WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3.75KVACI/P-FG:1.88KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC/25 /70%RH
CONSTANTCURRENTREGION Note.4
HLG-240-12 A
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter.
B : IP67 rated. Constant current level adjustable through output cable.
C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal
potential meter.
SPECIFICATION
MODEL
HLG-240-12
HLG-240-15
HLG-240-20
HLG-240-24
HLG-240-30
HLG-240-36
HLG-240-48
DCVOLTAGE
RATEDCURRENT
RATEDPOWER
OUTPUT
VOLTAGE ADJ.RANGE Note.6
CURRENT ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME Note.8
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.5
FREQUENCY RANGE
POWERFACTOR
EFFICIENCY (Typ.)
ACCURRENT
INPUT
INRUSHCURRENT(Typ.)
LEAKAGECURRENT
SAFETY STANDARDS Note.7
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERCURRENT Note.4
OVERVOLTAGE
OVERTEMPERATURE
12V
6~12V
15V
7.5~15V
20V
10~20V
24V
12~24V
30V
15~30V
36V
18~36V
48V
24~48V
16A 15A 12A 10A 8A 6.7A 5A
192W 225W 240W 240W 240W 241.2W 240W
150mVp-p 150mVp-p
14~16V
150mVp-p
18.6~21.4V
150mVp-p
22.4~25.6V
200mVp-p
28~32V
250mVp-p
33.5~38.5V
250mVp-p
44.8~51.2V
2.5%
8~16A
2.0%
7.5~15A
1.0%
6~12A
1.0%
5~10A
1.0%
4~8A
1.0%
3.3~6.7A
1.0%
2.5~5A
11.2~12.8V
Canbeadjusted byinternalpotentialmeterorthroughoutputcable
0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
2.0% 1.5% 1.0% 0.5% 0.5% 0.5% 0.5%
2500ms,80ms atfullload230VAC/115VAC
15ms atfullload230VAC/115VAC
90~264VAC127~373VDC
47~63Hz
PF 0.95/230VACPF 0.98/115VACatfullloadandratedoutputvoltage PF 0.9at65~100%load
90% 90% 92% 93% 93% 93.5% 94%
15.5~18V 16.5~19.5V 22~26V
95 5 (TSW1)
26~33V 32.5~36.5V 40~48V 53~62V
4A /115VAC2A /230VAC
COLDSTART 75A/230VAC
<0.75mA /240VAC
95~108%
Protectiontype:Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
Complianceto EN55015,EN55022(CISPR22)ClassB
CompliancetoEN61000-3-2ClassC( 50%load);EN61000-3-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN61547,EN55024,heavyindustrylevel(surge4KV),criteria A
-40~+60 @fullload ;+70 @60%load(Refertoderatingcurve)
20~95%RH non-condensing
-40~+80 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,5G12min./1cycle,periodfor72min.eachalongX, Y,Zaxes
207.9Khrsmin.MIL-HDBK-217F(25 )
244.2*68*38.8mm(L*W*H)(HLG-240-Blank/A/B)251*68*38.8mm(L*W*H)(HLG-240-C)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A and type C only.
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.
1.3Kg;12pcs/16.6Kg/0.74CUFT(HLG-240-Blank/A/B) 1.23Kg;12pcs/15.8Kg/1.16CUFT(HLG-240-C)
Protectiontype: Shutdownandlatchoffo/pvoltage,re-powerontorecover
240WSingleOutputSwitchingPowerSupply
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potential meter
Suitable for LED lighting and moving sign applications
IP67 / IP65 design for indoor or outdoor installations
Compliance to worldwide safety regulations for lighting
5 years warranty
Suitable for dry / damp / wet locations
(Note.10)
Features :
HLG-240 seri es
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
EMICONDUCTION&RADIATION
SAFETY &
EMC
PROTECTION
105 5 (TSW1)
Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
F110 SELV
IP65 IP67
SHORTCIRCUIT
Hiccupmode,recoversautomaticallyafterfaultconditionisremoved.
Blank : IP67 rated. Cable for I/O connection.
HLG-240-54
54V
27~54V
4.45A
240.3W
350mVp-p
50~57V
1.0%
2.23~4.45A
0.5%
0.5%
HLG-240-42
42V
21~42V
5.72A
240.2W
250mVp-p
39~45V
1.0%
2.86~5.72A
0.5%
0.5%
94% 94%
46~50V 59~65V
UL1012, TUVEN61347-1,EN61347-2-13independent(exceptforHLG-240HCtype),UL60950-1,UL8750, TUVEN60950-1,IP65orIP67approved
http://store.iiic.cc/
MechanicalSpecification
FileName:HLG-240-SPEC 2011-01-31
CaseNo.954CUnit:mm
244.2
244.2
220.2
220.2
12
12
9.6
9.6
-V(Black)
-V(Black)
+V(Red)
+V(Red)
300 20
300 20
FG(Green/Yellow)
FG(Green/Yellow)
AC/L(Brown)
AC/L(Brown)
AC/N(Blue)
AC/N(Blue)
9.4 9.4
9.4 9.4
34.2 34.2
68 68
4.2 4PL
4.2 4PL
300 20
300 20
38.8 38.8
SJTW18AWG 3C
SJTW18AWG 3C
240WSingleOutputSwitchingPowerSupply H LG- 240 series
A Type:(HLG-240-_A)
IP65rated.Outputvoltageandconstantcurrentlevelcanbeadjustedthroughinternalpotentialmeter.
(Canaccessbyremovingtherubberstopperonthecase.)
Blank:(HLG-240)
IP67rated.CableforI/Oconnection.
Vo
ADJ.
Io
ADJ.
SJTW14AWG 2C
SJTW14AWG 2C
http://store.iiic.cc/
ACInput TerminalPinNo.
Assignment
DCOutput TerminalPinNo.
Assignment
PinNo.
PinNo.
1
1
3
2
2
Assignment
Assignment
AC/L
+V
-V
AC/N
FG
244.2
220.2
12
9.6
-V(Black)
+V(Red)
ADJ2(White)
ADJ1(Blue)
38.8
38.8
12V 15V 20V 24V 30V 36V 42V 48V 54V
Open Open Open Open Open Open Open Open Open
680 560 680 510 820 1.8K 680 620 820
120 47 91 51 120 500 82 68 150
Short Short Short Short Short Short Short Short Short
Slightly>100%
Model
75%
50%
Slightly<50%
SJTW18AWG 3C
240WSingleOutputSwitchingPowerSupply H LG -2 40 s e r i e s
CType:(HLG-240-_C)
Outputvoltageandconstantcurrentlevelcanbeadjustedthroughinternalpotentialmeter.
(Canaccessbyremovingtherubberstopperonthecase.)
BType:(HLG-240-_B)
IP67rated.Outputconstantcurrentlevelcanbeadjustedthroughoutputcablebyconnectingaresistorbetween ADJ1and ADJ2.
Referenceresistancevalueforoutputcurrentadjustment(Typical)
300 20
FG(Green/Yellow)
AC/L(Brown)
AC/N(Blue)
9.4 9.4
34.2
68
4.2 4PL
300 20
I/P
8
15.4
1
2
3
88
220.2
251
1
2O/P
Vo
ADJ.
Io
ADJ.
4.2 4PL
37
68
7.5 9.5
FileName:HLG-240-SPEC 2011-01-31
SJTW14AWG 2C
SJTW18AWG 2C
Percentage
ofratedcurrent
http://store.iiic.cc/
fosc:100KHz
DeratingCurve StaticCharacteristics
INPUTVOLTAGE(V)60Hz
90 100 125 135 145 155 165 175 180 200 230 264
100
90
80
70
60
50
40
LOAD(%)
ADJ1
(B Type)
ADJ2
Fosc:100KHz
DETECTION
PWM&PFC CIRCUIT
O.L.P.
EMIFILTER
RECTIFIERS
POWER
SWITCHING
FILTER
&
RECTIFIERS +V
-V
I/P
FG
CONTROL
O.V.P.
&
O.L.P.
PFC
CIRCUIT
PFC
CONTROL
BlockDiagram
PowerFactorCharacteristic
Powerfactorwillbehigherthan0.9whenoutputloadingis65%orhigher.
EFFICIENCY vsLOAD(48VModel)
HLG-240seriespossesssuperiorworkingefficiencythatupto94%canbereachedinfieldapplications.
LOAD
EFFICIENCY (%)
FileName:HLG-240-SPEC 2011-01-31
110V
110V
230V
230V
AMBIENTTEMPERATURE( )
LOAD(%)
-40 -25 -10 0 15 30 50 60 70
20
40
60
80
100
(HORIZONTAL)
230VAC
100VAC
0 .8
0 .8 2
0 .8 4
0 .8 6
0 .8 8
0 .9
0 .9 2
0 .9 4
0 .9 6
0 .9 8
1
1 .0 2
3 0 % 4 0 % 5 0 % 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 %
240WSingleOutputSwitchingPowerSupply HL G- 24 0 seri e s
PF
LOAD
ConstantCurrentMode
76
78
80
82
84
86
88
90
92
94
96
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
http://store.iiic.cc/
240WSingleOutputSwitchingPowerSupply H LG -2 40 s e r i e s
FileName:HLG-240-SPEC2011-01-31
TherearetwomajorkindsofLEDdrivemethod"directdrive"and"withLEDdriver".
Directdriving:
TypicalLEDpowersupplyI-Vcurve
Underdirectdriving,thepowersupplywillworkin"constantcurrentmode(CC)"andoutputvoltageofthepowersupplywillbeclampedbysumof
forwardvoltage(V )oftheLEDstrip.F
ThetotalforwardvoltageofseriesconnectingLEDsissuggestedfor75%~95%ofpowersupplyratedoutputvoltageduetoconcernofthebestPF
valueandefficiency.
A typicalLEDpowersupplymayeitherworkin"constantvoltagemode(CV)orconstantcurrentmode(CC)"todrivetheLEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
DRIVINGMETHODSOFLEDMODULE
Vo(%)
100
50
50 95
(max.)
Io (%)
Constant
Voltage area
Constant
Current area
Hiccup
Protection
(A)
(B)
(C)
AC
source I/P O/P
HLG-240
WithLEDdriver
Usingadditionaldriver,thepowersupplywillworkin"constantvoltagemode(CV)"andoutputvoltageofthepowersupplywillbekeptinratedvalue.
Inthisdrivemode,severaldesignissuesneedtobeconsidered:
1.OutputvoltageofPSUmustbehigherthantotalforwardvoltageofseriesconnectingLEDsby3Vminimum.
2.Inputcapacitor(Cin)ofLEDdrivercircuitshoulduse2.2uF~22uF(typ.)ofratingdependsontheoperatingfrequencyoftheLEDdriver.
Thehighertheoperatingfrequencyisused,thesmallervalueofCinshouldbechosen,andviceversa.
AC
source I/P O/P
ICCircuit
Cin Cout VF
R
L
HLG-240
~
~
~
~
http://store.iiic.cc/
240WSingleOutputSwitchingPowerSupply H LG -2 40 s e r i e s
FileName:HLG-240-SPEC2011-01-31
~
~
AC
source I/P
FG
C
BD AA
O/P
LEDCCdriver
ChassisofLEDLamp
CC
IC
HLG-240
A. Addacommonmodeferritechokeonoutputwirestoreducethecommonemissionbetween10M~300MHzperlightingEMIregulation.
B.ChassisofLEDlampandchassisofHLG-240ortheFGwireshouldbeconnectedtothesafetygroundtoreducetheEMInoise,includingtheconduction
andradiationemission.
C. TheadditionalX-Capanddischargeresistorcanreducethel conductionnoisebetween9K~1MHzperlightingEMIregulation.
D.L-Cfiltershould beaddedattheDCinputofLEDconstantcurrentdrivertoavoidthedifferentialemissionandhighfrequencynoisegeneratedbythe
CCdriver.
owfrequency
Waterproofconnector
WaterproofconnectorcanbeassembledontheoutputcableofHLG-240tooperatein wet/damporoutdoorenvironment.
HLG-240
I/P O/P
LEDLamp
AC
source
CableJoiner
PinConfiguration(Female) PinConfiguration(Female)
Size Size
M12 M15
4-PIN
5A/PIN
M12-04OrderNo. OrderNo.
10A max.SuitableCurrent SuitableCurrent
5-PIN
5A/PIN
M12-05
10A max.
2-PIN
12A/PIN
M15-02
12A max.
Uptofourwirescanbeconnectedthroughthiscablejoinerby
solderingorclampingbytools.
66
26 20
25
Suitablefor14AWG~22AWG
O/P Wires
LEDLamp
HLG-240
EMIDEBUGSUGGESTION
WATERPROOFCONNECTION