MOBYR Identification System Four/Eight-Module Rack including Housing and 24 V/10 A Powerpack Technical Description Release 12.96 Description of Four/Eight-Module Rack 6GT2097-3AK00-1EA2 Table of Contents 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Hardware of the Module Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.1 2.2 2.2.1 2.2.2 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 2.3.6 2.3.7 2.3.8 2.4 2.4.1 2.4.2 2.4.2.1 2.4.2.2 2.4.3 2.4.4 2.4.5 2.4.6 2.4.7 2.5 2.5.1 2.5.2 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setup of the Module Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Four-Module Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Eight-Module Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connection of the Plug-In PCB in the Module Rack . . . . . . . . . . . . . . . . . . . . . . . . . TTY Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TTY Daisy Chain Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS 422 (RS 485) Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS 422 (RS 485) Daisy Chain Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V.24 (RS 232) Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . STG Cabling (RS 422) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SINEC L1 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DI/DQ Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Jumper Settings (Parameterization) of the Plug-In PCB in the Module Rack . . . TTY and TTY Daisy Chain Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS 422 and RS 422 Daisy Chain Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Terminated on Receiver Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Terminated on Sender Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V.24 (RS 232) Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . STG Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SINEC L1 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PROFIBUS Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DI/DQ Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connector Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-Way Sub D Plug Connector of the Plug-In PCB . . . . . . . . . . . . . . . . . . . . . . . Terminating Plug Connectors for PROFIBUS Interface . . . . . . . . . . . . . . . . . . . 3 3 4 5 6 6 7 8 9 9 10 10 11 12 12 13 13 14 15 15 16 17 17 18 18 19 3 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack -1- Subject to change without prior notice 12/96 6GT2097-3AK00-1EA2 Description of Four/Eight-Module Rack 1 Features - Modules from the MOBY-I, MOBY-L, and MOBY-V families can be used in this module rack. MOBY-I/-V physical addressing Interface module 420 6GT2002-0CA00 /RS 232 (V.24) Interface module 420 6GT2002-0CB00 /RS 485 Interface module 420 6GT2002-0CC00 /TTY MOBY-I logical addressing Interface module 421 6GT2002-0DA00 /RS 232 (V.24) Interface module 421 6GT2002-0DB00 /RS 485 Interface module 421 6GT2002-0DC00 /TTY MOBY-L physical addressing Interface module 520 6GT2102-0CA00 /RS 232 (V.24) Interface module 520 6GT2102-0CB00 /RS 485 Interface module 520 6GT2102-0CC00 /TTY MOBY-I/-L/-V PROFIBUS-DP Interface module 440 6GT2002-0EA00 /PROFIBUS MOBY-I PROFIBUS-FMS Interface module ASM 441 6GT2002-0EA10 /PROFIBUS - The module rack is available in two models. 6GT2090-0KA00 for 4 modules 6GT2090-0LA00 for 8 modules - Integrated voltage supply: 230 V AC/24 V DC; 10 A - Integrated fan - Internal bus wiring - Plug-in PCB with 4 (or 2 x 4) serial interfaces included - Up to 8 interfaces can be operated. - Several, physically different interfaces can be operated. - Multiplex operation with TTY, RS 485 and PROFIBUS-DP interfaces can be parameterised via plug-in PCB (select/request, SINUMERIK 850/880 protocol and SINEC L1). Subject to change without prior notice 12/96 -2- 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack Description of Four/Eight-Module Rack 6GT2097-3AK00-1EA2 2 Hardware of the Module Rack 2.1 Technical Specifications Casing Dimensions (W x H x T) - Module rack for 4 interfaces 257 x 147 x 315 mm - Module rack for 8 interfaces 364 x 147 x 315 mm Material Steel plate IP rating in accordance with IEC 529 IP 20 Voltage Supply Via integrated powerpack - Primary 230 V AC/50 to 60 Hz - Secondary 24 V DC/10 A Length of the power supply cable Approx. 2.8 m Powerpack Classification - Overvoltage resistance VDE 0160/2 - Safety of EPD systems including electronic office machines VDE 0805, - Interference suppression VDE 0871/B, EN 55022/B EN 60950 Plug-In PCB 4 sub D sockets; for serial interfaces and DI/DQ; connection to PC Connections Ambient Requirements Operating temperature 0 to 55 C Storage temperature -40 to 70 C 2.2 Setup of the Module Rack The plug-in PCB has a fixed slot in the module rack. The plug-in PCB comes already installed in its slot and cannot be changed. The connections (i.e., serial interfaces) of the plug-in PCB are assigned to the slots for the interface modules as shown in the following figures. 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack -3- Subject to change without prior notice 12/96 6GT2097-3AK00-1EA2 Description of Four/Eight-Module Rack 2.2.1 Four-Module Rack View of the front Module rack 3 4 ASM 420/421/440/441/520 ASM 420/421/440/441/520 x 1 x 3 4 x 25-way sub D sockets 2 ASM 420/421/440/441/520 Powerpack (24 V/10 A) 1 ASM 420/421/440/441/520 147 mm Interface modules x 2 x 4 257 mm Plug-in PCB Plug-In Connector Assignment Interface Module Plug-In Connector 1 2 3 4 X1 X2 X3 X4 View of the back Fan 230 V 50/60 Hz Approx. 2.8 m Subject to change without prior notice 12/96 -4- 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack Description of Four/Eight-Module Rack 6GT2097-3AK00-1EA2 2.2.2 Eight-Module Rack Internally, the eight-module rack consists of two four-module racks. When daisy chaining is used, the bus signals are only forwarded via 4 interface modules (e.g., for PROFIBUS cabling). 4 x 1 x 3 4 x 25-way sub D sockets x 4 3 ASM 420/421/440/441/520 ASM 420/421/440/441/520 x 3 x 2 2 ASM 420/421/440/441/520 ASM 420/421/440/441/520 x 1 1 ASM 420/421/440/441/520 4 ASM 420/421/440/441/520 3 4 x 25-way sub D sockets 2 ASM 420/421/440/441/520 Powerpack (24 V/ 10 A) 1 ASM 420/421/440/441/520 147 mm View of the front x 2 x 4 364.1 mm Plug-In Connector Assignment Interface Module Plug-In Connector Interface Module Plug-In Connector 1 2 3 4 X1 X2 X3 X4 1 2 3 4 X1 X2 X3 X4 View of the back Fan Fan 230 V 50/60 Hz Approx. 2.8 m 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack -5- Subject to change without prior notice 12/96 6GT2097-3AK00-1EA2 Description of Four/Eight-Module Rack 2.3 Connection of the Plug-In PCB in the Module Rack 2.3.1 TTY Cabling SLG Module Rack Computer (Active) ASM (Passive) 25-way sub D x1 to x4 X2 1-9 TxD RxD 1 3 2 14 RxD -SE +SE -EM +EM + TxD + Max. length 1000 m SLG Module Rack ASM (Active) Computer (Passive) 25-way sub D x1 to x4 X2 1-9 13 R R TxD RxD 1 3 2 14 25 -SE +SE -EM +EM RxD R TxD R Max. length 1000 m A loop current of 20 to 30 mA requires resistors (R) to be dimensioned with 470 ohm each (P = 0.5 W). Subject to change without prior notice 12/96 -6- 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack Description of Four/Eight-Module Rack 6GT2097-3AK00-1EA2 2.3.2 TTY Daisy Chain Cabling SLG SLG Module Rack Module Rack ASM No. 1 ASM No. 2 SLG Module Rack ....... ASM No. 4 13 4 7 0 +20 mA 2 19 +EM 4 7 0 CP or computer +20mA 4 7 0 1 ....... -SE 4 7 0 25 +SE 17 20 8 Request Dig. inputs Select -EM 20 8 Active 25-way sub D x1 20 8 Passive 25-way sub D x2 Passive 25-way sub D x4 Dig. outputs Passive We recommend that the computer be the active partner of the TTY interface. If this is possible, the resistors shown for ASM no. 1 are omitted. If this is not possible (as shown in the drawing), the active partner of the interface must be supplied with 4 resistors (R = 470 ohm) on the 25-way connector of ASM no. 1. Remember: 6GT2090-0KA00 6GT2090-0LA00 If you use this type of wiring, it is imperative that you install all ASMs consecutively without gaps starting at slot x1. Otherwise, an open, unprotected electrical circuit will be created. In addition, you must set the jumpers on the plug-in PCB. Four-Module Rack Eight-Module Rack -7- Subject to change without prior notice 12/96 6GT2097-3AK00-1EA2 Description of Four/Eight-Module Rack 2.3.3 RS 422 (RS 485) Cabling SLG Computer Module Rack ASM 25-way sub D x1 to x4 X2 1-9 . 7 TxD 15 2 + *) **) ***) D- **) *) . +5V D+ E+ Max. length 1000 m These jumpers are inserted as described in chapter 2.4.2.1. These jumpers are inserted as described in chapter 2.4.2.2. The terminal resistors shown in the diagram must be provided on the computer side. If lines are short, these resistors can be wired on the ASM side. Jumpers z6-z8 and b4-z4 are then omitted, and two jumpers are added (i.e., b4-b6 and z6-b8). Subject to change without prior notice 12/96 ***) ***) 3 RxD E- *) **) -8- 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack Description of Four/Eight-Module Rack 6GT2097-3AK00-1EA2 2.3.4 RS 422 (RS 485) Daisy Chain Cabling SLG SLG Module Rack Module Rack ASM No. 1 ASM No. 2 SLG Module Rack ....... ASM No. 4 CP or computer +E 2 7 -E Enable +5 V Enable Enable ....... *) +D 3 15 -D *) 20 8 20 8 20 8 25-way sub D x1 25-way sub D x2 25-way sub D x4 Request Dig. inputs Select Dig. outputs *) Max. of 1000 m These jumpers are inserted as described in chapter 2.4.2.2. 2.3.5 V.24 (RS 232) Cabling SLG Max Computer Module Rack (ASM) 25-way sub D x1 to x4 X2 1-9 07 RxD RxD TxD 03 02 TxD Ma Max. length 30 m 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack -9- Subject to change without prior notice 12/96 6GT2097-3AK00-1EA2 Description of Four/Eight-Module Rack 2.3.6 STG Cabling (RS 422) SLG Module Rack (ASM) X2 1-9 STG 25-way sub D x1 to x4 24 V 13 9 TxD RxD 0V 07 E- 15 D- 03 02 25 D+ E+ + 1 Max. test cable length 100 m The ASM/RS 422 can be operated directly with the STG via a cable. This tests the entire path from STG via the ASM to the SLG to be tested. 2.3.7 SINEC L1 Cabling The ASM can only be operated on SINEC L1 when RS 422 or TTY is used. Up to 16 ASMs can be connected to one SINEC L1 bus. The SINEC L1 address is set on switch bank S1 on the module. See the "SINEC L1 Bus System" equipment manual (order no: 6ES5998-7LA21) for more details on configuring and programming the SINEC L1 bus. ASM/RS 422 Bus Setup on SINEC L1: Controller computer C P 5 3 0 SINEC L1 master (addr. 0) SLG SLG Module rack Module rack TTY connection (with voltage supply for BT 777) ASM ASM no. 1 no. 2 x1 2 7 3 15 .......... x2 BT 777 0B 1B (bus 2B terminal) 3B 4B RS 422 1000 m (max.) Remember the jumper settings of the plug-in PCB in the module rack. Subject to change without prior notice 12/96 - 10 - 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack Description of Four/Eight-Module Rack 6GT2097-3AK00-1EA2 2.3.8 DI/DQ Cabling Example Module rack 25-way sub D x1 to x4 ASM +24 V Relay, hooter, lamps, or similar Proximity switch 13 ANW 4 16 Error code DI 1 23 DI 0 24 0V 25 Imax = 200 mA (per DQ or total current) Max. cable length 100 m Setting jumper BR9 on the plug-in PCB allows you to switch DI0 and DI1 and DQ0 and DQ1 from interface x1 to interface x2. By parameterising jumper BR10 on the plug-in PCB you can also switch DI0, DI1, DQ0 and DQ1 from interface x4 to interface x3. If the jumpers are inserted, the DIs/DQs of interface x1 and interface x4 can be accessed on interface x2 and interface x3 as shown below. 25-Way Sub D, Interface x2 25-Way Sub D, Interface x3 DQ0 = x1 x2 PIN 17 DQ0 = x4 x3 PIN 17 DQ1 = x1 x2 PIN 6 DQ1 = x4 x3 PIN 6 DI0 = x1 x2 PIN 18 DI0 = x4 x3 PIN 18 DI1 = x1 x2 PIN 7 DI1 = x4 x3 PIN 7 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack - 11 - Subject to change without prior notice 12/96 6GT2097-3AK00-1EA2 Description of Four/Eight-Module Rack 2.4 Jumper Settings (Parameterization) of the Plug-In PCB in the Module Rack 2.4.1 TTY and TTY Daisy Chain Cabling x5 x5 With 4 modules (slots x1 to x4 assigned) BR3 BR8 BR4 BR5 BR1 3rd slot 1st slot 6 5 4 3 2 1 4 3 2 1 4 3 2 1 BR2 x1 BR9 x3 BR10 x2 BR8 BR5 6 5 4 3 2 1 BR6 6 5 4 3 2 1 4 3 2 1 x4 2nd slot 4th slot BR4 BR1 6 5 4 3 2 1 BR7 6 5 4 3 2 1 4 3 2 1 4th slot 6 5 4 3 2 1 4 3 2 1 x4 2nd slot x2 BR2 6 5 4 3 2 1 4 3 2 1 3rd slot BR7 6 5 4 3 2 1 4 3 2 1 1st slot BR3 With 3 modules (slots x1 to x3 assigned) 4 3 2 1 x1 BR9 DO-L1367-1A03 x3 BR10 BR6 DO-L1367-1A03 x5 x5 With 2 modules (slots x1 to x2 assigned) BR3 6 5 4 3 2 1 4 3 2 1 4th slot x4 2nd slot x2 BR7 6 5 4 3 2 1 4 3 2 1 x2 6 5 4 3 2 1 4 3 2 1 x4 4th slot BR7 6 5 4 3 2 1 4 3 2 1 2nd slot BR3 With 1 module (slot x1 assigned) BR4 BR8 BR4 BR8 BR1 BR5 BR1 BR5 4 3 2 1 BR2 BR9 x1 x3 BR10 BR6 BR2 DO-L1367-1A03 Subject to change without prior notice 12/96 6 5 4 3 2 1 4 3 2 1 3rd slot 6 5 4 3 2 1 1st slot 6 5 4 3 2 1 4 3 2 1 3rd slot 1st slot 6 5 4 3 2 1 4 3 2 1 BR9 x1 x3 BR10 BR6 DO-L1367-1A03 - 12 - 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack Description of Four/Eight-Module Rack 6GT2097-3AK00-1EA2 2.4.2 RS 422 and RS 422 Daisy Chain Cabling 2.4.2.1 Terminated on Receiver Side x5 x5 With 3 modules (slots x1 to x3 assigned) With 4 modules (slots x1 to x4 assigned) BR7 4th slot BR7 BR3 6 5 4 3 2 1 4 3 2 1 x4 2nd slot x2 6 5 4 3 2 1 4 3 2 1 x2 6 5 4 3 2 1 4 3 2 1 x4 4th slot 6 5 4 3 2 1 4 3 2 1 2nd slot BR3 BR4 BR8 BR4 BR8 BR1 BR5 BR1 BR5 4 3 2 1 BR2 x1 BR9 x3 BR10 6 5 4 3 2 1 4 3 2 1 3rd slot 6 5 4 3 2 1 1st slot 6 5 4 3 2 1 4 3 2 1 3rd slot 1st slot 6 5 4 3 2 1 4 3 2 1 BR6 BR2 x1 BR9 DO-L1367-1A03 x3 BR10 BR6 DO-L1367-1A03 x5 x5 With 2 modules (slots x1 to x2 assigned) With 1 module (slot x1 assigned) BR7 4th slot BR7 BR3 6 5 4 3 2 1 4 3 2 1 x4 2nd slot x2 6 5 4 3 2 1 4 3 2 1 x2 6 5 4 3 2 1 4 3 2 1 x4 4th slot 6 5 4 3 2 1 4 3 2 1 2nd slot BR3 BR4 BR8 BR4 BR8 BR1 BR5 BR1 BR5 4 3 2 1 BR2 x1 BR9 x3 BR10 4 3 2 1 BR6 BR2 DO-L1367-1A03 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack 6 5 4 3 2 1 4 3 2 1 3rd slot 6 5 4 3 2 1 1st slot 6 5 4 3 2 1 4 3 2 1 3rd slot 1st slot 6 5 4 3 2 1 BR9 x1 x3 BR10 BR6 DO-L1367-1A03 - 13 - Subject to change without prior notice 12/96 6GT2097-3AK00-1EA2 Description of Four/Eight-Module Rack 2.4.2.2 Terminated on Sender Side x5 x5 With 3 modules (slots x1 to x3 assigned) With 4 modules (slots x1 to x4 assigned) BR7 BR1 BR2 3rd slot 1st slot x1 BR9 x3 BR10 4th slot BR8 BR1 6 5 4 3 2 1 4 3 2 1 4 3 2 1 6 5 4 3 2 1 4 3 2 1 x4 BR4 BR5 6 5 4 3 2 1 x2 BR5 6 5 4 3 2 1 6 5 4 3 2 1 4 3 2 1 3rd slot 4th slot 6 5 4 3 2 1 4 3 2 1 BR8 BR4 BR7 BR3 6 5 4 3 2 1 4 3 2 1 x4 2nd slot x2 2nd slot 6 5 4 3 2 1 4 3 2 1 1st slot BR3 4 3 2 1 BR6 BR2 x1 BR9 DO-L1367-1A03 x3 BR10 BR6 DO-L1367-1A03 x5 x5 With 2 modules (slots x1 to x2 assigned) With 1 module (slot x1 assigned) BR7 BR7 BR3 6 5 4 3 2 1 4 3 2 1 x4 4th slot 2nd slot x2 6 5 4 3 2 1 4 3 2 1 x2 6 5 4 3 2 1 4 3 2 1 x4 4th slot 6 5 4 3 2 1 4 3 2 1 2nd slot BR3 BR4 BR8 BR4 BR8 BR1 BR5 BR1 BR5 4 3 2 1 BR2 BR9 x1 x3 BR10 4 3 2 1 BR6 BR2 DO-L1367-1A03 Subject to change without prior notice 12/96 6 5 4 3 2 1 4 3 2 1 3rd slot 6 5 4 3 2 1 1st slot 6 5 4 3 2 1 4 3 2 1 3rd slot 1st slot 6 5 4 3 2 1 BR9 x1 x3 BR10 BR6 DO-L1367-1A03 - 14 - 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack Description of Four/Eight-Module Rack 6GT2097-3AK00-1EA2 2.4.3 V.24 (RS 232) Cabling x5 BR7 BR3 6 5 4 3 2 1 4 3 2 1 6 5 4 3 2 1 4 3 2 1 4th slot x4 2nd slot x2 BR8 BR4 BR1 BR5 6 5 4 3 2 1 4 3 2 1 3rd slot 1st slot 6 5 4 3 2 1 4 3 2 1 BR2 x1 BR9 x3 BR10 BR6 DO-L1367-1A03 2.4.4 STG Cabling x5 With 1 to 4 modules Insert the jumpers as for BR1 for every module used. BR7 BR3 6 5 4 3 2 1 4 3 2 1 6 5 4 3 2 1 4 3 2 1 4th slot x4 2nd slot x2 BR8 BR4 BR1 BR5 6 5 4 3 2 1 4 3 2 1 3rd slot 1st slot 6 5 4 3 2 1 4 3 2 1 BR2 x1 BR9 x3 BR10 BR6 DO-L1367-1A03 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack - 15 - Subject to change without prior notice 12/96 6GT2097-3AK00-1EA2 Description of Four/Eight-Module Rack 2.4.5 SINEC L1 Cabling x5 x5 With 3 modules (slots x1 to x3 assigned) With 4 modules (slots x1 to x4 assigned) BR7 BR1 BR2 3rd slot 1st slot x1 BR9 x3 BR10 4th slot BR8 BR1 6 5 4 3 2 1 4 3 2 1 4 3 2 1 6 5 4 3 2 1 4 3 2 1 x4 BR4 BR5 6 5 4 3 2 1 x2 BR5 6 5 4 3 2 1 6 5 4 3 2 1 4 3 2 1 3rd slot 4th slot 6 5 4 3 2 1 4 3 2 1 BR8 BR4 BR7 BR3 6 5 4 3 2 1 4 3 2 1 x4 2nd slot x2 2nd slot 6 5 4 3 2 1 4 3 2 1 1st slot BR3 4 3 2 1 BR6 BR2 x1 BR9 DO-L1367-1A03 x3 BR10 BR6 DO-L1367-1A03 x5 x5 With 2 modules (slots x1 to x2 assigned) With 1 module (slot x1 assigned) BR7 BR7 4th slot 6 5 4 3 2 1 4 3 2 1 x2 6 5 4 3 2 1 4 3 2 1 x4 4th slot 6 5 4 3 2 1 4 3 2 1 x4 2nd slot x2 2nd slot 6 5 4 3 2 1 4 3 2 1 BR4 BR8 BR4 BR8 BR1 BR5 BR1 BR5 4 3 2 1 BR2 BR9 x1 x3 BR10 4 3 2 1 BR6 BR2 DO-L1367-1A03 Subject to change without prior notice 12/96 6 5 4 3 2 1 4 3 2 1 3rd slot 6 5 4 3 2 1 1st slot 6 5 4 3 2 1 4 3 2 1 3rd slot 1st slot 6 5 4 3 2 1 BR9 x1 x3 BR10 BR6 DO-L1367-1A03 - 16 - 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack Description of Four/Eight-Module Rack 6GT2097-3AK00-1EA2 2.4.6 PROFIBUS Cabling x5 With 1 to 4 modules A terminating plug connector must be installed in the last slot used (! section 2.5.2). BR7 BR3 6 5 4 3 2 1 4 3 2 1 6 5 4 3 2 1 4 3 2 1 4th slot x4 2nd slot x2 BR8 BR4 BR1 BR5 6 5 4 3 2 1 4 3 2 1 3rd slot 1st slot 6 5 4 3 2 1 4 3 2 1 BR2 x1 BR9 x3 BR10 BR6 DO-L1367-1A03 2.4.7 DI/DQ Cabling x5 When DI/DQ are to be rerouted from slot x1 to slot x2 When DI/DQ are to be rerouted from slot x4 to slot x3 BR7 6 5 4 3 2 1 4 3 2 1 4th slot BR7 BR3 6 5 4 3 2 1 4 3 2 1 x4 2nd slot x2 6 5 4 3 2 1 4 3 2 1 x2 6 5 4 3 2 1 4 3 2 1 x4 4th slot BR3 2nd slot x5 BR4 BR8 BR4 BR8 BR1 BR5 BR1 BR5 4 3 2 1 BR2 x1 BR9 x3 BR10 4 3 2 1 BR6 BR2 DO-L1367-1A03 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack 6 5 4 3 2 1 4 3 2 1 3rd slot 6 5 4 3 2 1 1st slot 6 5 4 3 2 1 4 3 2 1 3rd slot 1st slot 6 5 4 3 2 1 BR9 x1 x3 BR10 BR6 DO-L1367-1A03 - 17 - Subject to change without prior notice 12/96 6GT2097-3AK00-1EA2 Description of Four/Eight-Module Rack 2.5 Connector Assignment 2.5.1 25-Way Sub D Plug Connector of the Plug-In PCB Sub D Connector Pin ASM Connector Pin 1 z6 2 z4 3 b6 4 z 18 With DI/DQ Rerouting (J mpers (Jumpers 9 + 10) Connector x2/x3 5 DQ1 x1/x4 6 DI1 x1/x4 7 z8 8 z 16 Signal Description for Differing Configuration RS 422 TTY TTY Daisy Chain PROFIBUS R- - SE -SE 5V TxD E+ - EM -EM RxD D+ + SE ANW ANW ANW GND E- V.24 Select ANW ANW M5 Select Resetausgang Select 9 z 26 DQ3 10 b 26 DQ2 11 z 14 DQ1 DQ1 DQ1 DQ1 DQ1 12 b 14 DQ0 DQ0 DQ0 DQ0 DQ0 13 z2 +24 V +24 V +24 V +24 V +24 V 14 b4 R+ +EM 15 b8 16 b 18 RTS DError code 17 DQ0 x1/x4 18 DI0 x1/x4 Error code A line Error code Error code Error code +SE 19 +EM 20 b 16 21 z 24 DI3 22 b 24 DI2 23 z 12 DI1 DI1 DI1 DI1 DI1 24 b 12 DI0 DI0 DI0 DI0 DI0 25 b 2/b 32 0V 0V 0V 0V 0V Subject to change without prior notice 12/96 B line Request - 18 - Request Request 6GT2090-0KA00 6GT2090-0LA00 Reset input Four-Module Rack Eight-Module Rack Description of Four/Eight-Module Rack 6GT2097-3AK00-1EA2 2.5.2 Terminating Plug Connectors for PROFIBUS Interface Sub D Connector Pin Signal 1 5V Cable Single Wire 0.14 mm R1 390 W 3 B line R2 220 W 15 A line R3 390 W 7 M5 This terminating connector can be made by the user. It must be installed on plug connector X4 on the last PROFIBUS module rack. 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack - 19 - Subject to change without prior notice 12/96 6GT2097-3AK00-1EA2 Description of Four/Eight-Module Rack 3 Warnings Subject to change without prior notice 12/96 - 20 - 6GT2090-0KA00 6GT2090-0LA00 Four-Module Rack Eight-Module Rack Siemens AG Automation Technology Combination Technology Identification Technology P.O. Box 2355, 90713 Fuerth Siemens Aktiengesellschaft Subject to change without prior notice Order No: 6GT2097-3AK00-1EA2 Printed in the Fed. Rep. of Germany