V15
2
INPUT SPECIFICATIONS:
Voltage …....………........…...................................................... 90~264Vac
Frequency ………………………………………….……………..... 50 to 60Hz
Input Current ………………….…………….................................... 0.5A max.
Inrush Current …………………...... Cold Start @25℃ 50A max. @240Vac
Leakage Current …………………………………………….…… 0.25mA max.
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 10ms typ. @115Vac
Short Circuit Protection ………………………… Continuous(Auto Recovery)
Over Voltage Protection …………………...........................................… Yes
Temperature Coefficient …………………….............................… ±0.05%/℃
GENERAL SPECIFICATIONS:
NOTE:
Isolation ………………………………………… Input to output = 4,242VDC
1. Voltage accuracy at 60% full load.
Operating Temperature ............................... 0 ~ 60℃ (see derating curve)
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Storage Temperature ……………………………...….......…........ -20 ~ 85℃
Ripple & Noise measurement @20MHz BW.
Humidity …………………...….......……........ 93% RH max. Non condensing
3. Line regulation measured from 100Vac to 240Vac, full load.
Cooling …………………………………….………………. Natural Convection
4. Load regulation measured from 60% to full load and from 60% to
Switching Frequency ………………………………………… 87KHz Typical
20% full load (60% +/- 40% full load).
MTBF …… MIL-HDBK-217F, GB, at 25℃/115VAC ………. 200K hrs min.
5. Typical efficiency at 230VAC and full load at 25 .℃
Altitude …………………………………………………………………… 2000m
6. ”Various TR Series adapters are PSE certified. PSE certification
Dimensions …….…….. 2.835x2.047x1.378inches (72.00x52.00x35.00mm)
alone is not sufficient for importation into Japan. A valid PSE mark
Weight …………………………………………………….. 135g (0.30Pounds)
must contain the name of the importer as shown in the example below.
SAFETY AND EMC:
If PSE mark is required, the name of the registered importer must be
Emission and lmmunity ………… EN55022 Class B, FCC Part 15 Class B
supplied to Cincon on order placement. Product labels will not contain
EN61000-6-3,EN61000-3-2,EN61000-3-3
PSE mark if importer name is not supplied. Consult factory or local
EN55024, EN61204-3, EN61000-6-1
represent tative for details”
Safety ………………..……………… IEC60950-1, EN60950-1, UL60950-1
Millimeters:X.XX±0.5
Tolerance:Inches:X.XXX±0.02
All Dimensions are in inches(mm)
FIG.S
FIG.A
FIG.U
FIG.E
70.866[1800.00]±1.969[50.00]
70.866[1800.00]±1.969[50.00]
2.047[52.00]
3.307[84.00]
0.669[17.00]±0.011[0.30]
0.342[8.68]±0.019[0.50]
2.835[72.00]
1.378[35.00]
2.047[52.00]
70.866[1800.00]±1.969[50.00]
0.500[12.70]±0.011[0.30]
0.669[17.00]±0.031[0.80]
2.713[68.91]
2.835[72.00]
1.378[35.00]
2.047[52.00]
0.688[17.50]±0.019[0.50]
0.748[19.00]±0.011[0.30]
3.529[89.65]
2.835[72.00]
1.378[35.00]
0.539[13.70]±0.027[0.70]
70.866[1800.00]±1.969[50.00]
3.396[86.26]
0.692[17.60]±0.023[0.60]
MAX0.372[9.45]
2.047[52.00]
2.835[72.00]
1.378[35.00]
0%
20%
40%
60%
80%
100%
0 10 20 30 40 50 60
Ambient Temperature(
o
C)
Rated Load(%)
20LFM(Natural Convection)
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified