Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
200235 Rev. B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • June 8, 2006 1
HY22-73, HY22-73LF: 90-Degree Hybrid 2.1–2.3 GHz
DATA SHEET
Parameter Frequency Min. Typ. Max. Unit
Frequency 2.1 2.3 GHz
Insertion loss less 3 dB split 0.55 0.7 dB
Isolation 20 23 dB
Input VSWR 1.2:1 1.5:1
Output VSWR 1.2:1 1.5:1
Amplitude balance ±0.4 ±1.1 dB
Phase balance ±2 ±4 Deg.
Electrical Specifications at 25 °C
ZO= 50 , unless otherwise noted
Features
Low cost
Low profile
Small SOT-6 package
Available on tape and reel
Available lead (Pb)-free and RoHS-compliant MSL-1 @ 260 °C
per JEDEC J-STD-020
Description
The HY22-73 is a 50 , 90-degree hybrid tuned for the
2.1–2.3 GHz band. The monolithic circuitry is 100% passive
and offers low loss, high isolation and exceptional phase/
amplitude balance. It is available in the SOT-6 surface
mount package. HY22-73LF is packaged in a lead (Pb)-free,
fully RoHS-compliant SOT-6 package and is electrically identical
to HY22-73.
In
Termination
Direct
Coupled
Block Diagram
Skyworks offers lead (Pb)-free, RoHS (Restriction of
Hazardous Substances)-compliant packaging.
NEW
-5.0
-4.5
-4.0
-3.5
-3.0
-2.5
1.9 2.0 2.1 2.2 2.3 2.4 2.5
Loss (dB)
Frequency (GHz)
Path Losses vs. Frequency
Direct
Coupled
-2.0
1.0
0.5
0
-0.5
-1.0
-1.5
1.5
2.0
1.9 2.0 2.1 2.2 2.3 2.4 2.5
Balance (dB)
Frequency (GHz)
Amplitude Balance vs. Frequency
1.05
1.00
1.10
1.15
1.20
1.25
1.30
1.9 2.0 2.1 2.2 2.3 2.4 2.5
VSWR (:1)
Frequency (GHz)
Input VSWR vs. Frequency
1.00
1.20
1.18
1.16
1.14
1.12
1.10
1.08
1.06
1.04
1.02
1.9 2.0 2.1 2.2 2.3 2.4 2.5
VSWR (:1)
Frequency (GHz)
Output VSWR vs. Frequency
Direct
Coupled
Typical Performance Data
ZO= 50 , unless otherwise noted
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
June 8, 2006 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200235 Rev. B
DATA SHEET • HY22-73, HY22-73LF
2
The Pin Out diagram shows the HY22-73 configured for a
divider/coupler with Pin 1 as the input port and a 50
termination to be placed at Pin 3. Since the HY22-73 is
symmetric, any nonground pin may be used as the input
port. The following table shows the possible pin connection
combinations for the HY22-73 used as a divider/coupler:
In
GND
Termination
Direct
GND
Coupled
12 3
65 4
Pin Out
Input Termination Direct Coupled
Pin 1 Pin 3 Pin 6 Pin 4
Pin 3 Pin 1 Pin 4 Pin 6
Pin 4 Pin 6 Pin 3 Pin 1
Pin 6 Pin 4 Pin 1 Pin 3
DATA SHEET • HY22-73, HY22-73LF
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
200235 Rev. B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • June 8, 2006 3
87.0
88.5
88.0
87.5
89.0
1.9 2.0 2.1 2.2 2.3 2.4 2.5
Phase (Degrees)
Frequency (GHz)
Coupled-Direct Phase vs. Frequency
-33
-19
-21
-23
-25
-27
-29
-31
1.9 2.0 2.1 2.2 2.3 2.4 2.5
Isolation (dB)
Frequency (GHz)
Isolation vs. Frequency
Characteristic Value
Input power(1) 2 W CW
Input power(2) 1 W CW
Operating temperature -40 °C to +85 °C
Storage temperature -65 °C to +150 °C
Absolute Maximum Ratings
0.074
(1.90 mm) Ref.
0.071 (1.80 mm)
0.052 (1.30 mm)
0.037 (0.95 mm) Ref.
0.122 (3.10 mm)
0.106 (2.70 mm)
0.006
(0.15 mm)
0.000
(0.00 mm)
0.057 (1.45 mm)
0.035 (0.90 mm)
0.020 (0.51 mm)
0.014 (0.350 mm)
0.126 (3.20 mm)
0.087 (2.20 mm)
Pin 6
Pin 1
Pin 1
Indicator
0.022 (0.61 mm)
0.004 (0.10 mm)
0.014
(0.26 mm)
0.004
(0.10 mm)
0.012
(0.30 mm)
Typ.
5.0° ± 1°
5.0° ± 1°
SOT-6
0.091
0.020
0.018
To 50
Termination
In
Coupled
Direct
HY22
Recommended Board Layout
1. When used as a power divider with a 2.0:1 maximum VSWR on all ports.
2. When used as a power combiner with a 2.0:1 maximum VSWR on all ports.
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
CAUTION: Although this device is designed to be as robust as
possible, ESD (Electrostatic Discharge) can damage
this device. This device must be protected at all times
from ESD. Static charges may easily produce poten-
tials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.
Material is FR-4. Dimensions are in inches.
Recommended Solder Reflow Profiles
Refer to the “Recommended Solder Reflow Profile”
Application Note.
T
ape and Reel Information
Refer to the “Discrete Devices and IC Switch/Attenuators
Tape and Reel Package Orientation” Application Note.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
June 8, 2006 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200235 Rev. B
DATA SHEET • HY22-73, HY22-73LF
4
Copyright © 2002, 2003, 2004, 2005, 2006, Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided
by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and
Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and
names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are
incorporated by reference.