Rev.12.04.07
cxa10
2 of 4
Embedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
Specifications
OUTPUT SPECIFICATIONS
Voltage accuracy ±1.0%
Line regulation Singles/dual positives ±0.1%
(LL to HL) Dual negatives ±0.2%
Load regulation Full load to ±0.15%
(not incl. cross reg.) minimum load
Min. load All outputs 10%
Ripple and noise 3.3 V and 5.0 V 30 mV pk-pk
20 MHz bandwidth All others 60 mV pk-pk
All models 12 mV rms
Temperature coefficient ±0.01%/°C
Overvoltage protection Clamp type (See table and Notes 3, 4)
Short circuit protection Hiccup Continuous
Short <20 mΩ auto. recovery
Transient response Min. load to FL ±1.0%
Load cross regulation Min. load to FL (See Note 1) ±5.0%
INPUT SPECIFICATIONS
Input voltage range 48 Vin nominal 18-75 Vdc
Input fuse (See Note 10) 1.5 A HRC
Max. input rise 48 V ETS300 132-2 5 V/ms
and fall time
UVLO turn ON voltage (See Note 5) 94%
UVLO turn OFF voltage (See Note 5) 86%
Remote ON/OFF (See Note 7)
Logic compatibility CMOS/TTL/Open Collector
ON Open circuit
OFF <1 Vdc
EMC CHARACTERISTICS
ETS 300 386-1 table 5
Conducted emissions EN55022 (See Note 6) Level A
EN55022, external filter, Level B
VDE0878, 48 V models
Radiated emissions See Application Note 100
ESD air EN61000-4-2, level 3
ESD contact EN61000-4-2, level 4
Surge (500 V) EN61000-4-5, level 3, 4
Fast transients EN61000-4-4, level 3, 4
Radiated immunity EN61000-4-3, level 3
Conducted immunity EN61000-4-6, level 3
GENERAL SPECIFICATIONS
Efficiency See table
Isolation voltage Input/output test voltage 1500 Vdc
Switching frequency Fixed 400 kHz
Approvals and standards
EN60950, UL1950
(See Notes 7,8,9,10,11) CSA C22.2 No. 950
Material flammability UL94V-0
Weight 12 g (0.42 oz)
MTBF MIL-HDBK-217F 456,621 hours
(Representative model Parts stress method
48S05J @ 48 Vin) Ground Benign @ 25 °C
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating ambient -40 °C to +70 °C,
temperature See curves
Non-operating -55 °C to +105 °C
ETS 300 019-2-3 Classes T3.1 to T3.5
Air temperature Low: IEC 68-2-1 -40 °C
High: IEC 68-2-2 +70 °C
Change: IEC 68-2-14 -40°C to +70 °C
Relative humidity IEC 68-2-56 10% to 100% RH
IEC 68-2-30 Condensation
Vibration, Class 3M5 IEC68-2-6 2-9 Hz, 3 mm disp.
9-200 Hz 1 g MIL-STD-202F Method 204 cond. A
Shock, Class 3M5 IEC-68-2-29 Method 213B cond. A
MIL-STD-202F