111-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
MB Series
Features
u High Attenuation Wide Band Two Stage Filter
u Screw Terminals with Cover
u Low Profi le, Metal Case
6A to 36A, 250VAC EMI Filters
Model MB1206 MB1210 MB1216 MB1220 MB1236
Rated Voltage (AC,DC) V 250V
Rated Current (AC,DC) (1) A 6 10 16 20 36
Test Voltage V 2500V (20mA) at 25°C, 70% RH
(terminal to case, AC 1 min.)
Isolation Resistance Ω 100M Ohms min. at 25°C, 70% RH
(terminal to case, 500VDC)
Leakage Current - 125V, 60Hz =0.5mA max.; 250V, 60Hz =1mA max.
DC Resistance mΩ 140 50 34 20 9
Temperature Rise °C 40°C max.
Operating Temperature (1) °C -25 to +85°C
Operating Humidity % 30% to 95% RH (non-condensing)
Storage Temperature °C -40 to +85°C
Storage Humidity % 10% to 95% RH (non-condensing)
Vibration - Sweep:10-55-10Hz (1min.), Amplitude 1.5mm X, Y, and Z axes, 2 hours each
Safety Standard - UL1283, CSA C22.2 No.8 (C-UL), VDE0565 Teil3, Teil3A2, and EN133200 (VDE)
Specifi cations
Notes:
(1) Value at Ta ≤35°C. Refer to the derating curve at Ta > 35°C.
Last time buy - December 2014