D-30 30W Dual Output Switching Power Supply series Features : AC input range selected by switch Protections:Short circuit/Over load Cooling by free air convection LED indicator for power on Fixed switching frequency at 23KHz 1 year warranty SPECIFICATION MODEL OUTPUT INPUT D-30A D-30B DC VOLTAGE 5V 12V 5V 24V RATED CURRENT 4A 1A 2.2A 1A CURRENT RANGE 0.5 ~ 4A 0.1 ~ 1A 0.5 ~ 4A 0.1 ~ 1A RATED POWER 32W 35W RIPPLE & NOISE (max.) Note.2 50mVp-p 100mVp-p 50mVp-p 100mVp-p + 3,-7% CH1 : 4.75 ~ 5.5V 2% + 3,-5% VOLTAGE ADJ. RANGE CH1 : 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION 0.5% 1.0% 0.5% 1.0% LOAD REGULATION 0.5% 4.0% 0.5% 4.0% SETUP, RISE, HOLD TIME 200ms, 50ms, 30ms at full load VOLTAGE RANGE 85 ~ 132VAC / 170 ~ 264VAC selected by switch FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY(Typ.) 72% AC CURRENT INRUSH CURRENT(max.) 0.8A/115VAC 0.45A/230VAC COLD START 18A/115VAC 36A/230VAC LEAKAGE CURRENT PROTECTION OVER LOAD WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE 240 ~ 370VDC 74% <1mA / 240VAC 105 ~ 150% rated output power Protection type : Fold back current limiting, recovers automatically after fault condition is removed. -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes Design refer to UL1012 I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Design refer to FCC Part15 J Conduction MTBF OTHERS DIMENSION PACKING NOTE 417.6K hrs min. MIL-HDBK-217F (25 129*98*38mm (L*W*H) 0.41Kg; 30pcs/13.4Kg/0.86CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. File Name:D-30-SPEC 2004-06-30 http://store.iiic.cc/ D-30 30W Dual Output Switching Power Supply Mechanical Specification Case No. 903 series Unit:mm 31 3 .5 7 122.5 1 9 .5 2 8 5 .5 33 4 98 2- M 3 3 8.2 5 6 7 3 .5 73.5 4.5 129 6.5 32 3 38 28.5 3 .5 3 .5 3 -M 18 1 8 .5 9 9 .5 120 77 Terminal Pin. No Assignment Assignment AC/L AC/N FG Pin No. 1 2 3 Pin No. 4 5 6 Assignment DC OUTPUT COM DC OUTPUT +V2 DC OUTPUT COM Pin No. 7 Assignment DC OUTPUT +V1 Output Derating Static Characteristics (B) Ta=25 100 OUTPUT VOLTAGE (V) +5V 80 LOAD (%) 60 40 20 24 0 0 10 20 30 40 AMBIENT TEMPERATURE ( 50 45 60 55 250 5.0 +24V 23 4.8 200 22 4.6 150 21 4.4 100 +24V 20 19 -10 -10 300 5.2 50 4.2 +5V 4.0 (VERTICAL) (HORIZONTAL) ) 60 120 85 170 90 180 95 190 100 200 105 210 110 220 115 230 120 240 125 250 OUTPUT RIPPLE (mVp-p) 25 25 130 260 INPUT VOLTAGE (V) 60Hz File Name:D-30-SPEC 2004-06-30 http://store.iiic.cc/