ACDC 50100 Watts VCS Series xppower.com * Chassis Mount Industrial Supplies * 25 C to +70 C Convection Cooled * Class B Conducted & Radiated Emissions * Output Voltages from 5 V to 48 V * <0.5 W No Load Input Power * Low Cost * 2 Year Warranty Specification Input * 85-264 VAC (127-370 VDC), see derating curve Input Frequency * 47-63 Hz Input Current * VCS50: 1.1 A, VCS70: 1.4 A, VCS100: 2.0 A typical at 90 VAC Inrush Current * 60 A max at 230 VAC, cold start at 25 C Power Factor * EN61000-3-2 Class A Earth Leakage Current * 1.0 mA maximum Input Protection * 50 & 70 W: T3.15 A/250 V 100 W: T4.0A/250 V, fuse fitted in live line No Load Input Power * <0.5 W Input Voltage Output * See model table * 10.0% (5 V & 12 V versions are -5% to +10%) Initial Set Tolerance * 1.0% Minimum Load * None required Start Up Delay * 1 s maximum Hold Up Time * 10 ms min at 115 VAC and full load Line Regulation * 0.5%, 90 VAC to 264 VAC input Load Regulation * 5 V & 12 V versions: 1%, Others: 0.5% 0% to 100% load Transient Response * Less than 4% deviation with a 50% to 75% load change at 1 A/s. Output returns to within 1% in less than 500 s Ripple & Noise * 1% maximum pk-pk, 20 MHz bandwidth Overvoltage Protection * 120-140% of nominal output, auto recovery Overload Protection * 110-150% of nominal, trip and restart Short Circuit Protection * Continuous trip and restart Temperature * 0.03%/C after 20 min warm up Coefficient Output Voltage Output Adjust General Efficiency Isolation Switching Frequency MTBF * See tables * 3000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground * 65 kHz typical * >500 kHrs to MIL-STD-217F at 25 C, GB Environmental Operating Temperature Cooling Operating Humidity Storage Temperature Operating Altitude Shock Vibration * * * * * * -25 C to +70 C, see derating curve Convection cooled 0-95% R.H, non-condensing -40 C to +80 C 3000 m 3 x 30 g shocks in each plane, 30 g: 11 ms (0.5 ms), half sine, compliant to EN60068-2-27 & EN60068-2-47 * 10-500 Hz at 2 g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6 EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals * * * * * * EN55022 Class B conducted & radiated EN61000-3-2 class A EN61000-3-3 EN61000-4-2, level 3 Perf Criteria A EN61000-4-3, level 3 Perf Criteria A EN61000-4-4, level 3 Perf Criteria A (note 3) * EN61000-4-5, installation Class 3, Perf Criteria A * EN61000-4-6, level 3 Perf Criteria A * EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B * IEC60950-1, CSA C22.2 No.60950-1-03, UL60950-1, TUV EN60950-1 Output Power Output Voltage Output Current 40 W 5.0 V 8.00 A 12.0 V 50 W Ripple & Noise(2) Efficiency(1) Model Number 50 mV 79% VCS50US05 4.20 A 120 mV 85% VCS50US12 15.0 V 3.30 A 150 mV 86% VCS50US15 24.0 V 2.10 A 240 mV 88% VCS50US24 48.0 V 1.05 A 480 mV 88% VCS50US48 Notes 3. Level 3 performance criteria A is met for loads >2%. At no load, result is performance criteria A Level 2 or less than 4% output deviation at Level 3. 1. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. 2. Ripple & Noise may exceed specified values below -10 C. Mechanical Details 1 3.07 (78.0) M3 4 locations 2 3 0.75 (19.0) 4 5 1.14 (29.0) 1.18 (30.0) 0.59 (15.0) 1.69 (43.0) 4.35 (110.5) Pin 1 2 3 4 5 3.82 (97.0) 0.157 (4.0) 0.43 (11.0) Notes 0.14 (3.5) 0.47 (12.0) 1.38 (35.0) 1. All dimensions in inches (mm) 2. Weight: 0.55 lbs (250 g) approx 3. Tolerance 0.02 (0.5) 4. Maximum mounting screw penetration 0.157 (4.0) from outer surface 0.41 (10.5) M3 3 locations 0.70 (17.7) Function AC Live AC Neutral Ground -Vout +Vout 0.98 (25.0) 100 100 80 80 Output Power (%) Output Power (%) Derating Curves 60 40 20 -25 -10 0 10 20 30 40 50 Ambient Temperature (C) 60 70 60 40 20 85 90 100 110 120 230 Input Voltage (VAC) 240 250 264 ACDC VCS50 Model and Ratings Output Power Output Voltage 50 W 70 W Output Current Ripple & Noise(2) Efficiency(1) Model Number 5.0 V 10.0 A 50 mV 80% VCS70US05 12.0 V 5.83 A 120 mV 87% VCS70US12 15.0 V 4.67 A 150 mV 87% VCS70US15 24.0 V 2.92 A 240 mV 87% VCS70US24 48.0 V 1.46 A 480 mV 87% VCS70US48 Notes 1. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. 2. Ripple & Noise may exceed specified values below -10 C. 3. For all loads. Mechanical Details 0.14 (3.5) 0.2 (5.1) 1 2 3 3.88 (98.5) 4 1.26 (32.0) 3.55 (90.1) 5 M3 2 locations 1.36 (34.5) 3.08 (78.3) 0.22 (5.5) 0.20 (5.0) O 0.13 (3.3) 0.75 (19.0) 1.61 (41.0) 0.80 (20.3) 0.14 (3.5) 1.21 (30.8) 1.18 (30.0) 3.07 (78.0) 0.20 (5.2) Function AC Live AC Neutral Ground -Vout +Vout Notes 0.43 (11.0) 1.28 (32.4) Pin 1 2 3 4 5 0.22 (5.5) O 0.13 (3.3) 5.12 (130.0) 1. All dimensions in inches (mm) 2. Weight: 0.88 lbs (400 g) approx 3. Tolerance 0.02 (0.5) 4. Maximum mounting screw penetration 0.157 (4.0) from outer surface M3 3 locations Derating Curves 100 100 80 80 Output Power (%) Output Power (%) ACDC VCS70 Model and Ratings 60 40 20 -25 -10 0 10 20 30 40 50 Ambient Temperature (C) 60 70 60 40 20 85 90 100 110 120 230 Input Voltage (VAC) 240 250 264 Output Power Output Voltage Output Current 70 W 5.0 V 14.0 A 12.0 V 100 W ACDC VCS100 Model and Ratings Ripple & Noise(2) Efficiency(1) Model Number 50 mV 78.0% VCS100US05 8.33 A 120 mV 85.0% VCS100US12 15.0 V 6.67 A 150 mV 86.0% VCS100US15 24.0 V 4.17 A 240 mV 86.5% VCS100US24 48.0 V 2.08 A 480 mV 88.0% VCS100US48 Notes 1. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. 2. Ripple & Noise may exceed specified values below -10 C. 3. Level 3 performance criteria A is met for loads >10%. At no load, result is performance criteria A at Level 2 or less than 5% output deviation at Level 3. Mechanical Details 0.20 (5.0) 0.16 (4.0) 1 M3 4 locations 2 3 3.87 (98.2) 1.26 (32.0) 3.52 (89.5) 4 5 6 7 1.30 (33.0) 0.90 (24.0) 3.07 (78.0) 0.2 (5.0) 6.26 (159.0) 0.24 (6.0) Pin 1 2 3 4 5 6 7 0.19 (4.8) 0.16 (4.0) O0.13 (3.3) 1.65 (42.0) 0.87 (22.2) 0.71 (18.0) Notes 100 100 80 80 Output Power (%) Output Power (%) Derating Curves 60 40 20 -10 0 Function AC Live AC Neutral Ground -Vout -Vout +Vout +Vout 1. All dimensions in inches (mm) 2. Weight: 1.1 lbs (500 g) approx 3. Tolerance 0.02 (0.5) 4. Maximum mounting screw penetration 0.157 (4.0) from outer surface 0.37 (9.3) 5.49 (139.5) 1.08 (27.5) -25 0.16 (4.0) 1.02 (26.0) M3 3 locations 0.74 (18.8) 0.24 (6.0) 10 20 30 40 50 Ambient Temperature (C) 60 70 60 40 20 85 90 100 110 120 230 240 250 264 Input Voltage (VAC) 19-July-12