Think Automation and beyond...
IDEC Safety Interlock Switches
2
Interlock Switches
As increasingly more complex tasks are taken over by machines, it has become common for people and machines to
interact closely on a daily basis. In these human-machine interactions, it is critical that safety components are used as a
countermeasure to avoid injuries.
As machine safeguarding continues to evolve both in products and regulations, IDEC Corporation has created a family of
safety components to meet industry demands and needs. With six decades of experience in industrial automation, IDEC
continues to produce the same high-quality and globally-recognized products that can be relied upon for machine safety
control throughout the world.
To us, safety isn’t just about meeting safety requirements; it’s about protecting people and productivity.
IDEC Safety Components
Providing reliable, human-machine safety components
3
Interlock Switches
IDEC Safety Interlock Switch Family
Compact, High-Quality Designs
Often used for gate and door monitoring or locking, IDEC safety
interlock switches are created with a high-quality and compact
design aimed at achieving the ultimate goal of maximum
personnel safety.
When installed correctly in a safety circuit, IDEC HS safety
switches ensure that doors, gates and guards are closed
before a process or machine can start up. When the gate or
door is opened, the actuating key is removed from the switch
thus signaling a safety logic device.
Safety Made Simple
Simple to install, HS safety interlock switches feature metal or
plastic heads or bodies of different shapes, sizes and connection
methods to cover most safeguarding applications, while
complying with both domestic and European safety standards.
For some international standards, such as EN1088, applications
can only use proprietary actuators to prevent tampering of the
gate or door. HS switches are perfect for this, as they meet or
exceed all standards.
Variety to Choose From
Available in a variety of sizes, contact arrangements and
functions, IDEC HS safety interlock switches can be used in
a wide-range of safety system applications from machine
tools and semiconductor equipment to packaging and material
handling equipment.
IDEC Safety Components
www.IDEC.com/safety
800-262-IDEC
4
Selection
Basic Safety Interlock Switches
Subminiature - HS6B Miniature - HS5D Full Size - HS1B
30 x 15 x 78mm
2 or 3 contacts
Integrated cable
Plastic body
30 x 30 x 90mm
2 or 3 contacts
Screw termination
Metal or plastic head
52 x 35 x 125mm
2 contacts
Screw termination
Die-cast aluminum body
(page 5) (page 6) (page 7)
Solenoid Locking Safety Interlock Switches
Subminiature - HS6E Miniature - HS5E Full Size - HS1E Full Size - HS1C Full Size- HS1L
75 x 15 x 75mm
500N
5 contacts
Integrated cable
Plastic body
35 x 40 x 146mm
1400N
4 contacts
Integrated cable
Metal head, plastic body
104 x 35 x 129mm
1500N
3-4 contacts
Screw termination
Plastic body
106 x 35 x 125mm
1500N
3-4 contacts
Screw termination
Die-cast aluminum body
104 x 35 x 129mm
3000N
6 contacts
Screw termination
Plastic body
(page 8) (page 10) (page 12) (page 16) (page 14)
IDEC has a variety of gate/door switches to meet all your needs!
Subminiature HS6B
5
HS6B features:
Only 78 x 30 x 15mm•
Two actuator entrances provide flexibility for installation options•
Integral molded cable reduces wiring time•
IP67 (IEC60529) •
Direct Opening Action•
Actuators comply with ISO14119 and EN1088•
Part Numbers
Contact Configuration Cable
Length Part Number
1NC-1NO
3433
12
Zb
11
1m HS6B-11B01
3m HS6B-11B03
5m HS6B-11B05
2NC
3231
11
Zb
12
1m HS6B-02B01
3m HS6B-02B03
5m HS6B-02B05
2NC-1NO
3433
12
22
Zb
11
21
1m HS6B-12B01
3m HS6B-12B03
5m HS6B-12B05
3NC
31
21
11
Zb
32
22
12
1m HS6B-03B01
3m HS6B-03B03
5m HS6B-03B05
Standard stock items in bold.
Specifications
Conforming to
Standards
EN1088, IEC60947-5-1, EN60947-5-1, GS-ET-15, IEC60664-1,
IEC60204-1, EN60204-1, UL508, CSA C22.2 No. 14
Operating Temperature –25 to +70˚C (no freezing)
Storage Temperature –40 to +80˚C (no freezing)
Relative Humidity 45 to 85% (no condensation)
Storage Humidity 95% maximum (no condensation)
Rated Insulation
Voltage (Ui)300V
Degree of Protection IP67 (IEC60529)
Direct Opening Travel 8mm minimum
Direct Opening Force 60N minimum
Thermal Current (Ith) 2.5A
Rated Operating
Current (Ie)
Rated Voltage (Ue) 30V 125V 250V
AC Resistive load (AC-12) 2.5A 1.5A
Inductive load (AC-15) 1.5A 0.75A
DC
Resistive load (DC-12) 2.5A 1.1A 0.55A
(2A) (0.4)A (0.2A)
Inductive load (DC-13) 2.3A 0.55A 0.27A
(1A) (0.22A) (0.1A)
Operating Frequency 1200 operations/hour
Mechanical Life 1,000,000 operations (GS-ET-15)
Electrical Life 100,000 operations (at full rated load)
Weight 120g - 1m cable type, 270g - 3m cable type, 420g - 5m cable type
Dimensions (mm)
Slot Plug (Note 1)
(supplied)
(58)
R2.2
4
4
(ø7.6)
5.5
10.4
27.6
(9)
11
78
35
20
30
10.1
5.5
10.4
15
Interlock Switch
Actuator Keys
Appearance Part Number Shape
HS9Z-A61 Straight
HS9Z-A62 Right-angle
HS9Z-A65 Adjustable actuator
90° angle
HS9Z-A66 Adjustable actuator
180° angle
Actuators are not included and must be ordered separately.
Subminiature HS6B
6
HS5D features:
Detects detachment of head for enhanced safety•
Compact dimensions with up to three contacts•
The head orientation can be rotated, allowing 8 different actuator entries•
NC contacts with direct opening action (IEC/EN60947-5-1)•
M3 terminal screws for easy wiring•
Gold-plated co• ntacts suitable for small loads
Part Numbers
Contact Configuration Gland Port
Size
Plastic Head
Type
Metal Head
Type
1NC-1NO
Main Circuit
Monitor Circuit
1211
23 24
Zb
G1/2 HS5D-11RN HS5D-11ZRN
PG13.5 HS5D-11RNP HS5D-11ZRNP
M20 HS5D-11RNM HS5D-11ZRNM
2NC
Main Circuit
Monitor Circuit
11 12
2221
Zb
G1/2 HS5D-02RN HS5D-02ZRN
PG13.5 HS5D-02RNP HS5D-02ZRNP
M20 HS5D-02RNM HS5D-02ZRNM
2NC-1NO
1211
21 22
33 34
Zb
Main Circuit
Main Circuit
Monitor Circuit
G1/2 HS5D-12RN HS5D-12ZRN
PG13.5 HS5D-12RNP HS5D-12ZRNP
M20 HS5D-12RNM HS5D-12ZRNM
3NC
11 12
21 22
3231
Zb
Main Circuit
Main Circuit
Monitor Circuit
G1/2 HS5D-03RN HS5D-03ZRN
PG13.5 HS5D-03RNP HS5D-03ZRNP
M20 HS5D-03RNM HS5D-03ZRNM
Standard stock items in bold.
Actuator Keys & Accessories
Item Part Number Description
HS9Z-A51 Straight
HS9Z-A51A Straight w/rubber
bushings
HS9Z-A52 Right-angle
HS9Z-A52A Right-angle w/rubber
bushings
HS9Z-A55 Angle Adjustable
(vertical/horizontal)
HS9Z-A5P Plug Actuator
HS9Z-SH5 Sliding Actuator
HS9Z-PH5 Padlock Hasp
Actuators are not included and must be ordered separately.
Specifications
Conforming to Standards
ISO14119, EN1088, IEC60947-5-1, EN60947-5-1 (TÜV approval),
GS-ET-15 (TÜV approval), UL508, CSA C22.2 No. 14,
GB14048.5 (CCC approval), IEC60204-1/EN60204-1 (applicable
standards for use)
Operating Temperature –30 to +70°C (no freezing)
Storage Temperature –40 to +80°C (no freezing)
Relative Humidity 45 to 85% (no condensation)
Rated Insulation Voltage (Ui) 300V
Degree of Protection IP67 (IEC60529)
Actuator Operating Speed 0.05 to 1.0m/s
Direct Opening Travel 10mm minimum
Direct Opening Force 50N minimum
Thermal Current (Ith) 10A
Rated Current (Ie)*
Rated Voltage (Ue) 30V 125V 250V
AC Resistive load (AC-12) 10A 10A 6A
Inductive Load (AC-15) 10A 5A 3A
DC Resistive load (DC-12) 8A 2.2A 1.1A
Inductive Load (DC-13) 4A 1.1A 0.6A
Minimum Applicable Load
(reference)
5V AC/DC, 1mA (Applicable range may vary with operating
conditions and load types.)
Operating Frequency 900 operations per hour
Mechanical Life 1,000,000 operations minimum (GS-ET-15)
Electrical Life
100,000 operations minimum (AC-12 250V, 6A)
1,000,000 operations minimum (24V AC/DC,100mA)
(operation frequency: 900 operations per hour)
Weight (approx.) Plastic head: 80g, Metal head: 110g
*TÜV rating: AC-15 3A/250V, DC-13 4A/30V
Dimensions (mm)
Gland Port
1 20 1
36.2
91
R2.2
15
24
30
30
Miniature HS5D Full Size HS1B
7
HS1B features:
Rugged aluminum die-cast housing•
Direct Opening Action•
Available with or without an indicator (red or green)•
Flexible Installation: Two actuator entries and three conduit ports are provided•
Select from two circuit configurations (1NO-1NC or 2NC).•
IP67•
Part Numbers
Model Contact
Configuration
Pilot
Light Part Number
2
1
3
4
Main Circuit Auxiliary Circuit
-
+
1NC-1NO
Without HS1B-11R
Red LED HS1B-114R-R
Green
LED HS1B-114R-G
2
1
3
4
Main Circuit Auxiliary Circuit
-
+
2NC
Without HS1B-02R
Red LED HS1B-024R-R
Green
LED HS1B-024R-G
Standard stock items in bold.
Actuator Keys & Accessories
Appearance Part Number Description
HS9Z-A1 Straight Actuator
(Mainly for sliding doors)
HS9Z-A2 Right-angle Actuator
(Mainly for rotating doors)
HS9Z-A3 Adjustable Actuator
HS9Z-T1 Key Wrench (included with
switch)
HS9Z-P1 Conduit Opening Plug
Actuators are not included and must be ordered separately.
Specifications
Conforming to Standards IEC60947-5-1, EN60947-5-1, GS-ET-15, UL508,
CSA C22.2 No. 14
Operating Temperature –20 to +70˚C (no freezing)
Storage Temperature –40 to +80˚C
Relative Humidity 45 to 85% (no condensation)
Rated Insulation Voltage (Ui) 300V (between LED and ground: 60V)
Degree of Protection IP67 (IEC60529)
Actuator Operating Speed 0.05 to 1.0m/s
Direct Opening Travel 11mm minimum
Direct Opening Force 20N minimum
Thermal Current (Ith) 10A
Rated Operating Current (Ie)
Rated Voltage (Ue) 30V 125V 250V
AC Resistive load (AC-12)
Inductive load (AC-15)
10A
10A
10A
5A
6A
3A
DC Resistive load (DC-12)
Inductive load (DC-13)
8A
4A
2.2A
1.1A
1.1A
0.6A
Operating Frequency 900 operations/hour
Mechanical Life 1,000,000 operations
Electrical Life 100,000 operations (rated load)
Recommended Short Circuit
Protection
250V, 10A fuse (Type D01 based on IEC60269-1,
60269-2)
Indicator
Operating
Voltage 24V DC
Current 10mA
Light Source LED lamp
Lens Color Red or Green (12mm dia. Lens)
Weight (approx) 280g
Dimensions (mm)
G1/2
Conduit Port
64
15
49.5
42
125
52
ø5.4
210
36.5
40
35
4
±1.0
17.5
R2.7
www.IDEC.com/safety
800-262-IDEC
Full Size HS1B
8
HS6E features:
Compact body: 75 × 15 × 75mm •
15mm wide, thinnest solenoid interlock switch in the world
Reversible mounting and angled cable allow four actuator insertion directions•
Energy saving: 24V DC, 110mA (solenoid: 100mA, LED: 10mA)•
Manual unlocking possible on three sides•
LED indicator shows solenoid operation•
500N locking retention force•
Part Numbers
Mechanical Spring Lock (power solenoid to unlock)
Contact Configuration Cable
Length Part Number
(Actuator inserted) (Solenoid OFF)
1m
3m
5m
HS6E-L44B01-G
HS6E-L44B03-G
HS6E-L44B05-G
1m
3m
5m
HS6E-M44B01-G
HS6E-M44B03-G
HS6E-M44B05-G
1m
3m
5m
HS6E-N44B01-G
HS6E-N44B03-G
HS6E-N44B05-G
1m
3m
5m
HS6E-P44B01-G
HS6E-P44B03-G
HS6E-P44B05-G
1. Contact configuration shows the contact status when actuator is inserted and solenoid off for spring lock.
2. Contact configuration shows the contact status when actuator is inserted and solenoid on for solenoid lock.
3. Indicator LED color is green.
4. Actuator keys are not supplied with the interlock switch and must be ordered separately.
5. Standard stock items in bold.
Solenoid Lock (remove power to solenoid to unlock)
Contact Configuration Cable
Length Part Number
(Actuator inserted) (Solenoid ON)
1m
3m
5m
HS6E-L7Y4B01-G
HS6E-L7Y4B03-G
HS6E-L7Y4B05-G
1m
3m
5m
HS6E-M7Y4B01-G
HS6E-M7Y4B03-G
HS6E-M7Y4B05-G
1m
3m
5m
HS6E-N7Y4B01-G
HS6E-N7Y4B03-G
HS6E-N7Y4B05-G
1m
3m
5m
HS6E-P7Y4B01-G
HS6E-P7Y4B03-G
HS6E-P7Y4B05-G
A1A2
(+) (–)
A1A2
(+) (–)
Subminiature
www.IDEC.com/safety
800-262-IDEC
9
Subminiature HS6E
Actuator Keys & Accessories
Item Part Number Description
HS9Z-A61 Straight
HS9Z-A62
Right-angle
(actuator retention
force 100N max)
HS9Z-A62S
Right-angle with
Mounting Plate
HS9Z-A65
Angle adjustable with
hex screw (horizontal or
vertical configurable)
HS9Z-A66
Angle Adjustable
(horizontal or vertical
configurable)
HS9Z-T3 Manual Unlock Key
(long type - metal)
1. Actuators are not included and must be ordered separately.
2. Plastic Manual Unlock Key supplied with each unit
Specifications
Conforming to Standards
UL 508, CSA C22.2, No. 14, ISO 14119, IEC 60947-5-1, EN 60947-5-1
(TÜV approval), EN 1088 (TÜV approval), GS-ET-19, IEC 60204-1/EN
60204-1 (applicable standards for use)
Operating Temperature –25 to +50°C (no freezing)
Storage Temperature –40 to +80°C (no freezing)
Relative Humidity 45 to 85% (no condensation)
Rated Insulation Voltage (Ui)300V (door monitor contact), 150V (lock monitor contact),
30V (between LED or solenoid and ground)
Electric Shock Protection Class Class II (IEC 61140)
Degree of Protection IP67 (IEC 60529)
Actuator Operating Speed 0.05 to 1.0m/s
Direct Opening Travel 8.0mm minimum
Direct Opening Force 60N minimum
Thermal Current (Ith)
Operating temperature
(–25 to 35ºC)
2.5A (up to 2 circuits)
1.0A (3 or more circuits)
Operating temperature
(35 to 50ºC)
1.0A (1 circuit)
0.5A (2 or more circuits)
Rated
Operating
Current (Ie)
Rated Voltage (Ue) 30V 125V 250V
Main
& Lock
Monitor
Circuit
AC Resistive load (AC-12)
Inductive load (AC-15) 2A
1A
DC Resistive load (DC-12)
Inductive load (DC-13)
2A
1A
0.4A
0.22A
Door
Monitor
Circuit
AC Resistive load (AC-12)
Inductive load (AC-15) 2.5A
1.5A
1.5A
0.75A
DC Resistive load (DC-12)
Inductive load (DC-13)
2.5A
2.3A
1.1A
0.55A
0.55A
0.27A
Minimum Applicable Load
(reference) 3V AC/DC, 5 mA
Actuator Retention Force 500N maximum (GS-ET-19)
Operating Frequency 900 operations/hour
Mechanical Life 1,000,000 operations minimum (GS-ET-19)
Electrical Life
100,000 operations minimum (rated load)
1,000,000 operations minimum (24V AC/DC, 100mA)
(operating frequency 900 operations/hr)
Cable UL2464, No. 22 AWG (12-core: 0.3mm2 or equivalent/core)
Cable Diameter ø7.6mm
Weight 220g - 1m cable type, 410g - 3m cable type, 600g - 5m cable type
1. UL, c-UL rating: Main/Lock monitor circuit: 125V AC, 1A Pilot duty, 125V DC, 0.22A Pilot duty
Door monitor circuit:240V AC, 0.75A Pilot duty250V DC, 0.27A Pilot duty
2. TÜV rating: Main/Lock monitor circuit: AC-15 125V/1A, DC-13 125V/0.22A
Door monitor circuit: AC-15 240V/0.75A, DC-13 250V/0.27A
Dimensions (mm)
Manual Unlocking Key
1
120
(2.3)
C12
35
30
20.5
10.1
15
10.4
15
4
4
75
R2.1
28.5
37
41.8
ø4.4
(22.5) (22.5)
10
HS5E features:
World’s smallest 4 contact solenoid interlock switch (35 x 40 x 146mm)•
Flexible installation - the head can rotate, allowing 8 different actuator entries•
Metal actuator entry slot ensures long life•
Actuator locking strength is 1400N minimum (GS-ET-19)•
LED pilot light indicates the solenoid status•
IP67 (IEC60529)•
Part Numbers
Mechanical Spring Lock (power solenoid to unlock) Solenoid Lock (remove power to solenoid to unlock)
Contact Arrangement Pilot
Light
Cable
Length Part Number Contact Arrangement Pilot
Light
Cable
Length Part Number
24
11
23
12 4241
5453
Main Circuit:
Monitor Circuit:
Monitor Circuit:
No
1m
3m
5m
HS5E-A4001
HS5E-A4003
HS5E-A4005
Main Circuit:
24
11
23
12 4241
5453
Monitor Circuit:
Monitor Circuit:
No
1m
3m
5m
HS5E-A7Y001
HS5E-A7Y003
HS5E-A7Y005
Yes
1m
3m
5m
HS5E-A4401-G
HS5E-A4403-G
HS5E-A4405-G
Yes
1m
3m
5m
HS5E-A7Y401-G
HS5E-A7Y403-G
HS5E-A7Y405-G
51 52
41 4212
23
11
24
Main Circuit:
Monitor Circuit:
Monitor Circuit:
No
1m
3m
5m
HS5E-B4001
HS5E-B4003
HS5E-B4005
51 52
41 4212
23
11
24
Main Circuit:
Monitor Circuit:
Monitor Circuit:
No
1m
3m
5m
HS5E-B7Y001
HS5E-B7Y003
HS5E-B7Y005
Yes
1m
3m
5m
HS5E-B4401-G
HS5E-B4403-G
HS5E-B4405-G
Yes
1m
3m
5m
HS5E-B7Y401-G
HS5E-B7Y403-G
HS5E-B7Y405-G
Monitor Circuit:
Monitor Circuit:
Main Circuit: 411211
21 22
51 52
42
No
1m
3m
5m
HS5E-D4001
HS5E-D4003
HS5E-D4005
Monitor Circuit:
Monitor Circuit:
411211
21 22
51
Main Circuit:
52
42
No
1m
3m
5m
HS5E-D7Y001
HS5E-D7Y003
HS5E-D7Y005
Yes
1m
3m
5m
HS5E-D4401-G
HS5E-D4403-G
HS5E-D4405-G
Yes
1m
3m
5m
HS5E-D7Y401-G
HS5E-D7Y403-G
HS5E-D7Y405-G
24
11
23
12 4241
5453
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Yes
1m
3m
5m
HS5E-VA4401-G
HS5E-VA4403-G
HS5E-VA4405-G
24
11
23
12 4241
5453
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Yes
1m
3m
5m
HS5E-VA7Y401-G
HS5E-VA7Y403-G
HS5E-VA7Y405-G
411211
21 22
51 52
42
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Yes
1m
3m
5m
HS5E-VD4401-G
HS5E-VD4403-G
HS5E-VD4405-G
411211
21 22
51 52
42
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Yes
1m
3m
5m
HS5E-VD7Y401-G
HS5E-VD7Y403-G
HS5E-VD7Y405-G
51 52
41 4212
21
11
22
Main Circuit:
Main Circuit:
Yes
1m
3m
5m
HS5E-DD4401-G
HS5E-DD4403-G
HS5E-DD4405-G
24
11
23
12 4241
5453
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Yes
1m
3m
5m
HS5E-A44L01-G
HS5E-A44L03-G
HS5E-A44L05-G Rear Button
Unlock Type
Monitor Circuit:
Monitor Circuit:
Main Circuit: 411211
21 22
51 52
42
Yes
1m
3m
5m
HS5E-D44L01-G
HS5E-D44L03-G
HS5E-D44L05-G
1. Contact configuration shows the contact status when actuator is inserted and solenoid off for spring lock.
2. Contact configuration shows the contact status when actuator is inserted and solenoid on for solenoid lock.
3. Main circuit has door and lock monitor contacts wired in series internally.
4. Standard stock items in bold.
A1A2
(+) (–)
Door Monitor
(Actuator inserted) Lock Monitor
(Solenoid ON)
A1A2
(+) (–)
Door Monitor
(Actuator inserted) Lock Monitor
(Solenoid OFF)
Miniature
11
HS5E
Actuator Keys & Accessories
Item Part
Number Description
HS9Z-A51 Straight
HS9Z-A52 Right-angle
HS9Z-A53 Angle adjustable
vertical operation
HS9Z-A55
Angle adjustable
horizontal/vertical
operation Note 1
HS9Z-A5P
Plug Actuator (allows
switch to be used as
interlock plug unit)
HS9Z-PH5
Padlock Hasp (prevents
unauthorized insertion
of actuator)
HS9Z-
SP51
Mounting Plate (allows
easy mounting to
aluminum frames)
HS9Z-T3 Manual unlock key
(long type - metal)
HS9Z-SH5 Sliding Actuator
1. The actuator tensile strength is 500N minimum.
2. Actuators are not included and must be ordered separately.
Dimensions (mm)
33
5
30
13.4
32.9
20
40
36.2 106
145.7 (6.3)
20
35
1
1
R2.2
Specifications
Conforming to Standards
ISO14119, IEC60947-5-1, EN60947-5-1 (TÜV approval), EN1088, GS-ET-19
(BG approval), UL508, CSA C22.2, No. 14, GB 140485.5 (CCC approval)
IEC60204-1/EN60204-1
Operating Temperature –25 to 50°C (no freezing)
Relative Humidity 45 to 85% (no condensation)
Rated Insulation Voltage (Ui) Note 1 250V (between LED, solenoid and grounding: 30V)
Storage Temperature –40 to +80°C (no freezing)
Actuator Operating Speed 0.05 to 1.0m/s
Direct Opening Travel Actuator HS9Z-A51: 11mm minimum
Actuator HS9Z-A52/A53/A55: 12mm minimum
Direct Opening Force 80N minimum
Thermal Current (Ith) 2.5A
Rated Operating
Current (Ie) Note 2
Rated Voltage (Ue) 30V 125V 250V
AC Resistive load (AC-12) 2A 1A
Inductive Load (AC-15) 1A 0.5A
DC Resistive load (DC-12) 2A 0.4A 0.2A
Inductive Load (DC-13) 1A 0.22A 0.1A
Minimum Applicable Load
(reference) 3V AC/DC, 5mA
Actuator Retention Force 1400N minimum (GS-ET-19)
Operating Frequency 900 operations per hour
Mechanical Life 1,000,000 operations minimum (GS-ET-19)
Electrical Life 100,000 operations minimum (operating frequency 900 operations per
hour, rated load AC-12, 250V, 1A)
Cable UL2464, No. 21AWG - 8-core: 0.5mm2 or equivalent/core
(HS5E-V types: No. 22AWG - 12-core :0.3mm2 on equivalent/ core)
Cable Diameter ø7.6mm
Solenoid Rated Voltage 24V DC (100% duty cycle)
Current 266mA (initial value)
Pilot Light Rated Voltage 24V DC
Current 10mA
Weight (approx.) 400g - 1m cable type, 580g - 3m cable type, 760g - 5m cable type
1. UL rating: 125V
2. TUV, BG rating: AC-15, 0.5A/250V, DC-13, 0.22A/125V
UL, c-UL rating: Pilot duty AC 0.5A/125V, Pilot duty DC 0.22A/125V
www.IDEC.com/safety
800-262-IDEC
12
HS1E features:
Plastic Housing: Lightweight•
1500N locking retention force•
Available with a red or green indicator•
Choose from 4 circuit configurations•
Flexible Installation: The actuator can be accessed from two directions•
Ease of Wiring: M3.5 termination screws•
Part Numbers (Mechanical Spring Lock only)
Contact Configuration LED Standard Manual Unlock Key
Main circuit: 1NC + 1NC
Monitor circuit: 1NO/1NO
7
8
6
2
1
3
4
5
Contacts are linked to
the solenoid mechanically.
Indicator
Monitor Circuit
Main Circuit
Solenoid Power
None HS1E-40R HS1E-40KR
Green HS1E-44R-G HS1E-44KR-G
Red HS1E-44R-R HS1E-44KR-R
Main circuit: 1NC + 1NC
Monitor circuit: 1NO
7
8
6
2
1
3
4
5
Monitor Circuit
Main Circuit
Solenoid Power
Contacts are linked to
the solenoid mechanically.
Indicator
None HS1E-140R HS1E-140KR
Green HS1E-144R-G HS1E-144KR-G
Red HS1E-144R-R HS1E-144KR-R
Main circuit: 1NC + 1NC
Monitor circuit: 1NC + 1NC
6
2
1
3
4
5+
7
8
Monitor Circuit
Main Circuit
Solenoid Power
Contacts are linked to
the solenoid mechanically.
Indicator
None HS1E-240R HS1E-240KR
Green HS1E-244R-G HS1E-244KR-G
Red HS1E-244R-R HS1E-244KR-R
Main circuit: 1NC + 1NC
Monitor circuit: 1NC
6
2
1
3
4
5+
7
8
Monitor Circuit
Main Circuit
Solenoid Power
Contacts are linked to
the solenoid mechanically.
Indicator
None HS1E-340R HS1E-340KR
Green HS1E-344R-G HS1E-344KR-G
Red HS1E-344R-R HS1E-344KR-R
1. Key wrench for TORX screws (HS9Z-T1) is supplied with the interlock switch.
2. Actuator is not supplied with the interlock switch, and must be ordered separately.
3. TORX is a registered trademark of Camcar Textron.
Full Size
13
HS1E
Actuator Keys & Accessories
Item Part
Number Description
HS9Z-A1 Straight Actuator
HS9Z-A2 Right-angle Actuator
HS9Z-A3 Angle Adjustable Actuator
HS9Z-T1 Key Wrench (included with
switch)
HS9Z-P1 Conduit Opening Plug
(G1/2)
Actuators are not included and must be ordered separately.
Dimensions (mm)
Note:
Plug the unused actuator entry slot using the slot plug
supplied with the interlock switch.
4
40 39.2
12.3
63
45
47.5
10
45.4
33
88
49.5
129
121
10
2
104
5.5 4
23.5 26
35
5
Specifications
Conforming to Standards
EN1088, IEC60947-5-1, EN60947-5-1(TUV), ISO14119, GS-ET-19
(BG), UL508, CSA C22.2 No. 14, GB14048.5 (CCC approval),
IEC60204-1, EN60204-1 (applicable standards for use)
Operating Temperature –20 to +40˚C (no freezing)
Storage Temperature –40 to +80˚C
Relative Humidity 45 to 85% (no condensation)
Electric Shock Protection Class II (according to IEC61140)
Degree of Protection IP67 (IEC60529)
Vibration
Resistance
Operating Extremes 10 to 55Hz (amplitude 0.35mm)
Damage Limits 10Hz (amplitude 1.5m)
Shock Resistance 1,000m/sec2 (approx. 100G)
Actuator Retention Force 1,500N minimum (per GS-ET-19)
Actuator Operating Speed 0.05 to 1.0m/s
Direct Opening Travel 11mm minimum
Direct Opening Force 20N minimum
Thermal Current (Ith) Main circuit: 10A, Auxiliary circuit: 3A
Rated Operating Current (Ie)
Rated Voltage (Ue) 30V 125V 250V
Main
Circuit
AC Resistive load (AC-12)
Inductive load (AC-15)
10A
10A
10A
5A
6A
3A
DC Resistive load (DC-12)
Inductive load (DC-13)
6A
3A
0.9A
Auxiliary
Circuit
AC Resistive load (AC-12)
Inductive load (AC-15)
3A
3A
3A
DC Resistive load (DC-12)
Inductive load (DC-13)
3A
0.9A
Operating Frequency 900 operations/hour max.
Mechanical Life 1,000,000 operations min. (at full rated load)
900 ops/hr (AC-12/250V, 6A)
Electrical Life 100,000 operations (rated load)
Solenoid
Unit
Operating Voltage 24V DC (100% duty cycle)
Current 292mA (initial value)
Coil Resistance 102Ω (at 20ºC)
Pickup Voltage 20.4V maximum (at 20ºC)
Drop Out Voltage 2.4V minimum (at 20ºC)
Allowable Voltage 26.4V max (continuous)
Insulation Class Class F
Indicator
Operating Voltage 24V DC
Current 10mA
Light Source LED lamp
Lens Color Red or Green
Weight (approx) 500g
www.IDEC.com/safety
800-262-IDEC
14
HS1L features:
3,000N locking retention force•
LED indicator•
Energy-efficient solenoid •
6 contacts with easy-to-wire terminations•
M3 terminal screws for easy wiring•
Part Numbers
Mechanical Spring Lock (power solenoid to unlock)
Contact Configuration Conduit
Size LED Part Number
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
2221
41 421211
33 34
51 52
61 62
Main circuit:
G1/2 Red HS1L-R44KMSR-R
Green HS1L-R44KMSR-G
PG13.5 Red HS1L-R44KMSRP-R
Green HS1L-R44KMSRP-G
M20 Red HS1L-R44KMSRM-R
Green HS1L-R44KMSRM-G
Main circuit:
Main circuit:
Monitor circuit:
Monitor circuit:
2221
41 421211
33 34
51 52
63 64
G1/2 Red HS1L-DQ44KMSR-R
Green HS1L-DQ44KMSR-G
PG13.5 Red HS1L-DQ44KMSRP-R
Green HS1L-DQ44KMSRP-G
M20 Red HS1L-DQ44KMSRM-R
Green HS1L-DQ44KMSRM-G
2221
41 421211
51 52
3231
61 62
Main circuit:
Main circuit:
Monitor circuit:
Monitor circuit:
G1/2 Red HS1L-DT44KMSR-R
Green HS1L-DT44KMSR-G
PG13.5 Red HS1L-DT44KMSRP-R
Green HS1L-DT44KMSRP-G
M20 Red HS1L-DT44KMSRM-R
Green HS1L-DT44KMSRM-G
Solenoid Lock (remove power to solenoid to unlock)
Contact Configuration Conduit
Size LED Part Number
()
X2
()
X1
()
A2
()
A1
LED
Door Monitor
(Actuator Inserted)
Lock Monitor
(Solenoid ON)
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
2221
41 421211
33 34
51 52
61 62
Main circuit:
G1/2 Red HS1L-R7Y4KMSR-R
Green HS1L-R7Y4KMSR-G
PG13.5 Red HS1L-R7Y4KMSRP-R
Green HS1L-R7Y4KMSRP-G
M20 Red HS1L-R7Y4KMSRM-R
Green HS1L-R7Y4KMSRM-G
Main circuit:
Main circuit:
Monitor circuit:
Monitor circuit:
2221
41 421211
33 34
51 52
63 64
G1/2 Red HS1L-DQ7Y4KMSR-R
Green HS1L-DQ7Y4KMSR-G
PG13.5 Red HS1L-DQ7Y4KMSRP-R
Green HS1L-DQ7Y4KMSRP-G
M20 Red HS1L-DQ7Y4KMSRM-R
Green HS1L-DQ7Y4KMSRM-G
2221
41 421211
51 52
3231
61 62
Main circuit:
Main circuit:
Monitor circuit:
Monitor circuit:
G1/2 Red HS1L-DT7Y4KMSR-R
Green HS1L-DT7Y4KMSR-G
PG13.5 Red HS1L-DT7Y4KMSRP-R
Green HS1L-DT7Y4KMSRP-G
M20 Red HS1L-DT7Y4KMSRM-R
Green HS1L-DT7Y4KMSRM-G
1. Contact configuration shows the contact status when actuator is inserted and solenoid off for spring lock.
2. Contact configuration shows the contact status when actuator is inserted and solenoid on for solenoid lock.
3. Actuators are not supplied with the interlock switch and must be ordered separately.
4. Standard stock items in bold.
()
X2
()
X1
()
A2
()
A1
LED
Door Monitor
(Actuator Inserted)
Lock Monitor
(Solenoid OFF)
www.IDEC.com/safety
800-262-IDEC
Full Size
15
Actuator Keys & Accessories
Item Part Number Description
HS9Z-A1S Straight Actuator
HS9Z-A2S L-shaped Actuator
HS9Z-A3S Angle Adjustable Actuator (vertical
operation only)
HS9Z-T1 Key Wrench (included with switch)
HS9Z-P1 Conduit Opening Plug (G1/2)
Actuators are not included and must be ordered separately.
Dimensions (mm)
44.7
3.7
40
35 1.5
89
61
21
4
104
4
12.3
10
36
45.4
7.5
88
49.5
129
121
10
2
5.5 4
23.5 26
51
5
33
5
45
63
Specifications
Conforming to Standards
ISO14119, IEC60947-5-1. EN60947-5-1 (TÜV approval),
GS-ET-19 (TÜV approval). UL508, CSA C22.2 No. 14
IEC60204-1/EN60204-1 (applicable standards for use)
Operating Temperature −20 to +55°C (no freezing)
Storage Temperature –40 to +80°C (no freezing)
Relative Humidity 45 to 85% (no condensation)
Rated Insulation Voltage (Ui) 300V
Overvoltage Category III
Electric Shock Protection Class II (IEC 61140)
Degree of Protection IP67 (IEC 60529)
Shock Resistance Damage limits: 1000m/s2
Actuator Retention Force 3000N minimum (GS-ET-19)
Actuator Operating Speed 0.05 to 1.0m/s
Direct Opening Travel 11mm minimum
Direct Opening Force 50N minimum
Thermal Current (Ith) 10A
Rated Operating
Current (Ie)
Rated Rated Voltage (Ue) 30V 125V 250V
AC Resistive Load (AC-12) 10A 10A 6A
Inductive Load (AC-15) 10A 5A 3A
DC Resistive Load (DC-12) 8A 2.2A 1.1A
Inductive Load (DC-13) 4A 1.1A 0.6A
Operating Frequency 900 operations per hour
Mechanical Life 1,000,000 operations minimum (GS-ET-19)
Electrical Life
100,000 operations minimum (AC-15 3A/250V)
1,000,000 operations minimum (24V AC/DC, 100mA)
(operating frequency 900 operations per hour)
Solenoid
Unit
Rated Operating
Voltage 24V DC (100% duty cycle)
Rated Current 200mA (initial value)
Indicator
Rated Operating
Voltage 24V DC
Rated Current 10mA
Light Source LED
Illumination Color Green (G), Red (R)
Weight (approx.) 450g (HS1L-DQ44)
1. Minimum applicable load (reference value): 3V AC/DC, 5mA
(Applicable range may vary with operating conditions and load types.)
2. TÜV rating: AC-15 3A/250V, DC-13 4A/30V
UL, c-UL rating: A300, Pilot duty: AC 3A/250V, Pilot duty: DC 4A/30V
HS1L
16
HS1C features:
Rugged aluminum die-cast housing•
1500N locking retention force•
Flexible Installation: The actuator can be accessed from two directions•
Select from four different circuit configurations•
IP67•
Part Numbers (Mechanical Spring Lock Only)
Contact Configuration Indicator LED Part Number
Main Circuit: 1NC+1NC
Auxiliary Circuit: 1NO/1NO
Auxiliary
Circuit
Main
Circuit
Solenoid
Power
Indicator
Contacts are linked
to the solenoid
mechanically
+
+
6
2
1
3
4
5
8
7
Green HS1C-R44R-G
Red HS1C-R44R-R
Main Circuit: 1NC+1NC
Auxiliary Circuit: 1NO
7
8
6
2
1
3
4
5
+
+
Auxiliary
Circuit
Main
Circuit
Solenoid
Power
Indicator
Contacts are linked
to the solenoid
mechanically
Green HS1C-R144R-G
Red HS1C-R144R-R
Contact Configuration Indicator LED Part Number
Main Circuit: 1NC+1NC
Auxiliary Circuit: 1NC+1NC
Auxiliary
Circuit
Main
Circuit
Solenoid
Power
7
8
6
2
1
3
4
5
+
+
Indicator
Contacts are linked
to the solenoid
mechanically
Green HS1C-R244R-G
Red HS1C-R244R-R
Main Circuit: 1NC+1NC
Auxiliary Circuit: 1NC
7
8
6
2
1
3
4
5
+
+
Auxiliary
Circuit
Main
Circuit
Solenoid
Power
Indicator
Contacts are linked
to the solenoid
mechanically
Green HS1C-R344R-G
Red HS1C-R344R-R
www.IDEC.com/safety
800-262-IDEC
Full Size
17
Actuator Keys & Accessories
Item Part Number Description
HS9Z-A1 Straight Actuator
HS9Z-A2 Right-angle Actuator
HS9Z-A3 Adjustable Actuator
HS9Z-T1 Key Wrench (included
with switch)
HS9Z-P1 Conduit Opening Plug
(G1/2)
Actuators are not included and must be ordered separately.
Dimensions (mm)
23.5
1.5
10
106
125
2
47
R2.7
ø5.4
42
36.5
49.5 26
ø5.2
74
39.7
35
4
Conduit
Port G1/2
Specifications
Conforming to Standards EN1088, IEC60947-5-1, EN60947-5-1, GS-ET-19, UL508,
GB 140485.5 (CCC approval), CSA C22.2 No. 14
Operating Temperature –20 to +40˚C (no freezing)
Storage Temperature –40 to +80˚C
Relative Humidity 40 to 85% (no condensation)
Rated Insulation Voltage (Ui) 300V (between LED or solenoid and ground: 60V)
Actuator Retention Force 1,500N minimum
Actuator Operating Speed 0.05 to 1.0m/s
Direct Opening Travel 11mm minimum
Direct Opening Force 20N minimum
Thermal Current (Ith) Main circuit: 10A, Auxiliary circuit: 3A
Rated Operating Current (Ie)
Rated Voltage (Ue) 30V 125V 250V
Main
Circuit
AC Resistive load (AC-12)
Inductive load (AC-15)
10A
10A
10A
5A
6A
3A
DC Resistive load (DC-12)
Inductive load (DC-13)
6A
3A
0.9A
Auxiliary
Circuit
AC Resistive load (AC-12)
Inductive load (AC-15)
3A
3A
3A
DC Resistive load (DC-12)
Inductive load (DC-13)
3A
0.9A
Operating Frequency 900 operations/hour max.
Mechanical Life 1,000,000 operations
Electrical Life 100,000 operations (rated load)
Recommended Short Circuit Protection 250V, 10A fuse (Type D01 based on IEC60269-1, 60269-2)
Solenoid Unit Operating Voltage 24V DC (100% duty cycle)
Current 415mA (initial value)
Indicator
Operating Voltage 24V DC
Current 10mA
Light Source LED lamp
Lens Color Red or Green
Weight (approx) 660g
HS1C
18
Additional Safety Products www.IDEC.com/safety
FS1A Safety Controllers - Consolidate Multiple Safety Relays to One SmartSafety Relay
FS1A features:
No programming required•
Easily replaces 2 - 3 safety relay control modules•
8 or 24 pre-programmed logic safety circuits•
Connect with various types of safety inputs •
Monitor status of safety I/Os and error codes•
IEC 61508 integrity level 3, ISO 13849-1 performance level e •
and EN954-1 safety category 4 compliant
When you want a straightforward system that’s safe, easy-to-install and won’t
cost an arm and a leg, an IDEC SafetyOne FS1A is the answer! The FS1A
offers up to 24 pre-programmed logic safety circuits. That means you can
configure a system without any programming, just by selecting one logic from
either 8 (FS1A-C01S) or 24 (FS1A-C11S) to configure a safety system.
Unlike multiple safety relays, which require lots of cumbersome wiring and take
up too much space, the entry-level safety controller makes it easy to consolidate
basic safety circuits. At the same time they save space and minimize wiring.
FS1A SafetyOne can easily replace two to three safety relay control modules
with no programming required. Not only that, SafetyOne can be configured
simply by flipping dip switches to select a logic. One module can connect with
various safety components such as Emergency Stop switches, light curtains,
Interlock switches, two hand controls and auxiliary components such as muting
lights, sensors and much more.
FS1A is UL listed, TUV rated and CE marked, as well as meets IEC 61508 integrity
level 3, ISO 13849-1 performance level e and EN954-1 safety category 4.
72
mm
114.5
mm
113.5
mm
Monitor Output
Replaces more than seven safety
relay modules
Four safety output lines
Muting function of light curtains
Mode selection
Solenoid drive output
Light curtains
Muting lamp
Muting sensors
Hazardous
area
Object
Safety Input
Solenoid drive
output
Monitor signals
Error signals
Safety Outputs
Enabling
Switch
Light
Curtain
Emergency
Stop
Switch
Interlock
Switch
Selector
Switch
Safety
Output 1
Safety
Output 2
Two-hand
Control
Emergency
Stop Switch
Light Curtain
(PNP)
Interlock
Switch Safety
Output 1
Safety
Output 2
FS1A-C11S
Logic 103
FS1A-C11S
Logic 12A
FS1A-C11S
Logic 104
PLC
Two-hand Control
Emergency
Stop Switch
Enabling
Switch
Selector
Switch
Interlock
Switch
Safety
Output 2
Safety
Output 1-1
Safety
Output 1-2
Safety
Output 3
19
www.IDEC.com/safety
SG Safety Light Curtains - a Quality, Affordable Hazardous Area Access Solution
SG Light Curtain features:
Integrated light curtain for Finger or Body Protection•
Operating distance up to 6m or 19m•
Heights from 150 to 1800mm•
Compact 32 x 37mm profile•
Sturdy profile and rotating brackets •
User interface with display•
Alignment function•
Hand Protection Presence Protection
The SG2 Type 2 series offers two models, the SG2 basic and the SG2 extended.
Available functions include Test/Restart, EDM and Anti-interference. With very
fast response times, the SG2 series can be installed right next to a hazardous area
improving productivity. The rotating mounting brackets make installation and the
alignment of the emitting and receiving units easy, even at long distances and in
applications that use mirrors.
Finger Protection Hand Protection
With mounting brackets that rotate, no connection necessary between emitter
and receiver, and configuration that can be accomplished without external control
units or supplementary cables, the SG4 Type 4 light curtains are one of the best
available on the market today. In addition, the light curtains can be aligned using
the 7 segment display on either the emitter or receiver.
Enabling Switches - Ensuring Operator Safety
HE2B
HE3B
HE5B
HE1G
HE1B
HE6B
HE5B &
HE9Z-GSH51
Enabling Switch features:
Ergonomically-designed OFF-ON-OFF 3-position •
operation
Employs direct opening action mechanism for ON-OFF •
operation by pressing tightly
Contacts will not turn on when released from OFF •
(position 3) to OFF (position 1)
IEC/EN 60947-5-8 Compliant•
3 Position Operation
Terminal
Contact
Movable
Contact
Position 1
General Pushbutton Switch
(2-position) 3-position Enabling Switch
OFF
OFF
ON
OFF
ON
No position
1. Press 1. Press
lightly
3. Press
fully
4. Release
2. Release 2. Release
Button
released
Position 2
Button
pressed
Position 3
Button
pressed
fully
IDEC enabling switches are used in numerous pendants and grip switches around
the world. Developed using IDEC’s fundamental philosophy to provide high
reliability in products, our enabling switches provide optimal safety.
An enabling switch is a 3-position (OFF-ON-OFF) switch to allow machine
operation only when the switch is lightly pressed and held in the middle
position (position 2). Because it disables machine operation when released
(position 1) or further depressed (position 3) by a panicked operator, the
safety of operators is ensured. When operators use pendants to perform
teaching, system changeover and maintenance, they must have protection against
unpredictable machine operation. Therefore teaching pendants are equipped with
3-position enabling switches.
USA
IDEC Corporation
Tel: (408) 747-0550
opencontact@IDEC.com
Canada
IDEC Canada Ltd.
Tel: (905) 890-8561
sales@ca.IDEC.com
Australia
IDEC Australia Pty. Ltd.
Tel: +61-3-9763-3244
sales@au.IDEC.com
Japan
IDEC Corporation
Tel: +81-6-6398-2571
products@IDEC.co.jp
United Kingdom
IDEC Electronics Ltd.
Tel: +44-1256-321000
IDEC@uk.IDEC.com
Germany
IDEC Elektrotechnik GmbH
Tel: +49-40-253054-0
service@IDEC.de
Hong Kong
IDEC (H.K.) Co., Ltd.
Tel: +852-2803-8989
info@hk.IDEC.com
China/Beijing
IDEC (Beijing) Corporation
Tel: +86-10-6581-6131
idec@cn.IDEC.com
China/Shanghai
IDEC (Shanghai) Corporation
Tel: +86-21-5353-1000
idec@cn.IDEC.com
China/Shenzhen
IDEC (Shenzhen) Corporation
Tel: +86-755-8356-2977
Singapore
IDEC Asia Pte. Ltd.
Tel: +65-6746-1155
info@sg.IDEC.com
Taiwan
IDEC Taiwan Corporation
Tel: +886-2-2698-3929
service@tw.IDEC.com
©2010 IDEC Corporation. All Rights Reserved.
Catalog No. HS9Y-B100-0 12/10 10K
www.IDEC.com
Specifications and other descriptions in this catalog are subject to change without notice.
www.IDEC.com/safety
800-262-IDEC
Product Information
Safety Products
www.IDEC.com/safety
Product Support
Technical support:
support@IDEC.com
Find your local IDEC
Representative or Distributor:
www.IDEC.com/usa/locator
Phone:
800-262-IDEC
E-Stops
www.IDEC.com/usa/estop
For over 60 years, IDEC has manufactured reliable, high-quality Emergency
Stop switches and consistently led the market in new technology and
innovation for machine operator safety. By surpassing current international
standards, IDEC E-Stops are the safest in the world.
RF1V Force Guided Relays
www.IDEC.com/relays
Force guided relays are used in safety circuits to detect failures such as
contact welding and damage to the contact spring. The contacts of these
relays are “forced” to open and close by a guide connected to the armature.
Available in four or six pole models, all relays have 6A rated contacts. RF1V
can be mounted directly on a printed circuit board or can use DIN RAIL or PCB
mount sockets.
www.IDEC.com/usa