Panel Mount Datasheet GN Series AC Output SSRs * Current rating 10 and 125 Amps * Output voltage 24-280 VAC and 48-660 VAC * Available with or without IP20 touch-safe cover * LED Input Status Indicator * UL Approved, CE Compliant to EN60950-1 * Improved SEMS screw and washer * Redesigned housing with anti-rotation barriers * EMC Compliant to level 3 For Generation 3 datasheet click here PRODUCT SELECTION Control Voltage 3-32 VDC 18-36 VAC 90-280 VAC 10 A 25 A 50 A 75 A 100 A 125 A 84134000 84134002 84134001 84134010 84134012 84134011 84134020 84134022 84134021 84134030 84134032 84134031 84134040 84134042 84134041 84134080 84134082 84134081 Operating Voltage 0: 24-280 VAC/Zero Voltage Turn-On 1: 48-660 VAC/Zero Voltage Turn-On 2: 24-280 VAC/Instantaneous Turn-On 3: 48-660 VAC/Instantaneous Turn-On AVAILABLE OPTIONS Thermal Pad Blank: Not included H: Included Series 8413 Required for valid part number For options only and not required for valid part number 4 0 Touch Safe Cover 4: Not included (IP00) 7: Included (IP20) > Not all part number combinations are available. Contact Crydom Technical Support for information on the availability of a specific part number. U 0 1 Rated Load Current 0: 10 Amps 1: 25 Amps 2: 50 Amps 3: 75 Amps 4: 100 Amps 8: 125 Amps H Control Voltage 0: 3-32 VDC 1: 90-280 VAC 2: 18-36 VAC OUTPUT SPECIFICATIONS (1) Description Operating Voltage (47-440Hz) [Vrms] Transient Voltage [Vpk] (2) Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/sec] 280 VAC 660 VAC 24-280 600 0.1 500 48-660 1200 0.25 500 OUTPUT SPECIFICATIONS (1) Description Maximum Load Current [Arms] (3) Minimum Load Current [mArms] Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 1 Second surge current (Apk. Ta=25C) 50/60 Hz Maximum On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case (Rjc) [C/W] Maximum 1/2 Cycle I t for Fusing (50/60Hz) [A sec] Minimum Heat Sink for Rated Current @ 40C [C/W] 10 A 25 A 50 A 75 A 100 A 125 A 10 500 150/175 50 1.35 0.4 110/120 5 25 50 275/300 85 1.35 0.4 380/370 2 50 100 710/750 150 1.35 0.25 2520/2320 1 75 100 1050/1100 225 1.3 0.16 5500/5000 0.7 100 100 1120/1200 300 1.3 0.16 6270/6000 0.5 125 100 1600/1700 375 1.25 0.11 12800/12050 0.5 Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet INPUT SPECIFICATIONS (1) Description 8413xxx0 8413xxx2 8413xxx1 Control Voltage Range Maximum Reverse Voltage Minimum Turn-On Voltage Must Turn-Off Voltage Minimum Input Current (for on-state) [mA] Maximum Input Current [mA] Nominal Input Impedance [Ohms] Maximum Turn-On Time [msec] Maximum Turn-Off Time [msec] 3-32 VDC (4) -32 VDC 3 VDC (4) 1 VDC 10 15 18-36 VAC 18 VAC 4 VAC 13 15 Current Regulated 20 30 90-280 VAC (5) 90 VAC 10 VAC 6 10 1/2 Cycle (6) 1/2 Cycle GENERAL SPECIFICATIONS (1) Description Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 VDC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range (7) Ambient Storage Temperature Range Weight (typical) Housing Material Baseplate Material Input Terminal Screw Torque Range (in-lb/Nm) Load Terminal Screw Torque Range (in-lb/Nm) SSR Mounting Screw Torque Range (in-lb/Nm) Humidity per IEC60068-2-78 LED Input Status Indicator MTBF (Mean Time Between Failures) at 40C ambient temperature (8) MTBF (Mean Time Between Failures) at 60C ambient temperature (8) Parameters 4000 Vrms 109 Ohms 8 pF -40 to 80 C -40 to 125 C 2.53 oz (72 g) UL94 V-0 Aluminum 13-15 /1.5-1.7 18-20 / 2-2.2 18-20 / 2-2.2 93% non-condensing Green 11,641,553 hours (1,328 years) 7,210,376 hours (823 years) GENERAL NOTES (1) All parameters at 25C unless otherwise specified. (2) Output will self trigger between 450-600 Vpk / 900-1200 Vpk for 280 VAC/660 VAC models not suitable for capacitive loads. (3) Heat sinking required, see derating curves. (4) 4-32 VDC for 48-660 VAC models. (5) For ambient temperatures above 40C the maximum control voltage must not exceed 250 VAC. (6) Turn-on time for Instantaneous turn-on versions is 0.1 msec. (7) AC models operating range is -20 to 80C. (8) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report). (9) Load can be wired to either SSR output terminal 1 or 2. (10) For single surge pulse Tc=25C; Tj=125C. For AC Output SSRs, AC Rms value of surge current equals the peak value divided by 2 (1.414). For additional information or specific questions, contact Crydom Technical Support. Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. 20 30 Panel Mount Datasheet WIRING DIAGRAM AC V Load (9) 1 ( ) Recommended Wire Sizes 2 ( ) Input 1 2 OUTPUT Output INPUT 4 (- / ) 3 Wire Pull-Out Strength (lb)[N] 24 AWG (0.2 mm2) / 0.2 [minimum] 10 [44.5] 2 x 12 AWG (3.3 mm2) / 3.3 [maximum] 90 [400] 20 AWG (0.5 S O L I D S TAT E R E L AY 4 Wire Size (Solid / Stranded) Terminals mm2) / 0.518 [minimum] 30 [133] 2 x 10 AWG (5.3 mm2) / 5.3 110 [490] 2 x 8 AWG (8.4 mm2) / 8.4 [maximum] 90 [400] 3 (+ / ) EQUIVALENT CIRCUIT BLOCK DIAGRAMS Input Current vs Input Voltage Standard Regulated DC Input GN Series DC Control -DC 4 +DC 3 AC OUTPUT INPUT 1 Trigger Circuit 2 Current Limiter AC Input Current (mA) 14 Input Current (mA) OUTPUT INPUT 6 4 2 0 3 Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. 5 10 15 20 DC Input Voltage 25 30 35 250 300 Input Current vs Input Voltage Standard Regulated AC Input 6 5 4 3 2 1 0 2 AC Input Current (mA) AC 1 AC 4 Trigger Circuit 8 7 Current Limiter AC/DC Converter 10 0 GN Series AC Control AC 12 16 14 12 10 8 6 4 2 0 0 50 100 150 200 AC Input Voltage Input Current vs Input Voltage Regulated AC Input Option E 0 5 10 15 20 AC Input Voltage 25 30 35 Panel Mount Datasheet MECHANICAL SPECIFICATIONS (1) Tolerances: 0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Screw Termination, IP00 1.1 [27.9] 0.49 [12.4] 0.89 [22.6] Mounting Hole/Slot 0.19 [4.9] DIA. 1.88 [47.6] Screw Termination, IP20 1.10 [27.9] 0.49 [12.4] 1.7 [43.2] 1.88 [47.6] 2.25 [57.3] Mounting Hole/Slot 0.19 [4.9] DIA. 1.7 [43.2] 2.25 [57.3] 2.32 [58.8] 1.0 [25.4] 1.75 [44.5] 1.0 [25.4] 1.75 [44.5] 1.22 [30.9] THERMAL DERATE INFORMATION 25 A 10 A 3C/W 1C/W 5C/W 0.5C/W 6 4 2 25 30 35 40 45 50 55 60 65 70 75 80 5 20 25 30 35 40 45 50 55 60 65 70 75 30 20 10 0 20 80 25 30 35 40 45 50 55 60 65 75 A 100 A 125 A 0.4C/W 1.5C/W 1C/W Load Current (Amps) 45 30 15 30 10 Ambient Temperature (C) 0.7C/W 35 40 45 50 55 60 65 Ambient Temperature (C) 70 75 80 2C/W 40 Ambient Temperature (C) 60 25 1.5C/W 1C/W Ambient Temperature (C) 0.5C/W 0 20 15 100 90 80 70 60 50 40 30 20 10 0 20 0.5C/W 0.4C/W 1C/W 0.7C/W 0.5C/W 70 75 80 1C/W 0.7C/W 120 Load Current (Amps) 20 20 0 0.7C/W 50 Load Current (Amps) Load Current (Amps) Load Current (Amps) 8 75 Load Current (Amps) 3C/W 2C/W 25 10 0 50 A 1.5C/W 25 30 35 40 45 50 55 60 65 Ambient Temperature (C) Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. 70 75 80 100 80 60 40 20 0 20 25 30 35 40 45 50 55 60 65 Ambient Temperature (C) 70 75 80 Panel Mount Datasheet SURGE CURRENT INFORMATION Single Pulse (10) 10 A 25 A 300 Surge Current (Amp) AC Peak Surge Current (Amp) AC Peak 160 140 120 100 80 60 40 20 0 250 200 150 100 50 0 0.01 0.1 1 10 0.01 0.1 Surge Duration (secs) 50 A Surge Current (Amp) AC Peak Surge Current (Amp) AC Peak 10 1 10 1 10 75 A 700 600 500 400 300 200 100 0 1100 1000 900 800 700 600 500 400 300 200 100 0 0.01 0.1 1 10 0.01 0.1 Surge Duration (secs) Surge Duration (secs) 100 A 125 A 1600 Surge Current (Amp) AC Peak 1200 Surge Current (Amp) AC Peak 1 Surge Duration (secs) 1000 800 600 400 200 0 1400 1200 1000 800 600 400 200 0 0.01 0.1 1 10 0.01 Surge Duration (secs) Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. 0.1 Surge Duration (secs) Panel Mount Datasheet AGENCY APPROVALS EN60950-1: Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: Certified according to EN 62314:2006 IEC 61000-4-2 Electrostatic Discharge Level 3 IEC 61000-4-4 Electrically Fast Transients Level 3 IEC 61000-4-5 Electrical Surges Level 3 LR 38595 E79183 ACCESSORIES Recommended Accessories Cover Hardware Kit KS101 HK1 HK4 Heat Sink Part No. Thermal Resistance Lug Terminal Thermal Pad [C/W] HS501DR 5.0 TRM1 HSP-1 HS301 / HS301DR 3.0 TRM6 HSP-2 HS251 2.5 HS201 / HS201DR 2.0 HS202 / HS202DR 2.0 HS172 1.7 HS151 / HS151DR 1.5 HS122 / HS122DR 1.2 HS103 / HS103DR 1.0 HS101 1.0 HS073 0.7 HS072 0.7 HS053 0.5 HS033 0.36 HS023 0.25 Rev. 092816 Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH. * Disconnect all power before installing or working with this equipment. * Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION. * Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo. * Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION * Eteindre toutes les sources d'energie de cet appareil avant de travailler dessus de cet appareil * Verifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lesions serieuses serieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION. * Stellen Sie jeglichen Strom ab, der dieses Gerat versorgt, bevor Sie an dem Gerat Arbeiten durchfuhren * Vor dem Drehen auf Energie alle Anschlusse uberprufen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen konnen zum Tode oder zu schweren Verletzungen fuhren. RISCHIO DI SCOSSA ELETTRICA O DELL'ESPLOSI ONE. * Spenga tutta l'alimentazion e che fornisce questa apparecchiatu ra prima del lavorare a questa apparecchiatu ra * * Verificare tutti i collegamenti e sostituire tutte le coperture prima della rotazione sull'alimentazi one L'omissione di seguire queste istruz ioni provochera la morte o di lesioni serie WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER GEFAHR VON MATERIALSCHADEN UND GEHAUSEERHITZUNG * The product's side panels may be hot, allow the product to cool before touching. * Follow proper mounting instructions including torque values. * Do not allow liquids or foreign objects to enter this product. * Les panneaux lateraux du produit peuvent etre chauds. Laisser le produit refroidir avant de le toucher. * Respecter les consignes de montage, et notamment les couples de serrage. * Ne pas laisser penetrer de liquide ni de corps etrangers a l'interieur du produit. * Die Seitenwande konnen hei sein. Lassen Sie das Produkt abkuhlen, bevor Sie es beruhren. * Beachten Sie die Montageanweisungen, * Fuhren Sie keine Flussigkeiten oder Fremdkorper in das Produkt ein. Le non-respect de cette directive peut entrainer, Failure to follow these instructions can result in des lesions corporelles graves ou des serious injury, or equipment damage. dommages materiels. Die Nichtbeachtung dieser Anweisung kann Korperverletzung oder Materialschaden zur Folge haben. RIESGO DE DANOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO * Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfrie antes de tocarlo. * Respetar las instrucciones de montaje, y en particular los pares de apretado. * No dejar que penetren liquidos o cuerpos extranos en el producto. * I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo. * Seguire le istruzioni di montaggio corrette. * Non far entrare liquidi o oggetti estranei in questo apparecchio. Si no se respetan estas precauciones pueden producirse graves lesiones, danos materiales. La mancata osservanza di questa precauzione puo causare gravi rischi per l'incolumita personale o danni alle apparecchiature. Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. * * * Panel Mount Datasheet ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People's Republic of China Electronic Industry Standard SJ/T11364 - 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr (VI)) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) Semiconductor die Solder - SJ/T11364 - 2006, (Pb) (Hg) (Cd) (Cr (VI)) 50 Do not forget to visit us at: www.crydom.com Copyright (c) 2016 Crydom Inc. Specifications subject to change without notice. (PBB) (PBDE) Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Crouzet: 84138101 84138201 84134012 84134080 84134300 84134901 84137001 84137080 84137142 84137181 84137200 84137240 84137910 84134914