1157 FIBER SENSORS Area Ionizer Pulse AC Method ER-X SERIES Related Information General terms and conditions.............. F-3 Glossary of terms.......................... P.1591 Selection guide............................ P.1155~ General precautions...................... P.1595 LASER SENSORS PHOTOELECTRIC SENSORS Certified by NRTL MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS panasonic.net/id/pidsx/global STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS High-Speed, Wide Area Charge Removal "Fast Charge Removal", "Airless", "Low-Pressure". Three charge removal modes for diverse application coverage The ER-X series offers an airless charge removal capability to eliminate the need for compressed air in addition to low pressure and high speed compressed air based modes. Furthermore, it supports dual-head configurations for expanded application coverage. MACHINE VISION SYSTEMS UV CURING SYSTEMS Head 1 Selection Guide Static Removers Head 2 Pulse Air-gun Cleaning Box Electrostatic Sensor ER-X ER-TF ER-VS02 Fast Charge Removal Airless or LowPressure ER-VW ER-Q ER-F Massive ion discharge when using air reduces charge removal time Prevents dust dispersion and cleanliness degradation! By applying a compressed air source, the ion volume increases providing an improved tact time for substrate ionization. This makes the ER-X suitable for applications such as electronic paper and thin film solar cells, where charge removal time is directly linked to productivity. The ER-X series can effectively remove surface charges with an air pressure of less than 0.05 MPa. With the advantage of minimal dust dispersion, it is suitable for charge removal in semiconductor, FPD (mobile panel), and other applications that require high degree of cleanliness. The presence of air also helps prevent adhesion of dust to the discharge needles, requiring less cleaning than in the airless charge removal mode. Area Ionizer ER-X SERIES Pulse AC method for faster charge removal Automatic ion balance control The ER-X series has adopted the pulse AC method that alternately applies positive and negative voltages to each discharge needle. This enables generation and discharge of a large amount of ions, resulting in faster charge removal. Select from eight pulse frequencies according to your application, from 100 Hz for charge removal on nearby or moving workpieces to 1 Hz for charge removal on far-away workpieces or in a threedimensional space. The ER-X series provides an automatic ion balance control mechanism that senses the amount of ions being generated (which changes according to environmental factors) and compensate for this deviation in the controller, thus maintaining a highly stable ion balance as an original operator setting. Charge removal time characteristics (TYPICAL) Positive ion generation Example of variable discharge frequency/ion balance Measured at a charge removal distance of 100 mm 3.937 in using a 150 x 150 mm 5.906 x 5.906 in CPM (at center of CPM). Charge voltage (V) 1,000 Conventional model, with airflow, 0.05 MPa ER-X032, airless ER-X032, with airflow, 0.05 MPa 800 Negative ion generation Conventional model 400 0 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS 600 200 1158 SIMPLE WIRE-SAVING UNITS Variable ion balance ER-X SENSOR OPTIONS WIRE-SAVING SYSTEMS 1 2 3 Charge removal time (sec.) 4 MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS SPOT TYPE HEAD ER-X001 Effective charge removal width: 50 mm 1.969 in approx. 0.3 sec. or less*1 fastest charge removal achieved with pulse AC method spot type ionizer*2 The pulse AC method enables the ER-X001 to generate and discharge a large amount of ions, which makes charge removal faster. Furthermore, as a spot type ionizer, it achieves the fastest charge removal of 0.3 sec. or less*1 (1,000 V 100 V). *1: As of March 2016, in-company survey *2: Spot diameter of o15 mm o0.591 in or less PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Static Removers Pulse Air-gun Supports airless and low-pressure charge removal, which means charge removal is possible without blowing away tiny work pieces Air supply port angle can be adjusted ER-X001 high-voltage unit Cleaning Box Electrostatic Sensor ER-X ER-TF Free head placement is possible thanks to flexible cable with internal air tube ER-VS02 ER-VW Joint for o6 mm o0.236 in air tube 360 angle adjustment ER-Q ER-F 1159 FIBER SENSORS Area Ionizer ER-X SERIES BAR TYPE HEAD High and low temperature resistant type head also available LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS ER-XHC ER-X008 Effective charge removal width: 80 mm 3.150 in approx. Bar type head compatible with ambient temperatures of -60 to +200 C -76 to +392 F is available. ER-X016 Effective charge removal width: 160 mm 6.299 in approx. ER-X032 Effective charge removal width: 320 mm 12.598 in approx. ER-X048 Effective charge removal width: 480 mm 18.898 in approx. ER-X064 Effective charge removal width: 640 mm 25.197 in approx. Super-compact slim head Discharge needle air barrier design for reduced contamination By thoroughly redesigning the discharge needle, we have created a super-compact slim head that combines high-speed charge removal*1 with a maintenance-saving design*2. The ER-X series can be embedded in, or retrofitted onto, equipment that did not provide enough space for antistatic measures in the past. A barrier of clean air around the discharge needle keeps foreign matter from adhering to it, preventing degraded performance. Additionally, by using separate air sources for the discharge needle barrier and ion transport, the ER-X series keeps discharge from becoming unstable due to pressure concentration, allowing the device to efficiently generate and transport ions. *1: Pulse AC method with built-in air tubes (max. pressure 0.5 MPa) *2: Discharge needle air barrier structure, discharge needle unit for simple need replacement Air barrier structure Discharge needle after protected by air barrier (0.05 MPa) for one month Efficient charge removal structure FA COMPONENTS MACHINE VISION SYSTEMS Angle adjustment screw 360degree angle adjustment 30 mm (1.181 in) UV CURING SYSTEMS 22 mm (0.866 in) Selection Guide Static Removers Carefully designed to prevent contamination in manufacturing processes In consideration of the manufacturing process (secondary cells etc.), the ER-X series heads neither use copper nor plate processing. This minimizes the risk of contamination with foreign substances. Pulse Air-gun Cleaning Box Electrostatic Sensor ER-X ER-TF ER-VS02 ER-VW Flat discharge surface for easy cleaning Discharge needle unit for simple needle replacement The ER-X series heads have a flat discharge face, allowing effortless cleaning of the discharge needles and air outlets by simply brushing along the groove provided. The removable discharge needle unit (including a set of four needles) substantially simplifies maintenance. To remove the unit, just slide it toward both ends as indicated by the arrows. ER-Q Discharge needles ER-F Air outlets Groove Commercial brush Discharge needle unit Area Ionizer ER-X SERIES CONTROLLER FIBER SENSORS Dual head configuration for enhanced charge area and layout expansion 1 controller 1160 LASER SENSORS + 2 heads PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS * Different heads can be combined. * The new-type controller, ER-XC02, allows simultaneous connection of the bar type head and spot type head. * Charge removal is possible with a layout that places heads on either side of the workpiece. * The charge removal efficiency can be increased by synchronizing the two heads. Controller AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS High-voltage unit WIRE-SAVING SYSTEMS ER-XC02 High-voltage unit Head 1 Head 2 Equipped with charging function The charging function is useful when charging paper or parts for static electricity adsorption transport. MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC Discharge indicator (green) HUMAN MACHINE INTERFACES Notes: 1) Head 2 performs the ordinary charge neutralizing operation. 2) The ER-X001 cannot use the charging function. (Discharge operation stops.) Lights up during discharge. ENERGY MANAGEMENT SOLUTIONS CHECK indicator (orange) All-in-one model equipped with various functions for optimal removal of charge Lights up when dirt, wear, etc. of the discharge needle is detected. FA COMPONENTS Level meter indicator (green) Lights up when abnormal discharge is detected. Indicates static buildup around the head or the amount of ion generated from the head. ERROR indicator (red) Discharge frequency setting switch Selection Guide Static Removers Notes: 1) Head 2 performs the ordinary charge removal operation. Pulse Air-gun Ion balance setting switch Turn ion generation on and off. Adjust the ion balance to any of 15 levels according to the strength of the charge on the workpieces. Various setting switch SET UP button Determine the settings of discharge frequency and ion balance. * Check level changeover switch Set the maintenance notification level to "standard" or "high-sensitivity." * Ion balance control switch Enable or disable the ion balance auto control function. * Indicator changeover switch Set the level meter indicator display mode to "charge strength display" or "ion generation volume display." Discharge control input Turn ion generation on and off from an external device. Alarm output, error output Report maintenance timing and malfunctions to an external device. UV CURING SYSTEMS Select from eight ion generation frequencies ranging from 100 Hz to 1 Hz according to your application. Head 1 can be used as a charger when the discharge frequency setting switch for Head 1 is set to "+ Charge" or "Charge." 2)The ER-X001 cannot use the charging function. (Discharge operation stops.) Discharge control switch MACHINE VISION SYSTEMS * 2 heads control switch Set the ion generation timing for the two heads to "synchronize" or "inverse." * Error output changeover switch Set the error output condition to "generation of abnormal discharge" or "generation of abnormal discharge + discharge stop setting ON." Cleaning Box Electrostatic Sensor ER-X ER-TF ER-VS02 ER-VW ER-Q ER-F 1161 FIBER SENSORS LASER SENSORS Area Ionizer ER-X SERIES APPLICATIONS Preventing electrostatic damage during bonding High-speed charge removal on a taping machine Airless charge removal of minute components on a conveyor belt Removal of static charges on laminate film Prevention of part feeder clogging High-speed charge removal on FPCs Charge removal and dust removal while separating TAB protective film Charge removal of molded plastic components on a conveyor belt Charge removal and dust removal of digital camera cases on a conveyor belt Removing dust during instrument panel assembly Removing dust during food product cup transport Preventing adhesion of molded parts to molds PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Static Removers Pulse Air-gun Cleaning Box Electrostatic Sensor ER-X ER-TF ER-VS02 ER-VW ER-Q ER-F High and low temperature resistant type ER-XHC Area Ionizer ER-X SERIES 1162 ORDER GUIDE FIBER SENSORS LASER SENSORS Heads Head connection cable is not supplied with the head. Please order it separately. Type Spot type Appearance Charge removal time (1,000 V100 V) Ion balance 0.3 sec. or less (Note 1), 0.5 sec. or less (Note 2) Effective charge removal width 50 mm 1.969 in approx. Model No. ER-X001 (Note 4) ER-X008 80 mm 3.150 in approx. High and low temperature resistant PRESSURE / FLOW SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS 160 mm 6.299 in approx. ER-X016HC (Note 5) 30 V or less (Note 2, 3) 1 sec. or less (Note 2) ER-X032 320 mm 12.598 in approx. ER-X032HC (Note 5) 480 mm 18.898 in approx. ER-X048HC (Note 5) ER-X064 High and low temperature resistant SAFETY LIGHT CURTAINS / SAFETY COMPONENTS ER-X008HC ER-X048 High and low temperature resistant AREA SENSORS INDUCTIVE PROXIMITY SENSORS (Note 5) High and low temperature resistant and low temperature resistant MICRO PHOTOELECTRIC SENSORS (Note 4) ER-X016 Bar type High PHOTOELECTRIC SENSORS 640mm 25.197 in approx. SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS ER-X064HC (Note 5) Notes: 1) Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge frequency 50 Hz and air supply 60 /min. (0.3 MPa). 2) T ypical value in condition of discharge distance 100 mm 3.937 in (ER-X001: 50 mm 1.969 in), center of the product, discharge frequency 50 Hz (ERXHC: 30 Hz) and no air supply. 3) Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature change is less than 10 C, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON. 4) T he ER-X001 and ER-X008 must be combined with the new-type ER-XC02 controller. For the Identification of previous-type and new-type controllers and for the combination with the head, refer to p.1171. 5) The ER-XHC high / low temperature resistant type head can be used under temperatures from -60 to +200 C -76 to +392 F. Be sure to use this head in combination with the new-type controller, ER-XC02. For the Identification of previous-type and new-type controllers and for the combination with the head, refer to p.1171. Selection Guide Static Removers Pulse Air-gun Cleaning Box Electrostatic Sensor ER-X ER-TF ER-VS02 ER-VW ER-Q ER-F 1163 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Area Ionizer ER-X SERIES ORDER GUIDE Controller Please order power cable or AC adapter separately. Type Appearance Standard type Appearance SIMPLE WIRE-SAVING UNITS STATIC CONTROL DEVICES LASER MARKERS PLC Designation Power cable Description Length: 2 m 6.562 ft, Net weight: 120 g approx. ER-XCCJ5H Length: 5 m 16.404 ft, Net weight: 290 g approx. ER-XCCJ10H (Note) Length: 10 m 32.808 ft, Net weight: 560 g approx. Length: 2 m 6.562 ft Net weight: 80 g approx. ER-XCC5 Length: 5 m 16.404 ft Net weight: 190 g approx. ER-XAPS AC cable Discharge needle unit Cleaning Box Electrostatic Sensor Description ER-XCC2 AC adapter Selection Guide Pulse Air-gun PhotoMOS relay ER-XCCJ2H Model No. ER-XAPS-EX MACHINE VISION SYSTEMS Static Removers Max. 2 units Cabtyre cable with both connector OPTIONS ENERGY MANAGEMENT SOLUTIONS UV CURING SYSTEMS ER-XC02 Note: Cannot be used with the high and low temperature resistant type head ER-XHC. HUMAN MACHINE INTERFACES FA COMPONENTS Output Model No. SENSOR OPTIONS MEASUREMENT SENSORS Number of heads connected Head connection cables Head connection cable is not supplied with the head. Please order it separately. PARTICULAR USE SENSORS WIRE-SAVING SYSTEMS Model No. 0.15 mm2 10-core cabtyre cable with connector Cable outer diameter: o5.3 mm o0.209 in IN: 100-240 V AC, 50/60 Hz OUT: 24 V DC, 1.5 A Ambient temperature: 0 to +40 C +32 to +104 F Cable length between connector and AC adaptor: 1.8 m 5.905 ft Ground wire: 3.7 m 12.139 ft AC cable: 1 pc., Cable length 1.8 m 5.906 ft, Rating 125 V AC (Note 1) Wiring connector terminals: 6 pcs. Power cable ER-XCC AC adapter ER-XAPS-EX ER-XAPS CN-ACCN-C2 AC cable (conforming to CCC), Length: 2 m 6.562 ft CN-ACKR-C2 AC cable (conforming to KTL), Length: 2 m 6.562 ft Discharge needle unit ER-XANT For ER-X016/X032/X048/X064. (Note 2) Unit with replacement tungsten needles: 1 pc. ER-XANT ER-XANTHC ER-XANT1 For ER-X001. Unit with replacement tungsten needles: 1 pc. ER-XANT2 For ER-X008. (Note 2) Unit with replacement tungsten needles: 1 pc. ER-XANTHC For ER-X016HC/X032HC/X048HC/X064HC. Unit with replacement tungsten needles: 1 pc. ER-XANT1 ER-XANT2HC For ER-X008HC. Unit with replacement tungsten needles: 1 pc. ER-X ER-TF ER-VS02 Discharge part protective cover ER-XACVR ER-VW ER-Q ER-F For ER-X016/X032/X048/X064. (Note 2) Enables to prevent electric shock by mounting to the heads. 2 pcs. per set. (Note 3) Material: Polycarbonate, Weight: 20 g approx. (1 set) * No effect on charge removal capacity of the heads by mounting a discharge part protection cover Notes: 1) Rating of the AC cable is 125 V AC. If the voltage used exceeds 125 V AC, prepare a proper cable by yourself or purchase our optional cable CN-ACCN-C2 or CN-ACKR-C2. And, the AC cable is not enclosed with ER-XAPS-EX. 2) Cannot be used with the high and low temperature resistanttype head ER-XHC. 3) The number of set(s) you need depends on the head model No. Model No. No. of set (2 pcs per set) ER-X016 ER-X032 ER-X048 ER-X064 1 set 2 sets 3 sets 4 sets ER-XANT2 ER-XANT2HC Discharge part protective cover ER-XACVR Area Ionizer ER-X SERIES 1164 SPECIFICATIONS FIBER SENSORS LASER SENSORS Heads Item Type Spot type Model No. ER-X001 Bar type ER-X008 ER-X016 CE marking directive compliance Effective charge removal width Charge removal time (1,000 V100 V) 50 mm 1.969 in approx. 80 mm 3.150 in approx. 50 Hz / 30 Hz / 20 Hz / 10 Hz / 5 Hz / 1 Hz 100 Hz / 70 Hz / 50 Hz / 30 Hz / 20 Hz / 10 Hz / 5 Hz / 1 Hz (Note 4) 7,000 V approx. Discharge output voltage 0.5 MPa Maximum air pressure SENSOR OPTIONS Air (dried clean air) (Note 5) Applicable fluid 2,000 m 6561.68 ft or less (Note 6) Operating altitude 0 to +50 C +32 to +122 F (ER-X001: 0 to +40 C +32 to +104 F) (No dew condensation allowed), Storage: -10 to +65 C +14 to +149 F Ambient temperature 35 to 65 % RH, Storage: 35 to 85 % RH Ambient humidity 10 to 55 Hz (ER-X001: 10 to 150 Hz) frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each Vibration resistance 100 m/s2 acceleration (10 G approx.), in X, Y and Z directions three times each Shock resistance Main unit enclosure: PPS, Stainless steal (SUS), Head mounting bracket: Stainless steal (SUS), Discharge needle: PC, PPS, Tungsten (Note 7) [ER-X001 - Main unit enclosure: Stainless steel (SUS), Head mounting bracket: Stainless steel (SUS), Discharge needle: PFA, Tungsten] STATIC CONTROL DEVICES 1.2 m 3.937 ft 0.5 m 1.640 ft Net weight 370 g approx. 330 g approx. 0.5 m 1.640 ft (Note 4) 410 g approx. 530 g approx. 650 g approx. 780 g approx. Head mounting bracket (mounted at the factory) Accessory Type ER-X008HC ER-X016HC 80 mm 3.150 in approx. 160 mm 6.299 in approx. Ion balance ER-X064HC 320 mm 12.598 in approx. 480 mm 18.898 in approx. 640 mm 25.197 in approx. ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS 1 sec. or less (Note 2) MACHINE VISION SYSTEMS 30 V or less (Note 2, 3) UV CURING SYSTEMS 30 Hz (Note 8) Discharge frequency 7,000 V approx. Discharge output voltage 0.01 ppm or less (Note 2) Ozone generation 0.1 MPa Maximum air pressure Selection Guide Air (dried clean air) (Note 5) Applicable fluid Static Removers 2,000 m 6561.68 ft or less (Note 6) Operating altitude Head: -60 to +200 C -76 to +392 F (No dew condensation or icing allowed) (Note 9), Storage: -10 to +65 C +14 to +149 F High voltage unit: 0 to +50 C +32 to +122 F (No dew condensation allowed), Storage: -10 to +65 C +14 to +149 F Pulse Air-gun Cleaning Box Electrostatic Sensor 35 to 65 % RH, Storage: 35 to 85 % RH Ambient humidity 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each 100 m/s2 acceleration (10 G approx.), in X, Y and Z directions three times each Shock resistance ER-X Floating Enclosure grounding method Material ER-X048HC Pulse AC method Discharge method Vibration resistance HUMAN MACHINE INTERFACES EMC Directive, RoHS Directive Charge removal time (1,000 V100 V) Ambient temperature ER-X032HC LASER MARKERS PLC High and low temperature resistant CE marking directive compliance Effective charge removal width WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Length of high-voltage cable Model No. SIMPLE WIRE-SAVING UNITS Floating Enclosure grounding method Material INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS 0.01 ppm or less (Note 2) Ozone generation AREA SENSORS PRESSURE / FLOW SENSORS Pulse AC method 50 Hz / 20 Hz MICRO PHOTOELECTRIC SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS 30 V or less (Note 2, 3) Discharge frequency Main unit enclosure: PPS, Stainless steal (SUS), Head mounting bracket: Stainless steal (SUS), Discharge needle: PC, PPS, Tungsten, Main unit enclosure of high-voltage unit: ABS 420 g approx. 490 g approx. 620 g approx. 760 g approx. ER-TF ER-VS02 ER-VW Heat-resistant shielded cable, 1.8 m 5.906 ft long Length of high-voltage cable Accessories ER-X064 1 sec. or less (Note 2) Discharge method Net weight ER-X048 160 mm 6.299 in approx. 320 mm 12.598 in approx. 480 mm 18.898 in approx. 640 mm 25.197 in approx. 0.3 sec. or less (Note 1), 0.5 sec. or less (Note 2) Ion balance Item ER-X032 EMC Directive, RoHS Directive PHOTOELECTRIC SENSORS 900 g approx. o6 o0.236-4 air tube joint: 1 pc., Seal cap: 1 pc., Head mounting bracket (mounted at the factory) Notes: 1) Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge frequency 50 Hz and air supply 60 /min.(0.3 MPa). 2) Typical value in condition of discharge distance 100 mm 3.937 in (ER-X001: 50 mm 1.969 in), center of the product, discharge frequency 50 Hz (ERXHC: 30 Hz) and no air supply. 3)Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature change is less than 10 C, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON. 4)The high-voltage cable is also available in lengths of 1 m 3.281 ft and 2 m 6.562 ft. The discharge frequency of 1 m 3.281 ft / 2 m 6.562 ft cables is 50 / 30 / 20 / 10 / 5 / 1 Hz. For details, please contact our sales office. 5) The dried clean air is the air dried (dew point: equivalent of -20 C -4 F) and filtered (mesh-size: equivalent of 0.01 m). 6) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. 7) Silicon needles (ER-X016S, ER-X032S and ER-XANS) are also available. For details, please contact our sales office. 8) Set the discharge frequency to 30 Hz. Do not use any other frequency. 9) Discoloration of the head may occur when used under high temperatures, but it does not affect the charge removal performance. ER-Q ER-F 1165 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Area Ionizer ER-X SERIES SPECIFICATIONS Allowable ambient temperature of high and low temperature resistant type head ER-XHC and its installation When installing, make sure to expose a section measuring 500 mm 19.685 in or more to the normal temperature area as shown below for the protection of the high-voltage unit. Allowable ambient temperature of the head -60 to +200 C -76 to +392 F AREA SENSORS Head SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS Allowable ambient temperature of the high-voltage unit 0 to +50 C +32 to +122 F High-voltage unit High-voltage cable (1.8 m 5.906 ft) 500 mm 19.685 in or more Head connection cable (Note) INDUCTIVE PROXIMITY SENSORS Note: The high and low temperature resistant type ER-XHC cannot be connected with the ER-XCCJ10H head connection cable (10 m 32.808 ft in length). PARTICULAR USE SENSORS Controller SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES Item Supply voltage Current consumption UV CURING SYSTEMS DSC (Discharge) CHECK ERROR Level meter Output ALARM ERROR COM (Common) Output operation Short-circuit protection Discharge control input (DSC OFF) Static Removers Pulse Air-gun Cleaning Box Electrostatic Sensor ER-X ER-TF ER-VS02 ER-VW ER-Q ER-F Maximum 2 units 24 V DC 10 % 450 mA or less when connecting 1 head, 800 mA or less when connecting 2 heads Green LED (lights up when discharging) Orange LED (lights up when dirt, wear, etc. of the discharge needle is detected) Red LED (lights up when abnormal discharge is detected) Green LED (5 levels, lights up depending on amount of the charge or ion generation) PhotoMOS relay output * Maximum load current: 100 mA * Applied voltage: 30 V DC or less (between output-output common) * Residual voltage: 1.5 V or less (at 100 mA load current) ALARM: ON when dirt or wear of the discharge needle is detected, OFF when operation is normal. ERROR: OFF when abnormal discharge is detected, ON when operation is normal. Incorporated (automatic reset type) Discharge allowed: Open, Discharge halt: 24 V or 0 V shorted Contamination level 2 Overvoltage category I Elevation Selection Guide EMC Directive, RoHS Directive Displays status of Head 1 and 2 Indicator FA COMPONENTS MACHINE VISION SYSTEMS ER-XC02 Number of heads connected PLC ENERGY MANAGEMENT SOLUTIONS Controller CE marking directive compliance LASER MARKERS HUMAN MACHINE INTERFACES Type Model No. Ambient temperature Ambient humidity Voltage withstandability 2,000 m 6561.68 ft or less (Note) 0 to +50 C +32 to +122 F (No dew condensation allowed), Storage: -10 to +65 C +14 to +149 F 35 to 65 % RH, Storage: 35 to 85 % RH 1,000 V AC for one min. between all supply terminals connected together and enclosure 500 V AC for on min. between supply terminals and F.G. Insulation resistance 20 M, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each Shock resistance Enclosure grounding method Material Weight Accessories 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each Floating Enclosure: ABS Net weight: 130 g approx. Power supply / I/O connector: 1 set (Housing 5557-10R, Terminal 5556TL [manufactured by Molex]) Ground wire (3.7 m 12.139 ft approx.): 1 pc. Note: Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. Area Ionizer CHARGE REMOVAL CHARACTERISTICS (TYPICAL) ER-X SERIES 1166 Please contact our office for details on data that is not listed here. LASER SENSORS Measured using a 150 x 150 mm 5.906 x 5.906 in CPM (charge plate monitor). (At center of CPM) Air flow Correlation between charge removal distance and charge removal time (50 Hz) 10 ER-X001 ER-X008 80 Charge removal time (sec.) Air flow [/min. (ANR)] 100 60 40 20 0 PHOTOELECTRIC SENSORS ER-X001 0.1 0.2 0.3 0.4 Airless 0.005 MPa 0.1 MPa 0.3 MPa 0.5 MPa 8 6 CPM Center 4 L 2 0 0.5 Applied pressure (MPa) MICRO PHOTOELECTRIC SENSORS Correlation between charge removal distance and charge removal time (20 Hz) 10 Charge removal time (sec.) Common to ER-X001/X008 AREA SENSORS Airless 0.005 MPa 0.1 MPa 0.3 MPa 0.5 MPa 8 6 Center 4 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS CPM PRESSURE / FLOW SENSORS L INDUCTIVE PROXIMITY SENSORS 2 0 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) PARTICULAR USE SENSORS 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS ER-X001 1 sec. 2 sec. 5 sec. 10 sec. 50 100 150 200 250 1.969 3.937 5.906 7.874 9.843 Charge removal distance L (mm in) 250 9.843 200 7.874 150 5.906 100 3.937 50 1.969 0 -50 -1.969 -100 -3.937 -150 -5.906 -200 -7.874 -250 -9.843 0 CPM Center + L - W 1 sec. 2 sec. 5 sec. 10 sec. 50 100 150 200 250 1.969 3.937 5.906 7.874 9.843 Charge removal distance L (mm in) 250 9.843 200 7.874 150 5.906 100 3.937 50 1.969 0 CPM Center + L - W -50 -1.969 -100 -3.937 -150 -5.906 -200 -7.874 -250 -9.843 0 WIRE-SAVING SYSTEMS Charge removal field (0.005 MPa, 20 Hz) 1 sec. 2 sec. 5 sec. 10 sec. Charge removal width W (mm in) CPM Center + L - W Charge removal field (0.005 MPa, 50 Hz) Charge removal width W (mm in) 250 9.843 200 7.874 150 5.906 100 3.937 50 1.969 0 Charge removal field (airless, 20 Hz) Charge removal width W (mm in) Charge removal width W (mm in) Charge removal field (airless, 50 Hz) -50 -1.969 -100 -3.937 -150 -5.906 -200 -7.874 -250 -9.843 0 50 100 150 200 250 300 350 1.969 3.937 5.906 7.874 9.843 11.811 13.780 Charge removal distance L (mm in) 250 9.843 200 7.874 150 5.906 100 3.937 50 CPM 1.969 Center 0 + L -50 - W -1.969 -100 -3.937 1 sec. -150 2 sec. -5.906 5 sec. -200 10 sec. -7.874 -250 50 100 150 200 250 300 350 -9.843 0 1.969 3.937 5.906 7.874 9.843 11.811 13.780 Charge removal distance L (mm in) Charge removal field (0.5 MPa, 50 Hz) STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS 250 CPM 9.843 200 Center + 7.874 150 L - W 5.906 100 3.937 50 1.969 0 0.5 sec. 1 sec. 2 sec. 5 sec. 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) MACHINE VISION SYSTEMS Charge removal field (0.5 MPa, 20 Hz) Charge removal width W (mm in) Charge removal width W (mm in) MEASUREMENT SENSORS FA COMPONENTS ER-X001 -50 -1.969 -100 -3.937 -150 -5.906 -200 -7.874 -250 -9.843 0 FIBER SENSORS UV CURING SYSTEMS 250 CPM 9.843 200 Center + 7.874 150 L - W 5.906 100 3.937 50 1.969 0 -50 -1.969 -100 -3.937 -150 -5.906 -200 -7.874 -250 -9.843 0 Selection Guide Static Removers Pulse Air-gun 0.5 sec. 1 sec. 2 sec. 5 sec. Cleaning Box 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) Electrostatic Sensor ER-X ER-TF ER-X008 8 6 CPM Center 4 L 2 0 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) Airless 0.005 MPa 0.1 MPa 0.3 MPa 0.5 MPa 8 6 CPM Center 4 L 2 0 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) 300 11.811 200 7.874 100 3.937 CPM Center + L - W 0 -100 -3.937 -200 -7.874 -300 -11.811 0 1 sec. 2 sec. 5 sec. 10 sec. 50 100 150 200 250 300 1.969 3.937 5.906 7.874 9.843 11.811 Charge removal distance L (mm in) Charge removal field (vertical direction, airless, 10 Hz) Charge removal width W (mm in) Airless 0.005 MPa 0.1 MPa 0.3 MPa 0.5 MPa 10 Charge removal field (vertical direction, airless, 50 Hz) Charge removal width W (mm in) Charge removal time (sec.) 10 Correlation between charge removal distance and charge removal time (10 Hz) Charge removal time (sec.) Correlation between charge removal distance and charge removal time (50 Hz) ER-F 200 7.874 100 3.937 0 Center -200 -7.874 -300 -11.811 0 ER-VW ER-Q 300 11.811 -100 -3.937 ER-VS02 CPM + L - W 1 sec. 2 sec. 5 sec. 10 sec. 50 100 150 200 250 300 1.969 3.937 5.906 7.874 9.843 11.811 Charge removal distance L (mm in) 1167 0 -100 -3.937 -200 -7.874 -300 -11.811 0 SENSOR OPTIONS PLC 10 400 300 ER-X064 ER-X048 ER-X032 ER-X016 200 100 0 ENERGY MANAGEMENT SOLUTIONS UV CURING SYSTEMS Selection Guide Static Removers Pulse Air-gun Cleaning Box Electrostatic Sensor 0.1 0.2 0.3 0.4 6 CPM Center L 4 2 0 0.5 Airless 0.005 MPa 0.1 MPa 0.3 MPa 0.5 MPa 8 Applied pressure (MPa) -100 -3.937 1 sec. 2 sec. 5 sec. 10 sec. -200 -7.874 200 7.874 100 3.937 0 Center -100 -3.937 1 sec. 2 sec. 5 sec. 10 sec. -200 -7.874 -300 -11.811 0 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) CPM + L - W 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) Correlation between charge removal distance and charge removal time (10 Hz) 10 200 400 600 800 1,000 1,200 1,400 1,600 7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992 Charge removal distance L (mm in) Airless 0.005 MPa 0.1 MPa 0.3 MPa 0.5 MPa 8 6 CPM Center L 4 2 0 Correlation between charge removal distance and charge removal time (1 Hz) 10 200 400 600 800 1,000 1,200 1,400 1,600 7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992 Charge removal distance L (mm in) Airless 0.005 MPa 0.1 MPa 0.3 MPa 0.5 MPa 8 6 4 CPM Center L 2 0 200 400 600 800 1,000 1,200 1,400 1,600 7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992 Charge removal distance L (mm in) Common to ER-X016/X032/X048/X064 Charge removal field (horizontal direction, airless, 50 Hz) Charge removal width W (mm in) MACHINE VISION SYSTEMS 0 -300 -11.811 0 100 200 300 400 500 600 3.937 7.874 11.811 15.748 19.685 23.622 Charge removal distance L (mm in) Correlation between charge removal distance and charge removal time (50 Hz) HUMAN MACHINE INTERFACES FA COMPONENTS 1 sec. 2 sec. 5 sec. 10 sec. -200 -7.874 -300 -11.811 0 100 200 300 400 500 600 3.937 7.874 11.811 15.748 19.685 23.622 Charge removal distance L (mm in) Air flow Air flow [/min. (ANR)] LASER MARKERS -100 -3.937 100 3.937 300 11.811 Common to ER-X016/X032/X048/X064 MEASUREMENT SENSORS STATIC CONTROL DEVICES 0 CPM + L - W Charge removal time (sec.) WIRE-SAVING SYSTEMS 100 3.937 200 7.874 Center 500 19.685 400 15.748 300 11.811 200 7.874 100 3.937 0 -100 -3.937 -200 -7.874 -300 -11.811 -400 -15.748 -500 -19.685 0 CPM + Center - L W 1 sec. 2 sec. 5 sec. 10 sec. 100 200 300 400 500 600 3.937 7.874 11.811 15.748 19.685 23.622 Charge removal distance L (mm in) Charge removal field (horizontal direction, airless, 10 Hz) 500 19.685 400 15.748 300 11.811 200 7.874 100 3.937 0 -100 -3.937 -200 -7.874 -300 -11.811 -400 -15.748 -500 -19.685 0 CPM + Center L - W 1 sec. 2 sec. 5 sec. 10 sec. 100 200 300 400 500 600 3.937 7.874 11.811 15.748 19.685 23.622 Charge removal distance L (mm in) Charge removal field (horizontal direction, airless, 1 Hz) 500 19.685 400 15.748 300 11.811 200 7.874 100 3.937 Center 0 -100 -3.937 -200 -7.874 -300 -11.811 -400 -15.748 -500 -19.685 0 CPM + L - W 1 sec. 2 sec. 5 sec. 10 sec. 100 200 300 400 500 600 3.937 7.874 11.811 15.748 19.685 23.622 Charge removal distance L (mm in) Charge removal field (horizontal direction, 0.005 MPa, 50 Hz) Charge removal width W (mm in) SIMPLE WIRE-SAVING UNITS 1 sec. 2 sec. 5 sec. 10 sec. 200 7.874 300 11.811 Charge removal field (vertical direction, 0.5 MPa, 10 Hz) Charge removal width W (mm in) 100 3.937 CPM Center + L - W Charge removal width W (mm in) PARTICULAR USE SENSORS 200 7.874 300 11.811 Charge removal time (sec.) INDUCTIVE PROXIMITY SENSORS CPM Center + L - W Charge removal field (vertical direction, 0.5 MPa, 50 Hz) Charge removal width W (mm in) PRESSURE / FLOW SENSORS 300 11.811 Charge removal field (vertical direction, 0.005 MPa, 10 Hz) Charge removal width W (mm in) SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Charge removal field (vertical direction, 0.005 MPa, 50 Hz) Charge removal time (sec.) AREA SENSORS ER-X008 Charge removal width W (mm in) MICRO PHOTOELECTRIC SENSORS Please contact our office for details on data that is not listed here. Measured using a 150 x 150 mm 5.906 x 5.906 in CPM (charge plate monitor). (At center of CPM) Charge removal width W (mm in) PHOTOELECTRIC SENSORS ER-X SERIES CHARGE REMOVAL CHARACTERISTICS (TYPICAL) FIBER SENSORS LASER SENSORS Area Ionizer 500 19.685 400 15.748 300 11.811 200 7.874 100 3.937 0 -100 -3.937 -200 -7.874 -300 -11.811 -400 -15.748 -500 -19.685 0 CPM + Center L - W 1 sec. 2 sec. 5 sec. 10 sec. 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) ER-X ER-F 500 19.685 400 15.748 300 11.811 200 7.874 100 3.937 0 -100 -3.937 -200 -7.874 -300 -11.811 -400 -15.748 -500 -19.685 0 CPM + Center L - W 1 sec. 2 sec. 5 sec. 10 sec. 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) Charge removal field (horizontal direction, 0.005 MPa, 1 Hz) 500 19.685 400 15.748 300 11.811 200 7.874 CPM 100 + 3.937 Center 0 W - L -100 -3.937 -200 -7.874 1 sec. -300 2 sec. -11.811 5 sec. -400 10 sec. -15.748 -500 200 400 600 800 1,000 -19.685 0 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) Charge removal field (horizontal direction, 0.5 MPa, 50 Hz) 500 19.685 400 15.748 300 11.811 200 7.874 100 3.937 0 -100 -3.937 -200 -7.874 -300 -11.811 -400 -15.748 -500 -19.685 0 CPM + Center L - W 0.5 sec. 1 sec. 2 sec. 200 400 600 800 1,000 1,200 1,400 1,600 7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992 Charge removal distance L (mm in) Charge removal field (horizontal direction, 0.5 MPa, 10 Hz) Charge removal width W (mm in) ER-Q Charge removal field (horizontal direction, 0.005 MPa, 10 Hz) Charge removal width W (mm in) ER-VW Common to ER-X016/X032/X048/X064 Charge removal width W (mm in) ER-VS02 Charge removal width W (mm in) ER-TF 500 19.685 400 15.748 300 11.811 200 7.874 100 3.937 0 -100 -3.937 -200 -7.874 -300 -11.811 -400 -15.748 -500 -19.685 0 CPM + Center L - W 0.5 sec. 1 sec. 2 sec. 200 400 600 800 1,000 1,200 1,400 1,600 7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992 Charge removal distance L (mm in) Area Ionizer CHARGE REMOVAL CHARACTERISTICS (TYPICAL) ER-X SERIES 1168 Please contact our office for details on data that is not listed here. LASER SENSORS Measured using a 150 x 150 mm 5.906 x 5.906 in CPM (charge plate monitor). (At center of CPM) -100 -3.937 -200 -7.874 -300 -11.811 -400 -15.748 -500 -19.685 0 CPM + L - W 0.5 sec. 1 sec. 2 sec. 200 400 600 800 1,000 1,200 1,400 1,600 7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992 Charge removal distance L (mm in) 500 19.685 400 15.748 300 11.811 200 7.874 100 3.937 0 -100 -3.937 -200 -7.874 -300 -11.811 -400 -15.748 -500 -19.685 0 Center CPM + L - W 1 sec. 2 sec. 5 sec. 10 sec. 100 200 300 400 500 600 3.937 7.874 11.811 15.748 19.685 23.622 Charge removal distance L (mm in) Charge removal field (vertical direction, airless, 10 Hz) 500 19.685 400 15.748 300 11.811 200 7.874 100 3.937 0 -100 -3.937 -200 -7.874 -300 -11.811 -400 -15.748 -500 -19.685 0 Center CPM + L - W 1 sec. 2 sec. 5 sec. 10 sec. 100 200 300 400 500 600 3.937 7.874 11.811 15.748 19.685 23.622 Charge removal distance L (mm in) Charge removal field (vertical direction, airless, 1 Hz) Charge removal width W (mm in) 500 19.685 400 15.748 300 11.811 200 7.874 100 3.937 Center 0 Charge removal field (vertical direction, airless, 50 Hz) Charge removal width W (mm in) Charge removal width W (mm in) Charge removal field (horizontal direction, 0.5 MPa, 1 Hz) PHOTOELECTRIC SENSORS ER-X032 Charge removal width W (mm in) Common to ER-X016/X032/X048/X064 500 19.685 400 15.748 300 11.811 200 7.874 100 3.937 0 -100 -3.937 -200 -7.874 -300 -11.811 -400 -15.748 -500 -19.685 0 1 sec. 2 sec. 5 sec. 10 sec. Center SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS CPM + L - W INDUCTIVE PROXIMITY SENSORS 100 200 300 400 500 600 3.937 7.874 11.811 15.748 19.685 23.622 Charge removal distance L (mm in) 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) -100 -3.937 -200 -7.874 -300 -11.811 -400 -15.748 -500 -19.685 0 CPM Center + L - W 1 sec. 2 sec. 5 sec. 10 sec. 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) 500 19.685 400 15.748 300 11.811 200 7.874 CPM 100 3.937 Center + 0 L - W -100 -3.937 -200 -7.874 1 sec. -300 2 sec. -11.811 5 sec. -400 10 sec. -15.748 -500 -19.685 0 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) Charge removal field (vertical direction, 0.5 MPa, 50 Hz) Charge removal width W (mm in) 1 sec. 2 sec. 5 sec. 10 sec. 500 19.685 400 15.748 300 11.811 200 7.874 100 3.937 0 Charge removal field (vertical direction, 0.005 MPa, 1 Hz) Charge removal width W (mm in) CPM Center + L - W Charge removal width W (mm in) 500 19.685 400 15.748 300 11.811 200 7.874 100 3.937 0 -100 -3.937 -200 -7.874 -300 -11.811 -400 -15.748 -500 -19.685 0 CPM Center + L - W SENSOR OPTIONS CPM Center + L - W 0.5 sec. 1 sec. 2 sec. 200 400 600 800 1,000 1,200 1,400 1,600 7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992 Charge removal distance L (mm in) 500 19.685 400 15.748 300 11.811 200 7.874 100 3.937 0 -100 -3.937 -200 -7.874 -300 -11.811 -400 -15.748 -500 -19.685 0 Center CPM + L - W 0.5 sec. 1 sec. 2 sec. 200 400 600 800 1,000 1,200 1,400 1,600 7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992 Charge removal distance L (mm in) Charge removal field (vertical direction, airless, 50 Hz) 800 31.496 600 23.622 400 15.748 200 7.874 CPM Center + L - W 0 -200 -7.874 -400 -15.748 -600 -23.622 -800 -31.496 0 MEASUREMENT SENSORS STATIC CONTROL DEVICES PLC 0.5 sec. 1 sec. 2 sec. 200 400 600 800 1,000 1,200 1,400 1,600 7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992 Charge removal distance L (mm in) HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS 1 sec. 2 sec. 5 sec. 10 sec. 100 200 300 400 500 600 3.937 7.874 11.811 15.748 19.685 23.622 Charge removal distance L (mm in) Charge removal field (vertical direction, airless, 10 Hz) Charge removal width W (mm in) 500 19.685 400 15.748 300 11.811 200 7.874 100 3.937 0 Charge removal field (vertical direction, 0.5 MPa, 1 Hz) Charge removal width W (mm in) Charge removal field (vertical direction, 0.5 MPa, 10 Hz) WIRE-SAVING SYSTEMS LASER MARKERS ER-X064 Charge removal width W (mm in) Charge removal width W (mm in) 500 19.685 400 15.748 300 11.811 200 7.874 100 3.937 0 Charge removal field (vertical direction, 0.005 MPa, 10 Hz) ER-X032 Charge removal width W (mm in) PARTICULAR USE SENSORS SIMPLE WIRE-SAVING UNITS Charge removal field (vertical direction, 0.005 MPa, 50 Hz) -100 -3.937 -200 -7.874 -300 -11.811 -400 -15.748 -500 -19.685 0 MICRO PHOTOELECTRIC SENSORS AREA SENSORS ER-X032 -100 -3.937 -200 -7.874 -300 -11.811 -400 -15.748 -500 -19.685 0 FIBER SENSORS 800 31.496 600 23.622 400 15.748 200 7.874 CPM Center + L - W 0 -200 -7.874 -400 -15.748 -600 -23.622 -800 -31.496 0 MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Static Removers 1 sec. 2 sec. 5 sec. 10 sec. 100 200 300 400 500 600 3.937 7.874 11.811 15.748 19.685 23.622 Charge removal distance L (mm in) Pulse Air-gun Cleaning Box Electrostatic Sensor ER-X ER-TF ER-X064 -200 -7.874 -400 -15.748 -600 -23.622 -800 -31.496 0 Center CPM + L - W 1 sec. 2 sec. 5 sec. 10 sec. 100 200 300 400 500 600 3.937 7.874 11.811 15.748 19.685 23.622 Charge removal distance L (mm in) Center CPM + L - W 0 -200 -7.874 -400 -15.748 -600 -23.622 -800 -31.496 0 1 sec. 2 sec. 5 sec. 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) 800 31.496 600 23.622 400 15.748 200 7.874 Center CPM + L - W 0 -200 -7.874 -400 -15.748 -600 -23.622 -800 -31.496 0 1 sec. 2 sec. 5 sec. 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) Charge removal field (vertical direction, 0.005 MPa, 1 Hz) Charge removal width W (mm in) 0 800 31.496 600 23.622 400 15.748 200 7.874 Charge removal field (vertical direction, 0.005 MPa, 10 Hz) Charge removal width W (mm in) 800 31.496 600 23.622 400 15.748 200 7.874 Charge removal field (vertical direction, 0.005 MPa, 50 Hz) Charge removal width W (mm in) Charge removal width W (mm in) Charge removal field (vertical direction, airless, 1 Hz) 800 31.496 600 23.622 400 15.748 200 7.874 Center CPM + L - W 0 -200 -7.874 -400 -15.748 -600 -23.622 -800 -31.496 0 1 sec. 2 sec. 5 sec. 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) ER-VS02 ER-VW ER-Q ER-F 1169 INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS WIRE-SAVING SYSTEMS -200 -7.874 -400 -15.748 -600 -23.622 -800 -31.496 0 80 ENERGY MANAGEMENT SOLUTIONS Air flow [/min. (ANR)] STATIC CONTROL DEVICES HUMAN MACHINE INTERFACES 200 400 600 800 1,000 1,200 1,400 1,600 7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992 Charge removal distance L (mm in) 800 31.496 600 23.622 400 15.748 200 7.874 Center CPM + L - W 0 -200 -7.874 -400 -15.748 -600 -23.622 -800 -31.496 0 0.5 sec. 1 sec. 2 sec. 200 400 600 800 1,000 1,200 1,400 1,600 7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992 Charge removal distance L (mm in) ER-X008HC Air flow 100 PLC 0.5 sec. 1 sec. 2 sec. Common to ER-XHC MEASUREMENT SENSORS LASER MARKERS CPM + L - W 0 SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Center 10 60 40 20 8 Airless 0.005 MPa 0.05 MPa 0.1 MPa 6 4 2 800 31.496 600 23.622 400 15.748 200 7.874 0 -200 -7.874 -400 -15.748 -600 -23.622 -800 -31.496 0 0.02 0.04 0.06 0.08 Applied pressure (MPa) 0.1 0 CPM + L - W 0.5 sec. 1 sec. 2 sec. 200 400 600 800 1,000 1,200 1,400 1,600 7.874 15.748 23.622 31.496 39.370 47.244 55.118 62.992 Charge removal distance L (mm in) CPM Center Correlation between charge removal distance and charge removal time (30 Hz) 10 8 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) Airless 0.005 MPa 0.05 MPa 0.1 MPa 6 4 2 CPM Center L L 0 Center ER-X016HC Correlation between charge removal distance and charge removal time (30 Hz) ER-X064HC ER-X048HC ER-X032HC ER-X016HC ER-X008HC Charge removal field (vertical direction, 0.5 MPa, 1 Hz) Charge removal width W (mm in) PRESSURE / FLOW SENSORS 800 31.496 600 23.622 400 15.748 200 7.874 Charge removal field (vertical direction, 0.5 MPa, 10 Hz) Charge removal time (sec.) SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Charge removal field (vertical direction, 0.5 MPa, 50 Hz) Charge removal width W (mm in) AREA SENSORS ER-X064 Charge removal time (sec.) MICRO PHOTOELECTRIC SENSORS Please contact our office for details on data that is not listed here. Measured using a 150 x 150 mm 5.906 x 5.906 in CPM (charge plate monitor). (At center of CPM) Charge removal width W (mm in) PHOTOELECTRIC SENSORS ER-X SERIES CHARGE REMOVAL CHARACTERISTICS (TYPICAL) FIBER SENSORS LASER SENSORS Area Ionizer 0 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Charge removal distance L (mm in) FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Static Removers Pulse Air-gun Cleaning Box Electrostatic Sensor ER-X ER-TF ER-VS02 ER-VW ER-Q ER-F Please contact our office for details on data that is not listed here. Area Ionizer ER-X SERIES 1170 I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS New-type controller (produced from April 2014 on) LASER SENSORS Notice:Products manufactured from April 2014 and before April 2016 cannot be used with the high and low temperature resistant type head ER-X008HC. For the Identification of previous-type and new-type controllers and for the combination with the head, refer to p.1171. PHOTOELECTRIC SENSORS 2 3 4 5 6 7 8 9 10 6 7 4 (Front view) Housing: 5569-10A [Manufactured by Molex] Terminal No. 1 2 Terminal name 3 Note:Color code refers to cable colors of an optional power supply cable. 9 10 3 8 1 Color code 0V Blue COM(-) - Discharge Pink control input COM(OUT) Violet F.G. terminal Green / Yellow 24 V Brown COM(+) - COM(IN) White Alarm output Orange Error output Black 4 5 6 7 8 9 10 Main circuit 1 When connecting the output to negative common (Brown) +V Internal circuit 6 COM(+) (Violet) COM (OUT) 7 *1 8 3 (Orange) Alarm output Load + - (Black) Error output Load (Pink) Discharge control input (White) COM (IN) 24 V DC 10 % (Blue) 0 V (Green/Yellow) F.G. User's circuit 9 10 4 COM() 2 5 When connecting the output to positive common Main circuit Power connector terminal arrangement 1 2 Be sure to ground. 5 Internal circuit *1 (Brown) +V AREA SENSORS COM(+) (White) COM (IN) (Pink) Discharge control input (Orange) Alarm output (Black) Error output (Violet) COM (OUT) Load *2 + - 24 V DC 10 % Be sure to ground. SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Non-voltage contact or NPN open-collector transistor or WIRE-SAVING SYSTEMS MEASUREMENT SENSORS or Contact "closed" or transistor ON: Discharge halt Contact "open" or transistor OFF: Starting discharge STATIC CONTROL DEVICES Contact "closed" or transistor ON: Discharge halt Contact "open" or transistor OFF: Starting discharge Notes: 1) Be sure to ground the F.G. terminal. If F.G. terminal is not connected properly, it may cause electric shock. In the case of ER-X001, the head mounting bracket and F.G. terminal are internally connected. 2) To stop discharge, turn ON the discharge control input for 20 ms or longer. To start discharge, turn OFF (open) the discharge control input. Discharge will start in 20 ms. Notice: Products manufactured before March 2014 cannot be used with ER-X001, ER-X008 and the high and low temperature resistant type head ER-XHC. For the Identification of previous-type and new-type controllers and for the combination with the head, refer to p.1171. 3 4 5 8 9 10 7 4 (Front view) Housing: 5569-10A [Manufactured by Molex] Terminal No. 1 2 3 4 5 6 7 8 9 10 Terminal name Note:Color code refers to cable colors of an optional power supply cable. 10 3 1 Color code 0V Blue COM(-) - Discharge Pink control input COM(OUT) Violet F.G. terminal Green / Yellow 24 V Brown COM(+) - - White Alarm output Orange Error output Black 9 2 5 Internal circuit When connecting the output to positive common (Brown) +V COM(+) (Violet) COM (OUT) (Orange) Alarm output Load (Black) Error output Load (Pink) Discharge control input 6 7 *1 3 + - 24 V DC 10 % Main circuit 2 7 Main circuit 1 6 When connecting the output to negative common 6 9 10 4 (Blue) 0 V 1 COM() (Green/Yellow) F.G. User's circuit LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS Previous-type controller (produced before March 2014) Power connector terminal arrangement PRESSURE / FLOW SENSORS PARTICULAR USE SENSORS COM() *2 Non-voltage contact or PNP open-collector transistor SAFETY LIGHT CURTAINS / SAFETY COMPONENTS INDUCTIVE PROXIMITY SENSORS Load (Blue) 0 V (Green/Yellow) F.G. User's circuit MICRO PHOTOELECTRIC SENSORS 2 5 Be sure to ground. *1 Internal circuit (Brown) +V FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS COM(+) (Pink) Discharge control input (Orange) Alarm output (Black) Error output (Violet) COM (OUT) Load *2 + - 24 V DC 10 % Load (Blue) 0 V Static Removers Pulse Air-gun COM() (Green/Yellow) F.G. User's circuit Selection Guide Be sure to ground. Cleaning Box Electrostatic Sensor *2 Non-voltage contact or PNP open-collector transistor Non-voltage contact or NPN open-collector transistor ER-X ER-TF ER-VS02 or Contact "closed" or transistor ON: Discharge halt Contact "open" or transistor OFF: Starting discharge or Contact "closed" or transistor ON: Discharge halt Contact "open" or transistor OFF: Starting discharge Notes: 1) Be sure to ground the F.G. terminal. If F.G. terminal is not connected properly, it may cause electric shock. 2) To stop discharge, turn ON the discharge control input for 20 ms or longer. To start discharge, turn OFF (open) the discharge control input. Discharge will start in 20 ms. ER-VW ER-Q ER-F 1171 FIBER SENSORS Area Ionizer PRECAUTIONS FOR PROPER USE LASER SENSORS * Never use this product as device for personnel protection. * In case of using devices for personnel protection, use products which meet laws or standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. * This product produces high voltages. * Do not use this product in places where there may be a danger of flammable or combustible items being present. * To prevent electric shock and to conduct proper discharge, be sure to ground a frame ground (F.G.) terminal of a controller. * Do not place hands near the discharge needle. Doing so may cause electric shock. * Since the tip of the discharge needle is sharp, take sufficient care in handling the discharge needle, or injuries may result. * The high-voltage cable between the head and the highvoltage unit must be fixed and the minimum bend radius is less than R30 mm R1.181 in. In case of using at the bend radius R30 mm R1.181 in or less and using at moving part may cause fire and break down, etc. of the high-voltage cable. * Clean the discharge needle regularly (about once a week). Otherwise, optimum charge removal performance may not be achieved, and accidents or operating problems may occur. * If this product is used in a confined space, ozone emitted from this product may be detrimental. Be sure to provide ventilation. * Do not direct ionized air toward the face. Ozone may cause irritation to places such as the nose and throat. * When the product has been used under very high or low temperatures, do not touch the product with a bare hand. Failure to observe this caution can result in burn or injury. Be sure to let the product cool sufficiently when touching the product for maintenance or other purposes. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS ER-X SERIES * NRTL (National Recognized Testing Laboratories) certification means that the product was tested by the third-party private testing organization (TUV SUD America) authorized by the Occupational Safety and Health Administration (OSHA) and found to comply with the safety standards (ANSI/UL) established by American National Standards Institute and the standards (CAN/CSA) established by Canadian Standards Association. Refer to p.1595 for general precautions. * When using as a CSA and UL compliant product, use a CLASS 2 CSA/ UL certified power supply, or a CSA/UL certified power supply that has been evaluated as a Limited Power Source as specified in CAN/ CSA-C22.2 No.60950-1/UL60950-1. * This product has been developed / produced for industrial use only. * Do not use this product for purposes other than electric charge removal. * Do not use this product in environments which are outside the specification range, otherwise operating problems or damage may occur. In addition, the operating life of the product may become significantly reduced. * This product is a precision device. Do not apply a shock to it by dropping, for example. Accidents or operating problems may occur. * Never disassemble, repair or modify this product. Accidents or operating problems may occur. * Do not throw this product in fire. It may explode or toxic fumes may be generated. * Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. * Verify that the supply voltage variation is within the rating. * In case using switching regulator, be sure to connect F.G. terminal. * When connecting / removing the head or performing wiring or inspection work, be sure to turn off the power first. Not doing so may result in accidents, electric shock or operating problems. * After connecting the cables, check that the connections are correct before turning on the power. If the cables are connected incorrectly, operating problems or accidents may occur. * Do not use a cable with any damage such as cracks or splitting. Risk of accidents and failure. * Avoid use in a location with significant steam or dust, or in a location where the product may come in direct contact with water, oil, or welding spatter. * Do not touch the discharge needle with hard objects such as tools. If the discharge needle becomes broken, it will not provide sufficient charge removal performance, and moreover operating problems or accidents may occur. * During installation, fasten the product securely. If it is not securely fastened or it is subjected to continuous vibration or shock, accidents or operating problems may result. * Power cable that are 0.15mm2 or more and 30 m 98.425 ft or less in total length for wiring. Also, keep the wiring as short as possible in order to prevent noise. * When disposing of this product, treat it appropriately as industrial waste. * After starting discharge, it takes 30 minutes approx. for charge removal performance to stabilize. Therefore, wait 30 minutes before adjusting ion balance. * Use the correct combination of head, discharge needle unit and controller. Identification of previous-type and new-type controllers and combination with the head New-type controller (Note) Previous-type controller (Note) Produced from April Produced from April 2014 Produced before March 2014 2016 on and before April 2016 Selection Guide Static Removers Pulse Air-gun Cleaning Box * Front nameplate Front nameplate Combination Electrostatic Sensor ER-X ER-TF * Front nameplate ER-XC02 ER-XC02 DSC DSC CHECK CHECK 1 + + 0 0 * Bottom nameplate Bottom nameplate mark indicated ER-VS02 ER-X001 ER-X008 ER-X016 Bar type ER-X032 ER-X048 ER-X064 ER-X008HC High and Low ER-X016HC temperature ER-X032HC resistant ER-X048HC ER-X064HC Spot type ER-VW ER-Q ER-F Head ERROR ERROR HEAD OK HEAD 2 Change of front nameplate design * Bottom nameplate mark not indicated OK HEAD 1 + + 0 0 HEAD 2 * Bottom nameplate mark not indicated Cannot be used Cannot be used OK OK OK Cannot be used OK OK Cannot be used Note:The layout of the power supply connector pins differ between new-type controllers and previous-type controllers. For details refer to "I/O CIRCUIT AND WIRING DIAGRAMS" (p.1170). Area Ionizer PRECAUTIONS FOR PROPER USE Mounting ER-X SERIES 1172 Refer to p.1595 for general precautions. LASER SENSORS Controller installation Angle adjustment screw Head installation M4 * Using two M4 screws or one M6 screw, screw mount the head onto the equipment housing. * Loosen the angle adjustment screw, Angle adjustment screw adjust the head angle, and then fasten the head with the tightening torque of 0.5 Nm M6 screw or less. * Position the head mounting bracket of the M4 screw ER-X001 at least 20 mm 0.787 in away Head from the tip of the head. The tightening fixing torque for the head fixing screw must be screw 0.5 Nm or less. * After mounting and setting up the head, set the controller according to the procedures described in the instruction manual in order to properly remove electrical charge. Notes: 1) Be sure to ground the equipment housing onto which the head is mounted. 2) The distance between the head and the charge removing object should be 30 mm 1.181 in or more. If the static buildup of the charge removing object is 30 kV or more, set the distance to 50 mm 1.969 in or more. 3) If there is metal near the head or between the head and the charge removing object, ion is absorbed, hindering appropriate static removal. Install the head under the following installation condition. 4) In case using the side mounting, the discharge frequency should be 10 Hz or more. * Back-side mounting (All frequencies) * Side mounting (10 Hz or more) Surrounding 50 mm Surrounding * Mounting of ER-X001 50 mm metal 1.969 in or more metal 1.969 in or more The discharge muzzle must exceed this line (surrounding metal.) 20 mm 0.787 in or more 20 mm 0.787 in or more 5)When installing two or more heads set the same frequency and keep the distance as below. In face to face or parallel using different frequency, keep the distance between the heads 400 mm 15.748 in or more. When installing the heads face to face, install heads in distance that the heads can perform the charge removal of a side of the object individualy. * Mount the controller on a 35 mm 1.378 in width DIN rail or using M4 screws. Lock release lever * Pull the lock release lever to remove this product from the DIN rail. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS 35 mm 1.378 in width DIN rail * The tightening torque should be 1.2 Nm or less. SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS M4 screw PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Piping * Air supplied to this product will reduce contamination of the discharge needle and improve the charge removal speed. * The outer diameter of the air tube to fit to the air inlet portion of this product should be o6 mm o0.236 in. * Make sure that clean air (air containing no water, no oil and no dust) should be supplied. * Since the pressure will drop when the air piping from the main pressure supply is extended or pneumatic components (e.g., needle valve, speed controller, mini filter) are added, keep an eye on the pressure supply to the ionizer making sure it is not in short supply. For the pneumatic components, select those that can accommodate the air supply flow rate. ER-X008/X016/X032/X048/X064 Head section Air inlet WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS * Face-to-face installation 100 mm 3.937 in or more FIBER SENSORS o6 mm o0.236 in tube 100 mm 3.937 in or more 11.4 mm 0.449 in ER-X008HC/X016HC/X032HC/X048HC/X064HC * Parallel installation o6 mm o0.236 in heat-resistant tube Head section Selection Guide Static Removers Pulse Air-gun Cleaning Box Electrostatic Sensor 50 mm 1.969 in or more 50 mm 1.969 in or more o6 o0.236-4 air tube joint ER-X High-voltage unit installation * Use two M4 screws or two M6 screws to fasten the head. The tightening torques for fastening, are as follows. * When using M4 screws: 1.2 N*m * When using M6 screws: 2.5 N*m ER-TF Insert all the way M6 screw M4 screw Notes: 1)Do not place any objects on top of the high-voltage unit. 2)When using multiple heads, keep the distance of at least 10 mm 0.394 in between the high-voltage units. 10 mm 3)When fastening the high-voltage 0.394 in unit using M6 screws, fasten before or more connecting the head connection cable. 4)Use M6 screws for the installation of the high-voltage unit of the ER-X001. 5)The minimum bending radius of the high-voltage cable is R30 mm R1.181 in. ER-VS02 ER-X001 ER-VW High-voltage unit ER-Q ER-F o6 mm o0.236 in tube Air inlet (11.6 mm 0.457 in) Note:After inserting the tube into the joint of this product, always make sure that the tube is all the way in and securely inserted. Insufficient tube insertion will cause air leakage. 1173 FIBER SENSORS LASER SENSORS Area Ionizer ER-X SERIES DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. ER-X008/X016/X032/X048/X064 Head PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS 6 0.236 2-o6.5 o0.256 17 mounting holes 0.669 28 1.102 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS 180 7.087 160 6.299 2-o4.5 o0.177 mounting holes 5 0.197 PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS o6.9 o0.272 high-voltage cable 0.5 m 1.640 ft 18 0.709 38 1.496 18 0.709 35 1.378 162 6.378 28.4 1.118 (25 0.984) 12-pin connector STATIC CONTROL DEVICES LASER MARKERS 40 1.575 2-o6.5 o0.256 9.4 0.370 18 0.709 6.2 0.244 18 0.709 Head mounting bracket A B C D (E) ER-X008 40 1.575 106 4.173 138 5.433 150 5.906 163 6.417 ER-X016 120 4.724 194 7.638 226 8.898 238 9.370 251 9.882 ER-X032 280 11.024 354 13.937 386 15.197 398 15.669 411 16.181 ER-X048 440 17.323 514 20.236 546 21.496 558 21.969 571 22.480 ER-X064 600 23.622 674 26.535 706 27.795 718 28.268 731 28.780 Mounting drawing with discharge part protective cover (ER-XACVR) 18 0.709 Discharge part protective cover HUMAN MACHINE INTERFACES 45.7 1.799 15.7 0.618 ENERGY MANAGEMENT SOLUTIONS 159.6 6.283 (160 6.299) (F) FA COMPONENTS UV CURING SYSTEMS 22 0.866 30 1.181 Discharge needle unit Model No. PLC MACHINE VISION SYSTEMS D C Head mounting bracket 4.2 0.165 28.5 1.122 Clean air outlet (4 points) 4.2 0.165 9.4 0.370 6.2 0.244 9.4 0.370 A 40 1.575 (E) Details of a head mounting bracket WIRE-SAVING SYSTEMS MEASUREMENT SENSORS 6 0.236 192 7.559 B 9.5 0.374 Points of discharge needle ion air outlet 2-o6.5 o0.256 18 o12 o0.472 0.709 170 6.693 10.5 0.413 SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS 31 1.220 Joint for o6 o0.236 air tube 28.5 1.122 9.4 0.370 18 0.709 25.4 1.000 Model No. (F) ER-X016 159.6 6.283 ER-X032 319.6 12.583 ER-X048 479.6 18.882 ER-X064 639.6 25.181 Note: The ER-XACVR discharge part protective cover cannot be used on the ER-X008 or high and low temperature resistant type head ER-XHC. ER-X008HC/X016HC/X032HC/X048HC/X064HC Head Allowable ambient temperature: -60 to +200 C -76 to +392 F Selection Guide Static Removers Pulse Air-gun 6 0.236 2-o6.5 o0.256 17 mounting holes 0.669 28 1.102 Cleaning Box Electrostatic Sensor 9.4 0.370 1300 51.181 180 7.087 160 6.299 18 0.709 9.5 0.374 2-o4.5 o0.177 mounting holes 5 0.197 31 1.220 o6.9 o0.272 heat-resistant high-voltage cable (1.8 m 5.906 ft) 28.5 1.122 40 1.575 Points of discharge needle ion air outlet 38 1.496 18 0.709 ER-VS02 ER-VW ER-Q 35 1.378 170 6.693 10.5 0.413 162 6.378 (25 0.984) ER-F 192 7.559 12-pin connector Details of a head mounting bracket 2-o6.5 o0.256 9.4 0.370 18 0.709 6.2 0.244 4.2 0.165 2-o6.5 o0.256 18 o12 o0.472 0.709 28.4 1.118 9.4 0.370 6.2 6 0.236 0.244 9.4 0.370 6.9 0.272 A 40 1.575 28.5 1.122 10 0.394 Clean air outlet (4 points) ER-X ER-TF o6 o0.236-4 air tube joint (accessory) B (E) D C 4.2 0.165 Head mounting bracket Head mounting bracket Discharge needle unit Model No. A 4 0.157 30 1.181 B C D 22 0.866 18 0.709 (E) ER-X008HC 40 1.575 106 4.173 138 5.433 150 5.906 163 6.417 ER-X016HC 120 4.724 194 7.638 226 8.898 238 9.370 251 9.882 ER-X032HC 280 11.024 354 13.937 386 15.197 398 15.669 411 16.181 ER-X048HC 440 17.323 514 20.236 546 21.496 558 21.969 571 22.480 ER-X064HC 600 23.622 674 26.535 706 27.795 718 28.268 731 28.780 Area Ionizer DIMENSIONS (Unit: mm in) ER-X SERIES 1174 The CAD data can be downloaded from our website. ER-X001 Head o10.5 o0.413 high-voltage cable 1.2 m 3.937 ft long (internal air tube) 6 0.236 48 1.890 8.6 0.339 210 8.268 28.5 1.122 20 0.787 16 0.630 (17 0.669) 2-6.5 0.256 mounting holes 35 1.378 PHOTOELECTRIC SENSORS 6.2 0.244 AREA SENSORS MICRO PHOTOELECTRIC SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS (20.5 0.807) 70 2.756 44 1.732 Joint for o6 o0.236 air tube (360 rotatable) 38 1.496 18 0.709 210 8.268 10.5 0.413 o35 o1.378 o17 o13 o0.669 o0.512 25 0.984 6 0.236 25.4 1.000 21.5 0.846 165 6.496 o12 o0.472 PRESSURE / FLOW SENSORS PARTICULAR USE SENSORS 6 0.236 Discharge needle unit 8 0.315 Head mounting bracket (removable) 14 0.551 INDUCTIVE PROXIMITY SENSORS Mountable range 24 0.945 of head mounting bracket 18 0.709 SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Ion air outlet 222 8.740 ER-XC02 Controller 16 0.630 16 0.630 14 0.551 For head 2 44 1.732 Head connection connector S12B-PUDSS-1 [Manufactured by JST Mfg. Co., Ltd.] 9.3 0.336 5.2 0.205 6.5 0.256 7 0.276 9.1 0.358 Head connection cable o6 o0.236 * Length L L (9.1 0.358) 14 0.551 8.8 0.346 8.8 0.346 Model No. Length L ER-XCCJ2H 2,000 78.740 ER-XCCJ5H 5,000 196.850 10,000 ER-XCCJ10H 393.701 18 0.709 53 2.087 39 1.535 7 0.276 ER-XCCJH For head 1 10 0.394 ER-XCC Suitable for 35 mm 1.378 in width DIN rail 19.6 0.772 (103.5 4.075) 27.3 1.075 76 2.992 97 3.189 35.4 1.394 90 3.543 140 5.512 Power cable (Optional) o5.3 o0.209 22.2 0.874 * Length L L 14.4 0.567 ER-XAPS(-EX) 2-o5 o0.197 mounting holes Model No. Length L ER-XCC2 2,000 78.740 ER-XCC5 5,000 196.850 AC adapter (Optional) 14.4 0.567 Cable (22.2 0.874) 1.8 m 5.910 ft 60 2.362 16.5 0.650 Power supply connection connector 5569-10A [Manufactured by Molex] 9.2 0.362 23.2 0.913 (19.6 0.772) 28 1.102 WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS F.G. wire 3.7 m 12.139 ft 4 0.157 LASER SENSORS 12 0.472 M3 fixing screw 20 0.787 4.2 0.165 FIBER SENSORS AC cable 1.8 m 5.910 ft (Note) MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Static Removers Pulse Air-gun Cleaning Box Electrostatic Sensor 95.9 3.776 43.8 1.724 Note: The AC cable is not enclosed with ER-XAPS-EX. ER-X ER-TF ER-VS02 ER-VW ER-Q ER-F