V15
1
TRG500V SERIES
6W SWITCHING
ADAPTER
Features
* Universal Input Range 90~264VAC
* Meets EN55022 Class B and
CISPR/FCC Class B, Conducted
* Continuous Short Circuit Protection
* Over Voltage Protection
* Meet CEC & ErP Level V
(Output Cable Length1800mm)
TRG5XX - X - XX X XX
Model No. AC Plug Type DC Plug Type OVP DC Cable Length and Type
A: USA 2 Pin E: With OVP 01: 720mm
E: Europe 2 Pin 02: 1220mm
U: British 3 Pin 03: 1800mm
S: Australia 2 Pin 11: 720mm with Ferrite Core
12: 1220mm with Ferrite Core
13: 1800mm with Ferrite Core
* 20AWG / UL2468
Ordering information
MODEL OUTPUT
VOLTAGE OUTPUT
CURRENT
RIPPLE &
NOISE
NOTE 2
VOLTAGE
ACCURACY
NOTE 1
LINE
REGULATION
NOTE 3
LOAD
REGULATION
NOTE 4
% EFF. (Typ.)
NOTE 5
TRG501-15V
15V 400mA 1% ±3% ±1% ±2% 68%
TRG501V 12V 500mA 1% ±3% ±1% ±2% 68%
TRG502V 10V 600mA 1% ±3% ±1% ±2% 68%
TRG503V 9V 650mA 1% ±3% ±1% ±2% 68%
TRG506V 8V 650mA 1% ±3% ±1% ±3% 67%
TRG507V 7.5V 650mA 1% ±3% ±1% ±3% 67%
TRG508V 7.0V 650mA 1% ±3% ±1% ±3% 67%
TRG510V 6.5V 650mA 1% ±3% ±1% ±3% 67%
TRG511-1V 6.0V 1000mA 1% ±3% ±1% ±4% 67%
TRG513-1V 5.0V 1200mA 1% ±3% ±1% ±4% 66%
Specifications are subject to change without notice.
V15
2
S
pecifications
TRG500
V
Series Derating Curve
INPUT SPECIFICATIONS:
Voltage …....………........…...................................................... 90~264Vac
Frequency ………………………………………….……………..... 50 to 60Hz
Input Current ………………….…………….................................... 0.5A max.
Inrush Current …………………...... Cold Start @2550A max. @240Vac
Leakage Current …………………………………………….…… 0.25mA max.
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 10ms typ. @115Vac
Short Circuit Protection ………………………… Continuous(Auto Recovery)
Over Voltage Protection …………………...........................................… Yes
Temperature Coefficient …………………….............................… ±0.05%/
GENERAL SPECIFICATIONS:
NOTE:
Isolation ………………………………………… Input to output = 4,242VDC
1. Voltage accuracy at 60% full load.
Operating Temperature ............................... 0 ~ 60 (see derating curve)
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Storage Temperature ……………………………...….......…........ -20 ~ 85
Ripple & Noise measurement @20MHz BW.
Humidity …………………...….......……........ 93% RH max. Non condensing
3. Line regulation measured from 100Vac to 240Vac, full load.
Cooling …………………………………….………………. Natural Convection
4. Load regulation measured from 60% to full load and from 60% to
Switching Frequency ………………………………………… 87KHz Typical
20% full load (60% +/- 40% full load).
MTBF …… MIL-HDBK-217F, GB, at 25/115VAC ………. 200K hrs min.
5. Typical efficiency at 230VAC and full load at 25 .
Altitude …………………………………………………………………… 2000m
6. ”Various TR Series adapters are PSE certified. PSE certification
Dimensions …….…….. 2.835x2.047x1.378inches (72.00x52.00x35.00mm)
alone is not sufficient for importation into Japan. A valid PSE mark
Weight …………………………………………………….. 135g (0.30Pounds)
must contain the name of the importer as shown in the example below.
SAFETY AND EMC:
If PSE mark is required, the name of the registered importer must be
Emission and lmmunity ………… EN55022 Class B, FCC Part 15 Class B
supplied to Cincon on order placement. Product labels will not contain
EN61000-6-3,EN61000-3-2,EN61000-3-3
PSE mark if importer name is not supplied. Consult factory or local
EN55024, EN61204-3, EN61000-6-1
represent tative for details”
Safety ………………..……………… IEC60950-1, EN60950-1, UL60950-1
Mechanical Specification
Millimeters:X.XX±0.5
Tolerance:Inches:X.XXX±0.02
All Dimensions are in inches(mm)
FIG.S
FIG.A
FIG.U
FIG.E
70.866[1800.00]±1.969[50.00]
70.866[1800.00]±1.969[50.00]
2.047[52.00]
3.307[84.00]
0.669[17.00]±0.011[0.30]
0.342[8.68]±0.019[0.50]
2.835[72.00]
1.378[35.00]
2.047[52.00]
70.866[1800.00]±1.969[50.00]
0.500[12.70]±0.011[0.30]
0.669[17.00]±0.031[0.80]
2.713[68.91]
2.835[72.00]
1.378[35.00]
2.047[52.00]
0.688[17.50]±0.019[0.50]
0.748[19.00]±0.011[0.30]
3.529[89.65]
2.835[72.00]
1.378[35.00]
0.539[13.70]±0.027[0.70]
70.866[1800.00]±1.969[50.00]
3.396[86.26]
0.692[17.60]±0.023[0.60]
MAX0.372[9.45]
2.047[52.00]
2.835[72.00]
1.378[35.00]
0%
20%
40%
60%
80%
100%
0 10 20 30 40 50 60
Ambient Temperature(
o
C)
Rated Load(%)
20LFM(Natural Convection)
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Cincon:
TRG501-15V-A-11E03 TRG501-15V-A-12E03 TRG501V-A-11E03 TRG501V-A-12E03 TRG501V-E-11E03
TRG501V-E-12E03 TRG501V-S-11E03 TRG501V-S-12E03 TRG501V-U-11E03 TRG501V-U-12E03 TRG502V-A-
11E03 TRG502V-A-12E03 TRG502V-E-11E03 TRG502V-E-12E03 TRG502V-S-11E03 TRG502V-S-12E03
TRG502V-U-11E03 TRG502V-U-12E03 TRG503V-A-11E03 TRG503V-A-12E03 TRG503V-E-11E03 TRG503V-E-
12E03 TRG503V-S-11E03 TRG503V-S-12E03 TRG503V-U-11E03 TRG503V-U-12E03 TRG506V-A-11E03
TRG506V-A-12E03 TRG506V-E-11E03 TRG506V-E-12E03 TRG506V-S-11E03 TRG506V-S-12E03 TRG506V-U-
11E03 TRG506V-U-12E03 TRG507V-A-11E03 TRG507V-A-12E03 TRG507V-E-11E03 TRG507V-E-12E03
TRG507V-S-11E03 TRG507V-S-12E03 TRG507V-U-11E03 TRG507V-U-12E03 TRG508V-A-11E03 TRG508V-A-
12E03 TRG508V-E-11E03 TRG508V-E-12E03 TRG508V-S-11E03 TRG508V-S-12E03 TRG508V-U-11E03
TRG508V-U-12E03 TRG510V-A-11E03 TRG510V-A-12E03 TRG510V-E-11E03 TRG510V-E-12E03 TRG510V-S-
11E03 TRG510V-S-12E03 TRG510V-U-11E03 TRG510V-U-12E03 TRG511-1V-A-11E03 TRG511-1V-A-12E03
TRG511-1V-E-11E03 TRG511-1V-E-12E03 TRG511-1V-S-11E03 TRG511-1V-S-12E03 TRG511-1V-U-11E03
TRG511-1V-U-12E03 TRG513-1V-A-11E03 TRG513-1V-A-12E03 TRG513-1V-E-11E03 TRG513-1V-E-12E03
TRG513-1V-S-11E03 TRG513-1V-S-12E03 TRG513-1V-U-11E03 TRG513-1V-U-12E03 TRG501-15V-A-01E03
TRG501-15V-A-02E03 TRG501V-A-01E03 TRG501V-A-02E03 TRG501V-E-01E03 TRG501V-E-02E03 TRG501V-S-
01E03 TRG501V-S-02E03 TRG501V-U-01E03 TRG501V-U-02E03 TRG502V-A-01E03 TRG502V-A-02E03
TRG502V-E-01E03 TRG502V-E-02E03 TRG502V-S-01E03 TRG502V-S-02E03 TRG502V-U-01E03 TRG502V-U-
02E03 TRG503V-A-01E03 TRG503V-A-02E03 TRG503V-E-01E03 TRG503V-E-02E03 TRG503V-S-01E03
TRG503V-S-02E03 TRG503V-U-01E03 TRG503V-U-02E03