• North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
• India Tel: +91.80.4155721 • China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and prod uct information.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
changes to the product(s) or information contained herein without notice.
2
Low Noise Amplifier, 28 dB Gain,
100 - 600 MHz
Rev. V3
AM-160
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
Commitment to produce in volume is not guaranteed.
Electrical Specifications: 2,3 TA = -55°C to +85°C Case Temperature
Parameter Test Conditions Units Min. Typ. Max.
Gain @+25oC dB
27.2
28.2 29.2
Frequency Response — dB
—
— ±1.25
Gain Variation with
Temperature — dB
— — ±1.0
1 dB Compression Output Power dBm
+16 —
—
Noise Figure — dB
—
—
3.0
Reverse Transmission — dB — -38 -32
VSWR — Ratio
Ratio —
— —
— 2.5:1
2:1
Output IP2 Two-Tone inputs up to +5 dBm dBm +36 — —
Output IP3 Two-Tone inputs up to +5 dBm dBm +27 — —
Vbias — VDC +14.5 +15.0 +15.5
Ibias Vbias = +15.0 VDC mA — 70 75
Power Dissipation @ +15 V Bias mW — 1050 —
Frequency
250 MHz
100 - 600 MHz
100 - 600 MHz
100 - 600 MHz
100 - 600 MHz
100 - 600 MHz
100 - 600 MHz
100 - 400 MHz
100 - 600 MHz
100 - 600 MHz
—
—
—
2. All specifications apply when operated at +15 VDC, with 50 ohms source and load impedance.
3. Heat Sinking: Operation at case temperature above 95°C is not recommended. Heat sinking adequate to dissipate 1.2 W must be pro-
vided in use.
Frequency
(MHz) S11
MAG/ANG S21
MAG/ANG S12
MAG/ANG S22
MAG/ANG
100 0.14/126.3 28.21/-5.6 0.01/-18.0
0.07/-73.4
150 0.12/56.7 28.30/-53.5 0.01/-68.5
0.08/-144.7
200 0.08/-15.5 27.45/-93.3 0.01/-108.2
0.09/150.5
250 0.17/-67.8 26.79/-126.3 0.01/-143.8
0.10/101.3
300 0.18/-87.7 25.37/-155.5
0.01/-178.1 0.12/64.4
350 0.18/-96.1 25.42/172.0
0.01/149.5 0.14/34.6
400 0.23/-115.4 24.92/141.7
0.02/120.6 0.11/4.7
500 0.27/175.5 25.67/78.7
0.02/59.1 0.10/-101.1
600 0.32/19.1 25.58/0.7 0.02/-14.6 0.24/143.7
S-Parameter Data