Technical Data 2150 Effective February 2016 Supersedes August 2014 Two-pole high SCCR UL Type 2 surge protective devices for split-phase Delta and Wye systems Standard local visual indication The green and red visual indicator flags show the module protective status (green = good, red = replace). Optional remote contact signaling Remote contact signaling available The three-pole terminal remote contact signaling option has a floating changeover contact for use as a break or make contact, according to circuit concept. Specifications: System volts easyIDTM local visual status indication Catalog symbols: * BSPM2___S3G * BSPM2___S3GR Description: Eaton BussmannTM series two-pole UL modular surge arresters feature easyIDTM local visual indication and optional remote contact signaling for system monitoring. The unique module locking system fixes the protection modules to the base and they can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement. * 120/240Vac * 240/480Vac * 120/208Vac * 277/480Vac * 240Vac * 480Vac Short-Circuit Current Rating (SCCR) * Up to 200kA Systems types * Single-phase center tap * 3 wire Wye * 2 wire Delta, corner ground and ungrounded Agency information * UL(R) Recognized 1449 4th Edition, Type 2 Component Assembly * Vibration and shock tested per EN 60068-2 * CE * RoHS compliant Mounting * 35mm DIN-Rail Warranty * Five years Technical Data 2150 Two-pole high SCCR UL Type 2 surge protective devices for split-phase Delta and Wye systems Effective February 2016 Dimensions - mm: Module circuit diagrams: Shown with optional remote contact signaling L1 L2 MOV 12 11 14 12 11 14 Optional remote contact signal Thermal disconnector Gnd/N Gnd/N BSPM2240S3G BSPM2480S3G Shown with optional remote contact signaling. Typical installation/system application: L L1 L2 N N L L1 L1 L2 L2 L3 120/240V, 240/480Vac 120/208V, 277/480Vac 2 wire corner grounded delta Single-phase (split) center tap 3 wire Wye 240, 480Vac BSPM2240S3G, BSPM2480S3G BSPM2240S3G, BSPM2480S3G 2 Eaton.com/bussmannseries BSPM2440S3G, BSPM2480S3G 2 wire ungrounded delta 240, 480Vac BSPM2440S3G, BSPM2480S3G Technical Data 2150 Two-pole high SCCR UL Type 2 surge protective devices for split-phase Delta and Wye systems Effective February 2016 Ordering information: Nominal system voltage Max. Continuous Operating Voltage MCOV (VC) Catalog numbers (base + modules) Replacement module [L-G/L-L] W/O remote signaling W/ remote signaling MOV technology 120/240, 240Vac 275/550Vac BSPM2240S3G BSPM2240S3GR BPM275UL 240/480Vac 385/770Vac BSPM2480S3G BSPM2480S3GR BPM385UL 120-127Vac 240-254Vac 240Vac 1kV/1.8kV 240-480Vac 480Vac Specifications Rated voltage Voltage Protection Rating VPR [L-G/L-L] Discharge current Response time tA SCCR Frequency Number of poles Number of wires/connection points Operating state/fault indication Cross-sectional area Terminal torque Mounting Enclosure material Protection Location Capacity Application/standard Agency information Warranty Remote contact signaling Signaling type Switching capacity (volts/amps) Conductor and cross-sectional area Ordering information 1.5kV/2.5kV Nom. In 20kA Max. Imax 40kA 25 ns 200kA 50/60Hz 2 2 wires or 3 wires / 3 connection points Green (good) / Red (replace) Min. 14AWG - Cu stranded, solid or fine Max. 2AWG - Cu solid or stranded, 4AWG - Cu fine 45 lb-in (5.1N*m) 35mm DIN-rail per EN 60715 Thermoplastic, UL 94V0 IP20 (finger-safe) Indoor 2 mods, DIN 43880 UL Type 2 Component Assembly, UL 1449, 4th Edition cURus, RoHS Compliant Five years* Changeover contact AC 250V/0.5A DC 250V/0.1A; 125V/0.2A; 75V/0.5A 60/75C Max. 1.5mm2/14AWG solid/flexible Order from catalog numbers above * See Eaton Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge. Eaton.com/bussmannseries 3 Technical Data 2150 Two-pole high SCCR UL Type 2 surge protective devices for split-phase Delta and Wye systems Effective February 2016 The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 Eaton.com Bussmann Division 114 Old State Road Ellisville, MO 63021 United States Eaton.com/bussmannseries (c) 2016 Eaton All Rights Reserved Printed in USA Publication No. 2150 -- BU-MC16XXX February 2016 Eaton and Bussmann are valuable trademarks of Eaton in the U.S. and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. Follow us on social media to get the latest product and support information.