LC24 Counters DIN HALF SIZE LCD DISPLAY COUNTER * Large 7-digit display * Leading "0"s in the display are eliminated for easy reading * Wide counting range PRODUCT TYPE 1) Non-voltage input type Types LC24-F Flush mounting type LC24-C PC board mounting type Part No. Without With manual reset manual reset Rated operating voltage Max. current consumption LC24-F LC24-F-N Built-in battery (Battery life: 10 years) --- LC24-C --- 3V DC (Uses manganese dioxide lithium battery) 20 A (When resetting: 200 A) Rated operating voltage No. of digits No. of digits Counting speed Input 7 30 cps Non-voltage input 2) Voltage input type Types Part No. With Without manual reset manual reset LC24-F-AL LC24-F Flush mounting type Counting speed Input 100 to 120V AC/DC (Signal reset is controlled by non-voltage type input) LC24-F-AL-N Built-in battery (Battery life: 6 years) LC24-F-AH LC24-F-AH-N LC24-F-DL LC24-F-DL-N 30 cps 200 to 240V AC/DC (Signal reset is controlled by non-voltage type input) 7 Built-in battery (Battery life: 10 years) 4.5 to 30V DC 70 cps SPECIFICATIONS Input signals Non-voltage input type Flush mounting type Min. operating signal width Voltage input type PC board mounting type AC/DC input type 7.15 ms (ON:OFF = 1:1) 16.7 ms (ON:OFF = 1:1) ON: Operation signal Input method Non-voltage input: Contact/Open collector 20ms Input method 10 k --- 20ms ON: 4.5 to 30V DC OFF: 0 to 2V DC Max. 1 k when short-circuited Min. 100 k when open-circuited Residual voltage 60 500ms Non-voltage input: Contact/Open collector Input impedance Manual reset min. input width ON: 4.5 to 30V DC OFF: 0 to 2V DC Max. 0.5 V Residual voltage Signal reset 100 to 120V AC/DC, 200 to 240V AC/DC OFF: 0 to 2V AC/DC Max. 1 k when short-circuited Min. 100 k when open-circuited Input impedance Min. signal reset width DC input type 7.5 k Max. 0.5V 20ms 500ms --- 20ms Characteristics Non-voltage input type Voltage input type LC24-F Flush-mounting type LC24-C PC board mounting type Built-in battery 3V DC (manganese dioxide lithium battery) 10 years --- Rated operating voltage Battery life AC/DC input type DC input type Built-in battery 6 years 10 years 10G (4 times on 3 axes) Shock resistance Functional Destructive 30G (5 times on 3 axes) Vibration resistance Functional 10 to 55 Hz: 1 cycle/min double amplitude of 0.3 mm (10 min on 3 axes) Destructive 10 to 55 Hz: 1 cycle/min double amplitude of 0.75 mm (1 h on 3 axes) Ambient temperature -10 to +55C +14 to 131F Storage temperature -25 to +65C +13 to 149F Ambient humidity 35 to 85% RH Counting direction Addition (UP) mm (inch) DIMENSIONS LC24-F, flush mounting type (Common for non-voltage input type and voltage input type) 44.5 1.752 M3.5 self-up terminal screw Reset push-key switch* COUNTER 38.9 1.531 Panel cutout dimensions LC24 24 .945 22.2 +0 0.3 .874+0.012 22 .866 RESET 4.5 48 1.890 .177 *Without reset push key switch is also available 28.8 1.134 10.1 .398 45+0 0.6 1.772+0.024 Panel thickness: 1-4.5 mm WIRING DIAGRAM 1) Non-voltage input type 2) Voltage input type * AC/DC voltage input Contact input (1) Reset terminal (contact input) Counting input Reset input 1 3 2 4 Counting input (2) Reset terminal (open collector input) Reset input 1 3 2 4 Counting input or Reset input 1 3 2 4 or 0V * Timing input terminals ( 1 , 2 ) and reset input terminals ( 3 , 4 ) are insulated internally. Open collector input Counting input * DC voltage input (1) Contact input Reset input 1 +V 0V 2 Reset input 1 3 2 4 +V Counting input +V 0V 4 0V Note: 2 (2) Open collector input Counting input 3 4 are connected internally. * Terminal 2 0V 0V 3.3 .130 33.02 1.300 COUNTER LC24 2.54 .100 15.24 .600 RESET Reset push-key switch 42.2 1.661 0.3 .012 4.6 .181 WIRING DIAGRAM Contact input 17 26 Open collector input 28 Signal input Reset input 14 12 3 1 15 17 26 28 14 12 3 1 Signal input 0V 1.9 .075 15.24 .600 1.9 .075 4.6 5.08 5.08 .200 .200 .181 33.02 1.300 Compatible 28-pin dip terminal Reset input Note: 15 3 V DC lithium battery 4 Main body's 8-0.8 dia. 2.54 occupied section 8-.031 dia. .100 19 .748 15 2 +V PC board pattern (Bottom view) 5.08 .200 Dip terminal x8 0.5 .020 17.1 .673 3 (Voltage signal is recognized when the transistor is switched to OFF.) 4 are connected internally. LH24-C, PC board mounting type 5.08 .200 0.6 .024 Reset input 1 3 V DC lithium battery 1 3 , 12 17 , and 26 14 28 are connected internally. 61 OPERATION EXPLANATION LC24-F type * Counts when the operation signal is ON. * While the reset input is ON, the signal time is not counted and the display is "0". Addition UP LC24-C type * Counts when the operation signal is ON. * While the reset input is ON, the signal does not change. CAUTIONS 1. Since the current from the operation signal and reset input terminals [1-3 (flush mounting type), E-H (PC board mounting type)] is small, use relays and switches which have high-reliability contact performance. 2. When input signals are triggered through the transistor's open collector, use a small signal transistor with an ICBO less than 1 A, being sure to trigger them with no voltage across the collector. 3. When connecting the signal input and reset input wires, do not run them parallel to high-voltage or power cables and avoid using the same conduit. Use shielded wires or metallic conduits which are as short as possible. If the floating capacitance of the wires exceeds 500 pF (approx. 10 m for parallel wires of 2 mm2), it will cause malfunctions. 4. Lithium batteries are built in the flush mounting types. Never throw them into a fire. Do not dispose of them in trash intended to be incinerated. *PC board mounting type-- 1. After connecting the external power, be sure to reset it to make sure that "0" appears on the display. 2. Battery life is calculated as follows: t=A I t: Battery life (h) I: Consumption current (mA) A: Battery capacity when the operating voltage becomes minimum. 3. Hand soldering: Soldering iron Iron tip temperature Soldering time 62 30 W to 60 W Approx. 300C (572F) Less than approx. 3 seconds Example IN Reset Count 1 0 9999999 0 1 0 Example IN Reset Count 0 1 * AC/DC Voltage input type 1. Apply voltage to the signal input terminal. Do not apply voltage to the reset input terminal. When voltage exceeding the range of the rated input voltage is applied to the signal input terminal, or if voltage is applied to the reset terminal, it may cause break-down of internal elements. 2. Since the current from the reset input terminal is small, use relays and switches which have high-reliability contact performance. 3. When reset is triggered through the transistor's open collector, use a small signal transistor with an ICBO less than 1 A, being sure to trigger it with no voltage across the collector. 4. For external reset, make a temporary short-circuit between the rear reset terminals [3-4]. * DC voltage input type 1.When more than 30 V DC is applied to the signal or reset input terminals, it may cause breakdown of internal elements. 2. For external reset, voltage is applied between the rear reset terminals [3-4] to the H level (4.5 to 30 V DC). In this case, connect (-) to terminal 4 and (+) to terminal 3]. Since they are polarized, they will not operate with reverse polarity. 9999999 0 1 0 * Common 1. When connecting the operation signal wires [1-2] and reset input wires [3-4], do not run them in parallel with high-voltage or power cables. Avoid running signal or reset wires in a power conduit. Use shielded wires or metal conduits which are as short as possible. If the floating capacitance of these wires exceeds 500 pF (approximately 10 m for parallel wires of 2 mm2), it will cause malfunctions. 2. Lithium batteries are built in. Never throw them into a fire. Do not dispose of them in trash intended to be incinerated.