WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE Note.5
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.7
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT ( .)Typ
LEAKAGE CURRENT
SAFETY STANDARDS Note.6
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
Can be adjusted by internal potentiometer A type only
2500ms, 50ms / 115VAC ; B type 2500ms, 200ms at 95% load 230VAC / 115VACat full load 230VAC
16ms at full load 230VAC / 115VAC
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC (Please refer to "Power Factor Characteristic" curve)
1.4A / 115VAC 0.6A / 230VAC
<0.75mA / 240VAC
95 ~ 108%
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3≧
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
-40 ~ +70 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
± ℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
192.2 ℃K hrs min. MIL-HDBK-217F (25 )
220*68*38.8mm (L*W*H)
1.12Kg; 12pcs/14.4Kg/0.8CUFT
120 W Sing le Outpu t Switch ing Power Sup ply
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
■
HL G - 1 20
s e r i es
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
85 10 (RTH2)℃ ± ℃
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
SHORT CIRCUIT
14 ~ 17V 18 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 38V 41 ~ 46V 54 ~ 63V
47 ~ 53V 59 ~ 65V
92% 92% 93.5% 94% 94% 94% 94%94% 94%
±2.5%
5 ~ 10A
±2.0%
4 ~ 8A
±1.0%
3 ~ 6A
±1.0%
2.5 ~ 5A
±1.0%
2 ~ 4A
±1.0%
1.7 ~ 3.4A
±1.0%
1.2 ~ 2.5A
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±2.0% ±1.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±1.0%
1.1 ~ 2.3A
±0.5%
±0.5%
±1.0%
1.4 ~ 2.9A
±0.5%
±0.5%
12V 15V 20V 24V 30V 36V 48V
10A 8A 6A 5A 4A 3.4A 2.5A
120W 120W 120W 120W 120W 122.4W 120W
150mVp-p 150mVp-p
13.5 ~ 17V
150mVp-p
17 ~ 22V
150mVp-p
22 ~ 27V
200mVp-p
27 ~ 33V
200mVp-p
33 ~ 40V
200mVp-p
43 ~ 53V10.8 ~ 13.5V
54V
2.3A
124.2W
200mVp-p
49 ~ 58V
42V
2.9A
121.8W
200mVp-p
38 ~ 46V
HLG-120-12 HLG-120-15
HLG-120-20
HLG-120-24
HLG-120-30
HLG-120-36
HLG-120-48 HLG-120-54
HLG-120-42
IP65 IP67
℃
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
EMC IMMUNITY
EMC EMISSION
UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1, J 61347-2-13 approved ;
design refer to UL60950-1, TUV EN60950-1
COLD START 60A(t =375 s measured at 50% I ) at 230VAC
width peak
μ