supply bypass and auto-restart/ compensation capacitor. LINE-SENSE (L) Pin: (Y, R or F package only) Input pin for OV, UV, line feed forward with DCMAX reduction, remote ON/OFF and synchronization. A connection to SOURCE pin disables all functions on this pin. EXTERNAL CURRENT LIMIT (X) Pin: (Y, R or F package only) Input pin for external current limit adjustment, remote ON/OFF, and synchronization. A connection to SOURCE pin disables all functions on this pin. MULTI-FUNCTION (M) Pin: (P or G package only) This pin combines the functions of the LINE-SENSE (L) and EXTERNAL CURRENT LIMIT (X) pins of the Y package into one pin. Input pin for OV, UV, line feed forward with DCMAX reduction, external current limit adjustment, remote ON/OFF and synchronization. A connection to SOURCE pin disables all functions on this pin and makes TOPSwitch-GX operate in simple three terminal mode (like TOPSwitch-II). FREQUENCY (F) Pin: (Y, R or F package only) Input pin for selecting switching frequency: 132 kHz if connected to SOURCE pin and 66 kHz if connected to CONTROL pin. The switching frequency is internally set for fixed 132 kHz operation in P and G packages. SOURCE (S) Pin: Output MOSFET source connection for high voltage power return. Primary side control circuit common and reference point. VUV = IUV x RLS VOV = IOV x RLS + DC Input Voltage For RLS = 2 M 2 M RLS VUV = 100 VDC VOV = 450 VDC DCMAX@100 VDC = 78% DCMAX@375 VDC = 38% L D CONTROL S C For RIL = 12 k ILIMIT = 69% X See Figure 54b for other resistor values (RIL) to select different ILIMIT values RIL 12 k - Figure 4. Y/R/F Pkg Line Sense and Externally Set Current Limit. + VUV = IUV x RLS VOV = IOV x RLS RLS DC Input Voltage For RLS = 2 M VUV = 100 VDC VOV = 450 VDC 2 M D DCMAX@100 VDC = 78% DCMAX@375 VDC = 38% M CONTROL C Y Package (TO-220-7C) 7D Tab Internally Connected to SOURCE Pin 5F 4S 3X 2L 1C P Package (DIP-8B) G Package (SMD-8B) M 1 8 S S 2 7 S S 3 C 4 5 R Package (TO-263-7C) F Package (TO-262-7C) D S - PI-2509-040501 Figure 5. P/G Package Line Sense. + For RIL = 12 k ILIMIT = 69% For RIL = 25 k ILIMIT = 43% DC Input Voltage D 7 D PI-2724-010802 - M CONTROL RIL 123 4 5 CL X S F See Figures 54b, 55b and 56b for other resistor values (RIL) to select different ILIMIT values. C S Figure 3. Pin Configuration (top view). PI-2517-022604 Figure 6. P/G Package Externally Set Current Limit. 4 O 11/05 PI-2629-092203 Pin Functional Description TOP242-250 TOPSwitch-GX Family Functional Description Three terminals, FREQUENCY, LINE-SENSE, and EXTERNAL CURRENT LIMIT (available in Y, R or F package) or one terminal MULTI-FUNCTION (available in P or G package) have been added to implement some of the new functions. These terminals can be connected to the SOURCE pin to operate the TOPSwitch-GX in a TOPSwitch-like three terminal mode. However, even in this three terminal mode, the TOPSwitch-GX offers many new transparent features that do not require any external components: 1. A fully integrated 10 ms soft-start limits peak currents and voltages during start-up and dramatically reduces or eliminates output overshoot in most applications. 2. DCMAX of 78% allows smaller input storage capacitor, lower input voltage requirement and/or higher power capability. 3. Frequency reduction at light loads lowers the switching losses and maintains good cross regulation in multiple output supplies. 4. Higher switching frequency of 132 kHz reduces the transformer size with no noticeable impact on EMI. 5. Frequency jittering reduces EMI. 6. Hysteretic over-temperature shutdown ensures automatic recovery from thermal fault. Large hysteresis prevents circuit board overheating. 7. Packages with omitted pins and lead forming provide large drain creepage distance. 8. Tighter absolute tolerances and smaller temperature variations on switching frequency, current limit and PWM gain. The LINE-SENSE (L) pin is usually used for line sensing by connecting a resistor from this pin to the rectified DC high voltage bus to implement line overvoltage (OV), under-voltage (UV) and line feed-forward with DCMAX reduction. In this mode, the value of the resistor determines the OV/UV thresholds and the DCMAX is reduced linearly starting from a line voltage above the under-voltage threshold. See Table 2 and Figure 11. IL = 125 A Frequency (kHz) In addition to the three terminal TOPSwitch features, such as the high voltage start-up, the cycle-by-cycle current limiting, loop compensation circuitry, auto-restart, thermal shutdown, the TOPSwitch-GX incorporates many additional functions that reduce system cost, increase power supply performance and design flexibility. A patented high voltage CMOS technology allows both the high voltage power MOSFET and all the low voltage control circuitry to be cost effectively integrated onto a single monolithic chip. IB 132 IL < IL(DC) IL = 190 A 30 IC (mA) Auto-restart ICD1 IB 78 Duty Cycle (%) Like TOPSwitch, TOPSwitch-GX is an integrated switched mode power supply chip that converts a current at the control input to a duty cycle at the open drain output of a high voltage power MOSFET. During normal operation the duty cycle of the power MOSFET decreases linearly with increasing CONTROL pin current as shown in Figure 7. Auto-restart ICD1 Slope = PWM Gain IL = 125 A 38 IL < IL(DC) 10 IL = 190 A TOP242-5 1.6 2.0 TOP246-9 2.2 2.6 TOP250 2.4 2.7 IC (mA) 5.2 5.8 6.5 6.0 6.6 7.3 Note: For P and G packages IL is replaced with IM. PI-2633-011502 Figure 7. Relationship of Duty Cycle and Frequency to CONTROL Pin Current. The pin can also be used as a remote ON/OFF and a synchronization input. The EXTERNAL CURRENT LIMIT (X) pin is usually used to reduce the current limit externally to a value close to the operating peak current, by connecting the pin to SOURCE through a resistor. This pin can also be used as a remote ON/OFF and a synchronization input in both modes. See Table 2 and Figure 11. For the P or G packages the LINE-SENSE and EXTERNAL CURRENT LIMIT pin functions are combined on one MULTIFUNCTION (M) pin. However, some of the functions become mutually exclusive as shown in Table 3. The FREQUENCY (F) pin in the Y, R or F package sets the switching frequency to the default value of 132 kHz when connected to SOURCE pin. A half frequency option of 66 kHz can be chosen by connecting this pin to CONTROL pin instead. Leaving this pin open is not recommended. O 11/05 5 TOP242-250 CONTROL (C) Pin Operation The CONTROL pin is a low impedance node that is capable of receiving a combined supply and feedback current. During normal operation, a shunt regulator is used to separate the feedback signal from the supply current. CONTROL pin voltage VC is the supply voltage for the control circuitry including the MOSFET gate driver. An external bypass capacitor closely connected between the CONTROL and SOURCE pins is required to supply the instantaneous gate drive current. The total amount of capacitance connected to this pin also sets the auto-restart timing as well as control loop compensation. voltage of 5.8 V, current in excess of the consumption of the chip is shunted to SOURCE through resistor RE as shown in Figure 2. This current flowing through RE controls the duty cycle of the power MOSFET to provide closed loop regulation. The shunt regulator has a finite low output impedance ZC that sets the gain of the error amplifier when used in a primary feedback configuration. The dynamic impedance ZC of the CONTROL pin together with the external CONTROL pin capacitance sets the dominant pole for the control loop. When a fault condition such as an open loop or shorted output prevents the flow of an external current into the CONTROL pin, the capacitor on the CONTROL pin discharges towards 4.8 V. At 4.8 V, auto-restart is activated which turns the output MOSFET off and puts the control circuitry in a low current standby mode. The high-voltage current source turns on and charges the external capacitance again. A hysteretic internal supply under-voltage comparator keeps VC within a window of typically 4.8 V to 5.8 V by turning the high-voltage current source on and off as shown in Figure 8. The auto-restart circuit has a divide-by-eight counter which prevents the output MOSFET from turning on again until eight discharge/charge cycles have elapsed. This is accomplished by enabling the output MOSFET only when the divide-by-eight counter reaches full count (S7). The counter effectively limits TOPSwitch-GX power dissipation by reducing the auto-restart duty cycle to typically 4%. Auto-restart mode continues until output voltage regulation is again achieved through closure of the feedback loop. When rectified DC high voltage is applied to the DRAIN pin during start-up, the MOSFET is initially off, and the CONTROL pin capacitor is charged through a switched high voltage current source connected internally between the DRAIN and CONTROL pins. When the CONTROL pin voltage VC reaches approximately 5.8 V, the control circuitry is activated and the soft-start begins. The soft-start circuit gradually increases the duty cycle of the MOSFET from zero to the maximum value over approximately 10 ms. If no external feedback/supply current is fed into the CONTROL pin by the end of the soft-start, the high voltage current source is turned off and the CONTROL pin will start discharging in response to the supply current drawn by the control circuitry. If the power supply is designed properly, and no fault condition such as open loop or shorted output exists, the feedback loop will close, providing external CONTROL pin current, before the CONTROL pin voltage has had a chance to discharge to the lower threshold voltage of approximately 4.8 V (internal supply under-voltage lockout threshold). When the externally fed current charges the CONTROL pin to the shunt regulator Oscillator and Switching Frequency The internal oscillator linearly charges and discharges an ~ ~ ~ ~ VUV ~ ~ ~ ~ ~ ~ VLINE 0V S6 S7 S0 S1 S2 S6 S0 S7 S1 S2 ~ ~ S2 S6 S7 S7 5.8 V 4.8 V ~ ~ ~ ~ 0V S1 ~ ~ S0 ~ ~ S7 VC ~ ~ VDRAIN 0V VOUT 1 2 3 ~ ~ ~ ~ ~ ~ 0V 2 Note: S0 through S7 are the output states of the auto-restart counter Figure 8. Typical Waveforms for (1) Power Up (2) Normal Operation (3) Auto-Restart (4) Power Down. 6 O 11/05 4 PI-2545-082299 internal capacitance between two voltage levels to create a sawtooth waveform for the pulse width modulator. This oscillator sets the pulse width modulator/current limit latch at the beginning of each cycle. The nominal switching frequency of 132 kHz was chosen to minimize transformer size while keeping the fundamental EMI frequency below 150 kHz. The FREQUENCY pin (available only in Y, R or F package), when shorted to the CONTROL pin, lowers the switching frequency to 66 kHz (half frequency) which may be preferable in some cases such as noise sensitive video applications or a high efficiency standby mode. Otherwise, the FREQUENCY pin should be connected to the SOURCE pin for the default 132 kHz. To further reduce the EMI level, the switching frequency is jittered (frequency modulated) by approximately 4 kHz at 250 Hz (typical) rate as shown in Figure 9. Figure 46 shows the typical improvement of EMI measurements with frequency jitter. Pulse Width Modulator and Maximum Duty Cycle The pulse width modulator implements voltage mode control by driving the output MOSFET with a duty cycle inversely proportional to the current into the CONTROL pin that is in excess of the internal supply current of the chip (see Figure 7). The excess current is the feedback error signal that appears across RE (see Figure 2). This signal is filtered by an RC network with a typical corner frequency of 7 kHz to reduce the effect of switching noise in the chip supply current generated by the MOSFET gate driver. The filtered error signal is compared with the internal oscillator sawtooth waveform to generate the duty cycle waveform. As the control current increases, the duty cycle decreases. A clock signal from the oscillator sets a latch which turns on the output MOSFET. The pulse width modulator resets the latch, turning off the output MOSFET. Note that a minimum current must be driven into the CONTROL pin before the duty cycle begins to change. The maximum duty cycle, DCMAX, is set at a default maximum value of 78% (typical). However, by connecting the LINESENSE or MULTI-FUNCTION pin (depending on the package) to the rectified DC high voltage bus through a resistor with appropriate value, the maximum duty cycle can be made to decrease from 78% to 38% (typical) as shown in Figure 11 when input line voltage increases (see line feed forward with DCMAX reduction). Light Load Frequency Reduction The pulse width modulator duty cycle reduces as the load at the power supply output decreases. This reduction in duty cycle is proportional to the current flowing into the CONTROL pin. As the CONTROL pin current increases, the duty cycle decreases linearly towards a duty cycle of 10%. Below 10% duty cycle, to maintain high efficiency at light loads, the PI-2550-092499 TOP242-250 136 kHz Switching Frequency 128 kHz 4 ms VDRAIN Time Figure 9. Switching Frequency Jitter (Idealized VDRAIN Waveforms). frequency is also reduced linearly until a minimum frequency is reached at a duty cycle of 0% (refer to Figure 7). The minimum frequency is typically 30 kHz and 15 kHz for 132 kHz and 66 kHz operation, respectively. This feature allows a power supply to operate at lower frequency at light loads thus lowering the switching losses while maintaining good cross regulation performance and low output ripple. Error Amplifier The shunt regulator can also perform the function of an error amplifier in primary side feedback applications. The shunt regulator voltage is accurately derived from a temperaturecompensated bandgap reference. The gain of the error amplifier is set by the CONTROL pin dynamic impedance. The CONTROL pin clamps external circuit signals to the VC voltage level. The CONTROL pin current in excess of the supply current is separated by the shunt regulator and flows through RE as a voltage error signal. On-Chip Current Limit with External Programmability The cycle-by-cycle peak drain current limit circuit uses the output MOSFET ON-resistance as a sense resistor. A current limit comparator compares the output MOSFET on-state drain to source voltage, VDS(ON) with a threshold voltage. High drain current causes VDS(ON) to exceed the threshold voltage and turns the output MOSFET off until the start of the next clock cycle. The current limit comparator threshold voltage is temperature compensated to minimize the variation of the current limit due to temperature related changes in RDS(ON)of the output MOSFET. The default current limit of TOPSwitch-GX is preset internally. However, with a resistor connected between EXTERNAL CURRENT LIMIT (X) pin (Y, R or F package) or MULTIFUNCTION (M) pin (P or G package) and SOURCE pin, current limit can be programmed externally to a lower level between 30% and 100% of the default current limit. Please refer to the graphs in the typical performance characteristics section for the selection of the resistor value. By setting current limit low, a larger TOPSwitch-GX than necessary for the power O 11/05 7 TOP242-250 required can be used to take advantage of the lower RDS(ON) for higher efficiency/smaller heat sinking requirements. With a second resistor connected between the EXTERNAL CURRENT LIMIT (X) pin (Y, R or F package) or MULTIFUNCTION (M) pin (P or G package) and the rectified DC high voltage bus, the current limit is reduced with increasing line voltage, allowing a true power limiting operation against line variation to be implemented. When using an RCD clamp, this power limiting technique reduces maximum clamp voltage at high line. This allows for higher reflected voltage designs as well as reducing clamp dissipation. The leading edge blanking circuit inhibits the current limit comparator for a short time after the output MOSFET is turned on. The leading edge blanking time has been set so that, if a power supply is designed properly, current spikes caused by primary-side capacitances and secondary-side rectifier reverse recovery time should not cause premature termination of the switching pulse. The current limit is lower for a short period after the leading edge blanking time as shown in Figure 52. This is due to dynamic characteristics of the MOSFET. To avoid triggering the current limit in normal operation, the drain current waveform should stay within the envelope shown. Line Under-Voltage Detection (UV) At power up, UV keeps TOPSwitch-GX off until the input line voltage reaches the under-voltage threshold. At power down, UV prevents auto-restart attempts after the output goes out of regulation. This eliminates power down glitches caused by slow discharge of the large input storage capacitor present in applications such as standby supplies. A single resistor connected from the LINE-SENSE pin (Y, R or F package) or MULTI-FUNCTION pin (P or G package) to the rectified DC high voltage bus sets UV threshold during power up. Once the power supply is successfully turned on, the UV threshold is lowered to 40% of the initial UV threshold to allow extended input voltage operating range (UV low threshold). If the UV low threshold is reached during operation without the power supply losing regulation, the device will turn off and stay off until UV (high threshold) has been reached again. If the power supply loses regulation before reaching the UV low threshold, the device will enter auto-restart. At the end of each autorestart cycle (S7), the UV comparator is enabled. If the UV high threshold is not exceeded the MOSFET will be disabled during the next cycle (see Figure 8). The UV feature can be disabled independent of the OV feature as shown in Figures 19 and 23. Line Overvoltage Shutdown (OV) The same resistor used for UV also sets an overvoltage threshold which, once exceeded, will force TOPSwitch-GX output into off-state. The ratio of OV and UV thresholds is preset at 4.5 as can be seen in Figure 11. When the MOSFET is off, the rectified DC high voltage surge capability is increased to the voltage rating of the MOSFET (700 V), due to the absence of the reflected voltage and leakage spikes on the drain. A small amount of hysteresis is provided on the OV threshold to prevent noise triggering. The OV feature can be disabled independent of the UV feature as shown in Figures 18 and 32. Line Feed-Forward with DCMAX Reduction The same resistor used for UV and OV also implements line voltage feed-forward, which minimizes output line ripple and reduces power supply output sensitivity to line transients. This feed-forward operation is illustrated in Figure 7 by the different values of IL (Y, R or F package) or IM (P or G package). Note that for the same CONTROL pin current, higher line voltage results in smaller operating duty cycle. As an added Oscillator (SAW) DMAX Enable from X, L or M Pin (STOP) Time PI-2637-060600 Figure 10. Synchronization Timing Diagram. 8 O 11/05 TOP242-250 feature, the maximum duty cycle DCMAX is also reduced from 78% (typical) at a voltage slightly higher than the UV threshold to 30% (typical) at the OV threshold (see Figure 11). Limiting DCMAX at higher line voltages helps prevent transformer saturation due to large load transients in TOP248, TOP249 and TOP250 forward converter applications. DCMAX of 38% at high line was chosen to ensure that the power capability of the TOPSwitch-GX is not restricted by this feature under normal operation. Remote ON/OFF and Synchronization TOPSwitch-GX can be turned on or off by controlling the current into the LINE-SENSE pin or out from the EXTERNAL CURRENT LIMIT pin (Y, R or F package) and into or out from the MULTI-FUNCTION pin (P or G package) (see Figure 11). In addition, the LINE-SENSE pin has a 1 V threshold comparator connected at its input. This voltage threshold can also be used to perform remote ON/OFF control. This allows easy implementation of remote ON/OFF control of TOPSwitch-GX in several different ways. A transistor or an optocoupler output connected between the EXTERNAL CURRENT LIMIT or LINE-SENSE pins (Y, R or F package) or the MULTI-FUNCTION pin (P or G package) and the SOURCE pin implements this function with "active-on" (Figures 22, 29 and 36) while a transistor or an optocoupler output connected between the LINE-SENSE pin (Y, R or F package) or the MULTI-FUNCTION (P or G package) pin and the CONTROL pin implements the function with "active-off" (Figures 23 and 37). When a signal is received at the LINE-SENSE pin or the EXTERNAL CURRENT LIMIT pin (Y, R or F package) or the MULTI-FUNCTION pin (P or G package) to disable the output through any of the pin functions such as OV, UV and remote ON/OFF, TOPSwitch-GX always completes its current switching cycle, as illustrated in Figure 10, before the output is forced off. The internal oscillator is stopped slightly before the end of the current cycle and stays there as long as the disable signal exists. When the signal at the above pins changes state from disable to enable, the internal oscillator starts the next switching cycle. This approach allows the use of these pins to synchronize TOPSwitch-GX to any external signal with a frequency between its internal switching frequency and 20 kHz. As seen above, the remote ON/OFF feature allows the TOPSwitch-GX to be turned on and off instantly, on a cycleby-cycle basis, with very little delay. However, remote ON/OFF can also be used as a standby or power switch to turn off the TOPSwitch-GX and keep it in a very low power consumption state for indefinitely long periods. If the TOPSwitch-GX is held in remote off state for long enough time to allow the CONTROL pin to discharge to the internal supply under-voltage threshold of 4.8 V (approximately 32 ms for a 47 F CONTROL pin capacitance), the CONTROL pin goes into the hysteretic mode of regulation. In this mode, the CONTROL pin goes through alternate charge and discharge cycles between 4.8 V and 5.8 V (see CONTROL pin operation section above) and runs entirely off the high voltage DC input, but with very low power consumption (160 mW typical at 230 VAC with M or X pins open). When the TOPSwitch-GX is remotely turned on after entering this mode, it will initiate a normal start-up sequence with soft-start the next time the CONTROL pin reaches 5.8 V. In the worst case, the delay from remote on to start-up can be equal to the full discharge/charge cycle time of the CONTROL pin, which is approximately 125 ms for a 47 F CONTROL pin capacitor. This reduced consumption remote off mode can eliminate expensive and unreliable in-line mechanical switches. It also allows for microprocessor controlled turn-on and turn-off sequences that may be required in certain applications such as inkjet and laser printers. Soft-Start Two on-chip soft-start functions are activated at start-up with a duration of 10 ms (typical). Maximum duty cycle starts from 0% and linearly increases to the default maximum of 78% at the end of the 10 ms duration and the current limit starts from about 85% and linearly increases to 100% at the end of the 10 ms duration. In addition to start-up, soft-start is also activated at each restart attempt during auto-restart and when restarting after being in hysteretic regulation of CONTROL pin voltage (VC), due to remote OFF or thermal shutdown conditions. This effectively minimizes current and voltage stresses on the output MOSFET, the clamp circuit and the output rectifier during start-up. This feature also helps minimize output overshoot and prevents saturation of the transformer during start-up. Shutdown/Auto-Restart To minimize TOPSwitch-GX power dissipation under fault conditions, the shutdown/auto-restart circuit turns the power supply on and off at an auto-restart duty cycle of typically 4% if an out of regulation condition persists. Loss of regulation interrupts the external current into the CONTROL pin. VC regulation changes from shunt mode to the hysteretic autorestart mode as described in CONTROL pin operation section. When the fault condition is removed, the power supply output becomes regulated, VC regulation returns to shunt mode, and normal operation of the power supply resumes. Hysteretic Over-Temperature Protection Temperature protection is provided by a precision analog circuit that turns the output MOSFET off when the junction temperature exceeds the thermal shutdown temperature (140 C typical). When the junction temperature cools to below the hysteretic temperature, normal operation resumes providing automatic recovery. A large hysteresis of 70 C (typical) is provided to prevent overheating of the PC board due to a continuous fault condition. VC is regulated in hysteretic mode and a 4.8 V to 5.8 V (typical) sawtooth waveform is present on the CONTROL pin while in thermal shutdown. O 11/05 9 TOP242-250 Bandgap Reference All critical TOPSwitch-GX internal voltages are derived from a temperature-compensated bandgap reference. This reference is also used to generate a temperature-compensated current reference, which is trimmed to accurately set the switching frequency, MOSFET gate drive current, current limit, and the line OV/UV thresholds. TOPSwitch-GX has improved circuitry to maintain all of the above critical parameters within very tight absolute and temperature tolerances. may be used to lower the switching frequency from 132 kHz in normal operation to 66 kHz in standby mode for very low standby power consumption. LINE-SENSE (L) Pin Operation (Y, R and F Packages) When current is fed into the LINE-SENSE pin, it works as a voltage source of approximately 2.6 V up to a maximum current of +400 A (typical). At +400 A, this pin turns into a constant current sink. Refer to Figure 12a. In addition, a comparator with a threshold of 1 V is connected at the pin and is used to detect when the pin is shorted to the SOURCE pin. High-Voltage Bias Current Source This current source biases TOPSwitch-GX from the DRAIN pin and charges the CONTROL pin external capacitance during start-up or hysteretic operation. Hysteretic operation occurs during auto-restart, remote OFF and over-temperature shutdown. In this mode of operation, the current source is switched on and off with an effective duty cycle of approximately 35%. This duty cycle is determined by the ratio of CONTROL pin charge (IC) and discharge currents (ICD1 and ICD2). This current source is turned off during normal operation when the output MOSFET is switching. The effect of the current source switching will be seen on the DRAIN voltage waveform as small disturbances and is normal. There are a total of four functions available through the use of the LINE-SENSE pin: OV, UV, line feed-forward with DCMAX reduction, and remote ON/OFF. Connecting the LINE-SENSE pin to the SOURCE pin disables all four functions. The LINESENSE pin is typically used for line sensing by connecting a resistor from this pin to the rectified DC high voltage bus to implement OV, UV and DCMAX reduction with line voltage. In this mode, the value of the resistor determines the line OV/UV thresholds, and the DCMAX is reduced linearly with rectified DC high voltage starting from just above the UV threshold. The pin can also be used as a remote ON/OFF and a synchronization input. Refer to Table 2 for possible combinations of the functions with example circuits shown in Figure 16 through Figure 40. A description of specific functions in terms of the LINE-SENSE pin I/V characteristic is shown in Figure 11 (right hand side). The horizontal axis represents LINE-SENSE pin current with positive polarity indicating currents flowing into the pin. The meaning of the vertical axes varies with functions. For those that control the ON/OFF states of the output such as UV, OV and remote ON/OFF, the vertical axis represents the enable/ disable states of the output. UV triggers at IUV (+50 A typical with 30 A hysteresis) and OV triggers at IOV (+225 A typical with 8 A hysteresis). Between the UV and OV thresholds, the output is enabled. For line feed-forward with Using Feature Pins FREQUENCY (F) Pin Operation The FREQUENCY pin is a digital input pin available in the Y, R or F package only. Shorting the FREQUENCY pin to SOURCE pin selects the nominal switching frequency of 132 kHz (Figure 13), which is suited for most applications. For other cases that may benefit from lower switching frequency such as noise sensitive video applications, a 66 kHz switching frequency (half frequency) can be selected by shorting the FREQUENCY pin to the CONTROL pin (Figure 14). In addition, an example circuit shown in Figure 15 LINE-SENSE AND EXTERNAL CURRENT LIMIT PIN TABLE* 17 18 Under-Voltage Overvoltage Line Feed-Forward (DCMAX) Figure Number Three Terminal Operation 16 19 20 Remote ON/OFF 22 23 24 25 26 27 28 *This table is only a partial list of many LINE-SENSE and EXTERNAL CURRENT LIMIT pin configurations that are possible. Table 2. Typical LINE-SENSE and EXTERNAL CURRENT LIMIT Pin Configurations. 10 O 11/05 29 Overload Power Limiting External Current Limit 21 TOP242-250 for P and G packages. The comparator with a 1 V threshold at the LINE-SENSE pin is removed in this case as shown in Figure 2b. All of the other functions are kept intact. However, since some of the functions require opposite polarity of input current (MULTI-FUNCTION pin), they are mutually exclusive. For example, line sensing features cannot be used simultaneously with external current limit setting. When current is fed into the MULTI-FUNCTION pin, it works as a voltage source of approximately 2.6 V up to a maximum current of +400 A (typical). At +400 A, this pin turns into a constant current sink. When current is drawn out of the MULTI-FUNCTION pin, it works as a voltage source of approximately 1.3 V up to a maximum current of -240 A (typical). At -240 A, it turns into a constant current source. Refer to Figure 12b. DCMAX reduction, the vertical axis represents the magnitude of the DCMAX. Line feed-forward with DCMAX reduction lowers maximum duty cycle from 78% at IL(DC) (+60 A typical) to 38% at IOV (+225 A). EXTERNAL CURRENT LIMIT (X) Pin Operation (Y, R and F Packages) When current is drawn out of the EXTERNAL CURRENT LIMIT pin, it works as a voltage source of approximately 1.3 V up to a maximum current of -240 A (typical). At -240 A, it turns into a constant current source (refer to Figure 12a). There are two functions available through the use of the EXTERNAL CURRENT LIMIT pin: external current limit and remote ON/OFF. Connecting the EXTERNAL CURRENT LIMIT pin to the SOURCE pin disables the two functions. In high efficiency applications, this pin can be used to reduce the current limit externally to a value close to the operating peak current by connecting the pin to the SOURCE pin through a resistor. The pin can also be used for remote ON/OFF. Table 2 shows several possible combinations using this pin. See Figure 11 for a description of the functions where the horizontal axis (left hand side) represents the EXTERNAL CURRENT LIMIT pin current. The meaning of the vertical axes varies with function. For those that control the ON/OFF states of the output such as remote ON/OFF, the vertical axis represents the enable/disable states of the output. For external current limit, the vertical axis represents the magnitude of the ILIMIT. Please see graphs in the Typical Performance Characteristics section for the current limit programming range and the selection of appropriate resistor value. There are a total of five functions available through the use of the MULTI-FUNCTION pin: OV, UV, line feed-forward with DCMAX reduction, external current limit and remote ON/OFF. A short circuit between the MULTI-FUNCTION pin and SOURCE pin disables all five functions and forces TOPSwitch-GX to operate in a simple three terminal mode like TOPSwitch-II. The MULTI-FUNCTION pin is typically used for line sensing by connecting a resistor from this pin to the rectified DC high voltage bus to implement OV, UV and DCMAX reduction with line voltage. In this mode, the value of the resistor determines the line OV/UV thresholds, and the DCMAX is reduced linearly with increasing rectified DC high voltage starting from just above the UV threshold. External current limit programming is implemented by connecting the MULTI-FUNCTION pin to the SOURCE pin through a resistor. However, this function is not necessary in most applications since the internal current limit of the P and G package devices has been reduced, compared to the Y, R and F package devices, to match the thermal dissipation capability of the P and G packages. It is therefore recommended that the MULTIFUNCTION pin is used for line sensing as described above and not for external current limit reduction. The same pin can also MULTI-FUNCTION (M) Pin Operation (P and G Packages) The LINE-SENSE and EXTERNAL CURRENT LIMIT pin functions are combined to a single MULTI-FUNCTION pin MULTI-FUNCTION PIN TABLE* 31 32 Under-Voltage Overvoltage Line Feed-Forward (DCMAX) Figure Number Three Terminal Operation 30 33 34 35 36 37 38 39 40 Overload Power Limiting External Current Limit Remote ON/OFF *This table is only a partial list of many MULTI-FUNCTION pin configurations that are possible. Table 3. Typcial MULTI-FUNCTION Pin Configurations. O 11/05 11 TOP242-250 M Pin X Pin L Pin IREM(N) IUV IOV (Enabled) Output MOSFET Switching (Disabled) Disabled when supply output goes out of regulation I ILIMIT (Default) Current Limit I DCMAX (78.5%) Maximum Duty Cycle I -22 A -27 A VBG + VTP VBG Pin Voltage -250 -200 -150 -100 -50 0 50 100 150 200 250 300 350 400 I X and L Pins (Y, R or F Package) and M Pin (P or G Package) Current (A) Note: This figure provides idealized functional characteristics with typical performance values. Please refer to the parametric table and typical performance characteristics sections of the data sheet for measured data. PI-2636-010802 Figure 11. MULTI-FUNCTION (P or G package), LINSE-SENSE, and EXTERNAL CURRENT LIMIT (Y, R or F package) Pin Characteristics. be used as a remote ON/OFF and a synchronization input in both modes. Please refer to Table 3 for possible combinations of the functions with example circuits shown in Figure 30 through Figure 40. A description of specific functions in terms of the MULTI-FUNCTION pin I/V characteristic is shown in Figure 11. The horizontal axis represents MULTI-FUNCTION pin current with positive polarity indicating currents flowing into the pin. The meaning of the vertical axes varies with functions. For those that control the ON/OFF states of the output such as UV, OV and remote ON/OFF, the vertical axis represents the enable/disable states of the output. UV triggers at IUV 12 O 11/05 (+50 A typical) and OV triggers at IOV (+225 A typical with 30 A hysteresis). Between the UV and OV thresholds, the output is enabled. For external current limit and line feedforward with DCMAX reduction, the vertical axis represents the magnitude of the ILIMIT and DCMAX. Line feed-forward with DCMAX reduction lowers maximum duty cycle from 78% at IM(DC) (+60 A typical) to 38% at IOV (+225 A). External current limit is available only with negative MULTI-FUNCTION pin current. Please see graphs in the Typical Performance Characteristics section for the current limit programming range and the selection of appropriate resistor value. TOP242-250 CONTROL (C) Y, R and F Package TOPSwitch-GX 240 A (Negative Current Sense - ON/OFF, Current Limit Adjustment) VBG + VT EXTERNAL CURRENT LIMIT (X) (Voltage Sense) LINE-SENSE (L) VBG 1V (Positive Current Sense - Under-Voltage, Overvoltage, ON/OFF Maximum Duty Cycle Reduction) 400 A PI-2634-022604 Figure 12a. LINE-SENSE (L), and EXTERNAL CURRENT LIMIT (X) Pin Input Simplified Schematic. P and G Package CONTROL (C) TOPSwitch-GX 240 A (Negative Current Sense - ON/OFF, Current Limit Adjustment) VBG + VT MULTI-FUNCTION (M) VBG (Positive Current Sense - Under-Voltage, Overvoltage, Maximum Duty Cycle Reduction) 400 A PI-2548-022604 Figure 12b. MULTI-FUNCTION (M) Pin Input Simplified Schematic. O 11/05 13 TOP242-250 Typical Uses of FREQUENCY (F) PIN + + DC Input Voltage DC Input Voltage D CONTROL S C D CONTROL S F C F - - PI-2655-071700 PI-2654-071700 Figure 13. Full Frequency Operation (132 kHz). Figure 14. Half Frequency Operation (66 kHz). + DC Input Voltage QS can be an optocoupler output. D CONTROL S - F RHF 20 k C QS 47 k STANDBY 1 nF PI-2656-040501 Figure 15. Half Frequency Standby Mode (For High Standby Efficiency). 14 O 11/05 TOP242-250 Typical Uses of LINE-SENSE (L) and EXTERNAL CURRENT LIMIT (X) Pins + + CL XS F DC Input Voltage DC Input Voltage CONTROL S - X RLS D L D VUV = IUV x RLS VOV = IOV x RLS C S L D D CONTROL C F 2 M For RLS = 2 M VUV = 100 VDC VOV = 450 VDC DCMAX@100 VDC = 78% DCMAX@375 VDC = 38% C S PI-2617-050100 Figure 16. Three Terminal Operation (LINE-SENSE and EXTERNAL CURRENT LIMIT Features Disabled. FREQUENCY Pin Tied to SOURCE or CONTROL Pin). PI-2618-081403 Figure 17. Line-Sensing for Under-Voltage, Overvoltage and Line Feed-Forward. + + VUV = RLS x IUV 2 M RLS DC Input Voltage D CONTROL For Values Shown VOV = 450 VDC RLS DC Input Voltage 30 k CONTROL C C S - S 1N4148 L D M 6.2 V - For Value Shown VUV = 100 VDC 22 k VOV = IOV x RLS 2 M PI-2510-040501 Figure 18. Line-Sensing for Under-Voltage Only (Overvoltage Disabled). + For RIL = 12 k ILIMIT = 69% PI-2620-040501 Figure 19. Linse-Sensing for Overvoltage Only (Under-Voltage Disabled). Maximum Duty Cycle Reduced at Low Line and Further Reduction with Increasing Line Voltage. + RLS For RIL = 25 k ILIMIT = 43% DC Input Voltage D CONTROL S - C See Figure 54b for other resistor values (RIL) DC Input Voltage ILIMIT = 100% @ 100 VDC ILIMIT = 63% @ 300 VDC 2.5 M D CONTROL S X RIL - C X RIL 6 k PI-2624-040501 PI-2623-092303 Figure 20. Externally Set Current Limit. Figure 21. Current Limit Reduction with Line Voltage. O 11/05 15 TOP242-250 Typical Uses of LINE-SENSE (L) and EXTERNAL CURRENT LIMIT (X) Pins (cont.) + QR can be an optocoupler output or can be replaced by a manual switch. QR can be an optocoupler output or can be replaced by a manual switch. + QR ON/OFF DC Input Voltage CONTROL S C 45 k L D CONTROL X C ON/OFF QR - RMC 47 k DC Input Voltage D 47 K S PI-2625-040501 Figure 22. Active-on (Fail Safe) Remove ON/OFF. + Figure 23. Active-off Remote ON/OFF. Maximum Duty Cycle Reduced. QR can be an optocoupler output or can be replaced by a manual switch. DC Input Voltage For RIL = 12 k ILIMIT = 69% D CONTROL S C PI-2621-040501 For RIL = 25 k ILIMIT = 43% + ON/OFF RMC 47 k 45 k DC Input Voltage X L D CONTROL S RIL - QR ON/OFF 47 k QR can be an optocoupler output or can be replaced by a manual switch. QR C X RIL - PI-2627-040501 PI-2626-040501 Figure 24. Active-on Remote ON/OFF with Externally Set Current Limit. + RLS 2 M QR can be an optocoupler output or can be replaced by a manual switch. QR ON/OFF DC Input Voltage VUV = IUV x RLS VOV = IOV x RLS + VUV = 100 VDC VOV = 450 VDC L CONTROL 2 M RLS For RLS = 2 M 47 k D Figure 25. Active-off Remote ON/OFF with Externally Set Current Limit. DC Input Voltage C L D CONTROL S - PI-2622-040501 Figure 26. Active-off Remote ON/OFF with LINE-SENSE. 16 O 11/05 QR can be an optocoupler output or can be replaced by a manual switch. C For RIL = 12 k ILIMIT = 69% X RIL S DCMAX@100 VDC = 78% DCMAX@375 VDC = 38% QR 47 k ON/OFF PI-2628-040501 Figure 27. Active-on Remote ON/OFF with LINE-SENSE and EXTERNAL CURRENT LIMIT. TOP242-250 PI-2629-092203 Typical Uses of LINE-SENSE (L) and EXTERNAL CURRENT LIMIT (X) Pins (cont.) VUV = IUV x RLS VOV = IOV x RLS + DC Input Voltage VUV = 100 VDC VOV = 450 VDC CONTROL C For RIL = 12 k ILIMIT = 69% X QR can be an optocoupler output or can be replaced by a manual switch. 300 k L D CONTROL C S See Figure 54b for other resistor values (RIL) to select different ILIMIT values RIL 12 k - DC Input Voltage DCMAX@100 VDC = 78% DCMAX@375 VDC = 38% L D S For RLS = 2 M 2 M RLS + Figure 28. Line-Sensing and Externally Set Current Limit. QR - 47 k ON/OFF PI-2640-040501 Figure 29. Active-on Remote ON/OFF. Typical Uses of MULTI-FUNCTION (M) Pin + + C DC Input Voltage D D M CONTROL C S S S VUV = IUV x RLS VOV = IOV x RLS M RLS S DC Input Voltage S D - DCMAX@100 VDC = 78% DCMAX@375 VDC = 38% M CONTROL C S - D For RLS = 2 M VUV = 100 VDC VOV = 450 VDC 2 M C S PI-2508-081199 Figure 30. Three Terminal Operation (MULIT-FUNCTION Features Disabled). Figure 31. Line-Sensing for Undervoltage, Over-Voltage and Line Feed-Forward. + + VUV = RLS x IUV 2 M RLS DC Input Voltage D 6.2 V VOV = IOV x RLS 2 M For Value Shown VUV = 100 VDC For Values Shown VOV = 450 VDC RLS DC Input Voltage 22 k M CONTROL - PI-2509-040501 30 k D 1N4148 M CONTROL C S PI-2510-040501 Figure 32. Line-Sensing for Under-Voltage Only (Overvoltage Disabled). C S PI-2516-040501 Figure 33. Line-Sensing for Overvoltage Only (Under-Voltage Disabled). Maximum Duty Cycle Reduced at Low Line and Further Reduction with Increasing Line Voltage. O 11/05 17 TOP242-250 Typical Uses of MULTI-FUNCTION (M) Pin (cont.) + + For RIL = 12 k ILIMIT = 69% For RIL = 25 k ILIMIT = 43% DC Input Voltage D See Figures 54b, 55b and 56b for other resistor values (RIL) to select different ILIMIT values. M CONTROL RIL RLS DC Input Voltage S - D RIL C ILIMIT = 100% @ 100 VDC ILIMIT = 63% @ 300 VDC 2.5 M M CONTROL 6 k S PI-2517-022604 Figure 34. Externally Set Current Limit (Not Normally Required-See M Pin Operation Description). + QR can be an optocoupler output or can be replaced by a manual switch. C PI-2518-040501 Figure 35. Current Limit Reduction with Line Voltage (Not Normally Required-See M Pin Operation Description). + QR can be an optocoupler output or can be replaced by a manual switch. QR DC Input Voltage D M CONTROL QR DC ON/OFF Input 47 k Voltage D RMC M 45 k CONTROL C C ON/OFF 47 k - S PI-2519-040501 Figure 36. Active-on (Fail Safe) Remote ON/OFF. 18 O 11/05 S PI-2522-040501 Figure 37. Active-off Remote ON/OFF. Maximum Duty Cycle Reduced. TOP242-250 Typical Uses of MULTI-FUNCTION (M) Pin (cont.) + + QR can be an optocoupler output or can be replaced by a manual switch. QR For RIL = 12 k ILIMIT = 69% DC Input Voltage DC Input Voltage For RIL = 25 k RIL D ILIMIT = 43% M CONTROL QR QR can be an optocoupler output or can be replaced by a manual switch. C ON/OFF 47 k M D RIL CONTROL 12 k RMC 24 k RMC = 2RIL C ON/OFF 47 k - S S PI-2520-040501 PI-2521-040501 Figure 38. Active-on Remote ON/OFF with Externally Set Current Limit (See M Pin Operation Description). Figure 39. Active-off Remote ON/OFF with Externally Set Current Limit (See M Pin Operation Description). QR can be an optocoupler output or can be replaced by a manual switch. + RLS DC ON/OFF Input 47 k Voltage D 2 M QR CONTROL - For RLS = 2 M M C VUV = 100 VDC VOV = 450 VDC S PI-2523-040501 Figure 40. Active-off Remote ON/OFF with LINE-SENSE. O 11/05 19 TOP242-250 Application Examples TOPSwitch-GX (guaranteed minimum value of 75% vs. 64% for TOPSwitch-II) allows the use of a smaller input capacitor (C1). The extended maximum duty cycle and the higher reflected voltage possible with the RCD clamp also permit the use of a higher primary to secondary turns ratio for T1, which reduces the peak reverse voltage experienced by the secondary rectifier D8. As a result a 60 V Schottky rectifier can be used for up to 15 V outputs, which greatly improves power supply efficiency. The frequency reduction feature of the TOPSwitch-GX eliminates the need for any dummy loading for regulation at no load and reduces the no-load/standby consumption of the power supply. Frequency jitter provides improved margin for conducted EMI, meeting the CISPR 22 (FCC B) specification. A High Efficiency, 30 W, Universal Input Power Supply The circuit shown in Figure 41 takes advantage of several of the TOPSwitch-GX features to reduce system cost and power supply size and to improve efficiency. This design delivers 30 W at 12 V, from an 85 VAC to 265 VAC input, at an ambient of 50 C, in an open frame configuration. A nominal efficiency of 80% at full load is achieved using TOP244Y. The current limit is externally set by resistors R1 and R2 to a value just above the low line operating peak DRAIN current of approximately 70% of the default current limit. This allows use of a smaller transformer core size and/or higher transformer primary inductance for a given output power, reducing TOPSwitch-GX power dissipation, while at the same time avoiding transformer core saturation during startup and output transient conditions. The resistors R1 & R2 provide a signal that reduces the current limit with increasing line voltage, which in turn limits the maximum overload power at high input line voltage. This function in combination with the built-in soft-start feature of TOPSwitch-GX, allows the use of a low cost RCD clamp (R3, C3 and D1) with a higher reflected voltage, by safely limiting the TOPSwitch-GX drain voltage, with adequate margin under worst case conditions. Resistor R4 provides line sensing, setting UV at 100 VDC and OV at 450 VDC. The extended maximum duty cycle feature of Output regulation is achieved by using a simple Zener sense circuit for low cost. The output voltage is determined by the Zener diode (VR2) voltage and the voltage drops across the optocoupler (U2) LED and resistor R6. Resistor R8 provides bias current to Zener VR2 for typical regulation of 5% at the 12 V output level, over line and load and component variations. A High Efficiency, Enclosed, 70 W, Universal Adapter Supply The circuit shown in Figure 42 takes advantage of several of the TOPSwitch-GX features to reduce cost, power supply size and PERFORMANCE SUMMARY Output Power: Regulation: Efficiency: Ripple: CY1 2.2 nF 30 W 4% 79% 50 mV pk-pk C14 R15 1 nF 150 L3 3.3 H R3 68 k 2W C3 4.7 nF 1 kV BR1 600 V 2A C1 68 F 400 V D2 1N4148 D S R2 9.09 k N R6 150 C6 0.1 F T1 R1 4.7 M 1/2 W F1 3.15 A L C12 220 F 35 V C11 560 F 35 V RTN R4 2 M 1/2 W CX1 100 nF 250 VAC C10 560 F 35 V D1 UF4005 L1 20 mH J1 D8 MBR1060 12 V @ 2.5 A TOPSwitch-GX U1 TOP244Y CONTROL C L X R5 6.8 F R8 150 U2 LTV817A VR2 1N5240C 10 V, 2% C5 47 F 10 V PI-2657-081204 Figure 41. 30 W Power Supply using External Current Limit Programming and Line Sensing for UV and OV. 20 O 11/05 TOP242-250 increase efficiency. This design delivers 70 W at 19 V, from an 85 VAC to 265 VAC input, at an ambient of 40 C, in a small sealed adapter case (4" x 2.15" x 1"). Full load efficiency is 85% at 85 VAC rising to 90% at 230 VAC input. reduce Zener clamp dissipation. With a switching frequency of 132 kHz, a PQ26/20 core can be used to provide 70 W. To maximize efficiency, by reducing winding losses, two output windings are used each with their own dual 100 V Schottky rectifier (D2 and D3). The frequency reduction feature of the TOPSwitch-GX eliminates any dummy loading to maintain regulation at no load and reduces the no-load consumption of the power supply to only 520 mW at 230 VAC input. Frequency jittering provides conducted EMI meeting the CISPR 22 (FCC B) / EN55022B specification, using simple filter components (C7, L2, L3 and C6), even with the output earth grounded. Due to the thermal environment of a sealed adapter, a TOP249Y is used to minimize device dissipation. Resistors R9 and R10 externally program the current limit level to just above the operating peak DRAIN current at full load and low line. This allows the use of a smaller transformer core size without saturation during startup or output load transients. Resistors R9 and R10 also reduce the current limit with increasing line voltage, limiting the maximum overload power at high input line voltage, removing the need for any protection circuitry on the secondary. Resistor R11 implements an under-voltage and overvoltage sense as well as providing line feed-forward for reduced output line frequency ripple. With resistor R11 set at 2 M, the power supply does not start operating until the DC rail voltage reaches 100 VDC. On removal of the AC input, the UV sense prevents the output glitching as C1 discharges, turning off the TOPSwitch-GX when the output regulation is lost or when the input voltage falls to below 40 V, whichever occurs first. This same value of R11 sets the OV threshold to 450 V. If exceeded, for example during a line surge, TOPSwitch-GX stops switching for the duration of the surge, extending the high voltage withstand to 700 V without device damage. Capacitor C11 has been added in parallel with VR1 to To regulate the output, an optocoupler (U2) is used with a secondary reference sensing the output voltage via a resistor divider (U3, R4, R5, R6). Diode D4 and C15 filter and smooth the output of the bias winding. Capacitor C15 (1 F) prevents the bias voltage from falling during zero to full load transients. Resistor R8 provides filtering of leakage inductance spikes, keeping the bias voltage constant even at high output loads. Resistor R7, C9 and C10 together with C5 and R3 provide loop compensation. Due to the large primary currents, all the small signal control components are connected to a separate source node that is Kelvin connected to the SOURCE pin of the TOPSwitch-GX. For improved common-mode surge immunity, the bias winding common returns directly to the DC bulk capacitor (C1). C7 2.2 nF C13 C12 C11 0.33 F 0.022 F 0.01 F 400 V 400 V 400 V Y1 Safety D3 MBR20100 VR1 P6KE200 BR1 RS805 8A 600 V L2 820 H 2A 85-265 VAC C6 0.1 F X2 J1 L N R11 2 M 1/2 W C1 150 F 400 V t L3 75 H 2A D4 1N4148 L TOPSwitch-GX CONTROL R9 13 M S R10 20.5 k X C2 820 F 25 V C TOP249Y U1 F C8 0.1 F 50 V R3 6.8 C5 47 F 16 V L1 200 H R1 270 U2 PC817A R8 4.7 T1 PERFORMANCE SUMMARY Output Power: 70 W Regulation: 4% Efficiency: 84% Ripple: 120 mV pk-pk No Load Consumption: < 0.52 W @ 230 VAC C3 820 F 25 V D1 UF4006 D RT1 10 1.7 A F1 3.15 A D2 MBR20100 R2 1 k C15 1 F 50 V C14 0.1 F 50 V 19 V @ 3.6 A C4 820 F 25 V R4 31.6 k 1% RTN R5 562 C9 1% 4.7 nF 50 V U3 TL431 R7 56 k C10 0.1 F 50 V R6 4.75 k 1% All resistors 1/8 W 5% unless otherwise stated. PI-2691-042203 Figure 42. 70 W Power Supply using Current Limit Reduction with Line and Line Sensing for UV and OV. O 11/05 21 TOP242-250 A High Efficiency, 250 W, 250-380 VDC Input Power Supply The circuit shown in Figure 43 delivers 250 W (48 V @ 5.2 A) at 84% efficiency using a TOP249 from a 250 VDC to 380 VDC input. DC input is shown, as typically at this power level a p.f.c. boost stage would preceed this supply, providing the DC input (C1 is included to provide local decoupling). Flyback topology is still usable at this power level due to the high output voltage, keeping the secondary peak currents low enough so that the output diode and capacitors are reasonably sized. However, VR1 is essential to limit the peak drain voltage during start-up and/or overload conditions to below the 700 V rating of the TOPSwitch-GX MOSFET. The secondary is rectifed and smoothed by D2 and C9, C10 and C11. Three capacitors are used to meet the secondary ripple current requirement. Inductor L2 and C12 provide switching noise filtering. A simple Zener sensing chain regulates the output voltage. The sum of the voltage drop of VR2, VR3 and VR4 plus the LED drop of U2 gives the desired output voltage. Resistor R6 limits LED current and sets overall control loop DC gain. Diode D4 and C14 provide secondary soft-finish, feeding current into the CONTROL pin prior to output regulation and thus ensuring that the output voltage reaches regulation at startup under low line, full load conditions. Resistor R9 provides a discharge path for C14. Capacitor C13 and R8 provide control loop compensation and are required due to the gain associated with such a high output voltage. In this example, the TOP249 is at the upper limit of its power capability and the current limit is set to the internal maximum by connecting the X pin to SOURCE. However, line sensing is implemented by connecting a 2 M resistor from the L pin to the DC rail. If the DC input rail rises above 450 VDC, then TOPSwitch-GX will stop switching until the voltage returns to normal, preventing device damage. Due to the high primary current, a low leakage inductance transformer is essential. Therefore, a sandwich winding with a copper foil secondary was used. Even with this technique, the leakage inductance energy is beyond the power capability of a simple Zener clamp. Therefore, R2, R3 and C6 are added in parallel to VR1. These have been sized such that during normal operation, very little power is dissipated by VR1, the leakage energy instead being dissipated by R2 and R3. Sufficient heat sinking is required to keep the TOPSwitch-GX device below 110 C when operating under full load, low line and maximum ambient temperature. Airflow may also be required if a large heatsink area is not acceptable. C7 2.2 nF Y1 +250-380 VDC VR1 P6KE200 R2 68 k 2W R3 68 k 2W D2 MUR1640CT C6 4.7 nF 1 kV C10 560 F 63 V C11 560 F 63 V L2 3 H 8A C9 560 F 63 V D1 BYV26C D2 1N4148 R1 2 M 1/2 W T1 C1 22 F 400 V PERFORMANCE SUMMARY Output Power: Line Regulation: Load Regulation: Efficiency: Ripple: No Load Consumption: 250 W 1% 5% 85% < 100 mV pk-pk 1.4 W (300 VDC) 0V CONTROL S X C F C3 0.1 F 50 V R9 10 k R6 100 C13 150 nF 63 V TOP249Y U1 L RTN R4 6.8 C3 47 F 10 V D4 1N4148 VR2 22 V BZX79B22 VR3 12 V BZX79B12 R8 56 O 11/05 C14 22 F 63 V VR4 12 V BZX79B12 All resistor 1/8 W 5% unless otherwise stated. Figure 43. 250 W, 48 V Power Supply using TOP249. 22 D C12 68 F 63 V U2 LTV817A C4 1 F 50 V TOPSwitch-GX 48 V@ 5.2 A PI-2692-081204 TOP242-250 Multiple Output, 60 W, 185-265 VAC Input Power Supply Figure 44 shows a multiple output supply typical for high end set-top boxes or cable decoders containing high capacity hard disks for recording. The supply delivers an output power of 45 W continuous/60 W peak (thermally limited) from an input voltage of 185 VAC to 265 VAC. Efficiency at 45 W, 185 VAC is 75%. The 3.3 V and 5 V outputs are regulated to 5% without the need for secondary linear regulators. DC stacking (the secondary winding reference for the other output voltages is connected to the cathode of D10 rather than the anode) is used to minimize the voltage error for the higher voltage outputs. Due to the high ambient operating temperature requirement typical of a set-top box (60 C), the TOP246Y is used to reduce conduction losses and minimize heatsink size. Resistor R2 sets the device current limit to 80% of typical to limit overload power. The line sense resistor (R1) protects the TOPSwitch-GX from line surges and transients by sensing when the DC rail voltage rises to above 450 V. In this condition the TOPSwitch-GX stops switching, extending the input voltage withstand to 496 VAC, which is ideal for countries with poor power quality. A thermistor (RT1) is used to prevent premature failure of the fuse by limiting the inrush current (due PERFORMANCE SUMMARY Output Power: 45 W Cont./60 W Peak Regulation: 3.3 V: 5% 5 V: 5% 12 V: 7% 18 V: 7% 30 V: 8% Efficiency: 75% No Load Consumption: 0.6 W VR1 P6KE170 R6 10 D9 UF5402 L t 185-265 VAC J1 D RT1 10 1.7 A C9 330 F 25 V C11 390 F 35 V C13 1000 F 25 V C16 1000 F 25 V D11 MBR1045 C17 1000 F 25 V 12 V @ 0.6 A C12 100 F 25 V L4 3.3 H 5A L5 3.3 H 5A 18 V @ 0.5 A C10 100 F 25 V L3 3.3 H 3A C14 1000 F 25 V D10 BYV32-200 C8 10 F 50 V L2 3.3 H 3A 5V@ 3.2 A C15 220 F 16 V 3.3 V @ 3A C18 220 F 16 V RTN D6 1N4937 C1 0.1 F X1 F1 3.15 A 30 V @ 0.03 A C7 47 F 50 V R5 68 k 2W R1 2 M 1/2 W RV1 275 V 14 mm The secondaries are rectified and smoothed by D7 to D11, C7, C9, C11, C13, C14, C16 and C17. Diode D11 for the 3.3 V output is a Schottky diode to maximize efficiency. Diode D10 for the 5 V output is a PN type to center the 5 V output at 5 V. The 3.3 V and 5 V output require two capacitors in parallel to meet the ripple current requirement. Switching noise filtering is provided by L2 to L5 and C8, C10, C12, C15 and C18. Resistor R6 prevents peak charging of the lightly loaded 30 V output. The outputs are regulated using a secondary reference (U3). Both the 3.3 V and 5 V outputs are sensed via R11 and R10. Resistor R8 provides bias for U3 and R7 sets the overall DC gain. Resistor R9, C19, R3 and C5 provide loop compensation. A soft-finish capacitor (C20) eliminates output overshoot. C6 2.2 nF Y1 C2 68 F 400 V L1 20 mH 0.8A Leakage inductance clamping is provided by VR1, R5 and C5, keeping the DRAIN voltage below 700 V under all conditions. Resistor R5 and capacitor C5 are selected such that VR1 dissipates very little power except during overload conditions. The frequency jittering feature of TOPSwitch-GX allows the circuit shown to meet CISPR22B with simple EMI filtering (C1, L1 and C6) and the output grounded. D7 UF4003 D8 UF5402 C5 1 nF 400 V D1-D4 1N4007 V to the relatively large size of C2). An optional MOV (RV1) extends the differential surge protection to 6 kV from 4 kV. S D6 1N4148 C3 1 F 50 V T1 U2 LTV817 TOPSwitch-GX L TOP246Y U1 CONTROL C C3 R3 0.1 F 6.8 X F 50 V R2 9.08 k C5 47 F 10 V N R10 15.0 k R7 150 R8 1 k R9 3.3 k C20 22 F 10 V U3 TL431 R11 9.53 k C19 0.1 F R12 10 k PI-2693-081704 Figure 44. 60 W Multiple Output Power Supply using TOP246. O 11/05 23 TOP242-250 Processor Controlled Supply Turn On/Off A low cost momentary contact switch can be used to turn the TOPSwitch-GX power on and off under microprocessor control, which may be required in some applications such as printers. The low power remote OFF feature allows an elegant implementation of this function with very few external components, as shown in Figure 45. Whenever the push button momentary contact switch P1 is closed by the user, the optocoupler U3 is activated to inform the microprocessor of this action. Initially, when the power supply is off (M pin is floating), closing of P1 turns the power supply on by shorting the M pin of the TOPSwitch-GX to SOURCE through a diode (remote ON). When the secondary output voltage VCC is established, the microprocessor comes alive and recognizes that the switch P1 is closed through the switch status input that is driven by the optocoupler U3 output. The microprocessor then sends a power supply control signal to hold the power supply in the on-state through the optocoupler U4. If the user presses the switch P1 again to command a turn off, the microprocessor detects this through the optocoupler U3 and initiates a shutdown procedure that is product specific. For example, in the case of the inkjet printer, the shutdown procedure may include safely parking the print heads in the storage position. In the case of products with a disk drive, the shutdown procedure may include saving data or settings to the disk. After the shutdown procedure is complete, when it is safe to turn off the power supply, the microprocessor releases the M pin by turning the optocoupler U4 off. If the manual switch and the optocouplers U3 and U4 are not located close to the M pin, a capacitor CM may be needed to prevent noise coupling to the pin when it is open. The power supply could also be turned on remotely through a local area network or a parallel or serial port by driving the optocoupler U4 input LED with a logic signal. Sometimes it is easier to send a train of logic pulses through a cable (due to AC coupling of cable, for example) instead of a DC logic level as a wake up signal. In this case, a simple RC filter can be used to generate a DC level to drive U4 (not shown in Figure 45). This remote on feature can be used to wake up peripherals such as printers, scanners, external modems, disk drives, etc., as needed from a computer. Peripherals are usually designed to turn off automatically if they are not being used for a period of time, to save power. VCC (+5 V) + External Wake-up Signal High Voltage DC Input 100 k U2 27 k LOGIC LOGIC INPUT OUTPUT 1N4148 D U4 TOPSwitch-GX M CONTROL U3 Power Supply ON/OFF Control MICROPROCESSOR/ CONTROLLER 1N4148 6.8 k C 6.8 k P1 CM S 1 nF F U1 47 F U3 LTV817A P1 Switch Status U4 LTV817A RETURN PI-2561-030805 Figure 45. Remote ON/OFF using Microcontroller. 24 O 11/05 TOP242-250 In addition to using a minimum number of components, TOPSwitch-GX provides many technical advantages in this type of application: 1. Extremely low power consumption in the off mode: 80 mW typical at 110 VAC and 160 mW typical at 230 VAC. This is because, in the remote OFF mode, the TOPSwitch-GX consumes very little power and the external circuitry does not consume any current (either M, L or X pin is open) from the high voltage DC input. 2. A very low cost, low voltage/current, momentary contact switch can be used. 3. No debouncing circuitry for the momentary switch is required. During turn-on, the start-up time of the power supply (typically 10 ms to 20 ms) plus the microprocessor initiation time act as a debouncing filter, allowing a turn-on only if the switch is depressed firmly for at least the above delay time. During turn-off, the microprocessor initiates the shutdown sequence when it detects the first closure of the switch and subsequent bouncing of the switch has no effect. If necessary, the microprocessor could implement the switch debouncing in software during turn-off, or a filter capacitor can be used at the switch status input. 4. No external current limiting circuitry is needed for the operation of the U4 optocoupler output due to internal limiting of M pin current. 5. No high voltage resistors to the input DC voltage rail are required to power the external circuitry in the primary. Even the LED current for U3 can be derived from the CONTROL pin. This not only saves components and simplifies layout, but also eliminates the power loss associated with the high voltage resistors in both ON and OFF states. 6. Robust design: There is no ON/OFF latch that can be accidentally triggered by transients. Instead, the power supply is held in the ON-state through the secondary-side microprocessor. O 11/05 25 TOP242-250 Key Application Considerations TOPSwitch-II vs. TOPSwitch-GX Table 4 compares the features and performance differences between TOPSwitch-GX and TOPSwitch-II. Many of the new features eliminate the need for additional discrete components. Other features increase the robustness of design, allowing cost savings in the transformer and other power components. TOPSwitch-GX Advantages Function TOPSwitch-II TOPSwitch-GX Figures Soft-Start N/A* 10 ms External Current Limit N/A* Programmable 100% to 30% of default current limit 11,20,21, * Smaller transformer 24,25,27, * Higher efficiency 28,34,35, * Allows power limiting (constant 38,39 overload power independent of line voltage) * Allows use of larger device for lower losses, higher efficiency and smaller heatsink DCMAX 67% 78% 7 Line Feed-Forward N/A* with DC MAX Reduction 78% to 38% 7,11,17, * Rejects line ripple 26,27,28, 31,40 Line OV Shutdown N/A* Single resistor programmable 11,17,19, * Increases voltage withstand 26,27,28 capability against line surge 31,33,40 Line UV Detection N/A* Single resistor programmable 11,17,18, * Prevents auto-restart glitches 26,27,28, during power down 31,32,40 Switching Frequency 100 kHz 10% 132 kHz 6% 13,15 * Limits peak current and voltage component stresses during startup * Eliminates external components used for soft-start in most applications * Reduces or eliminates output overshoot * Smaller input cap (wider dynamic range) * Higher power capability (when used with RCD clamp for large VOR) * Allows use of Schottky secondary rectifier diode for up to 15 V output for high efficiency * Smaller transformer * Below start of conducted EMI limits Table 4. Comparison Between TOPSwitch-II and TOPSwitch-GX (continued on next page). *Not available 26 O 11/05 TOP242-250 TOPSwitch-GX Advantages Function TOPSwitch-II TOPSwitch-GX Figures Switching Frequency Option (Y, R and F Packages) N/A* 66 kHz 7% 14,15 * Lower losses when using RC and RCD snubber for noise reduction in video applications * Allows for higher efficiency in standby mode * Lower EMI (second harmonic below 150 kHz) Frequency Jitter N/A* 4 kHz @ 132 kHz 2 kHz @ 66 kHz 9,46 * Reduces conducted EMI Frequency Reduction N/A* At a duty cycle below 10% 7 * Zero load regulation without dummy load * Low power consumption at no-load Remote ON/OFF N/A* Single transistor or optocoupler interface or manual switch 11,22,23, 24,25,26, 27,29,36, 37,38,39, 40 * Fast ON/OFF (cycle-by-cycle) * Active-on or active-off control * Low consumption in remote off state * Active-on control for fail-safe * Eliminates expensive in-line on/off switch * Allows processor controlled turn on/off * Permits shutdown/wake-up of peripherals via LAN or parallel port Synchronization N/A* Single transistor or optocoupler interface * Synchronization to external lower frequency signal * Starts new switching cycle on demand Thermal Shutdown 125 C min. Latched Hysteretic 130 C min. shutdown (with 75 C hysteresis) * Automatic recovery from thermal fault * Large hysteresis prevents circuit board overheating Current Limit Tolerance 10% (@ 25 C) -8% (0 C to 100 C) 7% (@ 25 C) -4% Typical (0 C to 100 C)** * 10% Higher power capability due to tighter tolerance DIP 0.037" / 0.94 mm 0.137" / 3.48 mm SMD 0.037" / 0.94 mm 0.137" / 3.48 mm TO-220 0.046" / 1.17 mm 0.068" / 1.73 mm * Greater immunity to arcing as a result of build-up of dust, debris and other contaminants DRAIN Creepage at Package DRAIN Creepage at PCB for Y, R and F Packages 0.045" / 1.14 mm (R and F Package N/A*) 0.113" / 2.87 mm (performed leads) * Performed leads accommodate large creepage for PCB layout * Easier to meet Safety (UL/VDE) Table 4 (cont). Comparison Between TOPSwitch-II and TOPSwitch-GX. *Not available **Current limit set to internal maximum O 11/05 27 TOP242-250 Function TOPSwitch-FX TOPSwitch-GX TOPSwitch-GX Advantages Light Load Operation Cycle skipping Frequency and duty cycle reduction * Improves light load efficiency * Reduces no-load consumption Line Sensing/Externally Set Current Limit (Y, R and F Packages) Line sensing and externally set current limit mutually exclusive (M pin) Line sensing and * Additional design flexibility allows all externally set current features to be used simultaneously limit possible simultaneously (functions split onto L and X pins Current Limit Programming Range 100% to 40% 100% to 30% * Minimizes transformer core size in highly continuous designs P/G Package Current Identical to Y Limits package TOP243-246 P and G packages internal current limits reduced * Matches device current limit to package dissipation capability * Allows more continuous design to lower device dissipation (lower RMS currents) Y/R/F Package Current Limits 100% (R and F package N/A*) * Minimizes transformer core size * Optimizes efficiency for most applications Thermal Shutdown 125 C min. 70 C hysteresis 90% (for equivalent RDS(ON)) 130 C min. 75 C hysteresis * Allows higher output powers in high ambient temperature applications 90 A 60 A * Reduces output line frequency ripple at low line * DCMAX reduction optimized for forward designs using TOP248, TOP249 and TOP250 Line Under-Voltage Negative (turn-off) Threshold N/A* 40% of positive (turn-on) threshold * Provides a well defined turn-off threshold as the line voltage falls Soft-Start 10 ms (duty cycle) 10 ms (duty cycle + current limit) * Gradually increasing current limit in addition to duty cycle during soft-start further reduces peak current and voltage * Further reduces component stresses during start up Maximum Duty Cycle Reduction Threshold Table 5. Comparison Between TOPSwitch-FX and TOPSwitch-GX. *Not available TOPSwitch-FX vs. TOPSwitch-GX Table 5 compares the features and performance differences between TOPSwitch-GX and TOPSwitch-FX. Many of the new features eliminate the need for additional discrete components. Other features increase the robustness of design, allowing cost savings in the transformer and other power components. TOPSwitch-GX Design Considerations Power Table Data sheet power table (Table 1) represents the maximum practical continuous output power based on the following conditions: TOP242 to TOP246: 12 V output, Schottky output diode, 150 V reflected voltage (VOR) and efficiency estimates from curves contained in application note AN-29. TOP247 28 O 11/05 to TOP250: Higher output voltages, with a maximum output current of 6 A. For all devices, a 100 VDC minimum for 85-265 VAC and 250 VDC minimum for 230 VAC are assumed and sufficient heat sinking to keep device temperature 100 C. Power levels shown in the power table for the R package device assume 6.45 cm2 of 610 g/m2 copper heat sink area in an enclosed adapter, or 19.4 cm2 in an open frame. TOPSwitch-GX Selection Selecting the optimum TOPSwitch-GX depends upon required maximum output power, efficiency, heat sinking constraints and cost goals. With the option to externally reduce current limit, a larger TOPSwitch-GX may be used for lower power applications where higher efficiency is needed or minimal heat sinking is available. TOP242-250 Output Diode The output diode is selected for peak inverse voltage, output current, and thermal conditions in the application (including heatsinking, air circulation, etc.). The higher DCMAX of TOPSwitch-GX, along with an appropriate transformer turns ratio, can allow the use of a 60 V Schottky diode for higher efficiency on output voltages as high as 15 V (see Figure 41: A 12 V, 30 W design using a 60 V Schottky for the output diode). Bias Winding Capacitor Due to the low frequency operation at no-load a 1 F bias winding capacitor is recommended. Soft-Start Generally, a power supply experiences maximum stress at start-up before the feedback loop achieves regulation. For a period of 10 ms, the on-chip soft-start linearly increases the duty cycle from zero to the default DCMAX at turn on. In addition, the primary current limit increases from 85% to 100% over the same period. This causes the output voltage to rise in an orderly manner, allowing time for the feedback loop to take control of the duty cycle. This reduces the stress on the TOPSwitch-GX MOSFET, clamp circuit and output diode(s), and helps prevent The FREQUENCY pin of TOPSwitch-GX offers a switching frequency option of 132 kHz or 66 kHz. In applications that require heavy snubbers on the drain node for reducing high 70 PI-2576-010600 80 TOPSwitch-II (no jitter) 60 50 40 30 20 -10 0 EN55022B (QP) EN55022B (AV) -10 -20 0.15 1 10 30 Frequency (MHz) Figure 46a. TOPSwitch-II Full Range EMI Scan (100 kHz, No Jitter). 80 70 PI-2577-010600 A high VOR is required to take full advantage of the wider DCMAX of TOPSwitch-GX. An RCD clamp provides tighter clamp voltage tolerance than a Zener clamp and allows a VOR as high as 150 V. RCD clamp dissipation can be minimized by reducing the external current limit as a function of input line voltage (see Figures 21 and 35). The RCD clamp is more cost effective than the Zener clamp but requires more careful design (see Quick Design Checklist). EMI The frequency jitter feature modulates the switching frequency over a narrow band as a means to reduce conducted EMI peaks associated with the harmonics of the fundamental switching frequency. This is particularly beneficial for average detection mode. As can be seen in Figure 46, the benefits of jitter increase with the order of the switching harmonic due to an increase in frequency deviation. Amplitude (dBV) Primary Clamp and Output Reflected Voltage VOR A primary clamp is necessary to limit the peak TOPSwitch-GX drain to source voltage. A Zener clamp requires few parts and takes up little board space. For good efficiency, the clamp Zener should be selected to be at least 1.5 times the output reflected voltage VOR, as this keeps the leakage spike conduction time short. When using a Zener clamp in a universal input application, a VOR of less than 135 V is recommended to allow for the absolute tolerances and temperature variations of the Zener. This will ensure efficient operation of the clamp circuit and will also keep the maximum drain voltage below the rated breakdown voltage of the TOPSwitch-GX MOSFET. transformer saturation during start-up. Also, soft-start limits the amount of output voltage overshoot and, in many applications, eliminates the need for a soft-finish capacitor. TOPSwitch-GX (with jitter) 60 Amplitude (dBV) Input Capacitor The input capacitor must be chosen to provide the minimum DC voltage required for the TOPSwitch-GX converter to maintain regulation at the lowest specified input voltage and maximum output power. Since TOPSwitch-GX has a higher DCMAX than TOPSwitch-II, it is possible to use a smaller input capacitor. For TOPSwitch-GX, a capacitance of 2 F per watt is possible for universal input with an appropriately designed transformer. 50 40 30 20 -10 0 EN55022B (QP) EN55022B (AV) -10 -20 0.15 1 10 30 Frequency (MHz) Figure 46b. TOPSwitch-GX Full Range EMI Scan (132 kHz, With Jitter) with Identical Circuitry and Conditions. O 11/05 29 TOP242-250 frequency radiated noise (for example, video noise sensitive applications such as VCR, DVD, monitor, TV, etc.), operating at 66 kHz will reduce snubber loss resulting in better efficiency. Also, in applications where transformer size is not a concern, use of the 66 kHz option will provide lower EMI and higher efficiency. Note that the second harmonic of 66 kHz is still below 150 kHz, above which the conducted EMI specifications get much tighter. For 10 W or below, it is possible to use a simple inductor in place of a more costly AC input common mode choke to meet worldwide conducted EMI limits. Transformer Design It is recommended that the transformer be designed for maximum operating flux density of 3000 Gauss and a peak flux density of 4200 Gauss at maximum current limit. The turns ratio should be chosen for a reflected voltage (VOR) no greater than 135 V when using a Zener clamp, or 150 V (max) when using an RCD clamp with current limit reduction with line voltage (overload protection). For designs where operating current is significantly lower than the default current limit, it is recommended to use an externally set current limit close to the operating peak current to reduce peak flux density and peak power (see Figures 20 and 34). In most applications, the tighter current limit tolerance, higher switching frequency and soft-start features of TOPSwitch-GX contribute to a smaller transformer when compared to TOPSwitch-II. Standby Consumption Frequency reduction can significantly reduce power loss at light or no load, especially when a Zener clamp is used. For very low secondary power consumption, use a TL431 regulator for feedback control. Alternately, switching losses can be significantly reduced by changing from 132 kHz in normal operation to 66 kHz under light load conditions. TOPSwitch-GX Layout Considerations As TOPSwitch-GX has additional pins and operates at much higher power levels compared to previous TOPSwitch families, the following guidelines should be carefully followed. Primary Side Connections Use a single point (Kelvin) connection at the negative terminal of the input filter capacitor for the TOPSwitch-GX SOURCE pin and bias winding return. This improves surge capabilities by returning surge currents from the bias winding directly to the input filter capacitor. The CONTROL pin bypass capacitor should be located as close as possible to the SOURCE and CONTROL pins and its 30 O 11/05 SOURCE connection trace should not be shared by the main MOSFET switching currents. All SOURCE pin referenced components connected to the MULTI-FUNCTION, LINESENSE or EXTERNAL CURRENT LIMIT pins should also be located closely between their respective pin and SOURCE. Once again, the SOURCE connection trace of these components should not be shared by the main MOSFET switching currents. It is very critical that SOURCE pin switching currents are returned to the input capacitor negative terminal through a seperate trace that is not shared by the components connected to CONTROL, MULTI-FUNCTION, LINE-SENSE or EXTERNAL CURRENT LIMIT pins. This is because the SOURCE pin is also the controller ground reference pin. Any traces to the M, L or X pins should be kept as short as possible and away from the DRAIN trace to prevent noise coupling. LINE-SENSE resistor (R1 in Figures 47-49) should be located close to the M or L pin to minimize the trace length on the M or L pin side. In addition to the 47 F CONTROL pin capacitor, a high frequency bypass capacitor in parallel may be used for better noise immunity. The feedback optocoupler output should also be located close to the CONTROL and SOURCE pins of TOPSwitch-GX. Y-Capacitor The Y-capacitor should be connected close to the secondary output return pin(s) and the positive primary DC input pin of the transformer. Heat Sinking The tab of the Y package (TO-220) or F package (TO-262) is internally electrically tied to the SOURCE pin. To avoid circulating currents, a heat sink attached to the tab should not be electrically tied to any primary ground/source nodes on the PC board. When using a P (DIP-8), G (SMD-8) or R (TO-263) package, a copper area underneath the package connected to the SOURCE pins will act as an effective heat sink. On double sided boards (Figure 49), top side and bottom side areas connected with vias can be used to increase the effective heat sinking area. In addition, sufficient copper area should be provided at the anode and cathode leads of the output diode(s) for heat sinking. In Figures 47, 48 and 49, a narrow trace is shown between the output rectifier and output filter capacitor. This trace acts as a thermal relief between the rectifier and filter capacitor to prevent excessive heating of the capacitor. TOP242-250 Maximize hatched copper areas ( ) for optimum heat sinking Safety Spacing Y1Capacitor + HV - Output Rectifier Output Filter Capacitor Input Filter Capacitor PRI BIAS S S PRI D TOPSwitch-GX TOP VIEW S M S BIAS T r a n s f o r m e r SEC C Optocoupler R1 DC + Out - R2 PI-2670-042301 Figure 47. Layout Consideratiions for TOPSwitch-GX using P or G Package. Safety Spacing Y1Capacitor + Maximize hatched copper areas ( ) for optimum heat sinking Input Filter Capacitor HV Output Rectifier Output Filter Capacitor - TOPSwitch-GX D X L TOP VIEW R1 C Heat Sink T r a n s f o r m e r Optocoupler SEC - DC + Out PI-2669-042301 Figure 48. Layout Consideratiions for TOPSwitch-GX using Y or F Package. O 11/05 31 TOP242-250 Output Filter Capacitors Solder Side Safety Spacing Component Side Y1Capacitor + TOP VIEW HV PRI Input Filter Capacitor - PRI R1a - 1c T r a n s f o r m e r SEC BIAS D S X L C Optocoupler TOPSwitch-GX DC Out + Maximize hatched copper areas ( ) for optimum heat sinking PI-2734-043001 Figure 49. Layout Considerations for TOPSwitch-GX using R Package. Quick Design Checklist As with any power supply design, all TOPSwitch-GX designs should be verified on the bench to make sure that components specifications are not exceeded under worst case conditions. The following minimum set of tests is strongly recommended: 1. Maximum drain voltage - Verify that peak VDS does not exceed 675 V at highest input voltage and maximum overload output power. Maximum overload output power occurs when the output is overloaded to a level just before the power supply goes into auto-restart (loss of regulation). 2. Maximum drain current - At maximum ambient temperature, maximum input voltage and maximum output load, verify drain current waveforms at start-up for any signs of transformer saturation and excessive leading edge current spikes. TOPSwitch-GX has a leading edge blanking time of 220 ns to prevent premature termination of the ON-cycle. Verify that the leading edge current spike is below the allowed current limit envelope (see Figure 52) for the drain current waveform at the end of the 220 ns blanking period. 32 O 11/05 3. Thermal check - At maximum output power, minimum input voltage and maximum ambient temperature, verify that temperature specifications are not exceeded for TOPSwitch-GX, transformer, output diodes and output capacitors. Enough thermal margin should be allowed for the part-to-part variation of the RDS(ON) of TOPSwitch-GX, as specified in the data sheet. The margin required can either be calculated from the tolerances or it can be accounted for by connecting an external resistance in series with the DRAIN pin and attached to the same heatsink, having a resistance value that is equal to the difference between the measured RDS(ON) of the device under test and the worst case maximum specification. Design Tools For a discussion on utilizing TOP248, TOP249 and TOP250 in forward converter configurations, please refer to the TOPSwitch-GX Forward Design Methodology Application Note. Up-to-date information on design tools can be found at the Power Integrations website: www.powerint.com TOP242-250 ABSOLUTE MAXIMUM RATINGS(1,4) DRAIN Voltage .................................................. -0.3 V to 700 V DRAIN Peak Current: TOP242......................................0.72 A TOP243....................................... 1.44 A TOP244..........................................2.16 A TOP245....................................... 2.88 A TOP246..........................................4.32 A TOP247..........................................5.76 A TOP248..........................................7.20 A TOP249..........................................8.64 A TOP250 ........................................10.08 A CONTROL Voltage ................................................ -0.3 V to 9 VCONTROL Current .................................................... 100 mA LINE SENSE Pin Voltage ................................... -0.3 V to 9 V CURRENT LIMIT Pin Voltage ........................-0.3 V to 4.5 V MULTI-FUNCTION Pin Voltage ........................-0.3 V to 9 V FREQUENCY Pin Voltage ..................................-0.3 V to 9 V Storage Temperature ..................................... -65 C to 150 C Operating Junction Temperature(2) ................ -40 C to 150 C Lead Temperature(3) ...................................................... 260 C Notes: 1. All voltages referenced to SOURCE, TA = 25 C. 2. Normally limited by internal circuitry. 3. 1/16 in. from case for 5 seconds. 4. Maximum ratings specified may be applied one at a time, without causing permanent damage to the product. Exposure to Absolute Maximum Rating conditions for extended periods of time may affect product reliability. THERMAL IMPEDANCE Thermal Impedance: Y or F Package: (JA)(1) .......................... ..................... 80 C/W (JC)(2) ................................................ . 2 C/W P or G Package: (JA) ............................ 70 C/W(3); 60 C/W(4) (JC)(5) ................................................ 11 C/W R Package: (JA) ..........80 C/W(7); 40 C/W(4); 30 C/W(6) (JC)(5) .................................................. 2 C/W Notes: 1. Free standing with no heatsink. 2. Measured at the back surface of tab. 3. Soldered to 0.36 sq. in. (232 mm2), 2 oz. (610 g/m2) copper clad. 4. Soldered to 1 sq. in. (645 mm2), 2 oz. (610 g/m2) copper clad. 5. Measured on the SOURCE pin close to plastic interface. 6. Soldered to 3 sq. in. (1935 mm2), 2 oz. (610 g/m2) copper clad. 7. Soldered to foot print area, 2 oz. (610 g/m2) copper clad. Conditions Parameter Symbol SOURCE = 0 V; TJ = -40 to 125 C See Figure 53 (Unless Otherwise Specified) Min Typ Max FREQUENCY Pin Connected to SOURCE 124 132 140 FREQUENCY Pin Connected to CONTROL 61.5 66 70.5 Units CONTROL FUNCTIONS Switching Frequency (average) fOSC Duty Cycle at ONSET of Frequency Reduction DC(ONSET) Switching Frequency near 0% Duty Cycle fOSC(DMIN) Frequency Jitter Deviation f Frequency Jitter Modulation Rate fM IC = 3 mA; TJ = 25 C kHz 10 132 kHz Operation 30 66 kHz Operation 15 132 kHz Operation 4 66 kHz Operation 2 % kHz kHz 250 Hz O 11/05 33 TOP242-250 Conditions Parameter Symbol SOURCE = 0 V; TJ = -40 to 125 C See Figure 53 (Unless Otherwise Specified) Min Typ Max IL IL(DC) or IM IM(DC) 75 78 83 IL or IM = 190 A TOP242-247 28 38 50 Units CONTROL FUNCTIONS (cont.) Maximum Duty Cycle Soft-Start Time PWM Gain PWM Gain Temperature Drift External Bias Current DCMAX IL or IM = 100 A TOP242-247 IC = ICD1 33 41.3 49.5 IL = 100 A TOP248-250 60 66.8 73.5 10 15 ms -23 -18 %/mA tSOFT TJ = 25 C; DCMIN to DCMAX DCreg IC = 4 mA; TJ = 25 C Charging Current Temperature Drift Auto-Restart Upper Threshold Voltage Auto-Restart Lower Threshold Voltage 34 O 11/05 -28 See Note A IB See Figure 7 IC(CH) -0.01 TOP242-245 TOP246-249 TOP250 TOP242-245 TOP246-249 TOP250 TJ = 25 C 1.2 1.6 1.7 10 %/mA/C 2.0 2.6 2.7 6.0 6.6 7.3 3.0 4.0 4.2 7.0 8.0 8.5 15 22 7 kHz -3.5 -2.0 VC = 5 V -3.0 -1.8 -0.6 4.5 mA %/C -5.0 VC(AR)U mA 0.18 VC = 0 V See Note A VC(AR)L % IL = 190 A TOP248-250 CONTROL IC(OFF) TJ = 25 C Current at 0% Duty Cycle Dynamic IC = 4 mA; TJ = 25 C ZC See Figure 51 Impedance Dynamic Impedance Temperature Drift CONTROL Pin Internal Filter Pole SHUTDOWN/AUTO-RESTART CONTROL Pin Charging Current 66.5 mA 0.5 %/C 5.8 V 4.8 5.1 V TOP242-250 Conditions Parameter Symbol SOURCE = 0 V; TJ = -40 to 125 C See Figure 53 (Unless Otherwise Specified) Min Typ 0.8 1.0 Max Units SHUTDOWN/AUTO-RESTART (cont.) Auto-Restart Hysteresis Voltage VC(AR)hyst Auto-Restart Duty Cycle DC(AR) 4 f(AR) 1.0 Auto-Restart Frequency V 8 % Hz MULTI-FUNCTION (M), LINE-SENSE (L) AND EXTERNAL CURRENT LIMIT (X) INPUTS Line UnderVoltage Threshold Current and Hysteresis (M or L Pin) Line Overvoltage or Remote ON/OFF Threshold Current and Hysteresis (M or L Pin) L Pin Voltage Threshold Threshold IUV 44 Threshold 210 L or M Pin Short Circuit Current IL(SC) or IM(SC) X or M Pin Short Circuit Current IX(SC) or IM(SC) L or M Pin Voltage (Positive Current) VL, VM X Pin Voltage (Negative Current) VX M Pin Voltage (Negative Current) VM 225 A 240 A TJ = 25 C VL(TH) IREM (N) A 30 Hysteresis Remote ON/OFF Negative Threshold Current and Hysteresis (M or X Pin) 54 TJ = 25 C Hysteresis IOV 50 Threshold 8 A 0.5 1.0 1.6 V -35 -27 -20 A TJ = 25 C Hysteresis VL, VM = VC VX, VM = 0 V 5 A 300 400 520 Normal Mode -300 -240 -180 Auto-Restart Mode -110 -90 -70 IL or IM = 50 A 1.90 2.50 3.00 IL or IM = 225 A 2.30 2.90 3.30 IX = -50 A 1.26 1.33 1.40 IX = -150 A 1.18 1.24 1.30 IM = -50 A 1.24 1.31 1.39 IM = -150 A 1.13 1.19 1.25 A A V V V O 11/05 35 TOP242-250 Conditions Parameter Symbol SOURCE = 0 V; TJ = -40 to 125 C See Figure 53 (Unless Otherwise Specified) Min Typ Max Units MULTI-FUNCTION, LINSE-SENSE AND EXTERNAL CURRENT LIMIT INPUTS (cont.) Maximum Duty Cycle Reduction Onset Threshold Current IL(DC) or IM(DC) TJ = 25 C 40 X, L or M Pin Floating L or M Pin Shorted to CONTROL 60 75 0.6 1.0 1.0 1.6 A Remote OFF DRAIN Supply Current ID(RMT) See Figure 71 VDRAIN = 150 V Remote ON Delay tR(ON) From Remote ON to Drain Turn-On See Note B 2.5 s Minimum Time Before Drain Turn-On to Disable Cycle, See Note B 2.5 s See Note B 2.9 V Remote OFF tR(OFF) Setup Time FREQUENCY INPUT FREQUENCY Pin VF Threshold Voltage FREQUENCY Pin IF Input Current CIRCUIT PROTECTION Self Protection Current Limit (See Note C) ILIMIT VF = VC O 11/05 40 100 TOP242 P/G TOP242 Y/R/F TJ = 25 C Internal di/dt = 90 mA/s 0.418 0.45 0.481 TOP243 P/G TJ = 25 C Internal di/dt = 150 mA/s 0.697 0.75 0.802 TOP243 Y/R/F TJ = 25 C Internal di/dt = 180 mA/s 0.837 0.90 0.963 TOP244 P/G TJ = 25 C Internal di/dt = 200 mA/s 0.930 1.00 1.070 TOP244 Y/R/F TJ = 25 C Internal di/dt = 270 mA/s 1.256 1.35 1.445 Internal di/dt = 220 mA/s 1.02 1.10 1.18 TOP245 Y/R/F TJ = 25 C Internal di/dt = 360 mA/s 1.674 1.80 1.926 TOP246 P/G TJ = 25 C Internal di/dt = 270 mA/s 1.256 1.35 1.445 TOP246 Y/R/F TJ = 25 C Internal di/dt = 540 mA/s 2.511 2.70 2.889 Internal di/dt = 720 mA/s 3.348 3.60 3.852 TOP245 P/G TJ = 25 C TOP247 Y/R/F TJ = 25 C 36 10 mA A A TOP242-250 Conditions Parameter Symbol SOURCE = 0 V; TJ = -40 to 125 C See Figure 53 (Unless Otherwise Specified) Min Typ Max Units CIRCUIT PROTECTION (cont.) Self Protection Current Limit (See Note C) Initial Current Limit ILIMIT IINIT Leading Edge tLEB Blanking Time Current Limit tIL(D) Delay Thermal Shutdown Temperature Thermal Shutdown Hysteresis Power-Up Reset VC(RESET) Threshold Voltage OUTPUT TOP248 Y/R/F TJ = 25 C Internal di/dt = 900 mA/s 4.185 4.50 4.815 TOP249 Y/R/F TJ = 25 C Internal di/dt = 1080 mA/s 5.022 5.40 5.778 TOP250 Y/R/F TJ = 25 C Internal di/dt = 1260 mA/s 5.859 6.30 6.741 See Note B A 265 VAC 0.6 x (Rectified Line Input) ILIMIT(MIN) 220 ns IC = 4 mA 100 ns 130 TOP244 ID = 150 mA TOP245 ID = 200 mA TOP246 ID = 300 mA TOP247 ID = 400 mA TOP248 ID = 500 mA 140 150 C 75 Figure 53, S1 Open TOP243 ID = 100 mA RDS(ON) 85 VAC 0.75 x (Rectified Line Input) ILIMIT(MIN) See Figure 52 TJ = 25 C, IC = 4 mA TOP242 ID = 50 mA ON-State Resistance A 1.75 C 3.0 4.25 TJ = 25 C 15.6 18.0 TJ = 100 C 25.7 30.0 TJ = 25 C 7.80 9.00 TJ = 100 C 12.9 15.0 TJ = 25 C 5.20 6.00 TJ = 100 C 8.60 10.0 TJ = 25 C 3.90 4.50 TJ = 100 C 6.45 7.50 TJ = 25 C 2.60 3.00 TJ = 100 C 4.30 5.00 TJ = 25 C 1.95 2.25 TJ = 100 C 3.22 3.75 TJ = 25 C 1.56 1.80 TJ = 100 C 2.58 3.00 V O 11/05 37 TOP242-250 Conditions Parameter Symbol SOURCE = 0 V; TJ = -40 to 125 C See Figure 53 (Unless Otherwise Specified) Min Typ Max TJ = 25 C 1.30 1.50 TJ = 100 C 2.15 2.50 TJ = 25 C 1.10 1.28 TJ = 100 C 1.85 2.15 Units OUTPUT (cont.) ON-State Resistance RDS(ON) TOP249 ID = 600 mA TOP250 ID = 700 mA OFF-State Drain VL, VM = Floating; IC = 4 mA IDSS VDS = 560 V; TJ = 125 C Leakage Current Breakdown VL, VM = Floating; IC = 4 mA BVDSS See Note D, TJ = 25 C Voltage tR Rise Time Measured in a Typical Flyback Converter Application tF Fall Time SUPPLY VOLTAGE CHARACTERISTICS DRAIN Supply See Note E Voltage Shunt Regulator VC(SHUNT) IC = 4 mA Voltage Shunt Regulator Temperature Drift Control Supply/ Discharge Current ICD1 ICD2 Output MOSFET Enabled VX, VL, VM = 0 V 470 700 100 ns 50 ns V 5.85 6.10 50 V ppm/C TOP242-245 1.0 1.6 2.5 TOP246-249 1.2 2.2 3.2 TOP250 1.3 2.4 3.65 0.3 0.6 1.3 Output MOSFET Disabled VX, VL, VM = 0 V A V 36 5.60 mA NOTES: A. For specifications with negative values, a negative temperature coefficient corresponds to an increase in magnitude with increasing temperature, and a positive temperature coefficient corresponds to a decrease in magnitude with increasing temperature. B. Guaranteed by characterization. Not tested in production. C. For externally adjusted current limit values, please refer to Figures 54b, 55b and 56b (Current Limit vs. External Current Limit Resistance) in the Typical Performance Characteristics section. The tolerance specified is only valid at full current limit. D. Breakdown voltage may be checked against minimum BVDSS specification by ramping the DRAIN pin voltage up to but not exceeding minimum BVDSS. E. It is possible to start up and operate TOPSwitch-GX at DRAIN voltages well below 36 V. However, the CONTROL pin charging current is reduced, which affects start-up time, auto-restart frequency, and auto-restart duty cycle. Refer to Figure 68, the characteristic graph on CONTROL pin charge current (IC) vs. DRAIN voltage for low voltage operation characteristics. 38 O 11/05 TOP242-250 t2 HV t1 90% 90% DRAIN VOLTAGE t D= 1 t2 10% 0V PI-2039-033001 100 DRAIN Current (normalized) PI-1939-091996 CONTROL Pin Current (mA) 120 80 60 40 Dynamic 1 = Impedance Slope 20 tLEB (Blanking Time) 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 PI-2022-033001 Figure 50. Duty Cycle Measurement. IINIT(MIN) @ 85 VAC IINIT(MIN) @ 265 VAC ILIMIT(MAX) @ 25 C ILIMIT(MIN) @ 25 C 0 0 2 4 6 8 10 0 1 CONTROL Pin Voltage (V) 3 4 5 7 6 8 Time (s) Figure 51. CONTROL Pin I-V Characteristic. Figure 52. Drain Current Operating Envelope. Y or R Package (X and L Pins) S1 2 P or G Package (M Pin) 0-100 k 470 5W 0-100 k S5 5-50 V 5-50 V M 0-60 k 40 V L 470 C D CONTROL C TOPSwitch-GX S2 S4 0-15 V 47 F 0.1 F F X S S3 0-60 k NOTES: 1. This test circuit is not applicable for current limit or output characteristic measurements. 2. For P and G packages, short all SOURCE pins together. PI-2631-081204 Figure 53. TOPSwitch-GX General Test Circuit. O 11/05 39 TOP242-250 BENCH TEST PRECAUTIONS FOR EVALUATION OF ELECTRICAL CHARACTERISTICS The following precautions should be followed when testing TOPSwitch-GX by itself outside of a power supply. The schematic shown in Figure 53 is suggested for laboratory testing of TOPSwitch-GX. When the DRAIN pin supply is turned on, the part will be in the auto-restart mode. The CONTROL pin voltage will be oscillating at a low frequency between 4.8 V and 5.8 V and the drain is turned on every eigth cycle of the CONTROL pin oscillation. If the CONTROL pin power supply is turned on while in this auto-restart mode, there is only a 12.5% chance that the CONTROL pin oscillation will be in the correct state (drain active state) so that the continuous drain voltage waveform may be observed. It is recommended that the VC power supply be turned on first and the DRAIN pin power supply second if continuous drain voltage waveforms are to be observed. The 12.5% chance of being in the correct state is due to the divideby-8 counter. Temporarily shorting the CONTROL pin to the SOURCE pin will reset TOPSwitch-GX, which then will come up in the correct state. Typical Performance Characteristics PI-2653-031904 Scaling Factors: TOP242 P/G/Y/R/F: .45 TOP243 P/G: .75 TOP243 Y/R/F: .90 TOP244 P/G: 1 TOP244 Y/R/F: 1.35 TOP245 Y/R/F: 1.80 TOP246 Y/R/F: 2.70 TOP247 Y/R/F: 3.60 TOP248 Y/R/F 4.50 TOP249 Y/R/F: 5.40 TOP250 Y/R/F: 6.32 1.0 Current Limit (A) 0.9 0.8 0.7 0.6 0.5 200 180 160 140 120 100 0.4 80 0.3 60 0.2 -250 -200 -150 -100 di/dt (mA/s) 1.1 40 0 -50 IX or IM (A) Figure 54a. Current Limit vs. X or M Pin Current (see Figures 55a and 56a for TOP245P/G and TOP246P/G). PI-2652-042303 Scaling Factors: TOP242 P/G/Y/R/F: .45 TOP243 P/G: .75 TOP243 Y/R/F: .90 TOP244 P/G: 1 TOP244 Y/R/F: 1.35 TOP245 Y/R/F: 1.80 TOP246 Y/R/F: 2.70 TOP247 Y/R/F: 3.60 TOP248 Y/R/F 4.50 TOP249 Y/R/F: 5.40 TOP250 Y/R/F: 6.32 1.0 Current Limit (A) 0.9 0.8 Maximum 0.7 Minimum 0.6 Typical 0.5 0.4 180 160 140 120 100 80 Maximum and minimum levels are based on characterization. 0.3 0.2 200 0 5K 10K 60 15K 20K 25K 30K 35K 40K 40 45K External Current Limit Resistor RIL () Figure 54b. Current Limit vs. External Current Limit Resistance (see Figures 55b and 56b for TOP245P/G and TOP246P/G). 40 O 11/05 di/dt (mA/s) 1.1 TOP242-250 PI-3652-110405 Scaling Factor: TOP245P/G: 1.1 Current Limit (A) 1.0 200 0.9 180 0.8 160 0.7 140 0.6 120 0.5 100 0.4 80 0.3 60 0.2 -250 -200 -150 -100 -50 0 di/dt (mA/s) 1.1 40 IM (A) Figure 55a. Current Limit vs. MULTI-FUNCTION Pin Current (TOP245P/G only). PI-3651-110405 1.1 Scaling Factor: TOP245P/G: 1.1 1.0 200 Current Limit (A) 0.8 160 Refer to MULTIFUNCTION (M) Pin Operation section 0.7 140 0.6 120 Typical 0.5 100 0.4 80 Measured at 25 C. 0.3 0.2 di/dt (mA/s) 180 0.9 0 5K 60 10K 15K 20K 25K 30K 35K 40K 40 45K External Current Limit Resistor RIL () 1.25 PI-3653-073003 Current Limit (Normalized to 25 C) Figure 55b. Current Limit vs. External Current Limit Resistance (TOP245P/G only). 1.20 1.15 0 C 1.10 1.05 1.00 .95 25 C .90 .85 .80 100 C .75 .70 0 5K 10K 15K 20K 25K 30K 35K 40K 45K External Current Limit Resistor RIL () Figure 55c. External Current Limit vs. External Current Limit Resistance at 0 C, 25 C and 100 C Junction Temperature (TOP245P/G only). O 11/05 41 TOP242-250 PI-3724-110405 Scaling Factor: TOP246P/G: 1.35 Current Limit (A) 1.0 200 0.9 180 0.8 160 0.7 140 0.6 120 0.5 100 0.4 80 0.3 60 di/dt (mA/s) 1.1 40 0.2 -250 -200 -150 -100 -50 0 IM (A) Figure 56a. Current Limit vs. MULTI-FUNCTION Pin Current (TOP246P/G only). PI-3725-110405 1.1 Scaling Factor: TOP246P/G: 1.35 1.0 180 0.8 160 Refer to MULTIFUNCTION (M) Pin Operation section 0.7 140 0.6 120 Typical 0.5 100 0.4 80 Measured at 25 C. 0.3 60 0.2 0 5K 10K 15K 20K 25K 30K 35K 40K 40 45K External Current Limit Resistor RIL () 1.25 PI-3726-100703 Current Limit (Normalized to 25 C) Figure 56b. Current Limit vs. External Current Limit Resistance (TOP246P/G only). 1.20 0 C 1.15 1.10 1.05 1.00 .95 25 C .90 .85 .80 100 C .75 .70 0 5K 10K 15K 20K 25K 30K 35K 40K 45K External Current Limit Resistor RIL () Figure 56c. External Current Limit vs. External Current Limit Resistance at 0 C, 25 C and 100 C Junction Temperature (TOP246P/G only). 42 O 11/05 di/dt (mA/s) Current Limit (A) 0.9 200 TOP242-250 Typical Performance Characteristics (cont.) 1.0 PI-1123A-033001 1.2 Output Frequency (Normalized to 25 C) PI-176B-033001 1.0 0.8 0.6 0.4 0.2 0 0.9 -50 -25 0 25 50 75 100 125 150 -50 -25 Junction Temperature (C) 75 100 125 150 0.8 0.6 0.4 1.2 0.2 1.0 0.8 0.6 Use for TOP242-250 Y/R/F packages and TOP242-244 P/G packages only. See Figures 55c and 56c for TOP245P/G and TOP246P/G. 0.4 0.2 0 0 -50 -25 0 25 50 -50 -25 75 100 125 150 PI-2553-033001 1.0 25 50 75 100 125 150 Figure 60. External Current Limit vs. Temperature with RIL = 12 k. 0.8 0.6 0.4 0.2 1.2 Under-Voltage Threshold (Normalized to 25 C) Figure 59. Internal Current Limit vs. Temperature. 1.2 0 Junction Temperature (C) Junction Temperature (C) Overvoltage Threshold (Normalized to 25 C) 50 PI-2554-110705 PI-2555-033001 Current Limit (Normalized to 25 C) 1.0 25 Figure 58. Frequency vs. Temperature. Current Limit (Normalized to 25 C) Figure 57. Breakdown Voltage vs. Temperature. 1.2 0 Junction Temperature (C) PI-2552-033001 Breakdown Voltage (Normalized to 25 C) 1.1 1.0 0.8 0.6 0.4 0.2 0 0 -50 -25 0 25 50 75 100 125 150 Junction Temperature (C) Figure 61. Overvoltage Threshold vs. Temperature. -50 -25 0 25 50 75 100 125 150 Junction Temperature (C) Figure 62. Under-Voltage Threshold vs. Temperature. O 11/05 43 TOP242-250 Typical Performance Characteristics (cont.) 5.0 4.5 4.0 3.5 3.0 2.5 1.4 1.0 0.8 0.6 0.4 0.2 0 300 400 -240 PI-2542-102700 MULTI-FUNCTION Pin Voltage (V) Figure 63a. LINE-SENSE Pin Voltage vs. Current. 6 5 4 3 2 See Expanded Version 1 0 -300 -200 -100 0 0 1.4 VM = 1.37 - IMx 1 k -200 A IM -25 A 1.2 1.0 0.8 0.6 0.4 0.2 0 -300 -250 -200 -150 -100 -50 0 MULTI-FUNCTION Pin Current (A) PI-2562-033001 0.8 0.6 0.4 0.2 0 Figure 64b. MULTI-FUNCTION Pin Voltage vs. Current (Expanded). 1.2 Onset Threshold Current (Normalized to 25 C) Figure 64a. MULTI-FUNCTION Pin Voltage vs. Current. CONTROL Current (Normalized to 25 C) -60 1.6 MULTI-FUNCTION Pin Current (A) 1.0 -120 Figure 63b. EXTERNAL CURRENT LIMIT Pin Voltage vs. Current. 100 200 300 400 500 1.2 -180 EXTERNAL CURRENT LIMIT Pin Current (A) LINE-SENSE Pin Current (A) PI-2541-102700 200 PI-2563-033001 100 MULTI-FUNCTION Pin Voltage (V) 0 1.0 0.8 0.6 0.4 0.2 0 -50 -25 0 25 50 75 100 125 150 Junction Temperature (C) Figure 65. Control Current Out at 0% Duty Cycle vs. Temperaure. O 11/05 VX = 1.33 - IXx 0.66 k -200 A IX -25 A 1.2 2.0 44 PI-2689-102300 5.5 1.6 EXTERNAL CURRENT LIMIT Pin Voltage (V) PI-2688-102700 LINE SENSE Pin Voltage (V) 6.0 -50 -25 0 25 50 75 100 125 150 Junction Temperature (C) Figure 66. Max. Duty Cycle Reduction Onset Threshold Current vs. Temperature. TOP242-250 CONTROL Pin Charging Current (mA) 5 4 Scaling Factors: TOP250 1.17 TOP249 1.00 TOP248 0.83 TOP247 0.67 TOP246 0.50 TOP245 0.33 TOP244 0.25 TCASE = 25 C TOP243 0.17 TCASE = 100 C TOP242 0.08 3 2 1 VC = 5 V 1.6 1.2 0.8 0.4 0 0 0 2 4 6 0 8 10 12 14 16 18 20 20 Figure 67. Output Characteristics. PI-2646-010802 100 500 600 Scaling Factors: TOP250 1.17 TOP249 1.00 TOP248 0.83 TOP247 0.67 TOP246 0.50 TOP245 0.33 TOP244 0.25 TOP243 0.17 TOP242 0.08 500 Power (mW) DRAIN Capacitance (pF) 80 600 Scaling Factors: TOP250 1.17 TOP249 1.00 TOP248 0.83 TOP247 0.67 TOP246 0.50 TOP245 0.33 TOP244 0.25 TOP243 0.17 TOP242 0.08 100 60 Figure 68. IC vs. DRAIN Voltage. 10000 1000 40 DRAIN Voltage (V) DRAIN Voltage (V) PI-2650-020802 DRAIN Current (A) 2 PI-2645-010802 6 PI-2564-101499 Typical Performance Characteristics (cont.) 400 300 200 100 10 0 100 200 300 400 500 0 600 0 100 Figure 69. COSS vs. DRAIN Voltage. 300 400 Figure 70. DRAIN Capacitance Power. 1.2 PI-2690-102700 Remote OFF DRAIN Supply Current (Normalized to 25 C) 200 DRAIN Voltage (V) Drain Voltage (V) 1.0 0.8 0.6 0.4 0.2 0 -50 0 50 100 150 Junction Temperature (C) Figure 71. Remote OFF DRAIN Supply Current vs. Temperature. O 11/05 45 TOP242-250 PART ORDERING INFORMATION TOPSwitch Product Family GX Series Number Package Identifier G Plastic SMD-8B (TOP242-246 only) P Plastic DIP-8B (TOP242-246 only) Y Plastic TO-220-7C R Plastic TO-263-7C (available only with TL option) F Plastic TO-262-7C Lead Finish Blank Standard (Sn Pb) N Pure Matte Tin (Pb-Free) (P, G, Y & F Packages) Tape & Reel and Other Options TOP 242 G N - TL 46 O 11/05 Blank Standard Configurations TL Tape & Reel, (G Package: 1000 min., R Package: 750 min.) TOP242-250 TO-220-7C .165 (4.19) .185 (4.70) .390 (9.91) .420 (10.67) .146 (3.71) .156 (3.96) .108 (2.74) REF + .045 (1.14) .055 (1.40) .234 (5.94) .261 (6.63) .570 (14.48) REF. .461 (11.71) .495 (12.57) 7 TYP. .860 (21.84) .880 (22.35) .670 (17.02) REF. .080 (2.03) .120 (3.05) .068 (1.73) MIN .024 (.61) .010 (.25) M .034 (.86) .050 (1.27) BSC PIN 1 .150 (3.81) BSC PIN 2 & 4 PIN 1 & 7 .040 (1.02) .060 (1.52) .040 (1.02) .060 (1.52) .012 (.30) .024 (.61) .190 (4.83) .210 (5.33) .050 (1.27) .050 (1.27) .050 (1.27) .050 (1.27) .180 (4.58) .200 (5.08) .100 (2.54) PIN 7 PIN 1 .150 (3.81) Y07C .150 (3.81) Notes: 1. Controlling dimensions are inches. Millimeter dimensions are shown in parentheses. 2. Pin numbers start with Pin 1, and continue from left to right when viewed from the front. 3. Dimensions do not include mold flash or other protrusions. Mold flash or protrusions shall not exceed .006 (.15mm) on any side. 4. Minimum metal to metal spacing at the package body for omitted pin locations is .068 in. (1.73 mm). 5. Position of terminals to be measured at a location .25 (6.35) below the package body. 6. All terminals are solder plated. MOUNTING HOLE PATTERN PI-2644-122004 O 11/05 47 TOP242-250 DIP-8B D S .004 (.10) -E- Notes: 1. Package dimensions conform to JEDEC specification MS-001-AB (Issue B 7/85) for standard dual-in-line (DIP) package with .300 inch row spacing. 2. Controlling dimensions are inches. Millimeter sizes are shown in parentheses. 3. Dimensions shown do not include mold flash or other protrusions. Mold flash or protrusions shall not exceed .006 (.15) on any side. 4. Pin locations start with Pin 1, and continue counter-clockwise to Pin 8 when viewed from the top. The notch and/or dimple are aids in locating Pin 1. Pin 6 is omitted. 5. Minimum metal to metal spacing at the package body for the omitted lead location is .137 inch (3.48 mm). 6. Lead width measured at package body. 7. Lead spacing measured with the leads constrained to be perpendicular to plane T. .137 (3.48) MINIMUM .240 (6.10) .260 (6.60) Pin 1 -D- .367 (9.32) .387 (9.83) .125 (3.18) .145 (3.68) -T- .015 (.38) MINIMUM SEATING PLANE .100 (2.54) BSC .057 (1.45) .068 (1.73) (NOTE 6) .008 (.20) .015 (.38) .120 (3.05) .140 (3.56) .300 (7.62) BSC (NOTE 7) .300 (7.62) .390 (9.91) .048 (1.22) .053 (1.35) .014 (.36) .022 (.56) T E D S .010 (.25) M P08B PI-2551-121504 SMD-8B D S .004 (.10) .137 (3.48) MINIMUM -E- .372 (9.45) .388 (9.86) E S .010 (.25) .240 (6.10) .260 (6.60) Pin 1 .100 (2.54) (BSC) -D- .367 (9.32) .387 (9.83) .057 (1.45) .068 (1.73) (NOTE 5) .125 (3.18) .145 (3.68) .032 (.81) .037 (.94) .048 (1.22) .053 (1.35) Notes: 1. Controlling dimensions are inches. Millimeter sizes are shown in parentheses. 2. Dimensions shown do not include mold flash or other protrusions. Mold flash or protrusions shall not exceed .006 (.15) on any side. .420 3. Pin locations start with Pin 1, and continue counter-clock.046 .060 .060 .046 wise to Pin 8 when viewed from the top. Pin 6 is omitted. 4. Minimum metal to metal .080 spacing at the package body Pin 1 for the omitted lead location is .137 inch (3.48 mm). .086 5. Lead width measured at .186 package body. .286 6. D and E are referenced Solder Pad Dimensions datums on the package body. .004 (.10) .009 (.23) .004 (.10) .012 (.30) .036 (0.91) .044 (1.12) 0- 8 G08B PI-2546-121504 48 O 11/05 TOP242-250 TO-263-7C .390 (9.91) .420 (10.67) .045 (1.14) .055 (1.40) .245 (6.22) MIN .055 (1.40) .066 (1.68) .326 (8.28) .336 (8.53) .225 (5.72) MIN .580 (14.73) .620 (15.75) .208 (5.28) Ref. -A0.68 (1.73) MIN LD #1 .024 (0.61) .034 (0.86) .100 (2.54) REF .050 (1.27) .000 (0.00) .010 (0.25) .090 (2.29) .110 (2.79) .010 (0.25) .012 (0.30) .024 (0.61) 0- 8 .315 (8.00) .380 (9.65) Solder Pad Dimensions .638 (16.21) .128 (3.25) .050 (1.27) .038 (0.97) .165 (4.19) .185 (4.70) .004 (0.10) Notes: 1. Package Outline Exclusive of Mold Flash & Metal Burr. 2. Package Outline Inclusive of Plating Thickness. 3. Foot Length Measured at Intercept Point Between Datum A Lead Surface. 4. Controlling Dimensions are in Inches. Millimeter Dimensions are shown in Parentheses. R07C 5. Minimum metal to metal spacing at the package body for the omitted pin locations is .068 in. (1.73 mm). PI-2664-122004 O 11/05 49 TOP242-250 TO-262-7C .390 (9.91) .420 (10.67) .055 (1.40) .066 (1.68) .165 (4.17) .185 (4.70) .326 (8.28) .336 (8.53) 7 TYP. .795 (20.18) REF. .080 (2.03) .120 (3.05) .068 (1.73) MIN .024 (.61) .010 (.25) M .034 (.86) .050 (1.27) BSC PIN 1 .150 (3.81) BSC .045 (1.14) .055 (1.40) .495 (12.56) REF. .595 (15.10) REF. PIN 2 & 4 PIN 1 & 7 .040 (1.02) .060 (1.52) .040 (1.06) .060 (1.52) .012 (.30) .024 (.61) .190 (4.83) .210 (5.33) .050 (1.27) .050 (1.27) .050 (1.27) .050 (1.27) .180 (4.58) .200 (5.08) .100 (2.54) PIN 7 PIN 1 .150 (3.81) F07C MOUNTING HOLE PATTERN .150 (3.81) Notes: 1. Controlling dimensions are inches. Millimeter dimensions are shown in parentheses. 2. Pin numbers start with Pin 1, and continue from left to right when viewed from the front. 3. Dimensions do not include mold flash or other protrusions. Mold flash or protrusions shall not exceed .006 (.15mm) on any side. 4. Minimum metal to metal spacing at the package body for omitted pin locations is .068 inch (1.73 mm). 5. Position of terminals to be measured at a location .25 (6.35) below the package body. 6. All terminals are solder plated. PI-2757-122004 50 O 11/05 TOP242-250 Revision Notes Date D - 11/00 E 1) Added R package (D2PAK). 2) Corrected abbreviations (s = seconds). 3) Corrected x-axis units in Figure 11 (A). 4) Added missing external current limit resistor in Figure 25 (RIL). 5) Corrected spelling. 6) Added caption for Table 4. 7) Corrected Breakdown Voltage parameter condition (TJ = 25 C). 8) Corrected font sizes in figures. 9) Figure 40 replaced. 10) Corrected schematic component values in Figure 44. 7/01 F 1) Corrected Power Table value. 9/01 G 1) Added TOP250 device and F package (TO-262). 2) Added R package Thermal Impedance parameters and adjusted Output Power values in Table 1. 3) Adjusted Off-State Current value. 1/02 H 1) Added note to parameter table for Breakdown Voltage measurement. 2) Miscellaneous text corrections. 9/02 I 1) Updated P, Y, R and F package information. 2) Revised thermal impedances (JA) for all package types. 3) Expanded Maximum Duty Cycle and deleted Maximum Duty Cycle Reduction Slope parameters. 4) Corrected DIP-8B and SMD-8B Package Drawings. 4/03 J 1) Added TOP245P. 2) Miscellaneous text corrections. 8/03 K 1) Corrected typographic errors in Figures 4, 6, 20, 28 and 34; and in MULTI-FUNCTION (M) Pin Operation section. 9/03 L 1) Added TOP246P. 3/04 M 1) Added lead-free ordering information. 12/04 N 1) Updated Maximum Duty Cycle conditions. 2) Minor error corrections. 3) Added Note 4 to Absolute Maximum Ratings specification. 4/05 O 1) Added TOP245G and TOP246G 11/05 O 11/05 51 TOP242-250 For the latest updates, visit our website: www.powerint.com Power Integrations reserves the right to make changes to its products at any time to improve reliability or manufacturability. Power Integrations does not assume any liability arising from the use of any device or circuit described herein. POWER INTEGRATIONS MAKES NO WARRANTY HEREIN AND SPECIFICALLY DISCLAIMS ALL WARRANTIES INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD PARTY RIGHTS. PATENT INFORMATION The products and applications illustrated herein (including transformer construction and circuits external to the products) may be covered by one or more U.S. and foreign patents, or potentially by pending U.S. and foreign patent applications assigned to Power Integrations. A complete list of Power Integrations patents may be found at www.powerint.com. Power Integrations grants its customers a license under certain patent rights as set forth at http://www.powerint.com/ip.htm. LIFE SUPPORT POLICY POWER INTEGRATIONS PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF POWER INTEGRATIONS. As used herein: 1. A Life support device or system is one which, (i) is intended for surgical implant into the body, or (ii) supports or sustains life, and (iii) whose failure to perform, when properly used in accordance with instructions for use, can be reasonably expected to result in significant injury or death to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. The PI logo, TOPSwitch, TinySwitch, LinkSwitch, DPA-Switch, EcoSmart, Clampless, E-Shield, Filterfuse, PI Expert and PI FACTS are trademarks of Power Integrations, Inc. Other trademarks are property of their respective companies. (c)Copyright 2005, Power Integrations, Inc. Power Integrations Worldwide Sales Support Locations WORLD HEADQUARTERS 5245 Hellyer Avenue San Jose, CA 95138, USA. Main: +1-408-414-9200 Customer Service: Phone: +1-408-414-9665 Fax: +1-408-414-9765 e-mail: usasales@powerint.com GERMANY Rueckertstrasse 3 D-80336, Munich Germany Phone: +49-89-5527-3910 Fax: +49-89-5527-3920 e-mail: eurosales@powerint.com JAPAN Keihin Tatemono 1st Bldg 2-12-20 Shin-Yokohama, Kohoku-ku, Yokohama-shi, Kanagawa ken, Japan 222-0033 Phone: +81-45-471-1021 Fax: +81-45-471-3717 e-mail: japansales@powerint.com TAIWAN 5F, No. 318, Nei Hu Rd., Sec. 1 Nei Hu Dist. Taipei, Taiwan 114, R.O.C. Phone: +886-2-2659-4570 Fax: +886-2-2659-4550 e-mail: taiwansales@powerint.com CHINA (SHANGHAI) Rm 807-808A Pacheer Commercial Centre, 555 Nanjing Rd. West Shanghai, P.R.C. 200041 Phone: +86-21-6215-5548 Fax: +86-21-6215-2468 e-mail: chinasales@powerint.com INDIA 261/A, Ground Floor 7th Main, 17th Cross, Sadashivanagar Bangalore, India 560080 Phone: +91-80-5113-8020 Fax: +91-80-5113-8023 e-mail: indiasales@powerint.com KOREA RM 602, 6FL Korea City Air Terminal B/D, 159-6 Samsung-Dong, Kangnam-Gu, Seoul, 135-728, Korea Phone: +82-2-2016-6610 Fax: +82-2-2016-6630 e-mail: koreasales@powerint.com EUROPE HQ 1st Floor, St. Jamess House East Street, Farnham Surrey GU9 7TJ United Kingdom Phone: +44 (0) 1252-730-140 Fax: +44 (0) 1252-727-689 e-mail: eurosales@powerint.com CHINA (SHENZHEN) Rm 2206-2207, Block A, Electronics Science & Technology Bldg. 2070 Shennan Zhong Rd. Shenzhen, Guangdong, China, 518031 Phone: +86-755-8379-3243 Fax: +86-755-8379-5828 e-mail: chinasales@powerint.com ITALY Via Vittorio Veneto 12 20091 Bresso MI Italy Phone: +39-028-928-6000 Fax: +39-028-928-6009 e-mail: eurosales@powerint.com SINGAPORE 51 Newton Road #15-08/10 Goldhill Plaza Singapore, 308900 Phone: +65-6358-2160 Fax: +65-6358-2015 e-mail: singaporesales@powerint.com APPLICATIONS HOTLINE World Wide +1-408-414-9660 52 O 11/05 APPLICATIONS FAX World Wide +1-408-414-9760