JX INVERTER Compact and complete Quality & reliability you can depend on Co m m u n i c a t i o n s b u i l t- i n Cost and eco-friendly The smallest gets integrated... Key features include: Omron fully understands your needs, which * Ratings up to 7.5 kW is why we put quality and reliability first. * RS485 Modbus built-in And we keep listening, so our products come * Side-by-side mounting * EMC filter built-in * PID function * Micro-surge voltage suppression * Automatic energy saving With the RFI filter built-in, and the * Emergency shut-off communications integrated as standard, the * Second motor setting * Auto carrier-frequency reduction * PTC thermistor input * Cooling fan switch control * RoHS with new features and functionality that save you time and money. JX provides a compact and complete solution to a whole range of simple applications, such as conveyor control. 2 Level (dBV) 1 OMRON Function Block for Pulse Output Positioning. OMRON Function Block for Communications. 120 110 100 90 80 70 60 50 40 30 20 10 0 No Filter Integrated EMC filter 150 200 500k 1M 2M Conducted emission data 5M 10M 20M 30M Frequency (Hz) Easy network integration Easy communications setting Space and cost saving The RS485 Modbus is built into the RJ45 port in the inverter front, making it very easy to add inverters into the network without any extra option boards. Therefore, saving money and space. Modbus commands are implemented even in low end CP1 PLC family by Modbus-RTU Easy Master functionality, making it easier than ever to integrate the inverters into the network. The new JX has a built-in EMC filter that saves on costs and space compared with the standard external filter solution. 1 ph : EN61800-3 cat. C1 3 ph : EN61800-3 cat. C2 Everything on-board for your application 6 5 3 3 4 Sensor 5 ~ Emergency stop switch Power supply circuit IGBT gate Motor Sensor? 24 V Latch Set EMR Reset RS Interruption PCS 0V M Heating section No additional devices required Convenient and efficient Reliable emergency shutdown Even advanced functionality such as PID control is standard with the JX inverter making it a convenient solution for applications such as pumps & fans where pressure, flow and other processes need controlling. The parameter settings of two different motors can be stored, allowing the inverter to drive different motors with a unique inverter. The two motors are never working at the same time. The IGBT's output is directly switched off from the external input, assuring no energy is supplied to the motor. This hardware-based solution is more reliable than other CPU dependent solutions. 6 Power (%) 1,250 V Spikes in the terminal voltage are suppressed even when the wiring distance from the inverter to the motor is long 90 80 70 60 50 40 30 20 10 0 91% Damper system 76% 61% Energy-saving effect 22% Inverter system 10 20 30 40 50 60 70 80 90 100 Airflow (%) Silent operation Maximise motor life Automatic energy saving Depending on the inverter temperature, switching off the fan creates a noise-free atmosphere and prolongs the life time of the product. Advanced PWM control is used to suppress micro-surge voltages that sometimes cause malfunction in 400 V motors. The motor is thus protected and its life is prolonged. The Inverter always adopts the optimum energy-saving setting for cost savings in such applications as fans and pumps. The inverter can reduce energy consumption by 61% compared with standard mechanical systems. 4 Reliability with environmental responsibility AR RANT 3 Y W Omron is renowned for the reliability of its products. Moreover, Omron's policy is to offer environmentally safe products free from any banned substances. YEARS JX Compact & Complete * * * * * * * * * * * * * * * V/f controlled inverter Side by side mounting Built-in EMC filter Built-in RS-485 Modbus Overload detection function (150% during 60s) PID Micro-surge voltage suppression Automatic energy saving Emergency shut-off Second motor setting Auto carrier-frequency reduction PTC thermistor input Cooling fan switch control PC configuration tool: CX-Drive CE, UL, cUL, RoHS Ratings * 200 V Class single-phase 0.2 to 2.2 kW * 200 V Class three-phase 0.2 to 7.5 kW * 400 V Class three-phase 0.4 to 7.5 kW System configuration Power supply RJ45 - USB cable CX-Drive CX-One MCCB Remote operator extension cable AC reactor Filter LCD 5 lines remote operator * JX DC reactor Choke Motor Output reactor Ground * Only needed for 3 phase 200 V or to comply C1 on 3 phase 400 V models 6 Frequency inverters Specifications Type designation 3G3JX-AB002-EF JX series F: Built-in EMC Filter A: E: Europe standard Standard specs Max. applicable motor output 002: 0,2 kW ~ Voltage: B: Single-phase 200 VAC 2: Three-phase 200 VAC 4: Three-phase 400 VAC 075: 7,5 kW 200 V class Single-phase: 3G3JX@ AB002 AB004 AB007 AB015 AB022 - - - Three-phase: 3G3JX@ A2002 A2004 A2007 A2015 A2022 A2037 A2055 A2075 Output characteristics Motor kW*1 Applicable motor capacity Inverter capacity kVA 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 200 V 0.4 0.9 1.3 2.4 3.4 5.5 8.3 11.0 240 V 0.5 1.4 1.0 2.6 1.6 2.9 4.1 6.6 4.0 7.1 10.0 15.9 Proportional to input voltage: 0...240 V 9.9 24.0 13.3 32.0 30.0 - 40.0 - Rated output current (A) Max. output voltage Max. output frequency 400 Hz Power supply Rated input voltage and frequency Rated input current (A) Three-phase 200 V Rated input current (A) Single-phase 200 V Allowable voltage fluctuation Allowable frequency fluctuation 1.8 3.1 3.4 5.8 -15%...+10% +5% EMC filter (C1 single phase) Built-in filter Braking torque At short-time deceleration At capacitor feedback 50% for 3-phase 20 to 40% for 1-phase Approx. 50% Approx 20% to 40% Self cooling Cooling method *1 Single-phase 200...240 V 50/60 Hz 3-phase 200...240 V 50/60 Hz 5.2 9.3 13.0 20.0 9.0 16.0 22.5 - Approx 20% Forced-air-cooling Based on a standard 3-Phase standard motor. 400 V class Three-phase: 3G3JX@ Power supply Output characteristics Motor kW*1 A4004 A4007 A4015 A4022 A4040 A4055 A4075 0.4 0.75 1.5 2.2 4.0 5.5 7.5 380 V 0.9 1.6 2.5 3.6 5.6 480 V 1.2 1.5 2.0 2.5 Applicable motor capacity Inverter capacity kVA Rated output current (A) Max. output voltage Max. output frequency 13.3 16.0 3.3 5.0 7.0 11.0 16.5 20.0 -15%...+10% +5% EMC filter C2 class At short-time deceleration At capacitor feedback Cooling method JX 10.5 3-phase 380...480 V 50/60 Hz 2.0 Built-in filter *1 8.5 10.8 13.0 400 Hz Rated input voltage and frequency Rated input current (A) Allowable voltage fluctuation Allowable frequency fluctuation Braking torque 3.1 4.5 7.1 3.8 5.5 8.6 Proportional to input voltage: 0...480 V Approx. 50% Self cooling Approx. 20% to 40% Approx. 20% Forced-air-cooling Based on a standard 3-Phase standard motor. 7 Specifications Common specifications Control functions Model number 3G3JX@ Control methods Phase-to-phase sinusoidal modulation PWM (V/f) Output frequency range 0.5..400 Hz Digital set value: 0.01% of the max. frequency Analogue set value: 0.4% of the max. frequency (25 10 C) Digital set value: 0.1 Hz Resolution of frequency set value Analogue set value: 1/1000 of maximum frequency Resolution of output frequency 0.1 Hz 150% rated output current for one minute Overload capability Frequency precision Frequency set value V/f Characteristics Functionality Protection functions Constant/ reduced torque Analogue inputs Accel/Decel times 0.01 to 3000 s (line/curve selection), 2nd accel/decel setting available Output signals Standard functions Motor overload protection Status indicator LED's Run, Program, Power, Alarm, Power, Hz, Amps, Volume Led indicator Digital operator: Available to monitor frequency reference, output current, output frequency Electronic Thermal overload relay and PTC thermistor input Instantaneous overcurrent 180% of rated current Overload 150% for 1 minute Overvoltage 790 V for 400 V type and 395 for 200 V type Momentary power loss Following items are selectable: Alarm, 0 Hz start, frequency output at interruption, maximum frequency Cooling fin overheat Temperature monitor and error detection Stall prevention level Selectable level applicable only at constant speed or during acceleration and constant speed Ground fault Detected at power-on Power charge indication On when power is supplied to the control part Degree of protection IP20 Ambient humidity 90% RH or less (without condensation) Storage temperature -20C..+65 C (short-term temperature during transportation) Ambient temperature 10C to 50C (Both the carrier frequency and output current need to be reduced at over 40C.) Installation Indoor (no corrosive gas, dust, etc.) Installation height Max. 1000 m Vibration 5.9 m/s2 (0.6 G), 10 to 55 Hz (Complies with the test method specified in JIS C0040 (1999).) Display Ambient conditions 0 to 10 VDC (10 k), 4 to 20 mA (250 ), frequency setting volume (selectable), RS485 Modbus FW (forward), RV (reverse), CF1 to CF4 (multi-step speed), JG (jogging), DB (external DC injection braking), SET (2nd function), 2CH (2-step acceleration/deceleration), FRS (free run), EXT (external trip), USP (USP function), SFT (soft lock), AT (analog current input function selection), RS (reset), PTC (thermistor input), STA (3-wire startup), STP (3-wire stop), F/R (3wire forward/reverse), PID (PID selection), PIDC (PID integral reset), UP (UP of UP/DWN function), DWN (DWN of UP/DWN function), UDC (data clear of UP/DWN function), OPE (forced OPE mode), ADD (frequency addition), F-TM (forced terminal block), RDY (operation ready), SP-SET (special setting), EMR (emergency shutoff) RUN (signal during operation), FA1 (frequency arrival signal 1), FA2 (frequency arrival signal 2), OL (overload warning signal), OD (PID excess deviation signal), AL (alarm signal), DC (analog input disconnection detection signal), FBV (PID FB status output), NDc (network error), LOG (logical operation result), ODc (communication option disconnected), LOC (light load signal) AVR function, V/f characteristic selection, upper/lower limit, 16-step speeds, starting frequency adjustment, jogging operation, carrier frequency adjustment, PID control, frequency jump, analog gain/bias adjustment, S-shape acceleration/ deceleration, electronic thermal characteristics/level adjustment, retry function, simplified torque boost, trip monitor, soft lock function, frequency conversion display, USP function, 2nd control function, motor rotation speed UP/DOWN, overcurrent suppression function 2 analogue inputs 0 to 10 V (20 k), 4 to 20 mA (250 ) Inputs signals 8 Specifications Frequency inverters Dimensions IP 20 type 0.2 to 7.5 kW Figure 1 Figure 2 W W1 5 6 W W1 5 6 H1 H H1 H t1 5 Voltage class Single-phase 200 V Three-phase 200 V Three-phase 400 V 5 D1 1.9 t1 D1 D 1.9 Max. applicable motor output kW Inverter model 3G3JX@ 0.2 AB002 0.4 AB004 Figure Dimensions in mm W1 1 1 0.75 AB007 2 1.5 AB015 2 2.2 AB022 2 0.2 A2002 1 0.4 A2004 1 0.75 A2007 1 1.5 A2015 2 2.2 A2022 2 3.7 A2037 2 5.5 A2055 2 7.5 A2075 2 0.4 A4004 2 0.75 A4007 2 1.5 A4015 2 2.2 A4022 2 4.0 A4040 2 5.5 A4055 2 7.5 A4075 2 D H1 W H 67 143 80 155 98 176 110 189 D t1 D1 95.5 109.5 2.6 130.5 6 143 80 155 109.5 0.9 55 95.5 67 0.8 27 28 157.5 2.6 132.5 Weight 13 1.5 2.3 2.4 13 0.8 27 0.9 50 1.1 2.2 98 176 110 189 157.5 6 55 164 235 180 250 167.5 1.6 77.5 4.2 130.5 2.6 28 1.5 2.4 2.3 98 164 176 110 189 250 157.5 6 55 167.5 1.6 77.5 2.4 235 180 4.2 W H L X Y M Weight kg AX-FIJ1006-RE 81 40 193 183 57 M4 0.5 AX-FIJ1010-RE 112 47 226 216 88 M4 0.6 AX-FIJ1026-RE 112 47 226 216 88 M4 0.8 AX-FIJ2006-RE 81 50 193 183 57 M4 1.0 Rasmi footprint Filters Filter only needed by the 1-phase 200 V or 3-phase 400 V to comply with C1 EMC class. Rasmi model 1x200 V 3x200 V 3x400 V JX Dimensions AX-FIJ2020-RE 112 50 226 216 88 M4 1.3 AX-FIJ2040-RE 182 55 289 279 150 M5 2.3 AX-FIJ3005-RE 112 45 226 216 88 M4 0.9 AX-FIJ3011-RE 112 45 226 216 88 M4 1.1 AX-FIJ3020-RE 182 45 289 279 150 M4 1.7 9 Input AC Reactor Voltage 200 V 400 V Reference A 120 120 180 120 120 120 AX-RAI02800080-DE AX-RAI00880175-DE AX-RAI00350335-DE AX-RAI07700042-DE AX-RAI03500090-DE AX-RAI01300170-DE B2 70 80 85 70 80 80 Dimensions C2 D 120 80 120 80 190 140 120 80 120 80 120 80 E 52 62 55 52 62 62 F 5.5 5.5 6 5.5 5.5 5.5 Weight kg 1.78 2.35 5.5 1.78 2.35 2.50 DC Reactor Voltage Reference 200 V AX-RC21400016-DE AX-RC10700032-DE AX-RC06750061-DE AX-RC03510093-DE AX-RC02510138-DE A AX-RC01600223-DE AX-RC01110309-DE AX-RC00840437-DE AX-RC43000020-DE 400 V AX-RC27000030-DE AX-RC14000047-DE AX-RC10100069-DE AX-RC06400116-DE AX-RC04410167-DE AX-RC03350219-DE B C Dimensions D E F G H 96 84 113 105 Weight kg 1.22 101 66 5 7.5 2 1.60 116 108 135 124 120 82 6.5 9.5 9.5 136 120 152 135 94 7 146 96 1.95 3.20 5.20 6.00 1.22 84 113 105 101 66 1.60 5 7.5 2 116 108 135 133 120 82 6.5 9.5 9.5 136 120 152 135 94 7 146 1.95 3.70 5.20 6.00 Output AC Reactor Voltage 200 V 400 V Reference AX-RAO11500026-DE AX-RAO07600042-DE AX-RAO04100075-DE AX-RAO03000105-DE AX-RAO01830180-DE AX-RAO01150220-DE AX-RAO00950320-DE AX-RAO16300038-DE AX-RAO11800053-DE AX-RAO07300080-DE AX-RAO04600110-DE AX-RAO03600160-DE A 120 120 120 120 180 180 180 120 120 120 180 180 B2 70 70 80 80 85 85 85 70 80 80 85 85 Dimensions C2 D 120 80 120 80 120 80 120 80 190 140 190 140 205 140 120 80 120 80 120 80 190 140 205 140 E 52 52 62 62 55 55 55 52 52 62 55 55 F 5.5 5.5 5.5 5.5 6 6 6 5.5 5.5 5.5 6 6 L 85 105 W 22 25 Dimensions H X 46 70 62 90 Y - m 5 5 Weight kg 1.78 1.78 2.35 2.35 5.5 5.5 6.5 1.78 2.35 2.35 5.5 6.5 Chokes X Om W Y L H 10 Reference D diameter Motor KW AX-FER2102-RE AX-FER2515-RE 21 25 < 2.2 < 15 Weight kg 0.1 0.2 Od Frequency inverters Installation Standard connections 3-phase 200 VAC 1-phase 200 VAC 3-phase 400 VAC Inverter R (L1) U/T1 S (L2) V/T2 T/N (L3) W/T3 For Source logic P24 4.7 k 5 Motor Note: To connect the DC reactor, remove the short-circuit bar. PD/+1 DC reactor 4 P/+ 3 2 1 N/PCS AL1 L AL2 AL0 Frequency meter AM H Frequency setting unit 1 to 2 k 11 10 VDC Relay output Common RY O 10 k OI L Power supply input 4 to 20 mA DC 250 24 VDC CM2 Terminal Block Specifications Terminal Name Main circuit power supply input R/L1, S/L2, T/N/L3 U/T1, V/T2, W/T3 PD/+1, P/+ P/+, N/- JX Inverter output External DC reactor terminal Function (signal level) Used to connect line power to the drive. Drives with single-phase 200 V input power use only terminals R/L1 and N (T/L3), terminal S/L2 is not available for these units Used to connect the motor DC bus terminal Normally connected by the short-circuit bar. Remove the short-circuit bar between +1 and P/+2 when a DC reactor is connected. - Grounding For grounding (grounding should conform to the local grounding code.) 11 Control Circuit Type Monitor Signal Digital output signals Analog input signal Digital input signals Signal name Function Signal level PCS Input power supply External power supply terminal for input signal (input) ...At sink logic Internal power supply output terminal for input signal (output) ...At source logic 24 VDC 10% P24 Internal 24 VDC 24 VDC internal power supply 24 VDC10% 100 mA 1 Multi-function Input selection 1 Factory setting: Forward/ Stop 2 Multi-function Input selection 2 Factory setting: Reverse/ Stop 3 Multi-function Input selection 3 Factory setting: Fault reset 4 Multi-function Input selection 4 Factory setting: Emergency stop fault 5 Multi-function Input selection 5 Factory setting: Multi-step speed reference 1 L Multi-function Input selection common -- H Frequency reference power supply 10 VDC 10 mA max O Voltage frequency reference signal 0 to 10 VDC (10 K) OI Current frequency reference signal 4 to 20 mA (250 ) L Frequency reference common -- No. AL2 NC output AL1 NO output AL0 Relay Output common Factory default relay settings Under normal operation: AL2-AL0 Closed Under abnormal operation or power shutdown: AL1-AL0 Open 250 VAC 2.5 A 30 VDC 3 A 250 VAC 1 A 30 VDC 1 A Multi-function output terminal Factory setting: Frequency arrival signal at a constant speed CM2 Output signal common -- AM Analog frequency monitor/Analog output current monitor Factory setting: Analog frequency monitor 11 -- 27 VDC 50 mA max 0 to 10 VDC 1 mA Side by side mounting 12 Frequency inverters Input AC Reactor AC reactor Power supply 3 phase 200 V class Max. applicable Current value Reference motor output kW A 0.1 to 1.5 AX-RAI02800080-DE 8.0 2.2 to 3.7 AX-RAI00880175-DE 17.5 5.5 to 7.5 AX-RAI00350335-DE 33.5 MCCB Inductance mH 2.8 0.88 0.35 JX U X R/L1 V Y S/L2 W Z T/L3 Max. applicable motor output kW 0.4 to 1.5 2.2 to 4.0 5.5 to 7.5 400 V class Current value A 4.2 AX-RAI07700042-DE AX-RAI03500090-DE 9.0 17.0 AX-RAI01300170-DE Reference Inductance mH 7.7 3.5 1.3 DC Reactor JX Power supply MCCB R/L1 S/L2 T/L3 +1 P/+2 DC reactor Max. applicable motor output kW 0.2 0.4 0.7 1.5 2.2 3.7 5.5 7.5 200 V class Current value A AX-RC21400016-DE 1.6 AX-RC10700032-DE 3.2 AX-RC06750061-DE 6.1 AX-RC03510093-DE 9.3 AX-RC02510138-DE 13.8 AX-RC01600223-DE 22.3 AX-RC01110309-DE 30.9 AX-RC00840437-DE 43.7 Reference Inductance mH 21.4 10.7 6.75 3.51 2.51 1.60 1.11 0.84 Max. applicable motor output kW 0.4 0.7 1.5 2.2 4.0 5.5 7.5 400 V class Current value A 2.0 AX-RC43000020-DE AX-RC27000030-DE 3.0 4.7 AX-RC14000047-DE AX-RC10100069-DE 6.9 AX-RC06400116-DE 11.6 AX-RC04410167-DE 16.7 AX-RC03350219-DE 21.9 Reference Inductance mH 43.0 27.0 14.0 10.1 6.40 4.41 3.35 Output AC Reactor Max. applicable motor output kW 0.1 to 0.4 0.75 1.5 2.2 3.7 5.5 7.5 JX 200 V class Current value A AX-RAO11500026-DE 2.6 AX-RAO07600042-DE 4.2 AX-RAO04100075-DE 7.5 AX-RAO03000105-DE 10.5 AX-RAO01830160-DE 16.0 AX-RAO01150220-DE 22.0 AX-RAO00950320-DE 32.0 Reference Inductance mH 11.50 7.60 4.10 3.00 1.83 1.15 0.95 Max. applicable motor output kW 0.4 to 1.5 2.2 4.0 5.5 7.5 400 V class Current value A 3.8 AX-RAO16300038-DE AX-RAO11800053-DE 5.3 8.0 AX-RAO07300080-DE AX-RAO04600110-DE 11.0 AX-RAO03600160-DE 16.0 Reference Inductance mH 16.30 11.80 7.30 4.60 3.60 - 13 Ordering information Power supply D B MCCB CX-Drive CX-One USB cable A AC reactor A B B LCD 5 lines remote operator Remote operator extension cable * Filter C JX C C A A Choke DC reactor C A Motor Output reactor Ground * Only needed for 3 phase 200 V or to comply C1 on 3 phase 400 V models 3G3JX Specifications Voltage class Single-phase 200 V Three-phase 200 V Three-phase 400 V 14 Max. applicable motor output kW Model Rated output current (A) Standard 0.2 1.4 3G3JX-AB002-EF 0.4 2.6 3G3JX-AB004-EF 0.75 4 3G3JX-AB007-EF 1.5 7.1 3G3JX-AB015-EF 2.2 10 3G3JX-AB022-EF 0.2 1.4 3G3JX-A2002-E 0.4 2.6 3G3JX-A2004-E 0.75 4 3G3JX-A2007-E 1.5 7.1 3G3JX-A2015-E 2.2 10 3G3JX-A2022-E 3.7 15.9 3G3JX-A2037-E 5.5 24 3G3JX-A2055-E 7.5 32 3G3JX-A2075-E 3G3JX-A4004-EF 0.4 1.5 0.75 2.5 3G3JX-A4007-EF 1.5 3.8 3G3JX-A4015-EF 2.2 5.5 3G3JX-A4022-EF 4.0 8.6 3G3JX-A4040-EF 5.5 13 3G3JXA4055-EF 7.5 16 3G3JXA4075-EF Frequency inverters A Line filters Line filter Rasmi Inverter Voltage Model 3G3JX-@ Reference Rated current (A) AB002 / AB004 AX-FIJ1006-RE 6 0.5 AB007 AX-FIJ1010-RE 10 0.6 0.8 1-Phase 200 VAC 3-Phase 200 VAC Weight (kg) AB015 / AB022 AX-FIJ1026-RE 26 A2002 / A2004 / A2007 AX-FIJ2006-RE 6 1.0 A2015 / A2022 / A2037 AX-FIJ2020-RE 20 1.3 2.3 A2055 / A2075 AX-FIJ2040-RE 40 A4004 / A4007 /A4015 AX-FIJ3005-RE 5 0.9 A4022 /A4040 AX-FIJ3011-RE 11 1.1 A4055 / A4075 AX-FIJ3020-RE 20 1.7 3-Phase 400 VAC A Input AC Reactors AC Reactor Inverter Voltage 3-Phase 200 VAC Model 3G3JX-@ Reference A2002 / A2004 / A2007 AX-RAI02800080-DE A2015 / A2022 / A2037 AX-RAI00880175-DE A2055 / A2075 AX-RAI00350335-DE AB002 / AB004 1-Phase 200 VAC AB007 Under development AB015 / AB022 A4004 / A4007 / A4015 AX-RAI07700042-DE A4022 / A4040 AX-RAI03500090-DE A4055 / A4075 AX-RAI01300170-DE 3-Phase 400 VAC A DC Reactors 200V 3-phase 200V single phase DC Reactor 400V 3-phase Inverter DC Reactor AX-RC10700032-DE 3G3JX-A2002 AX-RC21400016-DE 3G3JX-AB004 AX-RC06750061-DE 3G3JX-A2004 AX-RC10700032-DE 3G3JX-A4004 3G3JX-AB007 AX-RC03510093-DE 3G3JX-A2007 AX-RC06750061-DE 3G3JX-A4007 AX-RC27000030-DE 3G3JX-AB015 AX-RC02510138-DE 3G3JX-A2015 AX-RC03510093-DE 3G3JX-A4015 AX-RC14000047-DE 3G3JX-AB022 AX-RC01600223-DE 3G3JX-A2022 AX-RC02510138-DE 3G3JX-A4022 AX-RC10100069-DE 3G3JX-A2037 AX-RC01600223-DE 3G3JX-A4040 AX-RC06400116-DE 3G3JX-A2055 AX-RC01110309-DE 3G3JX-A4055 AX-RC04410167-DE 3G3JX-A2075 AX-RC00840437-DE 3G3JX-A4075 AX-RC03350219-DE Inverter 3G3JX-AB002 - A Chokes DC Reactor Inverter - AX-RC43000020-DE B Accessories Description AX-FER2102-RE 21 For 2.2 KW motors or below AX-FER2515-RE 25 For 7.5 KW motors or below A Output AC Reactors AC Reactor Inverter Voltage Model 3G3JX-@ Reference A2001 / A2002 / A2004 AB001 / AB002 / AB004 AX-RAO11500026-DE A2007/AB007 AX-RAO07600042-DE A2015 / AB015 AX-RAO04100075-DE A2022 / AB022 AX-RAO03000105-DE A2037 AX-RAO01830160-DE A2055 AX-RAO01150220-DE A2075 AX-RAO00950320-DE A4004 / A4007 / A4015 AX-RAO16300038-DE A4022 AX-RAO11800053-DE A4040 AX-RAO07300080-DE A4055 AX-RAO04600110-DE A4075 AX-RAO03600160-DE 200 VAC *1 Model Functions 5 Line LCD remote operator LCD remote with copy function, AX-OP05-E operator cable length max. 3m.*1 Remote operator 3 meters cable for connecting 3G3AX-CAJOP300-EE cable remote operator LED remote LED remote operator, cable 3G3AX-OP01 operator length max. 3m Mounting kit for Mounting kit for LED operator 4X-KITMINI LED operator on panel 3G3AX-PCACN2 USB converter / RJ45 to USB connection USB cable cable USB-convertercable 3G3AX-CTB020-EE 3G3AX-CTR150-EE Description RJ45 T-Branch cable RJ45 Terminator resistor T cable for RS-422 connection Terminator resistor for RS-422 connection Please note, for 3G3JX inverters models, the operator will only display 2 lines of text. D Computer software Types Software 400 VAC Types Digital operator Diameter Accessories Model Model Description Installation CX-Drive Computer software Configuration and monitoring software tool CX-One Computer software Configuration and monitoring software tool Saver Computer software Software tool for Energy Saving calculation ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. I110E-EN-02 JX In the interest of product improvement, specifications are subject to change without notice. 15 OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 industrial.omron.eu Austria Tel: +43 (0) 2236 377 800 industrial.omron.at Germany Tel: +49 (0) 2173 680 00 industrial.omron.de Portugal Tel: +351 21 942 94 00 industrial.omron.pt Turkey Tel: +90 212 467 30 00 industrial.omron.com.tr Belgium Tel: +32 (0) 2 466 24 80 industrial.omron.be Hungary Tel: +36 1 399 30 50 industrial.omron.hu Russia Tel: +7 495 648 94 50 industrial.omron.ru United Kingdom Tel: +44 (0) 870 752 08 61 industrial.omron.co.uk Czech Republic Tel: +420 234 602 602 industrial.omron.cz Italy Tel: +39 02 326 81 industrial.omron.it South Africa Tel: +27 (0)11 579 2600 industrial.omron.co.za Denmark Tel: +45 43 44 00 11 industrial.omron.dk Netherlands Tel: +31 (0) 23 568 11 00 industrial.omron.nl Spain Tel: +34 913 777 900 industrial.omron.es Finland Tel: +358 (0) 207 464 200 industrial.omron.fi Norway Tel: +47 (0) 22 65 75 00 industrial.omron.no Sweden Tel: +46 (0) 8 632 35 00 industrial.omron.se France Tel: +33 (0) 1 56 63 70 00 industrial.omron.fr Poland Tel: +48 22 458 66 66 industrial.omron.pl Switzerland Tel: +41 (0) 41 748 13 13 industrial.omron.ch More Omron representatives industrial.omron.eu Automation Systems * Programmable logic controllers (PLC) * Human machine interfaces (HMI) * Remote I/O * Industrial PC's * Software Motion & Drives * Motion controllers * Servo systems * Inverters * Robots Control Components * Temperature controllers * Power supplies * Timers * Counters * Programmable relays * Digital panel indicators * Electromechanical relays * Monitoring products * Solid-state relays * Limit switches * Pushbutton switches * Low voltage switch gear Sensing & Safety * Photoelectric sensors * Inductive sensors * Capacitive & pressure sensors * Cable connectors * Displacement & width-measuring sensors * Vision systems * Safety networks * Safety sensors * Safety units/relay units * Safety door/guard lock switches KPP_JX_EN_INT03 Although we strive for perfection, Omron Europe BV and/or its subsidiary and affiliated companies do not warrant or make any representations regarding the correctness or completeness of the information described in this document. We reserve the right to make any changes at any time without prior notice. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: 3G3AX-RAI02800080-DE