POWERSEM GmbH, Walpersdorfer Str. 53 2003 POWERSEM reserves the right to change limits, test conditions and dimensions
91126 D- Schwabach
Phone: 09122 - 9764-0 Fax.: 09122 - 9764-20
Single Phase PSBH 125 IdAV = 123 A
Half Controlled Bridges VRRM = 400-1600 V
Preliminary Data Sheet
VRSM
VDSM
VRRM
VDRM
Type
500 400 PSBH 125/04
900 800 PSBH 125/08
1300 1200 PSBH 125/12
1500 1400 PSBH 125/14
*1700 *1600 PSBH 125/16
* Delivery on request
Symbol Test Conditions Maximum Ratings
IdAV TC = 85 °C, module 123 A
IFSM, ITSM TVJ = 45°C t = 10 ms (50 Hz), sine 1500 A
VR = 0 t = 8.3 ms (60 Hz), sine 1600 A
TVJ = TVJM t = 10 ms (50 Hz), sine 1350 A
VR = 0 t = 8.3 ms (60 Hz), sine 1450 A
∫ i2 dt TVJ = 45°C t = 10 ms (50 Hz), sine 11 200 A2 s
VR = 0 t = 8.3 ms (60 Hz), sine 10 750 A2 s
TVJ = TVJM t = 10 ms (50 Hz), sine 9100 A2 s
VR = 0 t = 8.3 ms (60 Hz), sine 8830 A2 s
(di/dt)cr TVJ = TJVM repetitive, IT = 50 A 150 A/µs
f = 400Hz, tP = 200µs
VD = 2/3 VDRM
IG = 0.3 A non repetitive, IT = 1/3 . IdAV 500 A/µs
diG/dt = 0.3 A/µs
(dv/dt)cr TVJ = TVJM V
DR = 2/3 VDRM 1000
V/µs
RGK = ∞, method 1 (linear voltage rise)
PGM TVJ = TVJM tP = 30µs ≤ 10 W
IT = ITAVM tP = 500µs ≤ 5 W
PGAVM 0.5 W
VRGM 10 V
TVJ -40 ... + 125 °C
TVJM 125 °C
Tstg -40 ... + 125 °C
VISOL 50/60 HZ, RMS t = 1 min 2500 V ∼
IISOL ≤ 1 mA t = 1 s 3000 V ∼
Md Mounting torque (M6) 5 Nm
Terminal connection torque (M6) 5 Nm
Weight typ. 270 g
Features
• Package with screw terminals
• Isolation voltage 3000 V∼
• Planar glasspassivated chips
• Low forward voltage drop
• UL released, E 148688
Applications
• Heat and temperature control for
industrial furnaces and chemical
processes
• Lighting control
• Motor control
• Power converter
Advantages
• Easy to mount with two screws
• Space and weight savings
• Improved temperature and power
cycling capability
• High power density
Package, style and outline
Dimensions in mm (1mm = 0.0394“)
~
~