2015-12-07 1
2015-1 2-07
SOLERIQ® S 19
Datasheet
Version 1.2
GW KAHNB1.EM
The SOLERIQ® S products were specifically designed
for applications requiring large flux packages out of a
compact area.
Die SOLERIQ® S Produkte wurden speziell für
Anwendungen entwickelt, die großen Lichtstrom aus
einer kompakten Fläche benötigen.
Features: Besondere Merkmale:
Package: Chip-on-Board Gehäusetyp: Chip-on-Board
Viewing angle at 50 % IV: 12 Abstrahlwinkel bei 50 % IV: 12
Color: 2700 K - 4000 K (white) Farbe: 2700 K - 4000 K (weiß)
CRI: min. 80 ( typ. 82 ) CRI: min. 80 ( typ. 82 )
Luminous Flux: typ. 5478 lm @ 4000 K, 85 °C Lichtstrom: typ. 5478 lm @ 4000 K, 85 °C
Luminous efficacy: typ. 121 lm/W @ 4000 K,
85 °C
Lichtausbeute: typ. 121 lm/W @ 4000 K, 85 °C
Applications Anwendungen
Spot lights Spot-Leuchten
Indoor General Lighting Innen-Allgemeinbeleuchtung
2015-12-07 2
Version 1.2 GW KAHNB1.EM
Ordering Information
Bestellinformation
Type: Color
Temperature
Luminous Flux
1) page 17 Ordering Code
Typ: Farbtemperatur Lichtstrom
1) Seite 17 Bestellnummer
IF = 1050 mA,
TS = 85 °C
[K] ΦV [lm]
GW KAHNB1.EM-UPUQ-27S3 2700 4500 ... 5200 Q65111A7453
GW KAHNB1.EM-UPUQ-30S3 3000 4500 ... 5200 Q65111A7452
GW KAHNB1.EM-UQUR-30S3 3000 4840 ... 5630 Q65111A7451
GW KAHNB1.EM-UQUR-35S3 3500 4840 ... 5630 Q65111A7450
GW KAHNB1.EM-URUS-35S3 3500 5200 ... 6100 Q65111A7448
GW KAHNB1.EM-URUS-40S3 4000 5200 ... 6100 Q65111A7447
Note: The above Type Numbers represent the order groups which include only a few brightness groups (see page 5). Only one group will
be shipped on each packing unit (there will be no mixing of two groups on each packing unit). E. g. GW KAHNB1.EM-UPUQ-30S3
means that only one group UP, UQ will be shippable for any packing unit.
Anm.: Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen
(siehe Seite 5). Es wird nur eine einzige Helligkeitsgruppe pro Verpackungseinheit geliefert. Z. B. GW KAHNB1.EM-UPUQ-30S3
bedeutet, dass in einer Verpackungseinheit nur eine der Helligkeitsgruppen UP, UQ enhalten ist.
Version 1.2 GW KAHNB1.EM
2015-12-07 3
Maximum Ratings
Grenzwerte
Parameter Symbol Values Unit
Bezeichnung Symbol Werte Einheit
Operating temperature range
Betriebstemperatur
Top -30 ... 105 °C
Storage temperature range
Lagertemperatur
Tstg -40 ... 100 °C
Junction temperature
Sperrschichttemperatur
Tj125 °C
Forward current
Durchlassstrom
(TS = 85 °C)
IF1400 mA
Surge current
Stoßstrom
(t ≤ 10 µs; D = 0.005; TS = 85 °C)
IFM 1680 mA
Reverse current
Sperrstrom IR20 mA
ESD withstand voltage
ESD Festigkeit
(acc. to ANSI/ESDA/JEDEC JS-001 - HBM, Class 2)
VESD 2 kV
2015-12-07 4
Version 1.2 GW KAHNB1.EM
Characteristics (TS = 85 °C; IF = 1050 mA)
Kennwerte
Parameter Symbol Values Unit
Bezeichnung Symbol Werte Einheit
Viewing angle at 50 % IV
Abstrahlwinkel bei 50 % IV
(typ.) 120 °
Forward voltage 2) page 17
Durchlassspannung 2) Seite 17 (min.)
(typ.)
(max.)
VF
VF
VF
40.0
43.2
47.0
V
V
V
Reverse voltage
Sperrspannung
(IR = 20 mA)
(max.) VR1.2 V
Color rendering index 3) page 17
Farbwiedergabe Index 3) Seite 17 (typ.)
(min.)
Ra
Ra
82
80
-
-
Real thermal resistance junction / solder point
4) page 17
Realer Wärmewiderstand Sperrschicht / Lötpad
4) Seite 17
(typ.)
(max.)
Rth JS real
Rth JS real
0.5
0.6
K/W
K/W
"Electrical" thermal resistance junction / solder point
4) page 17
"Elektrischer" Wärmewiderstand Sperrschicht /
Lötpad 4) Seite 17
(with efficiency ηe = 35 %)
(typ.)
(max.)
Rth JS el
Rth JS el
0.3
0.4
K/W
K/W
Version 1.2 GW KAHNB1.EM
2015-12-07 5
Brightness Groups
Helligkeitsgruppen
Group Luminous Flux
1) page 17 Luminous Flux
1) page 17 Luminous Flux
5) page 17 Luminous Flux
5) page 17
Gruppe Lichtstrom
1) Seite 17 Lichtstrom
1) Seite 17 Lichtstrom
5) Seite 17 Lichtstrom
5) Seite 17
TS = 85 °C TS = 85 °C TS = 25 °C TS = 25 °C
(min.) ΦV [lm] (max.) ΦV [lm] (extrapolated min.)
ΦV [lm]
(extrapolated max.)
ΦV [lm]
TU 4190 4500 4690 5040
UP 4500 4840 5040 5420
UQ 4840 5200 5420 5820
UR 5200 5630 5820 6310
US 5630 6100 6310 6830
Note: The standard shipping format for serial types includes either a lower family group, an upper family group
or a grouping of all individual brightness groups of only a few brightness groups. Individual brightness
groups cannot be ordered.
Anm.: Die Standardlieferform von Serientypen beinhaltet entweder eine untere Familiengruppe, eine obere
Familiengruppe oder eine Sammelgruppe, die aus nur wenigen Helligkeitsgruppen besteht. Einzelne
Helligkeitsgruppen sind nicht bestellbar.
2015-12-07 6
Version 1.2 GW KAHNB1.EM
Color Chromaticity Groups 6) page 17
Farbortgruppen 6) Seite 17
Chromaticity Coordinate Groups 6) page 17
Farbortgruppen 6) Seite 17
Group Cx Cy a b Θ
40S3 0.3823 0.3790 0.0094 0.0040 53
35S3 0.4077 0.3908 0.0093 0.0041 53
30S3 0.4339 0.4020 0.0085 0.0041 53
27S3 0.4578 0.4092 0.0079 0.0041 54
Cx and Cy are the center coordinates of the ellipse, a the length of the major axis, b the length of the minor axis and Θ the angle of
the major axis as defined in IEC 60081.
Cx und Cy sind die Mittelpunktkoordinaten der Ellipse, a die Länge der Hauptachse, b die Länge der Nebenachse und Θ der Winkel
der Hauptachse wie in IEC 60081 definiert.
Version 1.2 GW KAHNB1.EM
2015-12-07 7
Group Name on Label
Gruppenbezeichnung auf Etikett
Example: TU-30S3
Beispiel: TU-30S3
Brightness
Helligkeit
Chromaticity Coordinate
Farbort
TU 30S3
Note: No packing unit / tape ever contains more than one group for each selection.
Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten.
2015-12-07 8
Version 1.2 GW KAHNB1.EM
Relative Spectral Emission - V(λ) = Standard eye response curve 7) page 18
Relative spektrale Emission - V(λ) = spektrale Augenempfindlichkeit 7) Seite 18
Φrel = f (λ); TS = 85 °C; IF = 1050 mA
Radiation Characteristics 7) page 18
Abstrahlcharakteristik 7) Seite 18
Irel = f (ϕ); TS = 85 °C
GW KAHNB1.EM
350 400 450 500 550 600 650 700 750 800
λ
[
nm
]
0.0
0.2
0.4
0.6
0.8
1.0
I
rel
: white
: V
λ
0
0.2
0.4
1.0
0.8
0.6
ϕ
1.0 0.8 0.6 0.4
10˚20˚40˚ 30˚ OHL01660
50˚
60˚
70˚
80˚
90˚
100˚ 20˚ 40˚ 60˚ 80˚ 100˚ 120˚
Version 1.2 GW KAHNB1.EM
2015-12-07 9
Forward Current 7) page 18 , 8) page 18
Durchlassstrom 7) Seite 18 , 8) Seite 18
IF = f (VF); TS = 85 °C
Relative Luminous Flux 7) page 18 , 8) page 18
Relativer Lichtstrom 7) Seite 18 , 8) Seite 18
ΦVV(1050 mA) = f(IF); TS = 85 °C
Chromaticity Coordinate Shift 7) page 18
Farbortverschiebung 7) Seite 18
Cx, Cy = f(IF); TS = 85 °C
GW KAHNB1.EM
36 38 40 42 44 46 48
V
F
[V]
0
200
400
600
800
1000
1200
1400
I
F
[mA]
GW KAHNB1.EM
0
200
400
600
800
1000
1200
1400
I
F
[
mA
]
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
Φ
V
Φ
V
(1050
mA
)
GW KAHNB1.EM
0
200
400
600
800
1000
1200
1400
I
F
[
mA
]
0.40
0.41
0.42
0.43
0.44
Cx
Cy
: Cx
: Cy
2015-12-07 10
Version 1.2 GW KAHNB1.EM
Relative Forward Voltage 7) page 18
Relative Vorwärtsspannung 7) Seite 18
ΔVF = VF - VF(85 °C) = f(Tj); IF = 1050 mA
Relative Luminous Flux 7) page 18
Relativer Lichtstrom 7) Seite 18
ΦVV(85 °C) = f(Tj); IF = 1050 mA
Chromaticity Coordinate Shift 7) page 18
Farbortverschiebung 7) Seite 18
Cx, Cy = f(Tj); IF = 1050 mA
GW KAHNB1.EM
-40 -20 0 20 40 60 80 100 120
T
j
[°C]
0
1
2
3
4
V
F
[V]
GW KAHNB1.EM
-40 -20 0 20 40 60 80 100 120
T
j
[°C]
0,0
0,2
0,4
0,6
0,8
1,0
1,2
1,4
Φ
v
Φ
v
(85°C)
GW KAHNB1.EM
-40 -20 0 20 40 60 80 100 120
T
j
[
°C
]
0.40
0.41
0.42
0.43
0.44
Cx
Cy
: Cx
: Cy
Version 1.2 GW KAHNB1.EM
2015-12-07 11
Max. Permissible Forward Current
Max. zulässiger Durchlassstrom
IF = f (T)
GW KAHNB1.EM
0 20 40 60 80 100 120
T [
°C
]
0
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
I
F
[
A
]
Do not use below 210 mA
: T
s
2015-12-07 12
Version 1.2 GW KAHNB1.EM
Package Outline 9) page 18
Maßzeichnung 9) Seite 18
Approximate Weight: 1.4 g
Gewicht: 1.4 g
ESD information: LED is protected by ESD device which is
connected in parallel to LED-Chip.
ESD Information: Die LED enthält ein ESD-Bauteil, das parallel zum
Chip geschaltet ist.
Version 1.2 GW KAHNB1.EM
2015-12-07 13
Barcode-Product-Label (BPL)
Barcode-Produkt-Etikett (BPL)
Note:
Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card.
Regarding dry pack you will find further information in the internet and in the Short Form Catalog in chapter “Tape and Reel” under the topic “Dry
Pack”. Here you will also find the normative references like JEDEC.
Anm.:
Feuchteempfindliche Produkte sind verpackt in einem Trockenbeutel zusammen mit einem Trockenmittel und einer Feuchteindikatorkarte.
Bezüglich Trockenverpackung finden Sie weitere Hinweise im Internet und in unserem Short Form Catalog im Kapitel “Gurtung und Verpackung
unter dem Punkt “Trockenverpackung”. Hier sind Normenbezüge, unter anderem ein Auszug der JEDEC-Norm, enthalten.
Tray
Bauteilträger
Min. 40 pcs. per packing unit (20 units per tray, min. 2 trays per vacuum bag) / 20 Teile pro Bauteilträger,
2 Bauteilträger pro Vakuumverpackung
OHA04563
(G) GROUP:
1234567890(1T) LOT NO: (9D) D/C: 1234
(X) PROD NO: 123456789
(6P) BATCH NO: 1234567890
LX XXXX
RoHS Compliant
BIN1: XX-XX-X-XXX-X
ML
XTemp ST
XXX °C X
Pack: RXX
DEMY XXX
X_X123_1234.1234 X
9999(Q)QTY:
Semiconductors
OSRAM Opto
XX-XX-X-X
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
XXXXXX
X_X123_1234.1234 XX_X123_1234.1234 X
XX-XX-X-XXX-XX-X-X
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
XXXXXX
X_X123_1234.1234 XX_X123_1234.1234 X
XX-XX-X-XXX-XX-X-X
EXAMPLE
Pack: RXX
XXX
X_X123_1234.1234 XX_X123_1234.1234 X
XX-XX-X-X
EXAMPLE
Pack: RXXPack: RXX
DEMY DEMY
EXAMPLE
1234
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
(9D) D/C:(9D) D/C:
12341234
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
1234
1234
EXAMPLE
Pack: RXXPack: RXX
DEMY
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
(9D) D/C:(9D) D/C:
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
(9D) D/C:
1234
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
(9D) D/C:
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
12345678901234567890
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
(6P) BATCH NO:(6P) BATCH NO:
12345678901234567890
SemiconductorsSemiconductors
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE
(6P) BATCH NO:(6P) BATCH NO:
12345678901234567890
EXAMPLE
SemiconductorsSemiconductors
OSRAM OptoOSRAM Opto
EXAMPLE
EXAMPLE
1234567890
X_X123_1234.1234 X
Pack: RXX
DEMY
X_X123_1234.1234 X
(9D) D/C:
1234
(9D) D/C:
1234567890
(6P) BATCH NO:
1234567890
OSRAM Opto
XXX
X_X123_1234.1234 X
XX-XX-X-X
Pack: RXX
DEMY
Semiconductors
2015-12-07 14
Version 1.2 GW KAHNB1.EM
Transportation Packing and Materials
Kartonverpackung und Materialien
Dimensions of transportation box in mm
Width Length Height
Breite Länge Höhe
333 ± 5 218 ± 5 28 ± 5
OHA02886
PACKVAR:
R077
Additional TEXT
P-1+Q-1
Multi TOPLED
Muster
OSRAM Opto
Semiconductors
(6P) BATCH NO:
(X) PROD NO:
1
0
(9D) D/C:
11
(1T) LOT NO:
210021998
123GH1234
02
45
(Q)QTY:2000
0144
(G) GROUP:
260 C RT
240 C R
3
220 C R
ML
Bin3:
Bin2: Q-1-20
Bin1: P-1-20
LSY T676
2
2a
Temp ST
R18DEMY
Barcode label
Original packing label
Box
Version 1.2 GW KAHNB1.EM
2015-12-07 15
Notes Hinweise
The evaluation of eye safety occurs according to the
standard IEC 62471:2008 ("photobiological safety of
lamps and lamp systems"). Within the risk grouping
system of this CIE standard, the LED specified in this
data sheet fall into the class Low risk (exposure time
100 s). Under real circumstances (for exposure time,
eye pupils, observation distance), it is assumed that
no endangerment to the eye exists from these
devices. As a matter of principle, however, it should
be mentioned that intense light sources have a high
secondary exposure potential due to their blinding
effect. As is also true when viewing other bright light
sources (e.g. spotlights), temporary reduction in
visual acuity and afterimages can occur, leading to
irritation, annoyance, visual impairment, and even
accidents, depending on the situation.
Die Bewertung der Augensicherheit erfolgt nach
dem Standard IEC 62471:2008 ("photobiological
safety of lamps and lamp systems"). Im
Risikogruppensystem dieser CIE- Norm erfüllen die
in diesem Datenblatt angegebenen LEDs folgende
Gruppenanforderung - Low risk (Expositionsdauer
100 s). Unter realen Umständen (für
Expositionsdauer, Augenpupille,
Betrachtungsabstand) geht damit von diesen
Bauelementen keinerlei Augengefährdung aus.
Grundsätzlich sollte jedoch erwähnt werden, dass
intensive Lichtquellen durch ihre Blendwirkung ein
hohes sekundäres Gefahrenpotenzial besitzen.
Nach einem Blick in eine helle Lichtquelle (z.B.
Spotlights), kann ein temporär eingeschränktes
Sehvermögen oder auch Nachbilder zu Irritationen,
Belästigungen, Beeinträchtigungen oder sogar
Unfällen führen.
This LED contains metal materials. Corroded metal
may lead to a worsening of the optical performance
of the LED and can in the worst case lead to a failure
of the LED. Do not expose this LED to aggressive
atmospheres. Note, that corrosive gases may as well
be emitted from materials close to the LED in the final
product.
Diese LED enthält teilweise metallische
Bestandteile. Korrodiertes Metall kann zu einer
Verschlechterung der optischen Eigenschaften und
im schlimmsten Fall zum Ausfall der LED führen.
Diese LED darf aggressiven Bedingungen nicht
ausgesetzt werden. Es ist zu beachten, dass
korrosive Gase auch von Materialien emittiert
werden können, die sich im Endprodukt in
unmittelbarer Umgebung der LED befinden.
This LED is designed for specific/recommended
applications only. Please consult OSRAM Opto
Semiconductors Sales Staff in advance for detailed
information on other non-recommended applications
(e.g. automotive)
OR
Please visit www.osram-os.com/appnotes.
Change management for this component is aligned
with the requirements of the lighting market.
Die LED ist ausschließlich r spezifisch empfohlene
Anwendungen konzipiert. Bitte kontaktieren Sie das
OSRAM Opto Semiconductors Vertriebspersonal r
detailierte Informationen über nicht empfohlene
Anwendungsbereiche (z.B. Automobilbereich). oder
besuchen Sie
www.osram-os.com/appnotes
Das Änderungsmanagement dieses Bauteils ist an
den Anforderungen des Lichtmarktes ausgerichtet.
2015-12-07 16
Version 1.2 GW KAHNB1.EM
Disclaimer Disclaimer
Language english will prevail in case of any
discrepancies or deviations between the two language
wordings.
Attention please!
The information describes the type of component and
shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved.
Due to technical requirements components may
contain dangerous substances.
For information on the types in question please contact
our Sales Organization.
If printed or downloaded, please find the latest version
in the Internet.
Packing
Please use the recycling operators known to you. We
can also help you – get in touch with your nearest sales
office.
By agreement we will take packing material back, if it is
sorted. You must bear the costs of transport. For
packing material that is returned to us unsorted or which
we are not obliged to accept, we shall have to invoice
you for any costs incurred.
Components used in life-support devices or
systems must be expressly authorized for such
purpose!
Critical components* may only be used in life-support
devices** or systems with the express written approval
of OSRAM OS.
*) A critical component is a component used in a
life-support device or system whose failure can
reasonably be expected to cause the failure of that
life-support device or system, or to affect its safety or
the effectiveness of that device or system.
**) Life support devices or systems are intended (a) to
be implanted in the human body, or (b) to support
and/or maintain and sustain human life. If they fail, it is
reasonable to assume that the health and the life of the
user may be endangered.
Bei abweichenden Angaben im zweisprachigen
Wortlaut haben die Angaben in englischer Sprache
Vorrang.
Bitte beachten!
Lieferbedingungen und Änderungen im Design
vorbehalten. Aufgrund technischer Anforderungen
können die Bauteile Gefahrstoffe enthalten. Für weitere
Informationen zu gewünschten Bauteilen, wenden Sie
sich bitte an unseren Vertrieb. Falls Sie dieses
Datenblatt ausgedruckt oder heruntergeladen haben,
finden Sie die aktuellste Version im Internet.
Verpackung
Benutzen Sie bitte die Ihnen bekannten
Recyclingwege. Wenn diese nicht bekannt sein sollten,
wenden Sie sich bitte an das chstgelegene
Vertriebsbüro. Wir nehmen das Verpackungsmaterial
zurück, falls dies vereinbart wurde und das Material
sortiert ist. Sie tragen die Transportkosten. Für
Verpackungsmaterial, das unsortiert an uns
zurückgeschickt wird oder das wir nicht annehmen
müssen, stellen wir Ihnen die anfallenden Kosten in
Rechnung.
Bauteile, die in lebenserhaltenden Apparaten und
Systemen eingesetzt werden, müssen r diese
Zwecke ausdrücklich zugelassen sein!
Kritische Bauteile* dürfen in lebenserhaltenden
Apparaten und Systemen** nur dann eingesetzt
werden, wenn ein schriftliches Einverständnis von
OSRAM OS vorliegt.
*) Ein kritisches Bauteil ist ein Bauteil, das in
lebenserhaltenden Apparaten oder Systemen
eingesetzt wird und dessen Defekt voraussichtlich zu
einer Fehlfunktion dieses lebenserhaltenden
Apparates oder Systems führen wird oder die
Sicherheit oder Effektivität dieses Apparates oder
Systems beeinträchtigt.
**) Lebenserhaltende Apparate oder Systeme sind für
(a) die Implantierung in den menschlichen Körper oder
(b) für die Lebenserhaltung bestimmt. Falls Sie
versagen, kann davon ausgegangen werden, dass die
Gesundheit und das Leben des Patienten in Gefahr ist.
Version 1.2 GW KAHNB1.EM
Published by OSRAM Opto Semiconductors GmbH
Leibnizstraße 4, D-93055 Regensburg
www.osram-os.com © All Rights Reserved.
2015-12-07 18